ASSEMBLY INSTRUCTION
miniCON
A
B
For crimp ferrule only.
When using standard chuck twist shield.
Only crimp
C
version:
reduction ferrule 2
reduction ferrule 1
15.0 mm
[0.590"]
crimp ferrule
|
Cable Connector
Standard & Crimp Version
A
Put bushing onto the cable.
Prepare cable as shown.
B
C
Only crimp version:
Slide crimp ferrule onto the cable.
- Crimp ferrule, only for cable O.D. 4.5 - 6.0 mm
- Crimp ferrule + reduction ferrule 1,
4.0 mm
[0.157"]
for cable O.D. 3.3 - 4.4 mm
- Crimp ferrule + reduction ferrule 2,
for cable O.D. 2.5 - 3.2 mm
Wire contacts:
D
Solder standard contacts.
For crimp contact use our HX-CONTACT crimp tool
with the appropriate positioner (see ordering info)
Snap the contacts into the insert.
E
Contact Arragement:
Male Female
2
9
G
3
1210
8
4
7
11
5
6
2
9
G
10
3
12
8
4
7
11
5
6
D
E
Only crimp version:
G
G
Press the distance sleeve / chuck onto the cable.
F
Slide insert and chuck into the housing and fasten
G
the bushing.
G
F
G
F
Same procedere for MSC & MMC housing with
female or male inserts!
NEUTRIK AG
NEUTRIK Zürich AG
NEUTRIK USA Inc.
NEUTRIK UK Ltd.
Draft. Nr.: BDA 126 Update: 29.09.20093102M1231/
()
www.neutrik.com
LI
CH
USA
UK
T: F:
+423 / 237 24 24 +423 / 232 53 93
T: F:
+41 44 / 736 5010 +41 44 / 736 5011
T: F:
+1 732 / 901 9488 +1 732 / 901 9608
T: F:
+44 1983 / 811 441 +44 1983 / 811 439
II
NEUTRIK
NEUTRIK France
NEUTRIK Tokyo Ltd.
NEUTRIK
Data subject to change without prior notice. 2009 NEUTRIK . ALL RIGHTS RESERVED.©
Vertriebs GmbH
Ltd.Hong Kong
®
DE /NL /AT
FR
JP
HK
T: F:
+49 8131 / 280 890 +49 8131 / 280 830
T: F:
+33 1 / 4131 6750 +33 1 / 4131 0511
T: F:
+81 3 / 3663 4733 +81 3 / 3663 4796
T: F:
+852 / 2687 6055 +852 / 2687 6052