IMPORTANT SAFETY INSTRUCTION:
The powerCON system is certified as connector without breaking capacity according IEC 61984 / VDE 0627.
In this standard the term connector (without breaking capacity) refers to components which in normal use are not to
be engaged or disengaged when under load or live.
Connecto r Combination & Keyways:
With the two non-interchangeable types of connectors (A type and B type) it is impossible to produce a short circuit.
Mating connectors (combination) are identified by mechanical keyways and by color.
L
IE
CH
TE
NS
T
EIN
L
I
E
C
HT
EN
S
T
E
I
N
A type (color coding blue)
POWER IN
B type (color coding gray)
POWER OUT
B. ASSEMBLY INSTRUCTION
Place the bushing (1) and the chuck (2) over
the cable.
White chuck (a): 6.0 - 11.0 mm [0.236 - 0.433”]
Black chuck (b): 9.5 - 15.0 mm [0.374 - 0.59”]
VDE: 9.5 - 14.0 mm [0.374 - 0.551”]
Prepare the cable as shown.
Cable O.D.: 6.0 - 15.0 mm [0.236 - 0.59”]
2
Wire size: 2.5 mm (AWG 14)
Insert the wire into the terminals and fasten
the clamping device with a POZIDRIV® #1,
max. Torque 0.5 Nm (0.37 lb-ft).
B
A
B
[0.32 "]
8 mm
[0.78 7”]
20 mm
[0.9” ]
PE 23 mm
NAC3MPA-1
NAC3FCA
NAC3MPB-1
NAC3FCB
C
Torque Value 0.5 Nm
POZIDRIV® #1
N
L
WIRING
C
ð
or
1.
2.
b
a
A

ASSEMBLY INSTRUCTION Locking 3 pole powerCON
I
www.neutrik.c om
NEUTRIK AG LI T: +423 / 237 24 2 4 F: +423 / 2 32 53 93
NEUTRIK USA Inc. USA T: +1 704 / 972 30 50 F: +1 704 / 438 92 02
( )
NEUTRIK UK Lt d. UK T: +44 19 83 / 811 441 F: +44 1 983 / 811 439
NEUTRIK Vertriebs G mbH DE / NL / AT/DK T: +49 81 31 / 280 89 0 F : +49 813 1 / 280 830
NEUTRIK France FR T: +33 1 / 4131 675 0 F: +33 1 / 4131 0511
NEUTRIK Tokyo Ltd. JP T: +81 3 / 3663 473 3 F: + 81 3 / 3663 4 796
NEUTRIK Hong Kon g Ltd. HK T: +852 / 2 687 6055 F: +852 / 2 687 6052
NEUTRIK India Pv t. Ltd. IND T: +91 / 982 05 43 424 F: +91 / 22 26163
R
Draft. Nr.: BDA 452 Update: 31.08.2015 Data sub ject to change without p rior notice. 2015 NEUT RIK . ALL RIGHTS RESERVE D. NEUTRIK are r egistered trademark.
I I
® ®
©
Page 2
Slide the insert and the chuck (1) into the
housing (2).
Important:
Align the chuck by positioning the nose into (a)
the recess.
Pay attention to the guiding keyway!(b)
Fasten bushing by means of a fork wrench 7/8”
(SW 22), min. Torque 2.5 Nm (1.8 lb-ft).
D D
1.
a
2.
b
E E
Torque Value 2.5 Nm
Wrench size
7/8" (SW22)
FINISHED powerCON