A.2 Recycling information .....................................................................................................13
nevion.com | 3
ADDA-AES8 Rev. B
1 Product overview
The ADDA-AES8 is an audio converter product with both A/D and D/A converters on a single
module. The module may be used as a normal Flashlink module in the original frame, in N
boxes and Flashcase. The module may also be used in the new frame in the half width slots
as an auxiliary module for the Flashlink XMUX embedder modules.
The module has two stereo A/D converters and two stereo D/A converters. The gain of the
converters may be set on the DIP switches on the module or with the GYDA Multicon system
controller. The gain settings on the A/D converters are discrete levels while the D/A
converters may be set to a level from +24dBu with 1 dB steps.
The converters are calibrated with low impedance sources and high impedance terminations.
The inputs and outputs are fully compatible with 600 ohm inputs and outputs. True 600 ohm
outputs and inputs are available through special backplanes but the D/A output levels set
with the DIP switches and viewed through GYDA will be 6 dB too low.
The A/D converters may be synchronized to an external AES3 signal with a sample
frequency from 24 kHz to 96 kHz.
The A/D converters’ internal clock, used when there is no reference input, may be configured
to be 48 kHz or 96 kHz.
The D/A converters will accept sample rates up to 192 kHz.
1.1 Top view
nevion.com | 4
ADDA-AES8 Rev. B
1
2
3
2 Specifications
2.1 A/D converters
Differential input impedance: 24 kohm
Common mode input impedance: 50 kohm
Maximum signal level (0 dBFS): +12, +13.5, +15, +16.7, +18, +20, +21 or +24dBu
Level precision: ± 0.1dB where Z
< 40 ohm
source
Common mode voltage tolerance: ± 30V – (Maximum peak signal level)
Frequency response: 20 Hz – 20 kHz ± 0.1 dB
Pass-band ripple: ± 0.005 dB
Stop band attenuation: 90 dB
Dynamic range1: Min. 103 dB (A)2
Typ. 105 dB (A) 0 dBFS = +18dBu
THD+N @ -1 dBFS: Max. -85 dB, typical -90 dB
Intermodulation distortion3: Max. -90 dB, typical -95 dB
Crosstalk: Max. -90 dB, typical -99 dB
CMRR (20 Hz – 15 kHz): Max. 80 dB @ 15 kHz, typical -85 dB @ low
frequencies
Internal Sampling frequency: 48 or 96 kHz
Digital outputs: AES3 110 ohm.
2.2 D/A converters
Differential output impedance: 53 ohms.
Common mode output impedance: 20 kohm.
Level precision: ± 0.1dB where Z
> 10 kohm
load
Maximum signal level (0 dBFS): +24dBu or lower in 1 dB steps.
Common mode voltage tolerance: +50V, -0.1V
Frequency response: 20 Hz – 20 kHz ± 0.1 dB
Pass-band ripple: ± 0.002 dB
Stop band attenuation: 60 dB
Dynamic range: Min. 103 dB(A)
Typ. 109 dB(A) 0 dBFS = +18dBu
THD+N @ 1 kHz, -1 dBFS: Max. -85 dB, typical -85 dB.
Intermodulation distortion: Max. -75 dB
|THD+N of -60 dBFS 1 kHz signal| + 60.
Dynamic range is a function of full scale level. Minimum result is obtained with 0dBFS =
As all Flashlink modules, the module either uses the internally stored configuration, or uses
the configuration on the DIP switches. The DIP switch labeled ‘DIP config mode’ controls this
behavior.
3.1 DIP configuration mode
SW2.8 is the DIP config mode switch.
On: The card will be configured with the other DIP switches. The module will not accept
commands from the system controller but may be monitored.
Off: The module will be configured with the internally stored configuration and may be
controlled with FLP4 commands as listed in chapter 6.
As with all Flashlink modules, stored configurations in the Multicon controller will be applied
to a module that is plugged into a running system, provided that the switch SW2.8 is off and
that the last module present in the system was of the same type.
A module with SW2.8 on, plugged into a running system will overwrite the stored
configuration in the Multicon controller with its own configuration.
3.1.1 Converter gain
The DIP switches are grouped as sets of three switches for each of the stereo converters.
The levels correspond to the maximum sine wave level, otherwise known 0 dBFS.
These values are chosen as being the most often used levels in the broadcast industry.
Custom values are available, contact Nevion support or your local sales representative. The
D/A converter gain setting has a 1dB resolution so the gains at 13.5 and 16.7 dB are
rounded up to 14 and 17 dB respectively.
3.1.2 A/D Internal Clock frequency
SW1.8 controls the A/D converter clock when there is no signal at the reference input. If the
switch is in the off position, the internal sample rate of the A/D converters is 48 kHz.
Otherwise, the internal sample rate of the A/D converters is 96 kHz.
3.2 Multicon control
The module may be monitored and controlled with the Multicon system controller. The
converter gains and A/D internal clock frequency may be remotely controlled through the
module’s configuration page of the system controller.
