NewAir AC10100H, AC10100E User Manual

Page 1
Page 2
Page 3
ELECTRICAL SAFETY
This appliance is for indoor use only.
Always turn off the unit and unplug it when not in use.
Do not use this unit in excessively humid or wet environments.
Do not pull or place strain on the power cord when moving the appliance.
IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY AN ELECTRICIAN
FOR MAXIMUM EFFICENCY
Do not exceed the recommended room size.
Make sure doors and windows are closed while the portable air conditioner is in use.
Also keep curtains and blinds closed during the sunniest parts of the day while the air conditioner is in operation.
Frequently clean the portable air conditioners filters.
Once the room or area has reached your desired comfort level, be sure to reduce the
units temperature and ventilation settings.
2
Page 4
Page 5
14″
Page 6
extend it with your own hose, as this
Mounting of the Exhaust Pipe
Only use the hose provided and clip exhaust hose to the back of the air conditioner.
Avoid kinks and bends in the exhaust hose. This can cause moist air to accumulate, causing the unit to overheat and shut down.
The exhaust hose may be extended from 12 inches (300mm) to 59 inches (1500mm), but for maximum cooling efficiency use the shortest length possible.
WARNING!
The included exhaust hose is specifically designed to fit the specifications of this unit. Do not
can cause the air conditioner to malfunction.
5
Page 7
carbon filter from its
Installation of the Carbon Filter
1. Remove the filter frame from the unit.
2. Separate the filter fixer from the filter frame.
3. Remove the activated plastic bag.
4. Attach the activated carbon filter to the filter frame.
5. Reattach the filter fixer onto the filter frame (the activated carbon filter should be placed between the filter frame and filter fixer firmly).
6. Insert the filter set (filter frame + activated carbon filter + filter fixer) into the back of the unit.
FIG.13
6
Page 8
Page 9
Setting the Model/Function:
Press the MODE button to select the desired mode (cooling, fan or heating).
Setting Temperature
1. Press 'Temperature up' or 'Temperature down' button to change the set temperature.
2. The display window will indicate the set temperature. If not, the temperature displayed will show the ambient room temperature.
3. Please note that the preset temperatures are as follows:
Cooling: 75oF (24oC)
Heating: 68oF (20oC)
Setting Fan/Ventilation Speed:
1. Press SPEED button to select the desired fan speed (high or low). The indicator light will display the fan speed selected.
2. If the unit is in AUTO mode, it will choose the ventilation speed automatically according to the ambient temperature (the related indicators will light on). In the AUTO mode the fan speed cannot be changed manually.
Setting Timer
1. Press TIMER button to set the desired number of operating hours (from 1 to 12 hours). When the set time has been reached, the machine will turn off automatically. The display window will show the hour(s) you set as you press TIMER button. If the TIMER is not set, the unit will work continuously.
2. By pressing the timer without turning on the other functions, you can PRE-SET the number of hours to be delayed before the unit turns on. For example, if you set the timer to “2”, the unit will automatically turn on after 2 hours.
Sleep Function
1. When in cooling mode, press the SLEEP button. The set temperature will increase 2oF (1oC) on the 1st hour; another 2oF (1oC) on the second hour, and then maintain that temperature.
2. When in heating mode, press the SLEEP button. The set temperature will decrease 2oF (1oC) on the 1st hour; another 2oF (1oC) on the second hour, and then maintain that temperature.
3. In sleep mode, the fan will automatically be set to low. By pressing the SLEEP button again, the set temperature and fan speed will revert back to the previous setting.
4. The unit will shut down automatically after it has been in sleep mode for 12 hours.
5. Please note the sleep function is not available while the machine is working in AUTO or FAN (ventilation) mode. It will only work in cooling or heating mode.
8
Page 10
Heating Function (For AC-10100H Only)
1. When the air conditioner is in heating mode, ambient warm air is recycled and used to heat
your immediate area. The exhaust pipe will still need to be fitted onto the unit in order for the cold air to be removed.
2. Continuous drain is compulsory while the unit is in heat mode. Working range for heating
function is 45 to 77oF (7 ~ 25oC). If the ambient temperature is lower than this range, the unit may not work properly.
All the functions can also be performed with the supplied remote control. The remote
control requires 2 AAA batteries to operate.
Regulating air flow direction
Move the air vent directly to adjust the air flow direction of the louvers.
Please Note:
1. To prolong the life of the compressor, after turning off the unit, please wait at least 3 minutes before turning it back on.
2. The cooling system will turn off if the ambient temperature is lower than the set temperature. However, the fan will continue operating at the set level. Once the ambient temperature rises above the set temperature, cooling will resume.
3. The heating system will turn off if the ambient temperature is higher than the set temperature. The ventilation fan will continue operating at the set level. Once the ambient temperature drops below the set temperature, heating will resume.
4. This machine is equipped with ANTI-FROST function. When using the heating function in low temperature the heater will occasionally stop heating in order to melt any frost that has accumulated within the air conditioner. Normal operation will resume in a few moments.
9
Page 11
DRAINING THE UNIT
During the cooling process, some water will be extracted from the air and stored within the unit’s water reservoir.
If the reservoir is full, both the compressor and motor will stop and the unit will beep (press any
button to stop the beeping sound). The full water tank indicator light will also start flashing.
To resume cooling, empty the reservoir by following these steps:
1. Turn off the air conditioner and unplug it
from the wall socket. To prevent water leakage, avoid moving the unit when full.
2. Place a container (such as a small pan)
underneath the drain hole.
3. Remove the drain knob & rubber plug from
the drain hole and allow the water to drain out.
4. When the container is almost full, replace
the rubber plug in the drain hole and empty the water tray.
5. Repeat until the unit is emptied.
6. Replace the rubber plug and make sure it is
firmly in place.
7. Turn the unit back on. The full tank indicator
light should turn off.
For Continuous Drainage:
Remove the drain knob and rubber plug from the drainage port and hold on to them for future use.
Connect the drain tube to the water outlet as shown. Place the other end of drain tube into a drain.
10
Page 12
The drain tube may be extended by adding an extension tube with a suitable connector.
Please Note:
Drain tube
1. The drain must be at or below the level
of the drainage port.
2. The full water tank indicator light will not work when the unit is being continuously drained.
3. To extend the drain tube, you can connect it with another hose with an overall diameter of approximately 0.7 (18mm).
11
Original drain tube
Extension tube (OD: 0.7)
Page 13
MAINTENANCE INSTRUCTIONS
Always unplug the air conditioner from the power supply before cleaning. To maximize the efficiency of the air conditioner, regularly clean the unit.
Cleaning the Housing:
Use a soft, damp cloth to wipe the body clean.
Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other
cleansing solutions. These all could possibly damage the cabinet.
Cleaning the Filter:
Use a vacuum cleaner or tap the filter lightly to remove loose dust and dirt from the filters. Rinse thoroughly under running water (no hotter than 104oF or 40oC).
Thoroughly dry the filter before replacing it back into the unit.
PLEASE NOTE: NEVER USE THE UNIT WITHOUT THE AIR FILTER.
End of Season Storage:
Completely drain any condensed water from the unit.
Set the air conditioner on fan made (ventilation only) for a few hours to dry the inside of the unit.
Clean or change the filter.
Unplug and store the power cord as
shown.
Place the unit back in its original carton and store it in a clean, dry area.
Cord
12
Page 14
Page 15
Page 16
15
Loading...