Network Technologies SM-nXm-15V-LC Installation Manual

Page 1
NTI
NETWORK
R
TECHNOLOGIES INCORPORATED
1275 Danner Dr Aurora, OH 44202
www.networktechinc.com
Tel:330-562-7070 Fax:330-562-1999
VEEMUX®Series
SM-nXm-15V-LC
Video Matrix Switch
Installation and Operation Manual
MAN156 Rev Date 8/1/2012
Page 2
TRADEMARK
VEEMUX is a registered trademark of Network Technologies Inc in the U.S. and other countries.
COPYRIGHT
Copyright © 1999, 2012 by Network Technologies Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202.
CHANGES
The material in this guide is for information only and is subject to change without notice. Network Technologies Inc reserves the right to make changes in the product design without reservation and without notification to its users.
FIRMWARE VERSIONS
Firmware Version 1.0
i
Page 3
Introduction....................................................................................................................................................................1
Basic Operation ...........................................................................................................................................................1
Supported Web Browsers............................................................................................................................................1
Ordering Information....................................................................................................................................................1
SM-nXm-15V-LC.......................................................................................................................................................1
Materials ......................................................................................................................................................................2
Cables..........................................................................................................................................................................2
Default User Name and Passwords ............................................................................................................................2
Features and Functions................................................................................................................................................3
Installation......................................................................................................................................................................4
To Mount to a Rack .....................................................................................................................................................4
Connect the Sources and Monitors.............................................................................................................................5
Connect RS232 ...........................................................................................................................................................6
Connect to the Ethernet...............................................................................................................................................6
Power Up.....................................................................................................................................................................7
Control Options.............................................................................................................................................................8
Front Panel LCD with Keypad Control.........................................................................................................................8
LCD Menus............................................................................................................................................................9
Save and Load (Recall) Config..............................................................................................................................9
RS232 Control...........................................................................................................................................................10
Remote Connection...................................................................................................................................................10
Baud Rate............................................................................................................................................................10
Unit Address and Loop Back...............................................................................................................................10
Command Protocol.................................................................................................................................................12
Autostatus............................................................................................................................................................13
NTI Switch Control Program For Windows 9X, NT, 2000, XP, Vista and 7 ..............................................................13
SerTest- RS232 Interface Test Program...................................................................................................................14
Main Options...........................................................................................................................................................14
Matrix Operations....................................................................................................................................................14
Ethernet Operations................................................................................................................................................14
Setup Options.........................................................................................................................................................15
Ethernet Control..........................................................................................................................................................16
Telnet Interface-Port 2000.........................................................................................................................................16
Telnet Interface-Port 2005.........................................................................................................................................17
Command Summary...............................................................................................................................................17
Command Detail.....................................................................................................................................................18
RU-Read Unit Size..............................................................................................................................................18
RO-Read Connection for Output Port .................................................................................................................18
CS- Connect Output Port to Input Port................................................................................................................18
CA- Connect All Output Ports to Input Port.........................................................................................................18
SS_01- Enable Auto Status Mode.......................................................................................................................19
SS_00- Disable Auto Status Mode......................................................................................................................19
SX- Examine connections ...................................................................................................................................19
Terminate telnet session .....................................................................................................................................20
Web Interface ............................................................................................................................................................21
Enter the Password ................................................................................................................................................21
Video Switch Page..................................................................................................................................................22
Administration.........................................................................................................................................................24
System Configuration..........................................................................................................................................24
Network Configuration.........................................................................................................................................25
Video Input Names..............................................................................................................................................26
Video Output Names...........................................................................................................................................27
Scanning Sequences...........................................................................................................................................28
Change Password...............................................................................................................................................30
Update Firmware.................................................................................................................................................31
Standby Mode .....................................................................................................................................................32
Logout..................................................................................................................................................................32
ii
TABLE OF CONTENTS
Page 4
Support................................................................................................................................................................33
Reboot.................................................................................................................................................................33
Device Discovery Tool................................................................................................................................................34
Infrared Remote Control.............................................................................................................................................35
Materials ....................................................................................................................................................................35
Buttons.......................................................................................................................................................................36
Operation...................................................................................................................................................................37
Changing Ports.......................................................................................................................................................37
Channel Surfing...................................................................................................................................................37
Jump To Input......................................................................................................................................................38
Jump To Output...................................................................................................................................................38
Connect All ..........................................................................................................................................................38
Save and Recall......................................................................................................................................................38
Multiple Switch Control...........................................................................................................................................39
Canceling a Command...........................................................................................................................................39
Technical Specifications For IRT-UNV......................................................................................................................39
Troubleshooting the IRT-UNV ...................................................................................................................................39
RS232 Connection Cable............................................................................................................................................40
Pinout for Matrix Y-1 Cable........................................................................................................................................40
Specifications..............................................................................................................................................................40
Troubleshooting..........................................................................................................................................................41
Safety Statements .......................................................................................................................................................41
Index.............................................................................................................................................................................41
Warranty Information..................................................................................................................................................42
TABLE OF FIGURES
Figure 1- Secure rack mount ears to switch.......................................................................................................................................4
Figure 2- Secure switch to a rack ......................................................................................................................................................4
Figure 3- Install Video Source Cables................................................................................................................................................5
Figure 4- Connect a monitor to the VEEMUX....................................................................................................................................5
Figure 5- Connect user terminal for RS232 control............................................................................................................................6
Figure 6- Connect the LAN to the VEEMUX......................................................................................................................................6
Figure 7- Connect Power to VEEMUX...............................................................................................................................................7
Figure 8- RS232 connection with Matrix-Y-1 cable..........................................................................................................................11
Figure 9- Pinout of Matrix-Y-1 cable................................................................................................................................................11
Figure 10- Web interface Login page..............................................................................................................................................21
Figure 11- Main menu and Video Switch page................................................................................................................................22
Figure 12- System Configuration page ............................................................................................................................................24
Figure 13- Network Configuration page...........................................................................................................................................25
Figure 14- Video Input Names page................................................................................................................................................26
Figure 15- Video Output Names page.............................................................................................................................................27
Figure 16- Scanning Sequence page ..............................................................................................................................................28
Figure 17- Change Password page .................................................................................................................................................30
Figure 18- Update Firmware page...................................................................................................................................................31
Figure 19- VEEMUX in Standby Mode.............................................................................................................................................32
Figure 20- Logout of the VEEMUX web interface............................................................................................................................32
Figure 21- Support Tab....................................................................................................................................................................33
Figure 22- System Reboot...............................................................................................................................................................33
Figure 23- Device Discovery Tool page...........................................................................................................................................34
iii
Page 5
NTI VEEMUX VIDEO MATRIX SWITCH
INTRODUCTION
The SM-nXm-15V-LC (n = number of inputs (video sources), m = number of outputs (monitors)) video matrix switch (VEEMUX) allows any of up to 8 video sources to output to any or all of up 8 (8) monitors. The configuration of the VEEMUX is determined at time of order. The bandwidth of the SM-nXm-15V-LC is 160MHz and video resolutions through 1920 x1200 are supported with no degradation. The switch can be controlled with the Front Panel Keypad, RS232 interface, Ethernet, or an Infrared Remote.
The VEEMUX can be ordered in many sizes and with several control options. The base unit includes a user keypad, an RS232 port, and an Ethernet port to make up a complete system. Built-in infrared control allows for maximum user satisfaction in each unique configuration.
Basic Operation
The VEEMUX allows any source to be connected to any destination at any time with no restrictions or limitations.
Video inputs accept any RGBHV, RGBS, or RGsB signal.
Video outputs are compatible with any RGBHV or RGBS monitor, regardless of input. (RGsB monitor requires
RGsB input)
Supported Web Browsers
Most modern web browsers should be supported. The following browsers have been tested:
Microsoft Internet Explorer 6.0 or higher
Netscape 7.0 or higher
Mozilla FireFox 0.9.2 or higher
Set your browser to always check if there is a newer version of the page than the version stored in cache. This action will ensure that it will display the most up-to-date information.
Ordering Information
The SM-nXm-15V-LC is built to a specific size ranging from 2, 4 or 8 monitors and 4 to 8 video sources. The “n” in the part number represents the number of video sources. Select a switch built for 4 or 8 video sources. The “m” in the part number represents the number of outputs (monitors). A switch built for 2, 4 or 8 monitors may be ordered. It is not necessary to fully populate all of the connectors on the unit (ex. an SM-8x8 switch has the capability of supporting 8 video sources and 8 monitors, but it will operate with only 4 video sources with 2 monitors connected.
