Network Technologies ST-C5USBV-300M, ST-C5USBV-300, ST-C5USBVA-300, ST-C5USBVA-300M Installation Manual

Page 1
NTI
NETWORK
R
TECHNOLOGIES INCORPORATED
1275 Danner Dr Aurora, OH 44202
www.networktechinc.com
XTENDEX®Series
Tel:330-562-7070 Fax:330-562-1999
ST-C5USBV-300(M)
ST-C5USBVA-300(M)
300 FOOT USB KVM EXTENDER
Installation and Operation Manual
UMTINT-xx-MM (Module cable- sold separately)
ST-C5USBV-300 (Desktop Model)
ST-C5USBV-300M (Rackmount Module)
MAN010 Rev 5/5/08
Page 2
TRADEMARK
XTENDEX is a registered trademark of Network Technologies Inc in the U.S. and other countries.
COPYRIGHT
Copyright © 2007,2008 by Network Technologies Inc, all rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202. For more information please contact Network Technologies Inc at (800) 742-8324 (800-RGB-TECH) or (330) 562-7070.
CHANGES
The material in this guide is for information only and is subject to change without notice. Network Technologies Inc reserves the right to make changes in the product design without reservation and without notification to its users.
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground, outdoors or between buildings.
!
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
MAN010 Rev 5/5/08
Page 3
Table of Contents
Introduction...................................................................................................................................................................... 1
Features....................................................................................................................................................................... 1
Types of User Input Devices Supported:..................................................................................................................... 1
Operating Systems Supported ....................................................................................................................................2
Limitations.................................................................................................................................................................... 2
Materials .......................................................................................................................................................................... 2
Features and Functions................................................................................................................................................... 3
Preparation for Installation ..............................................................................................................................................4
Installation ....................................................................................................................................................................... 5
The Local Unit.............................................................................................................................................................. 5
Connect to the CPU.................................................................................................................................................. 5
Connect the Local Devices .......................................................................................................................................6
Connect the CAT5 Cable.......................................................................................................................................... 7
The Remote Unit.......................................................................................................................................................... 7
Connect the Remote Devices ...................................................................................................................................7
Connect the CAT5 cable........................................................................................................................................... 9
Rackmount Modules (optional)................................................................................................................................... 9
Mount the ST-C5RCK-12 Rackmount Extender Module Tray.................................................................................. 9
Connect the CPU .................................................................................................................................................... 11
Connect the Devices............................................................................................................................................... 11
Connect the CAT5 cable......................................................................................................................................... 12
Plug-in and Boot Up................................................................................................................................................... 13
Command Mode............................................................................................................................................................14
MAC Mode................................................................................................................................................................. 15
DDC Support .................................................................................................................................................................15
Common Applications ...................................................................................................................................................16
Technical Specifications................................................................................................................................................ 17
Interconnection Cable Wiring Method ........................................................................................................................... 18
Keyboard Translation .................................................................................................................................................... 19
Key Equivalents .........................................................................................................................................................19
SUN’s 16 Extra Keys ................................................................................................................................................. 19
Troubleshooting............................................................................................................................................................. 21
Index..............................................................................................................................................................................22
Warranty Information..................................................................................................................................................... 22
Table of Figures
Figure 1- Connect the Local Unit to a CPU........................................................................................................................................ 5
Figure 2- Local unit with audio support connects to CPU ..................................................................................................................6
Figure 3- Connect local user devices to the Local Unit...................................................................................................................... 6
Figure 4- Connect stereo speakers to XTENDEX Local Unit with audio support............................................................................... 7
Figure 5- Connect the CAT5 cable to the Local Unit.......................................................................................................................... 7
Figure 6- Connect the Monitor and Devices to the Remote Unit ........................................................................................................ 8
Figure 7- Connect remote self-powered speakers to Remote Unit ....................................................................................................8
Figure 8- Connect CAT5 cable to the Remote Unit............................................................................................................................ 9
Figure 9- Mount ST-C5RCK-12 Extender Module Tray to a rack....................................................................................................... 9
Figure 10- Secure each module to the tray...................................................................................................................................... 10
Figure 11- Secure each power supply to the tray ............................................................................................................................10
Figure 12- Connect cable between CPU and module...................................................................................................................... 11
Figure 13- Connect cable between user and module ......................................................................................................................11
Figure 14- Connect the CAT5 cable between the Local and Remote Units ..................................................................................... 12
Figure 15- Connect AC adapters ..................................................................................................................................................... 13
Figure 16- MAC LED........................................................................................................................................................................15
Figure 17- Examples of common applications for the ST-C5USBV-300 USB KVM Extender.......................................................... 16
Figure 18- Pin positions in female RJ45 connector.......................................................................................................................... 18
Figure 19- Keyboard Layouts........................................................................................................................................................... 20
ii
Page 4
INTRODUCTION
The ST-C5USBV-300 USB Extender (XTENDEX) is designed to enable the relocation of a monitor, USB keyboard, and USB mouse from a USB CPU or NTI USB KVM switch by as much as 300 feet via CAT5 cable in addition to having a monitor, USB keyboard, and USB mouse connected locally. It is extremely simple to install and has been thoroughly tested to insure reliable performance. Through the use of Category 5 shielded or unshielded twisted-pair cable (STP/UTP) or Category 6 unshielded twisted-pair cable (UTP), it is possible to economically increase the flexibility of a computer system.
Options: Audio Support
“A” to the model number (i.e. ST-C5USBV
Rackmount Modules
add “M” to the model number (i.e. ST-C5USBVA-300 Rackmount Extender Module Tray (see page 9).
