R
ASSEMBLY INSTRUCTION
NC * FRX & NC * MRX XLR Ca ble Co nne ct or
A
|
Slide the boot onto the cable.
A
B
Prepare cable as shown.
Insert wires into the terminals and solder
C
them.
Position the sleeve over the cables.
D
B
18
4
Slide insert into the housing until it snaps
E
in.
Align insert with housing.
Position the cable.
F
C
Slide the chuck into the housing.
G
Pay attention to position chuck as shown.
D
E
G
F
°
°
90
90
°
°
5
5
4
4
0
0
-1
45
°
-
-
9
9
0°
0°
-45°
-45°
Page 1
R
ASSEMBLY INSTRUCTION NC*FRX / NC*MRX
I
I
H
Position the cover.
Before placing the cover choose the orientation
of cable outlet by turning housing.
Finish the assembly by turning the bushing
I
onto the connector.
H
Disassembly of the insert
A
C
Remove cover and chuck.
A
Push latch and turn housing approx. a half
B
turn until housing can be separated.
C
Lift the locking clip by help of a screw driver.
Remove insert.
D
B
Clip arrangement!
D
NEUTRIK AG LI T: +423 / 237 24 2 4 F: +423 / 232 53 93
NEUTRIK USA Inc. USA T: +1 704 / 972 3050 F: +1 704 / 438 9202
NEUTRIK UK Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439
NEUTRIK Vertriebs Gm bH DE / NL / AT/DK T: +49 8131 / 280 890 F: +49 8131 / 280 830
Draft. Nr.: BDA 173-0 / 3102M1 441 Update: 13.07.2011
( )
www.neutrik.com
I I
Data subject t o change without prior n otice. 2011 NEUTRIK . ALL RIG HTS RESERVED.
Page 2
NEUTRIK France FR T: +33 1 / 4131 6750 F: +33 1 / 4131 0511
NEUTRIK Tokyo Ltd. JP T: +81 3 / 3663 4733 F: +81 3 / 3663 4796
NEUTRIK Hong Kon g Ltd. HK T: +852 / 2687 6055 F: +852 / 2687 605 2
©
®
R