SM-nXm-15V-LC
Replace the “n” with 4 or 8 Replace the “m” with either 2, 4 or 8 The following list represents the available sizes that can be ordered:
SM-4x2-15V-LC SM-8x2-15V-LC SM-4x4-15V-LC SM-8x4-15V-LC SM-8x8-15V-LC
1
Page 6
NTI VEEMUX VIDEO MATRIX SWITCH
Materials
Materials Supplied with this kit:
NTI SM-nXm-15V-LC Video Matrix switch
IEC Line cord, country specific
Infrared Remote Control with 2-AAA batteries
CT6182 DB9 Female-to-RJ45 Female adapter
CB5021- 5 foot CAT5e-SF-5-Gray patch cable
4-#10-32 x 3/4" pan head screws and 10-32 cagenuts (server cabinet mounting hardwar e)
CD with: a pdf file of this owner's manual
the NTI Discovery Tool the NTI Switch Control Program
Cables
All cables are sold separately. The following tables list the available stocked cables with thei r length in feet. All VGA input and output connectors on Matrix Switches are FEMALE. When using multi-coax high resolution VGA to BNC cables, the BNC connectors are also FEMALE for input and output. Custom cables are available – contact NTI for pricing and distance / resolution limitations.
NTI NAME DESCRIPTION
VGA
VEXT-3/6/10/15/25/35/50/75/100-MM
VEXT-3/6/10/15/25/35/50/75/100
VINT-5B-6
Matrix-Y-1 or see page 31 for alternative cables CT6182 RJ45F-DB9M Adapter Contact NTI for various lengths and colors
Contact NTI for various lengths and colors
Multi-coax high resolution VGA or SVGA video cable. Connectors are 15HD male-male (used for INPUTS)- 3 thru 100 feet
Multi-coax high resolution VGA or SVGA video cable. Connectors are 15HD male­female (used for OUTPUTS)-3 thru 100 feet
Multi-coax high resolution VGA to BNC cable. Connectors are 15HD male to 5 BNC’s-6 feet long
RS232
RS232 Interface Cable- Connectors are 9D male- female-female 12" long
Cat5 UTP Cable- Connectors are RJ45 male-Stocked cables are 2 thru 100 feet Custom cables must have RJ45 connectors wired straight thru- pin 1 to pin 1, etc.
ETHERNET
Cat5 UTP Cable- Connectors are RJ45 male-Stocked cables are 2 thru 100 feet Custom cables must have RJ45 connectors wired straight thru- pin 1 to pin 1, etc.
Default User Name and Passwords
The default Telnet password is nti (lower case letters only) . For instruction on using Telnet, see page 16. (No username is required in order to use Telnet. You will only be prompted for a password.)
The default Web Interface user name
The default Web Interface password see page 21.
is root (lower case letters only).
is nti (lower case letters only). For instruction on using the Web Interface,
2
Page 7
NTI VEEMUX VIDEO MATRIX SWITCH
FEATURES AND FUNCTIONS
#
LABEL CONNECTOR/LED DESCRIPTION
Menu Buttons Buttons for navigating LCD menu
1
None LCD Display Displays port connections and menu for control of the VEEMUX
2
PWR Green/Red LED Illuminates green to indicate proper power to the unit and normal
3
operation Illuminates red during system boot-up or while in standby
IR In Sensor Receives communication from hand-held remote control
4
IR Activity Green LED Illuminates to indicate communication between the hand-held remote
5
control and the VEEMUX
AC INPUT IEC Connector For attachment of the IEC power cord to power the VEEMUX
6
Fuse Fuseholder For replaceable 2A 240VAC Fast-blo Fuse
6a
None Power Switch For powering ON and OFF the VEEMUX
7
VIDEO HD15 Female For direct connection of VGA video cable from video source
8
MONITOR HD15 Female For direct connection of VGA video cable from display device
9
ETHERNET RJ45 Female For connection to an Ethernet for remote multi-user control
10
RS232 RJ45 Female For connection of a PC for serial control
11
System Reset Button Press to reset VEEMUX to default settings
12
3
Page 8
NTI VEEMUX VIDEO MATRIX SWITCH
INSTALLATION
To Mount to a Rack
1. Attach the ears to the switch using the #6-32x3/16" flat Phillips-head screws (6) provided as shown in the illustration b elow. The holes in the ears should line up with pre-threaded holes in the sides of the NTI switch. Tighten the screws securely.
Front of Switch
Figure 1- Secure rack mount ears to switch
2. Install 4 cage nuts (supplied) to the rack in locations that line up with the holes in the mounting ear on the NTI switch.
3. Secure the NTI switch to the rack using four #10-32X3/4” screws (supplied). Each screw should be of sufficient length
to go completely through the NTI mounting ear, rack frame and fully engage all threads in the cage nut. Be sure to tighten all mounting screws securely.
4. Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.
#10-32x3/4"
Rack Screws
(supplied)
NTI Switch
6-32x3/16" Flat Head Screws (supplied)
Rack mount ear
NTI Switch
Rack
Cage Nuts
(supplied)
Figure 2- Secure switch to a rack
4
Page 9
NTI VEEMUX VIDEO MATRIX SWITCH
Connect the Sources and Monitors
1. Turn OFF power to all video sources (inputs) that will be connected to the VEEMUX before connecting or
disconnecting any cables.
2. Connect a VEXT-xx-MM cable from the video port of a video source to a 15HD female video connector
labeled VIDEO 1 on the VEEMUX. (See Fig. 1)
3. Connect additional video sources to remaining 15HD female VIDEO x connectors as desired.
Figure 3- Install Video Source Cables
4. Connect a monitor to the 15HD female connector labeled MONITOR 1 on the rear of the VEEMUX (See Fig. 2).
5. Connect additional monitors to remaining 15HD female MONITOR x connectors as desired.
Figure 4- Connect a monitor to the VEEMUX
5
Page 10
NTI VEEMUX VIDEO MATRIX SWITCH
Connect RS232
RS232 control can be achieved using a separate user terminal or CPU with a terminal program. To make a terminal connection, a DB9M-to-RJ45F adapter and 5 foot CAT5 patch cable have been supplied if needed.
Figure 5- Connect user terminal for RS232 control
Connect to the Ethernet
If the Telnet Interface (page 16) or Web Interface (page 21) will be used, an Ethernet connection to the Local Area Network (LAN) must be made using CAT 5 cable with RJ45 connectors. Wiring between the connectors should be straight through (pin 1 to pin 1, pin 2 to pin 2, etc.) Connect a CAT 5 cable between the connector label "ETHERNET" and the LAN (see Fig. 4).
Figure 6- Connect the LAN to the VEEMUX
6
Page 11
NTI VEEMUX VIDEO MATRIX SWITCH
Power Up
1. Plug the VEEMUX into an AC power outlet.
2. Turn ON power to the VEEMUX.
3. Turn ON power to the video sources and monitors connected to the VEEMUX.
Figure 7- Connect Power to VEEMUX
7
Page 12
NTI VEEMUX VIDEO MATRIX SWITCH
CONTROL OPTIONS
The VEEMUX video matrix switch has four methods of control:
Front Panel LCD with Keypad
Directly via an RS232 Interface
Remotely via Ethernet
Infrared Remote.
Every unit comes standard with the Front Panel LCD with Keypad, RS232, and Infrared Receiver built in. With the RS232 option, there are no external devices to be purchased. NTI provides software commands as well as a test program to ensure the RS232 functions properly (see page 10 – RS232 Control).
Front Panel LCD with Keypad Control
The front panel LCD and keypad allow the user to monitor switch status and route any user to any video source on the switch. When the unit is powered up, each monitor is automatically connected to the video source of its equa l number (i.e. monitor 1 to source 1, monitor 2 to source 2, monitor 3 to source 3, etc.). Along with the routing of the inputs (video sources) to the outputs (monitors) the keypad and LCD allow the users to configure the RS-232 control interface. The keypad buttons perform the following functions.
ESC Escape back to the main display. 0 – 9 Used to enter numbers. ( # ) OUT Precedes the output number IN Used following single digit output entries ENTER Used following single digit entries and to select menu options
Display next 4 outputs and their inputs  Display previous 4 outputs and their inputs
MENU See below for description of the Menu. * Connects all outputs to one input (i.e. To set all outputs to one input ( * ) + (Input # ) + (ENTER) )
To configure the VEEMUX, use the Menu keys. Press the List button to list your main menu options:
1- Serial 2- Ethernet 3- Standby 4- Save Config 5- Load Config
Use the Up and Down Arrow keys to scroll through this list. Use the Enter Key to select a menu item. Press the Menu button again to exit the menu.
If, while in a menu, you pause for more than 5 seconds, you will automatically exit the menu.
8
Page 13
NTI VEEMUX VIDEO MATRIX SWITCH
LCD Menus
1. Under the “Serial” menu are two parameters:
1- Baud rate 2- Address
These parameters are used when the VEEMUX is controlled through an RS232 connection (page 1 0). If you select Baud rate, use the arrow keys to toggle through the available baud rates. The baud rate can be set to 115200, 57600, 38400, 19 200, 9600, 4800, 2400, or 1200.