*NTI ST-C5RCK-12 Rackmount Extender Tray required (sold separately)
- The ST-C5USBV-300 can be ordered to include support for extending self-powered stereo speakers by adding
A-300)
- The ST-C5USBV-300/USBVA-300 can be ordered as rackmount modules (Remote and/or Local Units)-
M). When ordering rackmount modules, also order the ST-C5RCK-12
Model Mounting Method Audio Support
ST-C5USBV-300 Desktop N ST-C5USBVA-300 Desktop Y ST-C5USBV-300M Rackmount* N ST-C5USBVA-300M Rackmount* Y
Features
Allows the placement of a monitor, USB keyboard, and USB mouse in a location where only these
parts are needed without having the CPU there too, taking up valuable space and adding to room noise.
Provides crisp and clear resolution when used in accordance with the chart below:
CAT5/5eSTP CAT5/5E/6 UTP cable Resolution Cable length Resolution Cable length
1024 x 768 /60Hz 300 feet 1024 x 768 /60Hz 300 feet 1280 x 1024 /60Hz 150 feet 1600 x 1200 /60Hz 150 feet
Video quality is easily adjusted using keyboard controls
Installation can be between a CPU and devices (keyboard, mouse, and monitor), between a CPU and
NTI USB switch, or between a NTI USB switch and devices.
Allows hot-plugging of keyboards and mice
DDC Support (Local monitor only)
1600 x 1200 /60Hz 100 feet 1920 x 1440 /60Hz 100 feet
Types of User Input Devices Supported:
Compatible with all video resolutions up to WUXGA (dependant upon CAT5/5e/6 extension distance)
All NTI USB switches
Microsoft, Logitech or Kensington Wheelmouse or Trackball on MAC CPUs with manufacturer's drivers
USB keyboard with Windows® layout
USB keyboard with SUN layout
USB keyboard with MAC layout
USB Mouse - (up to 3 buttons)
USB IntelliMouse® (scrollwheel)
Logitech Cordless Elite Duo keyboard and mouse
Crystal Vision keyboard with touchpad
Gyration keyboard and mouse
NTI USB-PS/2 Adapter
NTI USB-SUN Adapter
Logitech wireless (S510, EX110, diNovo, LX10)
Belkin wireless F8E832-BNDL
Kensington wireless (64379)
MS Wireless Optical Desktop (3000 and 4000)
HP P2360AA
Fellowes wireless keyboard (KBR0108) with mouse (MSR0238T)
Creative Desktop Wireless 8000
1
Page 5
Operating Systems Supported
Windows 98SE • Linux 7.1 2.2 Kernel or greater
Windows 2000 • Sun-Solaris 8 or greater
Windows ME • MAC OS 9.1 or greater
Window XP • HP UNIX J5000
Window Vista • Free BSD
Limitations
The XTENDEX will only work with USB keyboards and mice, other USB devices are not supported.
PS/2 devices can be connected to the XTENDEX through an NTI USB-PS/2 adapter, however the translation keys described
on page 15 will not function in this application.
The XTENDEX can be used between two cascaded NTI switches, but the master switch in the configuration will not be able
to list the CPUs connected to the extended slave. The OSD menu in the extended slave would have to be used to monitor CPUs connected to it. (This can be done by configuring command mode for the slave switch with an Alternate OSD Command Sequence).
MATERIALS
Materials supplied with this kit:
9 NTI ST-C5USBV-300 USB Extender Local Unit 9 NTI ST-C5USBV-300 USB Extender Remote Unit 9 2-120VAC or 240VAC 50 or 60Hz-9VDC/1A AC Adapters 9 CD with a pdf file of this owner's manual 9 Power supply mounting bracket (ST-C5USBV-300M or ST-C5USBVA-300M only)
Additional materials may need to be ordered, depending upon the configuration :
¾ Video adapter for connection between the Local and a non-VGA SUN CPU (13W3M-15HDF) ¾ USBVEXT-3, 6, 10 (15HD Male-to-Female and USB Type A Male-to-Female Extension cable) if the Local Unit will be located
further than 15" from the CPU or KVM switch
¾ CAT5/5e shielded/unshielded twisted-pair cable(s) terminated with RJ45 connectors wired straight thru- pin 1 to pin 1, etc.
(see pg. 14 for proper EIA/TIA 568B wiring method)
-OR-
CAT6 unshielded twisted-pair cable(s) terminated with RJ45 connectors wired straight thru- pin 1 to pin 1, etc. (see pg. 14 for proper EIA/TIA 568B wiring method)
For Rackmount Modules (ST-C5USBV-300M or ST-C5USBVA-300M) the following materials are
¾ UMTINT-xx-MM - male 26-PIN SCSI II to male 15-pin HD, male USB Type A- for connecting the Local Unit to a CPU-
available in 3, 6 and 10 foot lengths.
¾ UMTINT-xx-male 26-PIN SCSI II to female 15-pin HD, female USB Type A (x2)- for connecting the Local or Remote Unit to a
monitor, keyboard, and mouse- available in 3, 6, 10 and 15 foot lengths.
¾ UMATINT-xx-MM-male 26-PIN SCSI II to male 15-pin HD, male USB Type A, and 3.5mm stereo plug- for connecting the
Local Unit with audio support to a CPU- available in 3, 6 and 10 foot lengths.
¾ UMATINT-xx-male 26-PIN SCSI II to female 15-pin HD, female USB Type A (x2), and 3.5mm stereo jack- for connecting the
Local or Remote Unit with audio support to a monitor, keyboard, mouse, and stereo speakers- available in 3, 6, 10 and 15 foot lengths.
