
R
HANDLING INSTRUCTION
opticalCON Fiber Optic Connection System
®
DUO LITE
CAUTION: Laser radiation, do not stare into beam!
|
Do not disassemble the opticalCON DUO LITE cable connector if not necessary.
The automatic sealing shutter of the opticalCON avoids pollution of the inside located LCconnectors.
The dust proof design reduces cleaning to a minimum, if nevertheless necessary be aware that
improper cleaning can cause damage to the equipment.
A. Cable Connector Cleaning
Tools: ? 99% isopropyl alcohol (IPA) or cleaning fluid (FOCD-CF)
? Lint free wipes (FOCD-DW)
The primary concern with using IPA is that it be removed completely from the LC connector.
If the alcohol is allowed to evaporate slowly of the ferrule, it can leave residual material on the fiber core or cladding.
Disconnect both cable ends for safety reasons
1.
Invisible laser radiation may be emitted from
disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
Untight the connector bushing and remove carefully
2.
the insert of the connector housing.
Inspect the LC connectors with a fiberscope
3.
(CAS-FOCD)
Fold a lint-free wipe FOCD-DW into a square.
4.
Moisten one section of the wipe with one drop of the
5.
alcohol. Be sure that a portion of the wipe remains dry.
Wipe lightly the ferrule tip in the alcohol moistened
6.
portion of the wipe.
Immediately repeat this wiping action on the dry
section of the wipe to remove any residual alcohol.
Do not scrub the fiber against the wipe, doing so can
cause scratches.
Dispose the wipe, NEVER REUSE A WIPE.
7.
Inspect the connector again with a fiberscope
8.
(CAS-FOCD).
Repeat the process if necessary.
9.
After the cleaning procedure slide the connector insert
10.
back into the connector housing.
Align the key on the insert to the cutout of the metal
housing.
Screw both connector parts tight together.
11.
Page 1BDA 422

R
HANDLING INSTRUCTION
I opticalCON DUO LITE
B. Chassis Connector Maintenance
2.1
O
U
D
N
O
C
tical
p
o
Cleaning T
2.3
ool
1.
Wet cleaning using lint-free wipes
Remove LC connectors at the rear of the opticalCON
chassis and follow the instructions A. 3 to 9.
2.
Dry cleaning using FOCD-DC125
Remove Dust cap. Insert the stick of the cleaning
2.1
device.
Make sure that the insertion position is on the
2.2
bottom of the LC connector hole in order to hit the
sealing shutter release bar.
Push the outer shell to start cleaning the LC
2.3
connector end face.
A “pop” sound indicates end of cleaning process.
Remove the cleaning device and put dust cap over
2.4
the stick.
2.2
A
B
K
I
R
T
U
E
N
NEUT RIK AG LI T: +423 / 2 37 24 2 4 F: +4 23 / 232 53 93
NEUT RIK USA Inc. USA T: +1 704 / 9 72 30 50 F: +1 704 / 438 9 202
NEUT RIK UK Ltd. UK T: +44 198 3 / 811 441 F: +4 4 1983 / 811 439
NEUT RIK Vertri ebs G mbH DE / NL / AT/DK T: +49 813 1 / 280 890 F: +49 8131 / 280 830
NEUT RIK Fran ce FR T: +33 1 / 41 31 67 50 F : +33 1 / 4131 0511
NEUT RIK Tokyo Lt d. JP T: +81 3 / 3663 473 3 F : +81 3 / 366 3 479 6
NEUT RIK Hong K ong L td. HK T: +852 / 2 687 6 055 F: +8 52 / 268 7 605 2
NEUT RIK Indi a Pvt . Ltd . IND T: +91 / 982 05 43 4 24 F: +91 / 22 2616 3 540
Draft. Nr.: BDA 422 Update: 02.09.2014
www.neutrik.com
( )
I I
Data subject t o change without prior n otice. 2014 NEUTRIK . ALL RIGHTS RESERVE D. NEUTRIK are registered trademark.
©
® ®
R