Newco 873N, 872D, 872B User Manual

Page 1
Part No. 803171 Issued 3-28-13 Rev 011515
1
MODEL #
WIDTH
DEPTH
HEIGHT
872D
9.8
12.8
17.1
873N
12.8
9.8
17.1
872B
9.8
12.8
23.4
MODEL 872D
MODEL 873N
MODEL 872D MODEL 873N
MODEL 872B
POST-MIX BEVERAGE DISPENSER
The Post-Mix Beverage Series utilizes a venturi valve to mix the tea syrup with the water. A built-in water pressure regulator ensures the proper amount of syrup is being mixed with the proper amount of water. This built-in pressure regulator is factory adjusted for a static pressure
of 18 pounds.
FOR USE WITH BAG-IN-BOX
3650 New Town Blvd. St. Charles MO, 63301 www.Newcocoffee.com
636.925.1202
800.325.7867
Page 2
Part No. 803171 Issued 3-28-13 Rev 011515
2
Water
On
Water
Off
OUT
RIDGE
Installation
1. Carefully remove the dispenser from the shipping carton.
2. Before attaching the waterline to the
dispenser, flush the waterline to re­move any foreign particles that may be in the line.
NOTE: It is advisable to use a lime, scale,
sediment, taste and odor purification char­coal water filter where water quality is a concern.
3. Connect waterline to inlet fitting on rear of dispenser. Fitting may vary.
4. Turn on the water source to the dispenser.
5. Turn the yellow handle to the ON position
to allow water to flow through the urn.
Product Loading
1. Open the BIB along the perforated edges. Pull out the dispensing spout.
2. Remove the cap from the spout.
3. Connect the QCD as shown to dispensing spout. Scholle fitting screws onto BIB.
Note: THE FITMENT MUST BE PUSHED ALL THE WAY OUT SO THAT THE WORD “OUT” IS EXPOSED ON THE TOP OF THE FITMENT.
4. Place the QCD into the neck of the
dispensing spout at the ridge as shown on the illustration.
Page 3
Part No. 803171 Issued 3-28-13 Rev 011515
3
Flush Position
5. Press QCD towards the dispensing spout until it is flush with the collar of the QCD.
6. The BIB should lie horizontally
Avoid loops in the product line
Use the minimum amount of
product line required.
Check for air bubbles in the product
line to trouble shoot for priming.
PRIME SYSTEM
7. After the BIB has been connected to the QCD valve dispense ap-
proximately 12 ounces of product.
8. Dispense another 8 ounces of prod­uct and sample for taste. If an adjustment is necessary, refer to taste calibration section page #7
NOTE: Be sure there are no air bub­bles in the product line.
Cleaning Instructions
To clean and flush lines before connecting BIB product to unit or when changing product. Flush should be performed at least once a week.
Note: Cleaning requires the use of a cleaning/flush adapter. An adapter may be purchased from Newco Enterprises, Inc. #320282 for QCD cleaning/flush adapter. #120508 for Scholle cleaning/flush adapter. A cleaning adapter can be made by taking an empty BIB bag and cutting away as much of the empty bag as possible. Wash the remaining connector and further trim off any remaining bag pieces if desired. This is now your cleaning adapter. It will allow the check valve in the connector to stay open during the cleaning process. Cleaning adapters may be saved for later use.
1. Connect clean/flush adapter to QCD or
Scholle connector.
2. Place connector with adapter in
container of hot water.
3. Lock or hold faucet handle down until
clear water runs from faucet.
4. Remove adapter from connector.
5. Attach connector to new BIB.
Page 4
Part No. 803171 Issued 3-28-13 Rev 011515
4
Seat Cup
Handle
Cap (Bonnet)
Clean Dispenser and Faucet
1. Turn off water source to dispenser
3. Unscrew the faucet/handle cap assembly from the faucet.
2. Open and close the faucet handle to relieve system of water.
4. Wipe inside of faucet body with a mild dishwashing soap and hot water.
5. Do the same to handle, cap, and seat cup.
6. Reinstall assembly to faucet body, taking care not to cross thread when installing. Finger tight is adequate.
7. Turn water source to on position.
8. Dispense approximately 12 ounces.
Page 5
Part No. 803171 Issued 3-28-13 Rev 011515
5
WEEKLY SANITIZING
The following procedure Applies To Each Dispenser Head
Bag in Box
1. Follow steps 1-3 of cleaning instructions on page #3
2. Shut off water supply valve on the back of the dispenser.
3. Open and close faucet handle to relieve system of water.
4. Unscrew the faucet handle/cap assembly from faucet.
5. Wash the faucet/cap/seat cup assembly in a mild dishwashing soap and warm water.
6. Reinstall assembly to faucet body taking care not to cross thread when installing. Finger
tight is adequate.
7. Turn water supply on.
8. Prepare one gallon of food grade sanitizing solution *(200 ppm available chlorine) in a
suitable container per the sanitizer manufacturers instructions. Use 100 F water.
9. Place BIB connector into the sanitizing solution. Ensure connector is submerged to
bottom.