Contact your nearest NTI distributor or NTI directly for all of your KVM needs at 800-742-8324 (800-RGB-TECH) in US & Canada or 330-562-7070 (Worldwide) or at our website at http://www.networktechinc.com and we will be happy to be of assistance.
required- not supplied:
2
Page 6
FEATURES AND FUNCTIONS
2
1
7
2b
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
3
- +
NTI
Network Technologies Inc
XTENDEX
(Front View)
R
USB
45 6
R
(Rear View)
XTENDEX USB
Network Technologies Inc
NTI
-
+
5
2
NTI
XTENDEX
ST-C5USBVA-300M
REMOTE UNIT
MAC
CAT5
ST-C5USBVA-300 (Remote Unit)
- +
NTI
Network Technologies Inc
USB
XTENDEX
(Front View)
2a
R
8
XTENDEX USB
Network Technologies Inc
NTI
R
(Rear View)
9
ST-C5USBVA-300M Remote Module
6
-
+
Front and Rear Views
NTI
XTENDEX
ST-C5USBVA-300M
LOCAL UNIT
2
2
10
CAT5
11 12
ST-C5USBVA-300 (Local Unit)
Audio Jack- 3.5mm stereo audio jack- for connecting to remote speakers (ST-C5USBVA-300 only) CAT5- RJ45 female for connection of CAT5 cable between Local Unit and Remote Unit 2a. Green LED- power indicator- illuminates when power has been supplied to the unit 2b. Yellow LED-communication indicator- blinks when there is valid communication between the Local and Remote Units. Monitor (symbol)-15HD female for connection of video cable from remote monitor USB DEVICES- USB type A female for connection of remote user USB device(s) MAC LED- for visual indication of connection to a MAC CPU 9VDC- connection jack for AC adapter Audio Jack- 3.5mm stereo audio jack- for connecting to local speakers (ST-C5USBVA-300 only) Monitor- 15HD female for connection of video cable from local monitor USB DEVICES- USB Type A female for connection of local user USB device(s) Video Cable- 15HD male for connection to video connector of CPU Devices Cable- USB Type A male connector for connection to CPU Audio Plug- 3.5mm stereo audio plug- for connecting to CPU audio line out (ST-C5USBVA-300 only) USER- .05 SCSI II Female- for connecting cable between module and the user devices CPU- .05 SCSI II Female- for connecting cable between the module and the CPU
R
R
USB
R
R
USB
USER
9V
R
1.5 A
NTI
1275 Danner Dr Aurora, OH 44202 Tel:330-562- 7070 Fax:330-562 -1999
www.networktechinc.c om
ST-C5USBVA-300 M
USER
R
1.5 A
NTI
1275 Danner Dr Aurora, OH 44 202 Tel:330-562- 7070 Fax:330-562 -1999
www.networktechin c.com
ST-C5USBVA-300 M
CPU
9V
R E M O T E
U N
I
T
L 0 C A L
U N
I
T
ST-C5USBVA-300M Local Module Front and Rear Views
13
6
14
13
6
3
Page 7
PREPARATION FOR INSTALLATION
A location should be chosen for the monitor, mouse, and keyboard that also has space to mount the Remote Unit within the
distance provided by the cables from the monitor, mouse, and keyboard. If extension cables are needed, contact NTI for the cables required. If a local user will be connected, a proper location must be chosen for these devices too.
The CAT5 cable(s) must be run to the locations where the Remote and Local Units will be placed. Be careful to route the
cables away from any sources of magnetic fields or electrical interference that might reduce the quality of the video signal (i.e. AC motors, welding equipment, etc.). outlets, it will be necessary to obtain male-to-male straight through connection cables long enough to reach from the wall outlets to the mounting locations of the Remote and Local Units.
A properly grounded, polarized, and preferably surge-protected 120V or 240V electrical outlet (depending on the AC adapter
being used) must be installed close enough to the mounting location of the Remote Unit and monitor to plug them into.
All cables should be installed in a fashion that will avoid stress on their connections to the equipment. Extended lengths of
cable hanging from a connection may interfere with the quality of that connection. Secure cables as needed to prevent this.
Properly shut down and disconnect the power of the CPU and monitor. Disconnect the monitor, keyboard, and mouse. If
other equipment is involved whose connections are being interrupted, be sure to refer to the instruction manuals for that equipment for proper disconnection and re-connection procedures before proceeding.
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground, outdoors or between buildings.
!
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
NOTE: If CAT5 cable is already installed in the wall and there are RJ45 wall
4
Page 8
INSTALLATION
The Local Unit
Connect to the CPU
1. Plug the cables of the Local Unit into the back of the CPU. (See Fig. 1.)
a) Connect the blue 15HD cable from the Local Unit to the female VGA port on the back of the CPU.
b) Connect the USB Type A cable from the Local Unit to a female USB Type A port on the back of the CPU.
Note: If a SUN CPU is being connected, depending upon the video connector of the SUN CPU, it may be necessary to attach an NTI #13W3M-15HDF (SUN video port-to-VGA adapter) to the video port on the CPU first, and then connect the video cable to the adapter.
USB CPU
Figure 1- Connect the Local Unit to a CPU
c) If the Local Unit has Audio support (ST-C5USBVA-300 only), connect the black 3.5mm stereo plug into the "line
out", "speaker", or "headphones" jack on the back of the CPU. (See Fig. 2)
Notes: If all 3 jacks are available, use the jack marked "line out".