If you select Address, use the arrow keys to toggle through the address options (01-15). This is also the switch address used in conjunction with the IR Remote operation (page 39).
2. Under “Ethernet” menu are several parameters:
1- Mode 2- IP 3- Mask 4- Gateway 5- Primary DNS 6- Alt. DNS
The Mode parameter will let you select between a manual IP setting (“Static”) and a “DHCP” assigned dynamic IP address setting. An asterisk indicates which mode is configured, an arrow shows which mode is being selected. To change the configured setting and move the asterisk, select the desired mode and press the Enter button.
If you choose a manual IP setting, the IP parameter provides the fields for entering a valid IP address. Use the up and down arrows to advance the numbers, and the Enter button to move from field to field. Press Menu to exit this screen.
Selections 3, 4 are necessary to apply valid values for your Subnet Mask and Gateway. Navigate these settings as described for setting the IP address.
Selections 5 and 6 are not used at this time and are therefore unnecessary.
3. The third option in the main menu is ”Standby”. If you select Standby, the VEEMUX switch will immediately go into a power
saver mode and the LCD display will go blank. It will remain in this state until
1) any button is pressed on the front panel,
2) the Standby button is pressed on the IR Remote Control (page 36), or
3) the “Disable Standby” button is pressed in the web interface (page 32)
Save and Load (Recall) Config
The VEEMUX provides the ability to save and recall up to 100 switch configurations using the LCD menu. The switch
configurations define the current port connections and video blank status.
Note: The Remote Control can also be used to access these configurations by using the “SAVE” and “RECALL ” buttons.
To save a configuration, select “Save Config” from the main menu followed by a numeric button(s) (0-99) corresponding to the memory slot the configuration is to be saved in. Press Enter after your selection to force the current configuration to immediately be saved to the selected memory slot.
Configurations can be loaded (recalled) in much the same manner. To recall, select “Load Config” fro m the main menu followed by the numeric button(s) (0-99) corresponding to the memory slot from which the configuration is to be recalled. Press Enter after your selection to immediately force the switch to change the current switch configuration to match that of the configuration recalled.
Configurations that are saved into memory locations via the keypad can be recalled via the web interface (page 22) and vice versa.
9
Page 14
NTI VEEMUX VIDEO MATRIX SWITCH
RS232 Control
RS232 enables the VEEMUX to be remotely controlled via RS232. To control the VEEMUX via RS232 the user has three options:
write a program that runs on a PC using the Command Protocol (page 12)
use the NTI Switch Control Program (page 13) provided on the CD
use the SerTest program (page 14) provided on the CD
Remote Connection
The RS232 Interface is designed to meet the RS232C standard and can be controlled from any CPU or other controller with an RS232 communications port. The pin-out for the RJ45 connector on the unit is as follows:
RS232 (RJ45) CONNECTOR
PIN SIGNAL FUNCTION
1 - No connection 2 - No connection 3 RX+ Receive data (TXD at host) 4 GND Ground 5 - No connection 6 TX+ Transmit data (RXD at host) 7 - No connection 8 - No connection
A 5 foot patch cable and adapter, RJ45-to-DB9, have been provided for connection to most CPUs (see page 6). To daisy chain multiple units, connect a Matrix-Y-1 cable (sold separately) between the CPU and the first switch, and between each switch (as shown in Figure 8).
Baud Rate
The baud rate can be changed by selecting MENU on the front panel ke ypad, using Telnet commands (page 16) or from the RS232 commands (page 12). The baud rate can be set to 115200, 57600, 38400, 19200, 9600, 4800, 24 00, or 1200. A data protocol of 8 data bits, no parity, and 1 stop bit is used for communications. The default baud rate setting is 9600.
Unit Address and Loop Back
To allow multiple units to be controlled from a single host port, the RS232 control interface is designed to allow "daisy chaining" up to 15 units using an NTI Matrix-Y-1 cable. Connect the Matrix-Y-1 cable between the RJ45-to-DB9 serial adapter (provided with the RS232 option) and the CPU as shown in Figure 8. By setting the appropriate unit ad dress (pa ge 9), each unit can be given a unique address (1-15). Then the unit will only respond to commands on the bus if its address is embedded in the command.
10
Page 15
NTI VEEMUX VIDEO MATRIX SWITCH
exceed 15 feet.
CPU
Figure 8- RS232 connection with Matrix-Y-1 cab le
Figure 9- Pinout of Matrix-Y-1 cable
RS232 Serial Port
RJ45 TO DB9 SERIAL ADAPTER
RS232
NTI
SWITCH
First Unit
Matrix-Y-1
RJ45 TO DB9 SERIAL ADAPTER
CAT5 CABLE CAT5 CABLE CAT5 CABLE
RS232
NTI
SWITCH
Second Unit Last Unit
Wiring Schematic of Matrix-Y-1 cable
9D Female9D Male 9D Male
(Unit #1)
23 33
555
(Source)
22 7
Jumper
8
1
Jumpers
4 6
Matrix-Y-1 Matrix-Y-1
RJ45 TO DB9 SERIAL ADAPTER
(Unit #2)
Not connected to source connector
Note: The maximum combined RS232 cable length between the CPU and any NTI switch cannot
RS232
NTI
SWITCH
11
Page 16
NTI VEEMUX VIDEO MATRIX SWITCH
Command Protocol
CPU controller commands supported by the unit are defined below. All commands must be terminated with a <CR> (carriage return). When a command is sent, the entire string is echoed back along with a response from the addressed unit as shown in the Command Definitions table (below). All characters in the command string are case sensitive (see Command Definiti ons table), and all numbers below 10 must have a leading 0 (ex: 1 = 01).
Legend: (All numbers must be two digits) SW : Switch (01-15) (Unit Address) MM : Save Into Memory Bank (00-99)
BR : Baud R ate Co de LL : Load From Memory Bank (00-99) OP : Output Port (01-MAXOUTPUTS) <CR> : Carriage Return (Hex 0xD) IP : Input Port (01-MAXINPUTS) ip
Command Definitions
Command String
CS SW,IP,OP *<CR> Connect One Output Port To Input Port CA SW,IP *<CR> Connect All Output Ports To Input Port RO SW,OP *<CR>IP<CR> Read Connection For Output/User Port CC SW,MM *<CR>MM<CR> Save Matrix Connections Into Memory Bank xx
RC SW,LL *<CR>LL<CR> Restore Matrix Connections From Memory Bank CB 00,BR None Change baud rate of serial line,
RS SW *<CR> Internal Reset RV SW,00 *<CR>string\0<CR> Read NTI Version String RU SW *<CR>IP,OP<CR> Read Unit Size EA SW,ip *<CR> Set the IP address, ip is in xxx.xxx.xxx.xxx format,
EM SW,ip *<CR> Set the Subnet mask, ip is in xxx.xxx.xxx.xxx format,
EG SW,ip *<CR> Set the default gateway, ip is in xxx.xxx.xxx.xxx format,
ET SW,timeout *<CR> Set the website timeout; timeout = numeric string of timeout in seconds.
RA SW * <CR>ip<CR> Read the IP address, ip is in xxx.xxx.xxx.xxx format,
RM SW * <CR>ip<CR> Read the Subnet mask, ip is in xxx.xxx.xxx.xxx format,
RG SW * <CR>ip<CR> Read the default gateway, ip is in xxx.xxx.xxx.xxx format,
RT SW * <CR>timeout<CR> Read the website timeout; timeout = numeric value in seconds.
SS SW,00 *<CR> Disable Autostatus feature (see below) SS SW,01 *<CR> Enable Autostatus feature (see below) GO SW,OP *<CR>go SW,OP:IP<CR> Read connection of a Output Port to Input Port GM SW,00 *<CR>go SW,OP:IP (all
Ss SW,OP,DWT *<CR>
Good Response Description
ports)<CR>
: IP address
Xx=00-99
BR=11(5200),57(600),38(400),19(200)96(00),48(00),24(00),12(00)
Factory default is 9600
number of digits is minimum 1 and maximum 3 for each field Leading zeroes are accepted
number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted
number of digits is minimum 1 and maximum 3 for each field Leading zeroes are accepted
Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout
number of digits is minimum 1 and maximum 3 for each field Leading zeroes are accepted
number of digits is minimum 1 and maximum 3 for each field Leading zeroes are accepted
number of digits is minimum 1 and maximum 3 for each field Leading zeroes are accepted
Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout
Read connection matrix of all Output ports Set Scan Mode dwell time for specific Output port
DWT values: 000-255 000= scan disabled See page 8 for more info.
