Neumann-Information 1
Re: Disassemblina and Cleanina of Neumann Condenser Microohones
The disassembli- of the microphones in amplifiers and capsule head is
described in
microphone.
Attention:
-~It is by no means allowed to tauch with the
ing elements
impedance
and
dirt
voltages.
the operating instructions
for
the
connection
Parts
quantities tan diminish the isolation
of the
circuit
of the capsule head. Also the other high
may not be touched.
which
are delivered
finger
88 043
the contact and isolat-
I
with each
4lready minimum grease
figures
and Cause noise
April 1988
Cleaning the microphone amplifier:
Existing dirt on components and contacts tan be removed by means of a
soft brush using
Microphone capsules:
-
The microphone capsules of U 89 i, TLM 170 i and the KM . . . miniature microphones
0 Volt.
dirt
When microphone capsules had to be constructed in a way that the isolating
areas between
membrane Systems of U 67, U 87 (A) i, SM 69, SM 69 fet, USM 69 i, IJ 47 fet)
after a
membranes the capsule has
U 67, U 87 (A) i, U 47 fet microphones the 3 mounting
plate of the capsule head have
assembly tan be
At the microphones SM 69, SM 69 fet, USM 69 i the disassembly of the protect-
ing grille is more difficult:
The black dot on the upper
removed.
pressed
at
spring becomes visible which has also to be pressed backward, now the
complete
springs
assembly tan now easily be
- -
a detergent
are
constructed in a way that the total surface is connected to
For
this
reason
and atmospheric influences and should not be cleaned.
the
electrodes
long
period
of
Operation
removed from
Behind the opening a spring is visible, this spring has to be
back by approximately 1 mm,
the
front
side.
upper part
to be lost these should
Now the
of the
on the basis of
these microphones
could be
noise
to
be
removed from its protecting grille.
to
be
removed
the capsule head.
part
of the
the
grille
has
grille tan carefully
also be removed.
removed from
Freon, Kaltron or
are extremely insensitive
reached
voltages
grille
grille
to
the
by
dirt
may
and then the complete capsule
(position O”) has to be
tan then slightly be lifted
be
turned
be
The complete capsule
lower part
Frigen.
against
(the
large
occur. For
screws at
by 180°, then another
removed.
of the
double
cleaning the
the
To
prevent
grillle.
At t-he
lower
the
CHARLOl-TENSTRASSE 3 D-i000 BERLIN 61 POSTFACH 610469 TELEGRAMM: NEUMANNACUSTIC
TELEFON: (030) 25993-0 TELEFAX: (030) 25993-108 TELEX: 184595 NEUAK D
pto.
Printed in Germany
Cleaning the membrane:
Every membrane is carefully brushed with a
water.
soft blott ing-Paper. This
the capsule
this method have to be exchanged.
Cleaning the membrane by means of
These solvents
For careful cleaning then no time remains and inhomogenit
on the membrane;
solvents could
solvents tan
condense below the membrane which cannot be
Besides that
of the membrane is influenced.
The
water
with the dissolved
is really
are too
clean. Those capsules which cannot be
thinly liquid and fugitive.
also transport dirt
also cool
the
use of solvents
down the
procedure
membrane strongly
dirt
has
solvents is not allowed
below the membrane fixing
bears
very
tan then be
to
be
repeated several
removed from there.
the
risk
soft brush with distilled
removed with very
and then humidity tan
that the mechanical tension
cleaned by
ives
may
rinqs:
times unt
rema in
il