NEUTRIK powerCON TRUE1, power TRU 1 NAC3MX-W Assembly Manual

Page 1BDA 380
power TRU 1CON E
|
R
ASSEMBLY INSTRUCTION
2
0
250
S E
JET
1
6
250
2
0
250
NAC3MX-W
Place chuck overthe the cable.
Prepare cable asthe shown.
D
B. ASSEMBLY INSTRUCTION
A. OPERATING INSTRUCTION
Application: The power TRUE1 system is certified as connector with breaking cap ity according IECCON ac 60320, VDE It is intended for use as It0625. appliance couplers and interconnection couplers. serves to supply power to appliance and from an appliance to another equipment.an To be installed by qualified person only.
Connector Assignment:
NAC3PX
NAC3MPX
NAC3FPX NAC3FPX-ST
20
250
P S
E
JE
T
20
250
P
S E
JET
16
250
20
250
NAC3MX-W
20
250
P
S E
JET
16
250
20
250
NAC3MX-W
20
250
P S
E
JET
Power IN
Powe r OUT
Power IN
Powe r OUT
[0.32"]
8 mm
[”]0.787
2mm0
[”]0.9
PE 23 mm
NAC3MX-W
(Plug connector)
NAC3FX-W
(Connector)
NAC3FX-W
(Connector)
NAC3MX-W
(Plug connector)
Separate the housing from the bushing (cable remain in bushing)
A
B
Insert cable into the bushing and housing.
Note: “Apply cable pulling lubricant to cable jacket.”
C
20
250
P S
E
JET
16
250
2
0
250
NAC3MX-W
Approval based:
Rating: Cable Type:
Strain Relief: Cable O.D.:
VDE
EN 60320-1/EN60320-2-2
250 V ac / 16 A H05VV-F3G 1.0 mm , Length max. 2 m
2
H05VV-F3G 1.5 - 2.5 mm
2
H07RN-F3G 1.5 mm
2
White chuck
6.0 - 12.0 mm
UL
UL 498 / CSA C22.2 No. 182.3
250 V ac / 20 A SJTOW, SJOOW 3 x 12 AWG
White chuck
6.0 - 12.0 mm
C
[0.32"]
8 mm
[”]0.787
2mm0
[”]0.9
PE 23 mm
VDE (EN 60320-1/EN60320-2-2) UL (UL 498 / CSA C22.2 No. 182.3)
40 - 50 mm
APPLIANCE INLET APPLIANCE OUTLET
APPLIANCE INLET - OUTLET
COMBINATION
Draft. Nr.: BDA Update:380 13.07.2016 Data subject to change withoutprior notice. 201 NEUTRIK . ALLRIGHTS RESERVED.5 NEUTRIK are registered trademark.
II
©
® ®
NEUTRIK AG T: F:LI +423 /237 24 24 +423 232 53 93/ NEUTRIK USA Inc. T: F :USA +1 704/ 972 3050 +1 704 438 9202/ NEUTRIK UK Ltd.
()
T: F:UK +44 1983/ 811441 +44 1983 811 439/
NEUTRIK Vertriebs GmbH T: F:DE/NL/AT/DK +49 8131 /280 890 +49 8131 280 830/
NEUTRIK France FR T: F:+33 1 4131 6750 +33 1 4131 0511// NEUTRIK Tokyo Ltd. JP T: F :+81 3 3663 4733 +81 3 3663 4796// NEUTRIK Hong Kong Ltd. T: F:HK +852 2687 6055 +852 2687 6052// NEUTRIK India Pvt. Ltd. IND T: F:+ +91 22 26163 54091/ 982 05 43 424 /
ASSEMBLY INSTRUCTION powerCON TRUE1
I
R
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
20
250
P S
E
JET
16
250
20
250
NAC3MX-W
Torque Value 0.7 Nm
5.
Torque Value 2.0Nm
PRESS FIRMLY
Torx size T8
1.
2.
4.
Wrench size 13 mm
6.
3.
Important: Push and turn simultaneously.
FOR DISASSEMBLY - OPEN TWIST LOCK!
1. Press with screw driver to unlock
Turn bushing 360°.2.
Repat step 1 + 2 until bushing is unscrewed.3.
1.
2.
CAUTION
To ensure protection category, do not expose the connection to bending forces (e.g. do not attach loads to the cable, no free-dangling cable windings etc.).
LIECHTENSTEIN
20
250
P S
E
JET
G
E
F
Important: Align r keyubber
latch.and
Insert the wires into the terminals and fasten the screw with Torx size T8.
Wiring VDE UL
blackL brownÞ whiteN blueÞ
green / yellow greenÞ
Slide the chuck onto the insert (1) and then both together into housing (2).
Important: Align the chuck byand insert positioning the nose into keyway.the
Slide the bushing up the cable tighten itand with the tool as shown.
Important: Yellow O-ring to hide to achieve IP
protection (6).
(Tool available: Art. No. HTAC)
FORCE
SAFETY WARNING
For safety and certification reasons the connector must be replaced in case of any broken parts or serious damage.
Loading...