12
Page 17
NTI VEEMUX VIDEO MATRIX SWITCH
Command Definitions (Continued)
Command
Good Response Description
String
Gs SW,OP *<CR>DWT<CR> Read scan mode dwell time setting for an Output port
DWT values: 000-255 000= scan is disabled for the port Sa SW,OP *<CR> Set scan list of individual output to all inputs Sc SW,OP *<CR> Clear sc an list of individual output S+ SW,OP,IP *<CR> Add individual input to Scan List of output S- SW,OP,IP *<CR> Remove individual input from Scan List of output Sx SW,OP *<CR>oooxoxxxooooxxx<
CR>
Inspect the Scan List of individual output (o=skip x=don't skip)
If the first field is not a known command (as listed above) or SW field is different from the serial address programmed in the switch memory, the command will be ignored. If the SW field corresponds to the unit address, but the syntax is wrong after this field, the switch will answer with a bad response ?<CR>.
Autostatus
When Autostatus is enabled, any output-to-input connection change in the VEEMUX will cause an Autostatus message to be sent via RS232 to the administrator. The format of the message would be "pc SW,OP:IP<CR>"
Example of an Autostatus message: pc 01,01:04<CR> which means "At the switch with unit address 01, the output (01) has changed connection to input 04."
Notes: Message to the administrator will be delayed by any RS232 traffic being received by the switch from the administrator. Autostatus must be disabled before using SerTest or the NTI Switch Control Program (below).
By default, Autostatus is disabled and must be manually enabled. Autostatus is also disabled any time the power to the VEEMUX is interrupted.
NTI Switch Control Program For Windows 9X, NT, 2000, XP, Vista and 7
The NTI Switch Control Program is an easy and powerful graphical program that controls NTI matrix switches through an RS232 interface. The NTI Switch Control Program is included on the CD packaged with the VEEMUX. The NTI Switch Control Program is downloaded by clicking on the link "Download NTI Switch Control Program" found o n the web page that appears
when you insert the instruction manual CD into your CD ROM drive.
To install the NTI Switch Control Program after downloading
1. Locate the Setup.exe in the directory the program was downloaded to and double-click on it
2. Follow the instructions on the screen
The NTI Switch Control Program performs best on monitors set to a screen resolution of at least 800 X 600. Instruction for using the NTI Switch Control Program is available by opening "MSCP Help" in the "NTI" program group once the program has been installed and is open on the screen.
To open "MSCP Help" from the Windows desktop
1. Click on START
2. Click on PROGRAMS
3. Click on NTI
4. Click on MSCP Help
13
Page 18
NTI VEEMUX VIDEO MATRIX SWITCH
SerTest- RS232 Interface Test Program
This software allows a user to test the functions of an NTI server switch, matrix switch or Multi-user/Multi-platform switch RS232 interface. The program SERTEST along with the NTI Switch Control Program (above) is installed from the CD packaged with this switch. SERTEST generates a main menu with the 3 selections described below:
Main Options
Matrix Operations
Ethernet Operations
Setup Options
About SerTest
Matrix Operations
Key Selection Description
1) Connect Video Output/User to an Input/CPU - connect an output to an input
2) Connect All Video Outputs/Users to an Input/CPU - connect all outputs to an input
3) Connect Audio Output/User to an Input/CPU - connect an output to an input (audio ports only)
4) Connect All Audio Outputs/Users to an Input - connect all outputs to an input (audio ports only)
5) Change Mute Status for Audio Output/User (not
applicable to this unit)
6) Change Volume for Audio Output/User (not
applicable to this unit)
7) Read Connection for Video Output/User -read the connection of a specific video output
8) Read Connection for Audio Output/User -read the connection of a specific audio output
9) Read Mute and Volume for Audio Output/User - read the volume and the mute status of the specified audio output a) Save I/O Connections into Unit Memory -save the connections into switch memory bank b) Restore I/O Connections from Unit Memory -restore the connections from switch memory bank c) Change Al l Units Baud Rate (9600/COM1:) -change RS-232 Baud rate of all switches
d) Reset Unit - send a reset command to the switch e) Reset All Units - send an internal reset command to all switches
f) Read Unit Size - read the switch size (number of inputs and outputs) g) Read Unit Version/Revision String -read a string containing the switch version, type, and size h) Save All Units I/O Connections into Units Memory -save the connections into switch memory bank, command for all
i) Restore All Units I/O Connections from Units
Memory
Selections in the "Key" column that are gray are not applicable to this product.
- send commands to the matrix unit.
- set Ethernet connection variables
- set COM port, baud rate, and unit address
- display the program version
- mute or un-mute the Audio port output
- change Audio port output volume
-the current baud rate and serial port are displayed in parentheses
- the current unit address is displayed in parentheses
switches
-restore the connections from switch memory bank, command for all switches
Ethernet Operations
Key Selection Description
1) Set Unit IP Address - enter the desired IP address in xxx.xxx.xxx.xxx format
2) Set Unit Subnet Mask
3) Set Unit Default Gateway - enter the desired default gateway
4) Set Unit Website Timeout - set the website timeout; timeout = numeric string of timeout in seconds
5) Read Unit IP Address - read the unit IP address in xxx.xxx.xxx.xxx format
6) Read Unit Subnet Mask - read the unit subnet mask in xxx.xxx.xxx.xxx format
7) Read Unit Default Gateway - read the unit default gateway in xxx.xxx.xxx.xxx format
8) Read Unit Website Timeout - read the current website timeout period in seconds
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted
- enter the desired IP address in xxx.xxx.xxx.xxx format
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted
- number of digits is minimum 1 and maximum 3 for each field. Leading zeroes are accepted
- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout
- Values: 60, 300, 600, 900, 1800, 3600, 7200, 18000, 28800 0 = no timeout
14
Page 19
NTI VEEMUX VIDEO MATRIX SWITCH
Setup Options
Key Selection Description
1) select Com port current:
(COM1:)
2) select Baud rate current:
(9600)
3) set unit Address current:
(1)
For any selection that requires user input, the user is prompted. When commands are sent to the matrix unit, the command string and matrix unit responses are echoed to the screen. All commands generated by the program are formatted according to the information provided in sections above. If any transmission problems are detected, an error message is displayed.
Press <Esc> or <Enter> to back out to the main menu and press again to exit.
- select PC serial port
- the current PC serial port is displayed in parentheses
- select PC serial port baud rate
- the current baud rate is displayed in parentheses
- select the unit address
- the current address is displayed in parentheses
15
Page 20
NTI VEEMUX VIDEO MATRIX SWITCH
ETHERNET CONTROL
Telnet Interface-Port 2000
The Telnet Interface enables the user to control the switch using telnet client through an Ethernet connection. The telnet server listens on ports 2000 and 2005. Port 2000 is for an operator telnet session (must be enabled-see page 26) while port 2005 is intended for a software control type session (see page 17). For operator telnet control using the telnet interface and the current IP address, type the following in a command shell:
telnet 192.168.1.30 2000
The VEEMUX will prompt the user for a password. The user must enter the password followed by <Enter>.
The factory default password is "nti".
With a proper password sent the VEEMUX will respond with:
Password Successful Connection Established
The following commands are now available:
Command Reply Description
H(elp) or h(elp)
CP
CS nn,mm *<CR> Connect One Output (User Port) To Input (Video source)
Displays the list of commands User is prompted to introduce the password twice
Help
Change password
CA nn *<CR> Connect All Ou tputs To Input RO nn *<CR>mm<CR> CC nn *<CR>nn<CR> RC nn *<CR>nn<CR> CB nn *<CR> RS *<CR> Reset Unit RV 00 *<CR>string\0<CR> Read NTI Version String RU *<CR>nn,mm<CR> Ss nn,dwt *<CR> Gs nn Sa nn,mm *<CR> Set scan list of individual output nn to all inputs mm Sc nn *<CR> Clear scan list of individual output nn S+ nn,mm *<CR> Add input mm to Scan List of output nn
*<CR> dwt<CR>
Read Connection For Output. Returns the number of the input (mm) connected to output nn
Save Matrix Connections Into Memory Bank nn nn should be between 00 and 99
Restore Matrix Connections From Memory Bank nn nn should be between 00 and 99
Change baud rate of serial line, nn=12(00),24(00),48(00),96(00) Factory default is 9,600.
Read Unit Size Returns the number of inputs(nn) and the number of outputs (mm)
Set value of Scan Mode dwell time (see pg. 8) for specific Output (nn) dwt = 000-255 (seconds) 000= disable Scan Mode
Read set Scan Mode dwell time value (dwt) for specific Output (nn) in seconds (see also "Scan Mode" on page 8)
16
Page 21
NTI VEEMUX VIDEO MATRIX SWITCH
S- nn,mm *<CR> Remove input mm from Scan List of output nn Sx nn
<Ctrl>-<X> (see note 4 below)
Notes:
1. The commands must be typed exactl
2. If a mistake is made, the user must backspace to the beginning and completely retype the comma nd.
3. If a command is sent that the VEEMUX does not recognize or exceeds the configuration of the switch, the
reply "?" may be received. Check the command syntax and try again.