The "line out" jack is typically lime green and may be marked with this symbol
The "speaker" jack is typically orange, and may be marked with this symbol
The "headphones" jack may be marked with this symbol
USB Type A male
(BLUE- VIDEO)
15HD male Video Connector
Sun 13W3 Video Connector
R
NTI
Network Technologies Inc
XTENDEX
(Rear View)
ST-C5USBV-300 Local Unit
USB
-
+
5
Page 9
AUDIO CONNECTOR
ONE WILL BE MARKED "line
out" ,"spkr", "headphones"
OR WITH THIS SYMBOL
line out
USB CPU
Figure 2- Local unit with audio support connects to CPU
USB Type A male
(BLUE- VIDEO)
(BLACK- AUDIO)
3.5mm Stereo Plug
USB
R
ST-C5USBVA-300 Local Unit
(Rear View)
15HD male Video Connector
Connect the Local Devices
If desired, connect the local user devices to the Local Unit as shown in Fig. 3.
1. Connect a USB keyboard and mouse to the USB type A female connectors on the Local Unit.
2. Connect a monitor to the 15HD female connector on the Local Unit.
15HD Female Video Connector
15HD male Video Connector
(Front View)
-
ST-C5USBV-300 (Local Unit)
(Rear View)
+
R
NTI
Network Technologies Inc
XTENDEX USB
Cable to CPU
XTENDE X
USB
Network Technologies Inc
NTI
R
USB Type A male
VGA
Multi-Scan
Monitor
USB Type A Female
-
+
USB Type A
male connectors
USB Keyboard
XTENDE X
Network Technologies Inc
NTI
-
+
USB
Mouse
Figure 3- Connect local user devices to the Local Unit
3. If the Local Unit has audio support (ST-C5USBVA-300) , connect the cable from the local self-powered
stereo speakers to the 3.5mm stereo audio jack on the Local Unit. (See Fig. 4)
6
Page 10
Figure 4- Connect stereo speakers to XTENDEX Local Unit with audio support
ST-C5USBVA-300 (Local Unit)
+
-
NTI
Network Technologies Inc
USB
XTENDEX
3.5mm Stereo
(Front View)
Audio Jack
R
Self-Powered
Stereo Speakers
Connect the CAT5 Cable
Connect the CAT5 cable to the “CAT5” port on the rear of the Local Unit (see Fig. 5). (If an RJ45 wall outlet is being used, connect the other end of the extension cable to it.) When properly inserted the cable end should snap into place.
CAT5 Cable to Remote
Figure 5- Connect the CAT5 cable to the Local Unit
ST-C5USBV-300 (Local Unit)
+
(Front View)
-
NTI
Network Technologies Inc
XTENDEX USB
R
The Remote Unit
Connect the Remote Devices
Position the Remote Unit such that the CAT5 cable, the monitor cable, the keyboard and mouse, and the AC adapter power connector can each reach the Remote Unit comfortably.
1. Connect the monitor cable to the 15HD female VIDEO port on the back of the Remote Unit. (See Fig. 6)
2. Connect the devices to the Remote Unit.
a. Connect the USB keyboard cable (or wireless adapter) to one of the USB Type A female ports labeled "USB DEVICES" on the back of the Remote Unit. (Either one will work.)
b. Connect the USB mouse cable (or wireless adapter) to the remaining USB Type A female port on the back of the Remote Unit.
7
Page 11
Yellow Communication LED
Green Power LED
ST-C5USBV-300 Remote Unit
(Front View)
+
-
R
NTI
Network Technologies Inc
XTENDEX USB
(Rear View)
USB
R
XTENDE X
Network Technologies Inc
NTI
CAT5 Cable to Local Unit
15HD Female Video Connector
15HD male Video Connector
VGA
Multi-Scan
Monitor
USB Type A male
USB Type A
male connectors
USB Keyboard
Figure 6- Connect the Monitor and Devices to the Remote Unit
USB Type A Female
-
+
USB
Mouse
4. If the Remote Unit has audio support (ST-C5USBVA-300) , connect the cable from the remote self-powered
stereo speakers to the 3.5mm stereo audio jack on the Remote Unit. (See Fig. 7)
Figure 7- Connect remote self-powered speakers to Remote Unit
3.5mm Stereo Audio Jack
ST-C5USBVA-300 Remote Unit
+
-
R
NTI
Network Technologies Inc
USB
XTENDEX
(Front View)
Stereo
Speakers
8
Page 12
Y
Connect the CAT5 cable
Connect the CAT5 cable to the “CAT5” port on the rear of the Remote Unit (see Fig. 8). (If an RJ45 wall outlet is being used, connect the other end of the extension cable to it.) When properly inserted the cable end should snap into place.
WARNING: Never connect the ST-C5USBV-300
Extender to an Ethernet card, Ethernet router,
!
hub or switch or other Ethernet RJ45 connector of an Ethernet device. Damage to devices connected to the Ethernet may result.
ellow CommunicationLED
ST-C5USBV-300 Remote Unit
(Front View)
Green Power LED
-
+
NTI
Network Technologies Inc
XTENDEX
R
USB
CAT5 Cable to Local Unit
Figure 8- Connect CAT5 cable to the Remote Unit
Rackmount Modules (optional)
If ST-C5USBV-300M or ST-C5USBVA-300M XTENDEX rackmount modules (Local and/or Remote modules) are being installed, then an ST-C5RCK-12 Rackmount Extender Module Tray must be used (sold separately) to mount the modules to a RACK. The ST-C5RCK-12 provides a convenient mounting method for up to 12 Local and /or Remote XTENDEX modules.
Note: Rackmount Local modules are compatible with rackmount Remote modules or desktop Remote units.
Mount the ST-C5RCK-12 Rackmount Extender Module Tray
1. The ST-C5RCK-12 Rackmount Extender Module Tray was designed to be directly mounted to a rack. It includes a mounting flange to make attachment easy.
