A. Breakoutbox - Cleaning the chassis (front side)
Tools: ? Cleaning fluid FOCD-CF or 99% isopropyl alcohol (IPA)
The primary concern with using IPA is that it be removed completely from the LC connector. If the alcohol is allowed to evaporate slowly of the ferrule, it can leave residual material on the fiber core or cladding.
Breakoutbox
®
1.
Breakout Box
(Example: NO4SBB4D-PM-A)
Dry cleaning frontside of DUO & QUAD or MTP
Open the breakout box and clean the surface
1.
with a lint free wipe FOCD-DW. Remove dust cap. Insert the stick of the
2.
cleaning device FOCD-DC125. Make sure that the insertion position is on
3.
the bottom of the LC connector hole in order to hit the sealing shutter release bar. Push the outer shell to start cleaning the LC
4.
connector end face. A “pop” sound indicates end of cleaning
5.
process. Remove cleaning device and put dust cap on
6.
the stick.
3.
K
I
R
T
EU
N
2.
4.
“pop”
1.
2.
3.
4.
5.
®
Open the breakout box and clean the surface with a lint free wipe FOCD-DW. Remove dust cap and insert the tip of the dry cleaner FOCD-DCM. Guide the tip of the dry cleaner into the chassis housing. Rotate the plastic wheel to start the cleaning procedure. An endless lint free tape removes dust particle on the ferrule surface of the MTP
®
connector on the rear of the chassis. After cleaning procedure, remove dry cleaner and cover the tip with the dust cap.
3.
2.
IK
TR
EU
N
3.
FOCD-DC125
Plastic wheel
3.
FOCD-DCM
Page 1BDA 432
R
CLEANING INSTRUCTION
I opticalCON Breakoutbox
B. Cleaning the chassis (rear side)
Tools: ? Hex key No. 2
? Cleaning fluid FOCD-CF or 99% isopropyl alcohol (IPA) ? Lint free dry wipes FOCD-DW for fiber cleaning ? Fiberscope for inspect the connector (CAS-FOCD)
2.
3.
12 x Allen screws
1.
Open the breakout box and clean the surface
1.
with a lint free wipe FOCD-DW While using a hex key open the 12 allen screws
2.
and remove the plate with the connectors. Remove carefully the LC's from the rear side
3.
of the chassis connectors separately to avoid any possibly of concisions. Inspect the LC connectors with a fiberscope.
4.
Fold a lint-free wipe FOCD-DW into a square.
5.
Moisten on section of the wipe with one drop of
6.
isopropyl alcohol (IPA). Be sure that a protion of the wipe remains dry. Whipe lightly with a ferrule tip in the alcohol
7.
moistened portion of the wipe. Immediately repeat this wiping action on the dry section of the wipe to remove any residual IPA. Do not scrub the fiber against the wipe, doing so can cause scratches. Dispose the wipe, . Inspect the connector again with a fiberscope.
8.
Repeat the process if requidred.
9.
After cleaning procedure the LC connector
10.
NEVER REUSE A WIPE
re-connect into the opticalCON. Position the plate into the box again and screw it.
11.
5.
cleaning fluid
FOCD-CF FOCD-DW
NEUT RIK AG LI T: +423 / 2 37 24 2 4 F: +4 23 / 23 2 53 9 3 NEUT RIK USA In c. USA T: +1 704 / 9 72 30 50 F: +1 704 / 438 9 202 NEUT RIK UK Ltd. UK T: +44 198 3 / 811 44 1 F: +44 1983 / 811 43 9 NEUT RIK Vertriebs G mbH DE / NL / AT/DK T: +49 813 1 / 280 890 F: +49 8131 / 28 0 830 NEUT RIK France FR T: +33 1 / 41 31 67 50 F : +33 1 / 413 1 0511 NEUT RIK Tokyo Ltd. JP T: +81 3 / 3663 4733 F : +81 3 / 3663 4796 NEUT RIK Hong Kong Ltd. HK T: +852 / 26 87 60 55 F: +8 52 / 2687 6052 NEUT RIK Indi a Pvt. Ltd. IND T: +91 / 982 05 43 4 24 F : +91 / 2 2 261 63 54 0
Draft. Nr.: BDA 432 Update: 13.04.2015