4. To quit the telnet session, press the keyboard keys <Ctrl><X>.
*<CR>oooxoxxxooooxxx< CR>
Good Bye. Connection to host lost.
Display the Scan List of output nn (o=skip x=don't skip) Quit telnet session
y as shown in the chart. The commands are case sensitive.
Telnet Interface-Port 2005
For a software control type of telnet interface session (versus operator telnet control through port 2000 as described on page 16), connect to the VEEMUX through the current IP address at port 2005. Use the command set below to control and acquire information from the VEEMUX.
Note After establishing the connection, the unit will answer with *<CR>. If the connection fails or there ar e already 2 connections established, it will answer with ?<CR>
Legend: (All numbers must be two digits) OP : Output Port (01-MAXOUTPUTS)
IP : Input Port (01-MAXINPUTS) <CR> : Carriage Return (Hex 0xD)
Command Summary
Command String Good Response Description
RU<CR> RO OP<CR> pc OP,IP<CR> Read connection for OP CS IP,OP<CR> CA IP<CR> *<CR> Connect all outputs to IP SS 01<CR> *<CR> Enab le auto-status mode SS 00<CR> *<CR> Disable auto-status mode SX<CR> See details Examine connections XX<CR> *<CR> Close connection
A <CR> (carriage return, 0x0D) is considered to be the end of the command string. If a string exceeds 16 characters, an end of string will be inserted automatically to avoid buffer overflow. An eventual <LF> (line feed, new line, 0x0A) after a <CR> will be ignored. A bad string will always be responded to with the ASCII character ‘?’ followed by a <CR>.
ru IP,OP<CR>
*<CR> Connect OP to IP
Read unit size
17
Page 22
NTI VEEMUX VIDEO MATRIX SWITCH
Command Detail
RU-Read Unit Size
Command:
Byte 1 Byte2 Byte3
‘R’
(0x52)
‘U’
(0x55)
<CR>
(0x0D)
Response:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
r
(0x72)
u
(0x75)
Space (0x20)
Input – 1st digit
(0x300x32)
This command will read the size of the unit. The response returns the number of inputs and the number of outputs in two-digit, ASCII code format. If the numbers are smaller than 10, the 1st digit is ‘0’.
Input – 2nd digit
(0x300x39)
,
(0x2C)
Output – 1st digit
(0x300x32)
Output-2nd digit
(0x300x39)
<CR>
(0x0D)
RO-Read Connection for Output Port
Command:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
‘R
(0x52)
‘O’
(0x4F)
Space (0x20)
Response:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
‘p’
(0x70)
‘c’
(0x63)
Space (0x20)
This command will read the connection of an output port. The response returns the output port that is connected to the input port.
Output – 1st digit
Output – 1st digit
(0x300x32)
(0x300x32)
Output-2nd digit
(0x30…0x39)
Output – 2nd digit
(0x300x39)
‘,’
(0x2C)
Input – 1st digit
(0x300x32)
<CR>
(0x0D)
Input – 2nd digit
(0x300x39)
<CR>
(0x0D)
CS- Connect Output Port to Input Port
Command:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
‘C’
(0x43)
Response:
‘S’
(0x53)
Space (0x20)
Input –1st digit
(0x300x32)
Byte 1 Byte 2
(0x2A)
This command connects the specified input port to the specified output port.
<CR>
(0x0D)
CA- Connect All Output Ports to Input Port
Command:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
‘C’
(0x43)
‘A’
(0x41)
Space (0x20)
Response:
Byte 1 Byte 2
(0x2A)
This command connects all output ports to the specified input port.
<CR>
(0x0D)
Input – 1st digit
(0x300x32)
Input –2nd digit
(0x300x39)
Input - 2nd digit
(0x300x39)
18
‘,’
(0x2C)
Output – 1st digit
(0x300x32)
<CR>
(0x0D)
Output – 2nd digit
(0x300x39)
<CR>
(0x0D)
Page 23
NTI VEEMUX VIDEO MATRIX SWITCH
SS_01- Enable Auto Status Mode
Command:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
‘S’
(0x53)
Response:
‘S’
(0x53)
Space (0x20)
‘0’
(0x30)
‘1’
(0x31)
<CR>
(0x0D)
Byte 1 Byte 2
(0x2A)
Auto status mode is disabled by default whenever the connection is established, and this command must be entered to enable it. When auto status mode is enabled, a message will be sent whenever an input/output connection changes from any source. The format of this message is given in the table below. The first two numeric digits are the output port number and the two after the colon are the number of the input port that is now connected to it.
<CR>
(0x0D)
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
‘p’
(0x70)
‘c’
(0x63)
Space (0x20)
Output – 1st digit
(0x300x32)
Output – 2nd digit
(0x300x39)
‘:’
(0x3A)
Input – 1st digit
(0x300x32)
Input – 2nd digit
(0x300x39)
<CR>
(0x0D)
SS_00- Disable Auto Status Mode
Command:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6
‘S’
(0x53)
Response:
Byte 1 Byte 2
‘S’
(0x53)
Space (0x20)
‘0’
(0x30)
‘0’
(0x30)
<CR>
(0x0D)
(0x2A)
This command disables auto status mode.
<CR>
(0x0D)
SX- Examine connections
Command:
Byte 1 Byte 2 Byte 3
‘S’
(0x53)
Response: Multiple lines, one line for each output:
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
‘p’
(0x70)
Byte 1 Byte 2 Byte 3 Byte 4 Byte 5 Byte 6 Byte 7 Byte 8 Byte 9
‘p’
(0x70)
Last line:
Byte 1 Byte 2
‘X’
(0x58)
‘c’
(0x63)
‘c’
(0x63)
<CR>
(0x0D)
Space (0x20)
Space (0x20)
Output – 1st digit
(0x300x32)
Output – 1st digit
(0x300x32)
Output – 2nd digit
(0x300x39)
Output – 2nd digit
(0x300x39)
‘:’
(0x3A)
‘:’
(0x3A)
Input – 1st digit
(0x300x32)
Input – 1st digit
(0x300x32)
Input – 2nd digit
(0x300x39)
Input – 2nd digit
(0x300x39)
<CR>
(0x0D)
<CR>
(0x0D)
(0x2A)
<CR>
(0x0D)
19
Page 24
NTI VEEMUX VIDEO MATRIX SWITCH
Terminate telnet session
Command:
Byte 1 Byte 2 Byte 3
‘X’
(0x58)
Response:
‘X’
(0x58)
<CR>
(0x0D)
Byte 1 Byte 2
(0x2A)
The unit will respond with ‘*’<CR> and close the connection, terminating the telnet session. The unit is then available for future connections.
It is recommended that the XX command is used as it will close the Telnet connection with the server immediately. If the XX command is not used when the client exits, the server will not close the connection until it times out from inactivity (10 seconds). The recommended sequence is: 1) Open connection
2) Send a command
3) Close the connection with XX
<CR>
(0x0D)
20
Page 25
NTI VEEMUX VIDEO MATRIX SWITCH
Web Interface
A user may control the connections of the VEEMUX using a Web Interface via any web browser (see page 1 for supported web browsers). With the VEEMUX connected to a LAN through an Ethernet cable, a user can access the web interface controls inside the VEEMUX.
FYI: To quickly locate a VEEMUX on the LAN and edit the IP address settings, use the Device Discovery Tool (page 34).
To access the web interface, type the current IP address into the address bar of the web browser. Address
To open a SSL-encrypted connection, type: Address
You will be prompted to accept a certificate. Accept the NTI certificate. A "Login Page" will appear.
http://192.168.1.30
https://192.168.1.30
Figure 10- Web interface Login page
Enter the Password
The cursor will be flashing inside the username box. Enter the administrative username (this cannot be changed), then enter the default password:
User Name = root (lower case letters only) Password = nti (lower case letters only)
To change the password, see page 30.
Note: The browser must be configured to accept cookies in order for the user to successfully make use of the web interface.
21
Page 26
NTI VEEMUX VIDEO MATRIX SWITCH
With a successful login, the main menu and Video Switch page will appear.
Blank video to an output
Enable Sequences
Figure 11- Main menu and Video Switch page
From the menu the user can choose from several links to either view the status of the switch or change the configuration of it. As described on the following pages, each link will enable different areas of control.
Video Switch Page
The Video Switch page (above) displays the active connections (shown in orange) and enables the user to control the video connections of the VEEMUX. Up to 100 different connection configurations can be saved and later recalled by any connection method. Scanning Sequences (page 28) for each output can also be enable d.
Note: Changes made using the keypad (page 8) or by another user through the web interface will be updated automatically to your browser every 10 seconds.
Note: Configuration 0 will be automatically loaded when the VEEMUX is powered-up.