2. Install 4 cage nuts (supplied) to the rack in locations that line up with the holes in the mounting flange on the tray. Then secure the tray to the rack using four #10-32 screws (supplied). Be sure to tighten all mounting screws securely.
10-32
Rack Screws
(supplied)
Figure 9- Mount ST-C5RCK-12 Extender Module Tray to a rack
Rack
Cage Nuts
(supplied)
9
Page 13
3. Slide each module into the tray and line up the holes in the mounting plate on the module with corresponding holes in the tray. Secure the module(s) using the two screws provided. Blank plates and screws are provided to cover empty module spaces.
Frontview of ST-C5RCK-12 with XTENDEX Extender Modules
Figure 10- Secure each module to the tray
4. Secure the power supply for each module to the power supply/cable management shelf at the rear of the tray using the bracket and screw supplied.
NTI
XTENDEX
ST-C5USBVA-300M
LOCAL UNIT
CAT5
R
R
USB
NTI
R
XTENDEX
ST-C5USBVA-300M
LOCAL UNIT
CAT5
R
USB
R
NTI
R
XTENDEX
USB
ST-C5USBVA-300M
LOCAL UNIT
CAT5
Secure XTENDEX module(s) to the ST-C5RCK-12 using the screws provided.
Rearview of ST-C5RCK-12 with XTENDEX Extender Modules
USER
NTI
1275 Danner Dr
Aurora, OH 44202 Tel:330-562-7070 Fax:330-562-1999
www.networktechinc.com
ST-C5USB VA-30 0M
CPU
L
0 C A L
U N
I
9V
R
1.5 A
T
Power supply/cable managment shelf
Power supply mounting bracket (supplied with each module)
Secure each power supply to the tray using the bracket and screw provided.
Figure 11- Secure each power supply to the tray
Plug power connector into Extender module
Connect power cord to power supply here
10
Page 14
Connect the CPU
Connect a UMTINT-xx-MM (or UMTINTA-xx-MM if module has audio support) to the CPU, and then to the Local Unit at the connector marked “CPU”. Make sure all connections are firmly seated. (xx= 3, 6, 10, or 15 foot length)
AUDIO CONNECTOR
ONE WILL BE MARK ED "line
out" ,"speaker", "headphones"
OR WITH THIS SYMBOL
line out
USB CPU
Figure 12- Connect cable between CPU and module
USB Type A male
UMTINTA-3/6/10/15-MM
3.5MM-Stereo Jack
3.5mm Stereo Plug
0.05 SCSI II series
15HD male Video Connector
REAR VIEW
ST-C5USBVA-300M
(Local Unit)
Connect to ST-C5USBVA-300M Local Unit at "CPU"
USER
NTI
1275 Dann er Dr Aurora , OH 44202
Tel:33 0-562-70 70 Fax:330-562-1999
www.ne tworktechinc.c om
ST-C5USBVA-300M
R
1.5 A
CPU
9V
L 0 C A L
U N
I
T
Connect the Devices
Connect a UMTINT-xx (or UMTINTA-xx if module has audio support) to the monitor, keyboard, mouse, and speakers (if supported), and then to the Local or Remote Unit at the connector marked “USER”. Make sure all connections are firmly seated. (xx= 3, 6, or 10 foot length)
0.05 SCSI II series
Connect to ST-C5USBVA-300M Local Unit or Remote Unit at "USER"
1275 Dan ner Dr Aurora , OH 44202
Tel:330-562-7070 Fax:330-562-1999
www.networktechinc.com
Figure 13- Connect cable between user and module
USER
9V
R
NTI
ST-C5USBVA -300M
1.5 A
UMTINTA-3/6/10
R E M O T E
U N
I
T
REAR VIEW
ST-C5USBVA-300M
(Remote Unit)
15HD-Female
Video Connector
USB-A-Female
USB-A-Female
3.5MM-Stereo Jack
VGA
Multi-Scan
Monitor
USB Keyboard
USB
Mouse
Stereo
Speakers
11
Page 15
Connect the CAT5 cable
Connect the CAT5 cable to the “CAT5” port on the front of the Local Unit (see Fig. 8). When properly inserted the cable end should snap into place. Connect the other end of the cable to the “CAT5” port on the Remote Unit.
WARNING: Never connect the ST-C5USBV-300M Extender to an Ethernet card, Ethernet router hub or switch
or other Ethernet RJ45 connector of an Ethernet device. Damage to devices connected to the Ethernet may
!
result.
NTI
XTENDEX
ST-C5USBVA-300M
LOCAL UNIT
R
R
USB
Yellow CommunicationLED
ST-C5USBVA-R-300 Remote Unit
(Front View)
-
+
XTENDEX
Green Power LED
NTI
Network Technologies Inc
USB
R
ST-C5USBVA-R-300M Remote Unit
(Front View)
CAT5
CAT5 Cable- up to 300 feet Connect Local unit to either rackmount Remote Unit module
Figure 14- Connect the CAT5 cable between the Local and Remote Units
(ST-C5USBVA-R-300M) or desktop Remote Unit (ST-C5USBVA-R-300)
-OR-
R
NTI
XTENDEX
ST-C5USBVA-300M
REMOTE UNIT
MAC
CAT5
R
USB
12
Page 16
Plug-in and Boot Up
1. Plug the power cord(s) from the monitor(s) into power outlet(s).
2. Connect the AC adapter power connectors to the 9VDC ports on the Remote and Local Units. (AC adapter shown in Fig. 9)
3. Plug the AC adapters into power outlets. The “Power” LED (Green) on the CAT5 connector of each unit should illuminate, indicating that a proper power connection has been made.
