R
ASSEMBLY INSTRUCTION
NE8MC6
A
|
etherCON Cable Connector CAT 6
Slide the boot onto the cable.
A
Terminate RJ45 connector on the cable.
B
See following pages.
Press the locking latch of the RJ45 and place the
two adapters onto the RJ45.
C
B
Pay attention: Hold the brackets together.
Put chuck onto the cable.
D
Attention: Pay attention to the guiding key.
C
Slide RJ45 and chuck together into the housing.
Pay attention to the plug latch which has to be on the
E
opposite side of the key.
Finish the assembly by turning the bushing onto the
F
connector. Screw bushing fully up to the end.
D
E
Key
Suitable cables:
AWG 22 to 28 soldid or stranded c
insulation. O.D. 0.037” / 0.95 mm to 0.047” / 1.07 mm.
Jacket:
O.D. 0.22” / 5.5 mm to 0.25” / 6.5 mm
onductors with an
F
NEUTRIK AG
NEUTRIK Zürich AG
NEUTRIK USA Inc.
NEUTRIK UK Ltd.
Draft. Nr.: BDA 194 Update: 20.05.2010/ 3102M1581
()
LI
CH
USA
UK
www.neutrik.com
T: F:
+423 / 23724 24 +423 / 232 53 93
T: F:
+41 44 / 736 5010 +41 44 /736 5011
T: F:
+1 732 /901 9488 +1 732 /901 9608
T: F:
+44 1983 /811 441 +44 1983 /811 439
II
Data subject tochange without prior notice. 2010 NEUTRIK . ALLRIGHTS RESERVED.©
NEUTRIK
NEUTRIK France
NEUTRIK Tokyo Ltd.
NEUTRIK
Vertriebs GmbH
®
Ltd.Hong Kong
DE /NL /AT
FR
JP
HK
T: F:
+49 8131 /280 890 +49 8131 /280 830
T: F:
+33 1 / 4131 6750 +33 1 / 4131 0511
T: F:
+81 3 / 3663 4733 +81 3 / 3663 4796
T: F:
+852 / 2687 6055 +852 / 2687 6052
R
R
ASSEMBLY INSTRUCTION etherCON CAT 6
Terminate RJ45 connector on the cable.
B
I
1
White-Green
2
Green
3
White-Orange
4
Blue
5
White-Blue
6
Orange
7
White-Brown
8
Brown
Consider cable end termination usually straight - thru
cable acc. TIA 568A.
1
Assembly of wire, load bar and plug.
2
Strip outer jacket 20 mm long.
3
4
5
Separate pairs in bundles.
Straighten and separate into individual leads.
Organize leads into proper order and trim edge to be
even.
6
BDA 194 20.05.2010
I
Wire lead ends shown organized and trimmed.
-2-
R