To change a connection
and output columns. A black dot will be placed in the circle to indicate the selection. Then press the Submit button. The display will be reloaded with the selections changed to orange to indicate they are now active. Multiple connections can be changed simultaneously.
, click on the radio button (square image with circle in the center) that intersects the input
22
Page 27
NTI VEEMUX VIDEO MATRIX SWITCH
To quickly clear the selected radio buttons
button has not already been pressed with the selections made.
To quickly connect all outputs to a single input
FYI: See page 29 for an example of using the Outputs Scanning Sequen ces feature.
To save a configuraton
desired slot (numbers 0-99) to save the active
will be saved as the configuration.
The webpage configuration that loads after a Save is the configuration that was actually saved.
To load a saved configuration
desired configuration. Then press the Load button. The VEEMUX will make the connections and the screen will refresh to show the connections associated with that configuration selection.
.
To blank the video to a specific output output to place a checkmark in it. The video going to that output will be disabled.
To enable the scanning sequence configured for an output inputs that should be viewed at the output (see page 28) and then click the box to the right of “Sequence Enabled” that corresponds with the desired output to place a checkmark in it. The video viewed from that output will switch from input to input according to the configured sequence.
, from the Stored Configurations user interface, use the drop-down list to select the
, from the Stored Configurations user interface, use the drop-down list to select the
press the Clear Changes button. This will only work if the Submit
, click on the desired input.
configuration into and press the Save button.
Note: This will save the currently active the VEEMUX. If changes have been made in the web interface without first pressing the Submit button, those changes will not yet be part of the active
Note: If changes to the active configuration have been made by another user prior to saving the current connection selections, the changes made by the other user
, click the box to the right of “Blank” that corresponds with the desired
, configure the automatic scanning sequence of
configuration on
configuration.
23
Page 28
NTI VEEMUX VIDEO MATRIX SWITCH
Administration
The Administration section provides links to pages for all configuration options in the VEEMUX switch. The administration section is broken up into 8 topics:
System Assign the switch name and serial port com munication settings Network Assign all network settings for connection to LAN Video Input Names Assign port names to each cable connection from video sources for easy reference Video Output Names Assign port names to each cable connection from display devices for easy reference Scanning Sequence Assign dwell times for each input as it is assigned to each output’s scanning sequence Change Password Change the password used to access the VEEMUX Firmware Update the firmware as new versions beco m e available
System Configuration
On the System Configuration page, under Administration, fields are provided to assign a unique name to the VEEMUX, set the baud rate for serial communications, and the serial address to be used in RS232 commands.
After applying the desired settings, press “Save” to finish.
Figure 12- System Configuration page
24
Page 29
NTI VEEMUX VIDEO MATRIX SWITCH
Network Configuration
ON the Network Configuration page, under Administration, the user can configure the VEEMUX web interface connection. T his will provide access to control of the VEEMUX from any web-accessible computer.
Figure 13- Network Configuration page
Mode – Choose between Static IP assignment and DHCP. IP Address- If using Static IP assignment, enter a valid IP address to use Subnet Mask- Enter a valid subnet mask value Default Gateway- Enter a valid gateway address Preferred DNS- Enter a valid Domain Name Server address (not required) Alternate DNS- Enter a valid alternate Domain Name Server address if desired (not required)
This change will take a few seconds and automatically redirect the user to the IP address specified.
25
Page 30
NTI VEEMUX VIDEO MATRIX SWITCH
If telnet is going to be used to control the VEEMUX, place a checkmark in the “Enable Telnet” block.
If you wish to disable non-secure web access to the VEEMUX, remove the checkmark from “Allow HTTP Access”. With this box empty, only secure shell web access will be allowed.
A standard port number can be assigned for the HTTP (non-secure) and HTTPS (secure) ports, numbers ranging from 0-
65535. Default HTTP port is 80, and default HTTPS port is 443. The Website Timeout option controls how long an inactive web connection will stay logged in. The range is 0-3200 minutes
(0 disables it). Any change to the Website Timeout configuration takes effect immediately. Press the “Save” button to save any changes made.
Video Input Names
From the Administration menu, the Video Input Names page can be displayed. This page enables the Administrator to change the name of the input ports displayed on the Video Switch page.
Figure 14- Video Input Names page
To change an Input Name, enter the name of the port for the desired input port number, and press “Save”. If you make changes and change your mind and want to return the names back to what they were before changing them, press
Reset”. This must be done before pressing the “Save” button, or changes will not be able to be reversed.
26
Page 31
NTI VEEMUX VIDEO MATRIX SWITCH
Video Output Names
From the Administration menu, the Output Names page can be displayed. This page enables the Administrator to change the names of the output ports displayed on the Switch page.
Figure 15- Video Output Names page
To change an Output Name, enter the name of the port for the desired output port number, and press "Save". If you make changes and change your mind and want to return the names back to what they were before changing them, press
Reset”. This must be done before pressing the “Save” button, or changes will not be able to be reversed.
27
Page 32
NTI VEEMUX VIDEO MATRIX SWITCH
Scanning Sequences
From the Administration menu, the Scanning Sequence page can be displayed. T he Scanning Sequence page displays the configuration of an automatic switching sequence from input (video source) to input for ea ch output (monitor).
The page displays:
output number being configured the Scanning Sequence function status for that output the length of time in seconds (dwell time) that each input will be viewed when connected- the dwell
time value ranges from 0-255 seconds
Figure 16- Scanning Sequence page
The output selection at the top of the page can be changed to any output to display the Scan Sequence Input dwell tim e valu es for that output.
The inputs and the amount of time that each will be viewed (0-255 seconds) can be set to cycle sequentially for each connected output. If an input is set to 0 seconds, that input will not be viewed and will be skipped from the scanning sequence. To include an input in the sequence, enter a dwell time period from 1-255 seconds, and press “Save”.
If you make changes and change your mind and want to return the values back to what they were before changing them, press “Reset”. This must be done before pressing the “Save” button, or changes will not be able to be reversed.
To enable the scanning sequence for the output shown, place a checkmark in the “Sequence Enabled” block.
Tip: To quickly enable the scan sequence for multiple outputs, use the “Sequence Enable” blocks found on the Switch Page (page 29).
Note: If only one input has a dwell time value entered, then the output connection to that input will not end when the Scanning Sequence is enabled.
28
Page 33
NTI VEEMUX VIDEO MATRIX SWITCH
Example of using Outputs Scanning Sequences Problem: A synchronous scan is desired for all outputs with a dwell time of 3 minutes per input, and no two outputs should be
looking at the same input at any given time. Solution:
1. Set the dwell time for all inputs listed in each output at 180 seconds (3 minutes). Press “Save” each time changes are made to the selected output. .
2. Go to the Video Switch page (page 18) and set each output to an input of the same number (1 to 1, 2 to 2, 3 to 3, etc..). Click on “Submit” at the bottom of the Video Switch Page to submit selections and establish a connection and starting point for the scanning sequence. (Blocks shown in yellow in the third image indicate connections made.)
3. Click on the “Sequence Enable” box for each output (from the Video Switch Page).
4. Click on “Submit” again to begin the scan ni ng sequence for each output.
From the moment the configuration is submitted, a synchronous scan will begin on all outputs. Each output will connect to its respective input for 3 minutes. After 3 minutes, the outputs will each switch to the next consecutive input and remain connected for 3 minutes. This cycle will continue indefinitely until sequencing is disabled.
Step 4- Click on “Submit” to begin
Step 1- setup dwell times
Step 2- setup starting point for scan and cl ick “Submit”
Step 3- enable scanning sequences and click “Submit”
29
Page 34
NTI VEEMUX VIDEO MATRIX SWITCH
Change Password
From the Administration menu, the Change Password page can be displayed. This page enab les the administrator to change the password used to access the VEEMUX. (This password is also used for the telnet interface.) Be sure to make note of the new password exactly as it is case sensitive. The password must be between 5 and 16 characters in length and can be alphabetical or numeric.
Figure 17- Change Password page
Once the change is made, press “Save” to have it take effect.
30
Page 35
NTI VEEMUX VIDEO MATRIX SWITCH
Update Firmware
From the Administration menu, the Update Firmware page can be displayed. The Update Firmware page shows the current version of the firmware and enables the Administrator to update the firmware to the latest version available. The latest version can be found at http://www.networktechinc.com/download/d-vmtx.html
.
Figure 18- Update Firmware page
WARNING: Failure to carefully follow these directions can permanently damage the VEEMUX. Please read these
directions in full before continuing. Do not, under any circumstances, reset or power-down the VEEMUX while the firmware is being updated. Do not attempt to update the firmware if a power-failure is likely.
Note: The Firmware can only be updated from the non-secure (http) website. If you attempt to access this page from the secure (https) website, you will be automatically redirected to the non-secure site.