The AES digital audio input signal presence and the on-board power levels are presented on
the info page. Alarms are generated for AES input loss (including the external reference) and
power supply violations.
nevion.com | 7
ADDA-AES8 Rev. B
4 Connections
The standard backplane supplied with the ADDA-AES8 is the ADDA-AES8-C1.
This backplane uses the standard pin assignment for the female DB-25 and a similar one for
the female DA-15 as shown below.
nevion.com | 8
ADDA-AES8 Rev. B
5 Operation
5.1 LEDs
The module has four LEDs.
5.1.1 Status
The Status LED is green when the module is programmed and functioning normally. It will
turn red for 1 second when power is applied and then turn green. Orange indicates that the
module is not programmed, or is in the process of being programmed. It will turn red if there
is something wrong with the power supply levels.
5.1.2 Sync
The sync LED is green when the external AES sync signal is received correctly.
The LED is red if there is no input or the signal has errors.
5.1.3 AES input 1 & 2
The two LEDs function in the same way.
The LED is green when the corresponding AES signal is received correctly.
The LED is red if there is no input or the signal has errors.
The LED is orange if the signal is present but is not PCM encoded audio.
nevion.com | 9
ADDA-AES8 Rev. B
Block no.
Audio Port
0
D/A analogue stereo output 1
1
D/A analogue stereo output 2
2
A/D analogue stereo input 1
3
A/D analogue stereo input 2
4
AES input to D/A 1
5
AES input to D/A 2
6
AES reference input.
6 FLP4 commands
FLP stands for Flashlink Protocol. The current revision of this protocol is 4, hence FLP4. This
specification is available form Nevion support.
The following FLP4 block commands are used in the monitoring and control of the module.
ablk
pwr
6.1 ablk
The ‘ablk’ blocks correspond to the physical audio ports as follows.
Blocks 0 to 3 report and accept the ‘lvl’ keyword followed by the maximum input level in cBu
(dBu multiplied by 10).
i.e. ablk 0 lvl 240 cBu
Blocks 4 to 6 report input presence with the ‘freq’ keyword followed by the received sample
frequency or 'los' or 'lol'. Absence of signal is reported with 'los' while 'lol' indicates an
unrecognized sample frequency.
i.e. ablk 4 input freq 44 kHz
6.2 pwr
The ‘pwr’ blocks from 0 to 4 list the levels of the power supplies as measured by the
microcontroller.
0 is the frame +5V
1 is analogue +4.75V
2 is the frame +15V
3 is the frame -15V
4 is digital +3.3V
The frame supplies are measured after the module fuses and filtering.
6.3 On-site re-programming.
The module may be re-programmed on site with a GYDA Multicon system controller.
Firmware will be provided by Nevion support when necessary.
nevion.com | 10
ADDA-AES8 Rev. B
1.
The equipment will meet the guaranteed performance specification under the following
environmental conditions:
-
Operating room temperature range:
0°C to 45°C
-
Operating relative humidity range:
<90% (non-condensing)
2.
The equipment will operate without damage under the following environmental
conditions:
-
Temperature range:
-10°C to 55°C
-
Relative humidity range:
<90% (non-condensing)
General environmental requirements for Nevion equipment
nevion.com | 11
ADDA-AES8 Rev. B
Product Warranty
The warranty terms and conditions for the product(s) covered by this manual follow the
General Sales Conditions by Nevion, which are available on the company web site:
www.nevion.com
nevion.com | 12
ADDA-AES8 Rev. B
組成名稱
Part Name
Toxic or hazardous substances and elements
鉛
Lead
(Pb)
汞
Mercury
(Hg)
镉
Cadmium
(Cd)
六价铬
Hexavalen
t
Chromium
(Cr(VI))
多溴联苯
Polybrominate
d biphenyls
(PBB)
多溴二苯醚
Polybrominated
diphenyl ethers
(PBDE)
ADDA-AES8
O O O O O
O
<Power supply, if
delivered with
unit>
O O O O O
O
O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this
part is below the limit requirement in SJ/T11363-2006.
X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous
materials used for this part is above the limit requirement in SJ/T11363-2006.
Appendix A Materials declaration and recycling information
A.1 Materials declaration
For product sold into China after 1st March 2007, we comply with the “Administrative
Measure on the Control of Pollution by Electronic Information Products”. In the first stage of
this legislation, content of six hazardous materials has to be declared. The table below
shows the required information.
This is indicated by the product marking:
A.2 Recycling information
Nevion provides assistance to customers and recyclers through our web site
http://www.nevion.com/. Please contact Nevion’s Customer Support for assistance with
recycling if this site does not show the information you require.
Where it is not possible to return the product to Nevion or its agents for recycling, the
following general information may be of assistance:
Before attempting disassembly, ensure the product is completely disconnected from
power and signal connections.
All major parts are marked or labeled to show their material content.
Depending on the date of manufacture, this product may contain lead in solder.
Some circuit boards may contain battery-backed memory devices.
nevion.com | 13
Loading...