NE8FDY-C6
Assembly Instructions
Cable preparation
A
Twist the
screen
40 mm
1. 2. 3. 4. 5.
Shielding
B
S-FTP SF-UTP F-UTP
EtherCon Receptacle
®
2-1
8-7
4-5
6-3
C D
Cable pairs separation Cable mount
6-3
4-5
8-7
Position wires acc. label Fix wires
E
1. Position the
cable!
2-1
F
2. Trimming!
Cable tie
8-9 mm
-1-
![](/html/cd/cde1/cde10343dab79e1269580a44323fb94f96dfec1d14110972f1160f469d3fe5e3/bg2.png)
Cover assembly
G H
2.
Break out!
1.
Connect the screen
Hang up!
Cut!
Assembly the adapter
I J
Insert until it
snaps in
Assembly the chassis
K
Press
down!
Snap in
Grounding option
Insert contact only if screen should
be connected to front panel
Finish
L
Please fix the cable additionally.Attention: Before assembly secure the housing in the device.
Note for Right-Angel Version
Working steps same as above.
Except:
Step B - References
to step B and bend
the reinforcement metal right
angle below.
Step G - The cable outlet must not be
interrupted.
NEUTRIK AG NEUTRIK Zürich AG NEUTRIK (UK) Ltd. NEUTRIK USA INC. NEUTRIK Tokyo Ltd. NEUTRIK France NEUTRIK Vertriebs GmbH
Liechtenstein Switzerland Great Britain USA Japan France Germany /Netherlands /Austria
Tel.: +423/237 24 24 Tel.: +41 44/736 5010 Tel.: +44 1983/811 441 Tel.: +1 732/901 9488 Tel.: +81 3/3663 4733 Tel.: +33 1/4131 6750 Tel.: +49 8131/28 08 90
Fax: +423/232 53 93 Fax: +41 44/736 5011 Fax: +44 1983/811 439 Fax: +1 732/901 9608 Fax: +81 3/3663 4796 Fax: +33 1/4131 0511 Fax: +49 8131/28 08-30
www.neutrik.com
Draft. Nr.: BDA 188
Update:
Data subject to change without prior notice. 2007 NEUTRIK . ALL RIGHTS RESERVED.©
09.02.2007
/ 3102M1561
®
R
N
-2-
E
U
CONNECTING THE WORLD
T
B
I
R
K
G
R