To update the firmware:
1. Contact NTI for the latest firmware file name veemux-vga-vx-x.bin (where x.x is the version number)
and copy it to your computer.
2. On the Update Firmware page, in the “Update File” block, browse to the firmware file.
3. Press Upgrade.
Note: If an update is attempted using the wrong firmware for the section an error message will be received. No update will occur.
4. The VEEMUX will upload the firmware and then restart itself (this may take up to 4 minutes), logging out all connections. After the restart, approximately 4 more minutes, the VEEMUX will be ready to resume operation.
If a message appears stating that the Upload has failed, or that a non-fatal error has occurred:
1. Ensure that the file being uploaded is the NTI firmware file.
2. Repeat the process from step 2 above.
Note: The following message does not indicate that damage to the product has occurred.
If a message appears stating that there has been a fatal error:
1. DO NOT RESET OR POWER-DOWN THE VEEMUX.
2. Repeat the update process from the first step 2 above.
3. If you get another Fatal Error message, call NTI tech-support at 1-800-742-8324 or 330­ 562-7070.
FYI: The VEEMUX should continue to run normally unless it is reset. However, damage may have occurred to the web server firmware that will prevent the product from starting up correctly.
31
Page 36
NTI VEEMUX VIDEO MATRIX SWITCH
Standby Mode
From the menu, the user can quickly place the VEEMUX in Standby Mode. When in Standby, the VEEMUX will still be powered­ON but all functions will stop. The VEEMUX will be in a power-saving ready-to-use state.
Figure 19- VEEMUX in Standby Mode
By simply selecting “Standby” from the side menu, the VEEMUX is placed in Standby Mode. When in Standby Mode, the VEEMUX is still operating as configured, but cannot be manipulated further until standby is disabled.
Standby Mode can be disabled either by pressing “Disable Standby” through the web interface (above), by pressing any button on the front panel keypad by using the IR Remote control (optional)
Logout
To quickly logout of the web interface, select “Logout” from the menu. You will immediately be logged out and presented with a login screen.
Figure 20- Logout of the VEEMUX web interface
32
Page 37
NTI VEEMUX VIDEO MATRIX SWITCH
Support
The Support link on the menu drops down to two choices, Manual and Downloads.
The Manual link will open the pdf manual for the VEEMUX. The Downloads link will open the firmware downloads page for the
SM-8X8-15V-LC Video Matrix Switch at NTI. From there you can see what versions of firmware are available and determine if the version in your VEEMUX is current or in need of an upgrade (page 31).
Figure 21- Support Tab
Reboot
To quickly reboot the VEEMUX, select “Reboot” from the side menu. This will force the VEEMUX to power cycle its processor. A reboot will take approximately 45 seconds to occur. Refresh your browser and log back in to the VEEMUX as desired.
Figure 22- System Reboot
33
Page 38
NTI VEEMUX VIDEO MATRIX SWITCH
DEVICE DISCOVERY TOOL
In order to easily locate the VEEMUX on a network, or to change network settings, the NTI Device Discovery Tool may be used. A link to the Discovery Tool is provided on the web page that appears when you insert the instruction manual CD provided into your CD ROM drive. Click on the link or browse the CD and click on the file discover.html . This will open your browser and display the Device Discovery Tool page.
Note: The Discovery Tool requires the Java Runtime Environment to operate. A link to the web page from which it can be downloaded and installed is provided on the CD.
Note: The computer using the Discovery Tool and the VEEMUX must be connected to the same physical network in order for the Device Discovery Tool to work.
Figure 23- Device Discovery Tool page
Use the Device Discovery Tool to display all NTI VEEMUXs on your network, along with their network settings. Follow the instructions on the Device Discovery Tool page to use the tool and to change the device settings if so desired.
34
Page 39
NTI VEEMUX VIDEO MATRIX SWITCH
INFRARED REMOTE CONTROL
The IRT-UNV Infrared Remote Control allows the user to remotely and intuitively control up to 15 NTI SM-nXm-15V-LC video matrix switches providing the ability to route connections, save and recall switch configurations, and put the switch into Standby.
Features:
Routing of video and audio signals together or individually
Ability to switch one input to all outputs
Scroll through inputs for a single output by using the Input +/- keys (similar to changing channels)
Automatically scan through all channels for a single output
Save or Recall up to 10 matrix switch preset configurations
Control up to 15 NTI switches (systems) with a single remote
Put the switch in Standby
Materials
Materials supplied with the IRT-UNV
NTI IRT-UNV Infrared Remote Control
2- AAA Batteries (installed)
:
35
Page 40
NTI VEEMUX VIDEO MATRIX SWITCH
Buttons
The IRT-UNV Infrared Remote Control user interface consists of a keypad with 29 buttons. The buttons have the following functions:
Numerical Values (0-9)
Selects port numbers (for IN, OUT)  Selects memory locations (for saved configurations)
* (Asterisk)
Pressed to select all outputs
OUT
Pressed to indicate an output port selection
IN
Pressed to indicate an input port selection
IN + / -
Cycles through input ports (up or down), connecting to each one (similar to
changing channels)
Note: This affects only the selected output port
SAVE
Pressed to save the current switch configuration (port connections and
volume settings)
Up to 10 configurations can be saved (0-9)
RECALL
Pressed to recall a switch configuration (port connections and volume
settings)
Up to 10 configuration can be recalled (0-9)
SYS
Pressed to select the desired NTI system to be controlled  Only used when controlling multiple systems  Must be followed by a system number: 1-15
ENTER
Pressed to immediately accept the command (normal delay is approx. 5
seconds).
ESC
Pressed to cancel the current command
Note: If the command has not yet been accepted, all button presses in th e command sequence will be cleared
Standby
Pressed to put the unit into or out of standby mode
VIDEO
Pressed prior to entering a port switch command Applies the command to the video signals only (by default, port switch commands are applied to both Audio and Video)
BL
ANK Video
Turns OFF Video for the selected output  Can be used with *(Asterisk button) to turn OFF video for all outputs  Video will be turned ON by pressing the Blank Video button again, or by switching ports
Note: Blank and Un-Blank commands are applied only to the selected output
36
Page 41
NTI VEEMUX VIDEO MATRIX SWITCH
SCAN
Pressed to toggle the scan enable/disable feature for the selected port  Must be preceded by an output port number (1 or 2 digits), or the * (Asterisk) button to toggle all ports
Note: If the dwell time for a port is set for 0 seconds, it will not be scanned (page 28)
AUDIO THIS BUTTON IS NOT USED FOR THIS PRODUCT
VOL + / - THIS BUTTON IS NOT USED FOR THIS PRODUCT
MUTE Audio THIS BUTTON IS NOT USED FOR THIS PRODUCT
PREV -THIS BUTTON IS NOT USED FOR THIS PRODUCT
Operation
Operation of the IRT-UNV is intuitive. The number of button presses required to complete any operation is kept to a minimum. This is accomplished using intelligent soft ware within the NTI Matrix Switch. Additionally, the Matrix Switch allows for multiple ways for the user to complete the same operation – ensuring th at the Remote will work as expected, regardless of who uses it.
Note: For models with audio support, these commands will switch the video and audio signals simultaneously. For independent video and audio switching using the IRT-UNV, see “Independent Video and Audio Control” on page Error! Bookmark not defined..
Changing Ports
The first, and most important operational use of the IR Remote is changing ports of the switch. This requires the
selection of both input and output ports. There are several methods of control.
Channel Surfing
The “IN +/-“ and “SCAN” buttons can be used to surf through input p ort connections. However, since there are multiple outputs/users, the question becomes “which output connection is being changed?” As a re sult, it is required that an output be selected prior to using the “IN +/-“ buttons.
The output port can be selected in two ways:
by pressing the “OUT” button before selecting the output port number
by pressing the “OUT” button after selecting the output port number
In both cases, the user must enter the output port num ber using the Numeric Keys (0-9). However, when the “OUT” button is pressed prior to selecting the port number, there will be a t wo (2) second delay after the last digit of the output port is entered that must expire before the output port is accepted. To avoid this del ay, press the “ENTER” but ton to immediately accep t the port number.
Once the output port has been accepted, there will be a five (5) second timeout, during which the user must press another button (“IN +,” IN -,” or “SCAN”). Each subsequent press of “IN+” or “IN-“ will rene w the timeout, waiting for yo u to press it again (to advance or go back by one more I nput channel). If no new command is sent t o the switch before the timeout expires, the switch will forget the selected output, and pressing the “IN +/-“ buttons will have no effect.
All output channels can surf inputs at once by pressing the “ * “ button prior to pressing the “IN +/-“ buttons.
