R
HANDLING INSTRUCTION
®
opticalCON MTP Maintenance
|
®
MTP
www.neutrik.com
R
BDA 518

opticalCON MTP
CAUTION: Laser radiation, do not look directly into beam of light!
®
HANDLING INSTRUCTION
I
The sealing shutter mechanism of the opticalCON avoids contamination of the MTP ferrule locked inside.
®
The dust-proof design reduces maintenance intervals to a minimum; if nevertheless necessary,
follows the maintenance procedure below to avoid damages on the due to inpropes cleaning.
A. Connector Cleaning / Inspection
Intervall: every 500 matings recommended
Tools: Ÿ NEUTRIK MTP service Tool (FOCD-STM)
Ÿ Dry Cleaner MPO/MTP (FOCD-DCM)
Ÿ optical fiber video probe
opticalCON
A
®
®
Disconnect both cable ends for safety reasons.
1.
In visibl e laser radia tion may be emit ted fro m
disconnected fibers or connectors. Do not stare into
beams or view directly with optical instruments.
B
Service tool (FOCD-STM)
optical fiber Microscope
opticalCON
2.
Remove dust cap from the connector (A) and mount
NEUTRIK FOCD-STM inspection tool on it until it is
locked (B).
3.
C
Prepare the optical fiber video probe with the
correlate singlemode or multimode tip (C).
Under the following QR-code you can find a list with
appropriate video probs and tips.
2
BDA 518

HANDLING INSTRUCTION
opticalCON MTP
I
®
D
opticalCON
Insert the video probe tool into our NEUTRIK FOCD-
4.
STM service tool (D).
F
opticalCON
E
G
To inspect the MTP ferrule surface focus the video
5.
probe by rotating the focus wheel (E) and to switch
(F) or move to the next ferrule rotate the wheels on
the tip (G).
®
6.
Clean the MTP surface with the Dry Cleaner over
the NEUTRIK MTP service tool.
7.
Push back and forth the dry cleaner to start the
opticalCON
cleaning procedure (H). An endless lint free tape
removes dust particle on the ferrule surface of the
®
MTP connector.
H
8.
Check the condition of the MTP ferrule surface
®
®
®
again and if necessary repeat step 7.
Dry Cleaner MPO/MTP (FOCD-DCM)
®
Du r i n g i ns pe c t i o n pr o c e d u re , m a k e su re
th a t eac h fe r ru le is co m p le t e l y fr e e of dus t .
As a re f er e n c e th e fer r ul e ha s to loo k as
il l us tr a te d on Pi c t u re B.
Picture A: Picture B:
BDA 518
3

R
HANDLING INSTRUCTION
I
B. Chassis Cleaning
opticalCON
I opticalCON MTP
9.
®
After the cleaning procedure unlock the NEUTRIK
inspection tool (I).
Dry cleaning using FOCD-DCM
A
Dry Cleaner (FOCD-DCM)
Remove dust cap and insert the tip of the dry
1.
cleaning cleaner.
Guide the tip to the dry cleaner into the chassis
2.
housing (A).
B
Push back and forth the dry cleaner to start the
3.
cleaning procedure (B). An endless lint free tape
removes dust particle on the ferrule surface of the
®
MTP connector.
4.
After cleaning procedure, remove dry cleaner
and coves the tip with the dust cap.
Find more details of opticalCON on www.neutrik.com.
NEUTRIK AG LI T: +423 / 237 24 2 4 F: +423 / 232 53 93
NEUTRIK USA Inc. USA T: +1 704 / 972 3050 F: +1 704 / 438 920 2
NEUTRIK UK Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439
NEUTRIK Vertriebs GmbH DE / NL / AT/DK T: +49 813 1 / 280 89 0 F: +49 8131 / 280 83 0
Draft. Nr.: BDA 518 Update: 20.03.2017 Data subject to cha nge without prior notic e. 20 17 NEUTRIK . ALL RIGHTS R ESERVED. NEUTRIK is a r egistered trademark.
( )
I I
©
www.neutrik .com
NEUTRIK France FR T: +33 1 / 4131 675 0 F: +33 1 / 4 131 0511
NEUTRIK Tokyo Ltd. JP T: +81 3 / 366 3 4733 F: +81 3 / 3663 4796
NEUTRIK Hong Kong Ltd. HK T: +852 / 2 687 6055 F: +852 / 2687 6052
NEUTRIK India Pvt. Ltd. IND T: +91 / 982 05 43 42 4 F: +91 / 22 261 63 540
® ®
- 4 -
R