R
CLEANING INSTRUCTION
opticalCON Chassis Connector
®
Cleaning Adapter FOCD-STC & FOID-STQC
LASER
1
The sealing shutter mechanism of the opticalCON avoids contamination of the LC ferrule locked inside.
The dust-proof design reduces maintenance intervals to a minimum; if nevertheless necessary,
follows the maintenance procedure below to avoid damages on the due to inpropes cleaning.
Cassis Cleaning / Inspection
Intervall: every 500 matings recommended
Tools: Neutrik Chassis Cleaning Adapter: FOCD-STC / FOID-STQC
Dry Cleaner: FOCD-DC125, FOCD-DCM
Optical fiber video probe
CAUTION:
Laser radiation, do not look directly into beam of light!
®
®
opticalCON DUO Chassis Cleaning
1.
Insert the FOCD-STC in to the Neutrik opticalCON
A
A
®
®
NO2-4FDW-A-* chassis.
Use the appropriate tip for the video probe
according to the matrix on the last page.
Then inspect the LC surface.
Video probe tip
After inspection clean the LC surface with the Dry
B
B
Cleaner 1.25 mm.
Check the condition of the LC ferrule surface again
and if necessary, repeat step A and B .
Dry Cleaner
Page 1BDA 636 V1

opticalCON Chassis Cleaning Instruction
opticalCON QUAD Chassis Cleaning
2.
Insert the Inspection Adapter into the FOCD-STC.
C
D
C
Insert the unit into the Neutrik opticalCON chassis
D
®
®
NO4-FDW-A
Use the appropriate tip for the video probe
E
E
according to the matrix on the last page.
F
G
Dry Cleaner
Then inspect the LC surface.
After inspection remove the inspection adapter and
F
clean the LC surface with the Dry Cleaner 1.25 mm
Check the condition of the LC ferrule surface again
and if necessary, repeat step C and D.
®
3.
opticalCON MTP Chassis Cleaning
Insert the FOCD-STC in to the Neutrik opticalCON
G
®
NO12FDW-A or NO24FDW-A chassis.
Use the appropriate tip for the video probe
according to the matrix on the last page.
®
Video probe tip
Attention:
Due to the 8-degree angled MTP singlemode
®
ferrule. It is not possible to inspect singlemode
®
MTP ferrules.
Currently only MTP Multimode ferrules can be
®
inspected.
Page 2BDA 636 V1

opticalCON Chassis Cleaning Instruction
H
H
After inspection clean the MTP surface with the
Dry Cleaner MPO / MTP .
®
Check the condition of the MTP surface again and
®
®
if necessary, repeat step G and H.
CLE A NIN G MATR IX
Servic e Chassi s Vid eo Approp riate Brand Dry Clea ning
Tool Probe Tip Tool
FOCD -STC
NO2-4FDW-A
NO2-4FDW-1-A
FOID -STQC
NO4FDW-A
DI-1000-B2-NT
DI-1000-WIFI
DI-2000-B2-*
CI-1100-A2
FBP-5000
FBPP5000i
FIT-FC-KIT1
DI-1000-B2-NT
DI-1000-WIFI
DI-2000-B2-*
CI-1100-A2
FBP-5000
FBPP5000i
FIT-FC-KIT1
PT2-LC/PC/F-1
FBPT-LC
PT2-WO/ADAPT-3/N
FBPP-BAP3
LIGHTEL
VIAVI/JDSU
FOCD-DC125
LIGHTEL
VIAVI/JDSU
FOCD -STC
DI-1000-B2-NT
DI-1000-WIFI
DI-2000-B2-*
NO12FDW-A
CI-1100-A2
NO24FDW-A
FBP-5000
FBPP5000i
FIT-FC-KIT1
More I nf orma t i on on t h e www.neu t rik.c o m
https://www.neutrik.com/en/products/video/opticalcon
Neutrik AG LI T: +423 / 2 37 24 24 F: +423 / 2 32 53 93
Neutrik Americas Inc. USA T: +1 704 / 972 3050 F: +1 704 / 438 920 2
( )
Neutrik UK Ltd. UK T: +44 1983 / 811 441 F: +44 1983 / 811 439
Neutrik Vertriebs GmbH DE / NL / AT/DK T: +49 8131 / 280 890 F: +49 8131 / 280 8 30
Draft. Nr.: BDA 636 V2 Update: 2022-04-21
I I
www.neutrik.com
Data subject t o change with out prior noti ce. 2022 NE UTRIK . NEUTRIK and optica lCON are registere d trademark of N eutrik AG. ALL RIGHTS RESERVED.
Page 3
PT2-MTP/PC/OCON-XY-EXT
only MULTIMODE
FBPT-MTP-L
only MULTIMODE
Neutrik France FR T: +33 1 / 4131 675 0 F: +33 1 / 4131 0511
Neutrik Tokyo Ltd. JP T: +81 3 / 3 663 4733 F: +81 3 / 3663 4796
Neutrik Hong Ko ng Ltd. HK T: +852 / 2687 6055 F: + 852 / 2687 6052
©
® ® ®
LIGHTEL
VIAVI/JDSU
FOCD-DCM