10. Place a large vessel under the faucet. Lock or hold faucet open until container of
sanitizing solution is empty. DO NOT FLUSH UNTIL THE FOLLOWING MORNING
11. Flush by reloading the dispenser with concentrate. Lock or hold faucet handle down
until the tea is dispensed from the faucet. Dispense three 8 oz. servings and discard. * Sanitizing solution with 200 ppm available chlorine can be made by adding ½ oz. (1 tablespoon) of regular household bleach(6% sodium hypochlorite solution) per gallon of water.
Do’s and Don’ts
OPERATION
1. Do fully activate faucet handle when dis­pensing drinks.
2. Do clean & sanitize dispensing assembly weekly.
3. Do keep dispenser primed with concentrate at all times.
4. Do reload immediately when out of con­centrate.
5. Do flush and clean lines regularly.
6. Don’t forget to clean & sanitize faucet seat cup
7. Do follow all cleaning and sanitizing pro­cedures, remove and store concentrate if urn will not be used for an extended period of time; ie: more than two days.
1. Do connect dispenser to a filtered waterline.
2. Do flush filters before connecting to dispenser.
3. Do sample finished drink before making adjust-
4. Do make very slight drink adjustments then sam-
5. Don’t forget to flush filters before installation.
6. Don’t make any pressure regulator adjustments
7. Don’t forget to get sample approval from cus-
INSTALLATION
ments.
ple.
on urn. (Do NOT attempt to adjust the urn regu­lator. If a regulator adjustment is required call the factory at 1-800-556-3926. The adjustment should be made by a qualified service techni­cian.)
tomer.
Page 6
Part No. 803171 Issued 3-28-13 Rev 011515
6
PROBLEM
CAUSE
CORRECTIVE ACTION
Difficulty priming dispenser.
1. Product adjustment screw turned in too far.
1. Turn adjustment dial ¼ turn
C’Clockwise(weaker/
stronger)adjustment.
2. Regulator adjustment is re-
quired. Call the factory for assistance.
Pulled faucet handle, no product, no water.
1. Water supply not on.
1. Turn water supply on.
Drink too foamy or bubbly
1. Concentrate BIB empty.
2. Hole or tear in product tubing prior to BIB connection.
3. Loose syrup line connection.
1. Load new BIB
2. Replace tubing
3. Check syrup line
connections from check valve.
Drink inconsistent
1. Waterline pressure dropping below machine’s preset pressure regulator adjustment.
2. Regulator adjustment is re-
quired. Call the factory for assistance.
Water onlyno product
1. Concentrate BIB empty.
2. Product hose clogged.
3. Product hose kinked.
4. Check valve not seating.
5. Adjustment screw in too far.
1. Load new BIB.
2. Clean product hose or
replace.
3. Check for kinks.
4. Disassemble and clean check
valve.
5. Turn adjustment screw out
using adjustment dial.
Faucet dripping
1. Foreign particles on seat cup.
2. Damaged seat cup.
3. Pressure set too high.
1. Follow seat cup cleaning.
2. Replace seat cup.
3. Regulator adjustment is
required. Call the factory for assistance.
Drink too weak
1. Adjustment screw in too far.
2. Check valve not seating.
1. Turn adjustment screw out
Weaker/Stronger adjustment.
2. Disassemble and clean check
valve.
Air bubbles in syrup
1. Loose tubing connection at QCD or at check valve barb.
2. Worn O-ring on QCD plunger.
3. Air in bag.
1. Ensure tubing is slid all the
way on to the QCD and check valve barb.
2. Replace QCD.
3. Stand BIB upright, open
faucet handle and prime syrup line until all air bubbles are gone.
Page 7
Part No. 803171 Issued 3-28-13 Rev 011515
7
Remove Top Cover.
Remove Product And
Hang Over Sides Of
Dispenser.
Loosen Screw, Slide Access Panel
Toward Front And Remove.
After Access Panel Is Removed
Adjustment Dials Are Accessible
From The Top Side.
Taste Calibration For Postmix Beverage Dispenser With Low Pressure Faucet
Page 8
Part No. 803171 Issued 3-28-13 Rev 011515
8
Rotate Dial Counter Clockwise For
Stronger Mixture Or Clockwise
For Leaner Mixture. Make small
adjustments(approximately 1 ½
points or 1/8 turn at a time)
After Adjustments Are Made
Replace Access Panel
& Tighten Screw
Replace Product And Syrup Lines.
Replace Top Cover.
Page 9
Part No. 803171 Issued 3-28-13 Rev 011515
9
Page 10
Part No. 803171 Issued 3-28-13 Rev 011515
10
Page 11
11
Part No. 803171 Issued 3-28-13 Rev 011515
Additional Parts:
14410 Black Plastic Cover, Small 803197 Drip Tray, S.S. Grid
Page 12
Part No. 803171 Issued 3-28-13 Rev. 011515
12
1.5 mm Hex Wrench #803201
3mm x 5mm Setscrew #803200
Dial Knob #803118
Dial Plate
White
Indicator
DIAL REMOVAL
Use 1.5mm hex wrench to remove dial knob. This wrench is supplied with the unit. IMPORTANT: When removing the dial knob note the position of the white indicator on the knob. Remove the dial plate after the dial knob is removed. This area is now open for cleaning and troubleshooting.
When reassembling dial knob to shaft be sure that the white indicator is in the same position as before. If factory orientation is lost turn the bare dial knob shaft clockwise until it stops and position the dial as shown above. Tighten setscrew.