Examples:
Change connection of Output 1 from Input 1 to Input 3:
<OUT> + <1> + wait 2 seconds + <IN+> + <IN+>
<OUT> + <1> + <ENTER> + <IN+> + <IN+> (must press <IN+> within 5 seconds of pressing <ENTER>)
<1> + <OUT> + <IN+> + <IN+> (must press <IN+> within 5 seconds of pressing <OUT>)
37
Page 42
NTI VEEMUX VIDEO MATRIX SWITCH
Jump To Input
With the output port selected, a user knowing the desired i nput port number can enter it using the Numeric ke ys (0-9). Just as with using the “OUT” button, pressing the “IN” but ton after the number will force the command immediately. If the “IN” button is pressed prior to the port number, the “ENTER” button must be pressed to avoid a two (2) second delay before the in put port is accepted.
Examples:
Quick method to change Output 1 from Input x (any) to Input 8:
<1> + <OUT> + <8> + <IN>
Quick method to change Output 12 from Input x (any) to Input 20:
<1> + <2> + <OUT> + <2> + <0> + <IN>
Jump To Output
Users can also change ports by specifying the input port number first. Similar to selecting the output port first, the “IN” button can be pressed either before or after entering the port number. Once the input port has been selected, the output port can be selected, following the same format as “Jump to Input…”
Expiration of a five (5) second timeout will force the switch to forget the entered input port number.
Example:
Quick method to change Input 1 from Output x (any) to Output 8:
<1> + <IN> + <8> + <OUT> (must enter the <x> + <OUT> command within 5 seconds of pressing <IN>)
Connect All
It may be desirable to broadcast the video (and audio) signals from one input to all of the outputs. In this situation, the user can quickly make all of these connections by using the “ * ” (asterisk) button which selects all outputs. With the input port selected, pressing the “ * “ button will immediately force the command to connect all output ports to the selected input.
Example :
Connect all users to Input 2:
<2> + <IN> + <*>
The “ * “ button can also be pressed prior to selecting the input port. In this case, the command will take effect once the
input port has been selected.
<*> + <2> + <IN>
If no command is received before the five (5) second timeout expires, the switch will forget the “ * “ key-press.
Save and Recall
The SM-8X8-LC-LCD video matrix switches provi de the ability to save a nd recall up to 10 switch configurati ons. The switch configurations define the current port connections and vide o blank status. The IRT -UNV IR Remote can be used to ac cess these configurations by using the “SAVE” and “RECALL” buttons.
To save a configuration, press the “SAVE” button followed by Numeric key(s) 0-99 corresponding t o the memory slot the configuration is to be saved in. After the numeric key(s) press the “Enter” button. If the “Enter” button i s not pressed, after two seconds the function will timeout and the number entered will be saved as that configuration.
Configurations can be recalled in much the same manner. To recall, press the “RECALL” button followed by the numeric key (s) corresponding to the memory slot from which the configuration is to be recalled. After the numeric key(s) press the “Enter” button. If the “Enter” button is not pressed, after two seconds the function will timeout and the number entered will be recalled to the current configuration.
38
Page 43
NTI VEEMUX VIDEO MATRIX SWITCH
Multiple Switch Control
All compatible NTI matrix switches will work with the sam e I RT -UNV IR Re mote co ntrol. As a res ult, a u ser with multiple NTI matrix switches may find that, if the switches are installed too close together, both switches may respond to an IR command intended only for one switch. Or, the user may want to control multiple switches with a single remote, instead of having one remote per switch. To accommodate this situation, the IRT-UNV IR Remote provides the “SYS” but ton, which can be used to select the NTI switch to be controlled.
All switches will have the capability to allo w the user to set the switch address (0-15). Each switch to be separately controlled must be set to a different address prior to using the Remote Control. With the addresses set, press the “SYS” button on the IRT­UNV, followed by a two digit number corresponding to the address of the matrix switch to be controlled.
Upon accepting the “SYS” command, the switch with the corresponding address will illu minate the “IR” LED and respond to all IR Remote commands and will blink the “IR” LED on the front of the switch for visual indicatio n. All other switches will ignore any further commands, until the “SYS” button is pressed again. To select a new NTI switch to control, press the “SYS” button again and repeat the process.
Canceling a Command
Considering the number of key presses required for some of the commands, it’s possible that the us er may inadvertently press an incorrect button. Should this happen, the user can press the “ESC” button to cancel a command. Provid ed the command has not been accepted by the system, pressing the “ESC” button will caus e the switch to “forget” or “erase” all button commands from the current command sequence. Once the command sequence has been cancelled, the user can begin entering the command again.
Technical Specifications For IRT-UNV
Number of Controllable Systems Max: 15 Pushbutton Control 29 keys Power supply 2x AAA Battery
Chassis material Plastic Approvals RoHS
Troubleshooting the IRT-UNV
PROBLEM SOLUTION
IRT-UNV is not selecting outputs or inputs
Check battery
The IRT-UNV may be configured to control the wrong switch- see “Multiple
Switch Control” above.
39
Page 44
NTI VEEMUX VIDEO MATRIX SWITCH
RS232 CONNECTION CABLE
Pinout for Matrix Y-1 Cable
Arrows indicate signal direction.
Wiring Schematic of Matrix-Y-1 cable
(Unit #1)
23 33
555
9D Female9D Male 9D Male
(Source)
(Unit #2)
Not connected to source connector
22
7
Jumper
8 1
Jumpers
4 6
SPECIFICATIONS
General Information
DESCRIPTION SPECIFICATION
Operating temperature 0°C - 38°C (32°F - 100°F) (17-90% non-condensing RH) Storage temperature -30°C - 60°C (-20°F - 140°F) (17-90% no n-condensing RH) Power requirements 110 or 220VAC @ 50 or 60Hz Fuse protection 2A 240VAC Fast-blo Video Connectors 15HD female Maximum Resolution 1920 x 1200 @ 60Hz Video Signal : Video Bandwidth Sync Ethernet Connector RJ45 female, 10BaseT RS232 Connector RJ45 female, 1200-115200 bps
Available Sizes
NTI Part # Desktop Size
(In.) WxDxH
SM-4X2-15V-LC 10.9x6x1.75 19x6x1.75 SM-4X4-15V-LC 10.9x6x1.75 19x6x1.75 SM-8X2-15V-LC 15.3x7.7x1.75 19x7.7x1.75 SM-8X4-15V-LC 15.3x7.7x1.75 19x7.7x1.75 SM-8X8-15V-LC 15.3x7.7x1.75 19x7.7x1.75
RGB analog (75 ohms, 0.7 Vp-p) 160MHz (typ) or greater H/V separated (TTL), composite, sync-on-green
Rack Size (In.) WxDxH
40
Page 45
NTI VEEMUX VIDEO MATRIX SWITCH
TROUBLESHOOTING
Problem Solution
No Video - Check power – power ON, power cable connected
- Check video cabling – make sure cab les are secured
- Check connections – make sure you’re connected to an active input
SAFETY STATEMENTS
Grounding
These products have protective earth ground terminals and are built with full attention to consumer safety. There must be an un­interruptible safety earth ground between the main power source and the product's power cord or supplied power cord set. If ever the possibility exists for the grounding protection to have been reduced in any way, disconnect the power supply until the grounding connection has been fully restored.
Servicing
NTI products are not intended to be serviced in the field and contain no user-serviceabl e parts. In the event repair is needed, all servicing must be performed by factory trained and authorized service personnel. Only those items specifically ide ntifi ed in this manual (if any) may be adjusted by the user of this product and adjusted only as instructed in this manual.
INDEX
Autostatus, 13 bandwidth, 1 baud rate, 10 cables, 2 change password, 30 Device Discovery Tool, 34 Ethernet connection, 6 firmware, 31 front panel LCD, 8 grounding, 41 IP address, 21, 25 IRT-UNV, 35 Java, 34 LAN, 6, 21 Matrix-Y-1 cable, 10 NTI Switch Control Program, 13 password, 2, 21 rack mounting, 4 reboot, 33 resolution, 1
RS232 control, 6 RS232 Control, 10 RS232 pinout, 10 RS232 port, 3 Scanning Sequences, 28 SERTEST, 14 servicing, 41 Specifications, 40 standby mode, 32 Telnet Interface, 16 Telnet Interface-Port 2005, 17 Telnet password, 16 Telnet- Port 2000 Protocol, 16 Telnet-Port 2005 Protocol, 17 terminal, 6 username and password, 21 video sources, 5 Video Switch, 22 web browsers, 1
41
Page 46
NTI VEEMUX VIDEO MATRIX SWITCH
WARRANTY INFORMATION
The warranty period on this product (parts and labor) is two (2) years from the date of purchase. Please contact Network Technologies Inc at (800) 742-8324 (800-RGB-TECH) or (330) 562-7070 or visit our website at http://www.networktechinc.com for information regarding repairs and/or returns. A return authorization number is required for all repairs/returns.
Man156 Rev 8/1/12
42
Loading...