4. Turn ON the CPU and monitor(s). The CPU and monitor(s) should each react as if they were directly connected to each other. The yellow communication LEDs on the Remote and Local Units (see Fig. 8) should blink indicating there is proper communication between them.
Note: A loss of signal (blank screen) may be experienced for an instant during the auto­compensation process after powering-up (ST­C5USBVA model only). This may also occur if the XTENDEX senses a loss of or weak signal connection in the CAT5 cable.
USER
CPU
9V
R
1.5 A
NTI
1275 Danner Dr Aurora, OH 44202 Tel:330-562-7070 Fax:330-562-1999
www.networktechinc.com
ST-C5USBVA- 300M
L 0 C A L
U N I T
ST-C5USBVA-300M (Local Unit-Rearview)
Figure 15- Connect AC adapters
XTENDEX
USB
Network Technologies Inc
NTI
R
(Rear View)
ST-C5USBV-300 Remote Unit
-
+
Barrel
Power Connector
9VDC @ 1.0A OUTPUT
(Outside barrel)
2.1 mm x 5.5 mm Female
(Inside barrel)
9 VDC
Adapter
ADAPTE R
13
Page 17
COMMAND MODE
The XTENDEX has two areas of user control that can be used as needed. The user can adjust video quality (described below) , or enable/disable MAC mode (see page 11) These controls are accessed by entering Command Mode.
To enter Command Mode, simultaneously press the left and right <Shift> keys on the keyboard connected to the Remote Unit. The keyboard LEDs will illuminate.
To exit Command Mode, press <Esc>.
Automatic Video Quality Adjustment (ST-C5USBVA-300 only)
Video quality adjustment is done automatically to assure the image is as clear as possible.
Note: If a different type of cable is used (i.e. shielded cable) and the image is not crisp and clear, there may be a need for fine adjustment.. For fine adjustment, follow the same procedure as described under “Manual Video Quality Adjustment” below.
Manual Video Quality Adjustment (ST-C5USBV-300 only)
It is possible that on initial startup the image on the monitor will not be as crisp as the image normally is. This is due to the
frequency characteristics of the CAT5 cable. It may be necessary to enter Command Mode (described above) and press the ▲ (up arrow) or ▼(down arrow) keys on the remote keyboard until the image is crisp and clear.
Press ▲ (up arrow) key if the image is not crisp and clear enough.
Press the ▼(down arrow) key if the image has been over-corrected (such that horizontal lines appear to trail or
shadow at the edge of an open window).
A momentary press of either key will make a minor change in the image.
Ultimately, the image quality should improve to a satisfactory level. Once the adjustment is made, it should not be necessary to change it again, as the new settings are stored in memory and become the default settings with each startup. To exit Command Mode, press <Esc>.
Note: For additional quality adjustment, it may be necessary to adjust the brightness and contrast settings of the monitor.
Note: The video quality adjustment procedure can only be performed from the keyboard connected to the Remote Unit.
14
Page 18
MAC Mode
MAC Mode enables the user to connect the Local Unit to a MAC CPU. MAC Mode configures the Local Unit for passing mouse information to the MAC CPU. This is useful when the user wants to use mouse drivers provided by the mouse vendor, which allows the use of programmable functions for each mouse button. The Local Unit can be configured whenever necessary.
NOTE: When the port is connected to a PC or SUN CPU, MAC Mode should be OFF (the default setting).
To do this;
1. Enter Command Mode. (Simultaneously press the left and right <Shift> keys on the keyboard connected to the Remote
Unit. The keyboard LEDs will illuminate. )
2. If a MAC CPU is connected, press the <M> key. The keyboard LEDs will momentarily flash and the “MAC” LED on the
Remote Unit will illuminate to indicate MAC Mode is ON. (See Fig. 10)
3. To reconnect the XTENDEX to a SUN or Windows CPU (the default setting) , press the <W> key and the “MAC” LED will
go OFF.
Figure 16- MAC LED
After setting, the configuration is stored in memory and will be retrieved whenever the XTENDEX is powered ON.
Note: MAC Mode can only be enabled from the keyboard connected to the Remote Unit.
ST-C5USBV-300 Remote Unit
(Rear View)
XTENDE X
USB
Network Technologies Inc
NTI
R
MAC port configuration LED
-
+
DDC SUPPORT
DDC information allows the CPU to automatically detect the video capability of your monitor. The DDC information is updated automatically at initial power-ON of the ST-C5USBV-300 Extender or whenever a different monitor is connected to the Extender. DDC is only supported for the monitor connected to the Local Extender and it is recommended that the monitor connected to the remote be the same model. The Local Extender and the monitor must both be powered ON prior to the CPU in order to update the DDC information.
15
Page 19
COMMON APPLICATIONS
Figure 11 (below) illustrates three common applications for the ST-C5USBV-300 USB KVM Extender.
VGA
Multi-Scan
Monitor
USB Mouse
USB Keyboard
Local User Local User
ST-C5USBV-300
USB Mouse
STANDARD APPLICATION BETWEEN USERS AND CPU
Figure 17- Examples of common applications for the ST-C5USBV-300 USB KVM Extender
Existing Local Unit Cable
ST-C5USBV-300 LOCAL UNIT
CAT5 Cable
REMOTE UNIT
VGA
Multi-Scan
Monitor
USB Keyboard
USB Mouse
VGA
Multi-Scan
Monitor
USB Keyboard
Existing Local Unit Cable
ST-C5USBV-300 LOCAL UNIT
CAT5 Cable
ST-C5USBV-300
REMOTE UNIT
USBVEXT-xx-MM
NTI USB
KVM MATRIX
SWITCH
(UNIMUX-nX m-U)
VGA
Multi-Scan
Monitor
USB Mouse
USB Keyboard
BETWEEN CPU AND MULTI-USER MATRIX SWITCH
USB Mouse
USBVEXT-xx-MM
Existing Local Unit Cable
VGA
Multi-Scan
Monitor
USB Keyboard
Local User
ST-C5USBV-300 LOCAL UNIT
CAT5 Cable
ST-C5USBV-300
REMOTE UNIT
BETWEEN SINGLE­USER KVM SWITCH AND USERS
NTI USB
KVM
SWITCH
(UNIMUX-xU )
USB KeyboardUSB Mouse
VGA
Multi-Scan
Monitor
16
Page 20
TECHNICAL SPECIFICATIONS
Maximum Resolution w/ CAT5/5e/6 UTP (refresh frequency 60Hz)
Maximum Resolution w/ CAT5/5e STP (refresh frequency 60Hz)
Video Compatibility WUXGA,UXGA,SXGA, XGA, SVGA, VGA Video Quality Variable for up to 300 feet of CAT5 cable Video Coupling DC Video Connectors HD15 male to CPU
Sync Types Supported Separate and composite TTL Level Video Signal Type Analog RGBHV,RGBS Maximum Input/Output Levels 1.45Vp-p (no offset) Input / Output Impedance 75 Ohms Input Horizontal Frequency Range 15kHz to 130 kHz Input Vertical Frequency Range 30 Hz to 150 Hz Keyboard/Mouse Connectors USB Type A female- to local and remote keyboard/mouse
Interconnect Cable CAT5/5e Solid UTP/STP EIA/TIA 568B wiring w/ male RJ45 connectors
Remote and Local Unit Power 120V or 240V (50 or 60Hz) 9VDC/1.0A AC Adapters Operating Temperature Range ESD protection Complies with EN61000-4-2 Specification CE Mark Complies with EN55022 RoHS Compliant Dimensions WxDxH (In.) (Local or Remote) 3.5x3.1x1.2 (Desktop models) Dimensions WxDxH (In.) (Local or Remote) 1.4x6.8x3.5 (Rackmount modules)
AUDIO
Signal Type Line Level, stereo, unbalanced Connectors Local Unit: 3.5mm Stereo Plug, Pigtail,
Maximum Input Level 2.82 Vp-p (unbalanced) Input Impedance 10 kohms Maximum Output Level 3.1 Vp-p Frequency Response 20 Hz to 20 kHz, + 1dB THD+N <0.017% S/N >76dB Stereo Channel Separation >70dB @ 1 kHz
1024 x 768 @ 60Hz- up to 300 feet 1600 x 1200 @ 60Hz- up to 150 feet 1920 x 1440 @ 60 Hz- up to 100 feet
1024 x 768 @ 60Hz- up to 300 feet 1280 x 1024 @ 60Hz- up to 150 feet 1600 x 1200 @ 60Hz- up to 100 feet
HD15 female to local and remote monitors
USB Type A male- to CPU
- OR­CAT6 Solid UTP EIA/TIA 568B wiring w/ male RJ45 connectors
+10°C to +40°C
3.5mm Stereo Jack, PCB Remote Unit: 3.5mm Stereo Jack, PCB
17
Page 21
INTERCONNECTION CABLE WIRING METHOD
The connection cable between the remote and local is terminated with RJ45 connectors and must be wired according to the EIA/TIA 568B industry standard. Wiring is as per the table and drawing below.
1 White/Orange 2 T 2 Orange 2 R 3 White/Green 3 T 4 Blue 1 R 5 White/Blue 1 T 6 Green 3 R 7 White/Brown 4 T 8 Brown 4 R
Figure 18- Pin positions in female RJ45 connector
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground, outdoors or between buildings.
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
!
Pin Wire Color Pair Function
Pair 2 Pair 1
T
1 +
(View looking into RJ45 female)
Pair 3
Pair 4
T
R
R
T
3
2
4
-
5
+
-
+
R
R
T
8
6
7
-
+
-
18
Page 22
KEYBOARD TRANSLATION
Key Equivalents
Using the chart below, find the character needed to be typed on the CPU being accessed, then follow the row across for the equivalent on the keyboard being used. (See Fig. 13 on page 16 for reference.)
USB 101 WINxx MAC
(Apple USB)
L-Ctrl L-Ctrl L-Ctrl L-Ctrl
L-Alt L-Alt L-Option L-Alt
SB+F12 Application SB+F12 Compose
R-Alt R-Alt R-Option Alt-Graph
SB+Alt Windows Logo Command Meta
SB+R Arrow SB+R Arrow Power Suspend
SB = Space Bar
L and R = Left and Right keys when two keys are marked the same on a keyboard.
SUN
SUN’s 16 Extra Keys
Use the chart below to type SUN's additional 16 keys using a 101, WINxx, or MAC (Apple) USB keyboard).
101,WINxx,MAC Keyboards
SB+F1 Stop (L1) SB+F9 Find (L9)
SB+F2 Again (L2) SB+F10 Cut (L10)
SB+F3 Props (L3) SB+F11 Help
SB+F4 Undo (L4) SB+F12 Compose
SB+F5 Front (L5) SB + Up Arrow Vol +
SB+F6 Copy (L6) SB + Down Arrow Vol -
SB+F7 Open (L7) SB + L Arrow Mute
SB+F8 Paste (L8) SB + R Arrow Suspend
SB = Spacebar
SUN Extras 101,WINxx,MAC
Keyboards
SUN Extras
19
Page 23
Esc
~
`
Tab
Caps Lock
Shift
Ctrl Alt
Backspace
Enter
Shift
Alt
Ctrl
Num Lock
Enter
Esc
F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12
~
`
Tab
Caps Lock
Shift
Ctrl Alt
Windows Logo Key
Typical 101 Keyboard
Backspace
Enter
Shift
Alt
Ctrl
Application KeyWindows Logo K ey
Windows USB Keyboard
Print Screen SysRq
Scroll Lock
Pause Break
Num Lock
Enter
F12 F11
esc
~ `
tab
caps Lock
shift
control
alt
option
Command Key
Apple Pro USB Keyboard
F10 F8 F7 F6 F5 F4 F3 F2 F1
F9
Command Key
delete
return
shift
alt
controloption
F13 F14 F15
num lock
clear
=/
*
enter
Help
Stop
Props
Front
Open
Find Cut
Again
Undo
Copy
Paste
Esc
Tab
Control
Shift
Capslock Alt
Return
Shift
Com­pose
Meta Key Meta Key
SUN USB Keyboard
Backspace
Alt Graph
Num Lock
CD Eject Key
Power key
Enter
Figure 19- Keyboard Layouts
20
Page 24
TROUBLESHOOTING
Each and every piece of every product produced by Network Technologies Inc is 100% tested to exacting specifications. We make every effort to insure trouble-free installation and operation of our products. If problems are experienced while installing this product, please look over the troubleshooting chart below to see if perhaps we can answer any questions that arise. If the answer is not found in the chart, please check the FAQs (Frequently Asked Questions) at our website at http://www.networktechinc.com or contact us directly for help at 1-800-742-8324 (800-RGB-TECH) in US & Canada or 1-330-562-
7070. We will be happy to assist in any way we can.
Problem Cause Solution
Remote Unit power LED does not illuminate
Local Unit power LED does not illuminate
No video on monitor
Video picture is not sharp or is smeared
Monitor sometimes loses sync, causing it to go blank for a second or two
The picture on the monitor is black and white, rather than color A constant vertical wobble appears down the screen PC boots with no error messages, but the keyboard does not work Wrong or missing characters from those typed Connecting the keyboard effects the video Mouse cursor appears on the screen, but the mouse does not work
Cannot enter Command Mode
Mouse is not working as configured when connected to a MAC
Power supply is not connected or plugged-in.
Power supply is not connected or plugged-in.
One or more video cables is loose or disconnected.
No Power to Remote or Local Units.
Video Cable was not attached when
CPU was booted.
CAT5 cable is not connected.
All Video Cables are not firmly
seated.
CAT5 cable is too long.
The CAT5 cable is not properly
connected.
Video quality is not set properly.
Electrical power system is very noisy,
particularly the ground.
The CAT5 cable is not properly connected.
The video cable was not attached to the CPU when it was booted.
CAT5 cable is too close to a strong power source.
Keyboard cable is loose.
Keyboard in use is not compatible.
The keyboard may be in the wrong mode.
Older keyboards may require higher current than our unit supplies.
Mouse cable is loose or disconnected.
Mouse is not compatible.
Remote connections didn’t
initialize. User is trying to access Command Mode from the devices connected to the Local Unit
ST-C5USBV-300 is not operating in MAC mode
Make sure outlet is live and transformer is plugged-in.
Make sure 9VDC jack is fully connected to the Remote
Unit.
Make sure outlet is live and transformer is plugged-in.
Make sure 9VDC jack is fully connected to the Local Unit.
Check all video cable connections
Make sure power LED is illuminated for local and remote.
If not, see both solutions above.
With all the cables properly connected, reboot the CPU.
Check cable connections. Make sure they are snapped-in
properly and completely.
Check cable connections. Make sure they are snapped-in properly and completely.
Check all connections. Make sure all cables are fully seated.
Verify length is within specified limits-300'.
Check cable connections. Make sure they are snapped-in
properly and completely.
See pg. 10 for instruction on "Video Quality Adjustment".
Make sure the interconnection cable is not near any power
lines.
Check cable connections. Make sure they are snapped-in properly and completely.
With the cables all properly connected, reboot the CPU.
Reroute CAT5 cable if possible.
Reseat Keyboard cable and check again.
Make sure Keyboard is directly connected, not
through a PS/2 to USB adapter.
Disconnect keyboard at Remote Unit end and reconnect.
Reboot the system.
Change to a newer keyboard.
Check for quality cable connections to mouse at Remote Unit end.
Make sure mouse is USB type.
Power down the Remote Unit and then power up again.
Command Mode is not accessible at the Local Unit. Try again from devices connected to the Remote Unit. (See page 10.)
Check to see if MAC mode LED is illuminated. If not, enable MAC mode (see page 15)
21
Page 25
INDEX
CAT5 Cable Spec, 18 CAT5 LEDs, 9
Command Mode, 14 DDC support, 15
Devices Supported, 1
Installation, 5
Key Equivalents, 19 limitations, 2 MAC LED, 3
MAC Mode, 15
mount to a rack, 9 Rackmount modules, 9 Specifications, 17 ST-C5RCK-12, 9 SUN extra keys, 19 Troubleshooting, 21 Video quality adjustment, 14
WARRANTY INFORMATION
The warranty period on this product (parts and labor) is two (2) years from the date of purchase. Please contact Network
Technologies Inc at (800) 742-8324 (800-RGB-TECH) or (330) 562-7070 or visit our website at
for information regarding repairs and/or returns. A return authorization number is required for all repairs/returns.
Note: CAT5 connection cable used between NTI XTENDEX Series Local and Remote or any XTENDEX Series products should not be run underground, outdoors or between buildings.
!
WARNING: Outdoor or underground runs of CAT5 cable could be dangerous and will void the warranty.
http://www.networktechinc.com
Man010 Rev 5/5/08
22