Network Technologies SERIMUX-S-x, SERIMUX-S-4, SERIMUX-S-8, SERIMUX-S-16, SERIMUX-S-24 Installation Manual

...
SERIMUX®Series
SERIMUX-S-x
SECURE SSH CONSOLE SERIAL SWITCH
Installation and Operation Manual
MAN107 V1.20 Rev 6/4/09
TRADEMARK
SERIMUX is a registered trademark of Network Technologies Inc in the U.S. and other countries.
COPYRIGHT
Copyright © 2009 by Network Technologies Inc. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior written consent of Network Technologies Inc, 1275 Danner Drive, Aurora, Ohio 44202.
This product contains software licensed under the GNU Public License version 2 and other open source licenses. ( http://www.gnu.org/copyleft/gpl.html You may obtain the complete open-source code free of charge from Network Technologies Inc (send email to tech­consult@ntigo.com) for more information.
)
CHANGES
The material in this guide is for information only and is subject to change without notice. Network Technologies Inc reserves the right to make changes in the product design without reservation and without notification to its users.
FIRMWARE VERSION
Current Firmware Version 1.20
CE Statement
We, Network Technologies Inc, declare under our sole responsibility that the SERIMUX-S-4/8/16/24/32 are in conformity with European Standard EN55022.
Typographic Conventions
The table below offers examples of text format and the meaning when that format is used when the font varies from the standard font (Helvetica) used in this manual.
Typeface meaning Font Configuration Example
On-screen computer output Courier New-(not bold) What you type on the computer Courier New-bold Characters to be typed as instructed within the body of a paragraph Place holder-description of other data to enter
Courier New-bold Surrounded by < > <L>
Helvetica-Italic
C:> C:>edit text.bat
Hostname
i
TABLE OF CONTENTS
Introduction.................................................................................................................................................................... 1
Serial Interface Specifications ..................................................................................................................................... 1
Network Interface ........................................................................................................................................................1
RJ45 Sensor Ports ......................................................................................................................................................1
Protocols...................................................................................................................................................................... 2
Supported Web Browsers ...........................................................................................................................................2
Definitions.................................................................................................................................................................... 2
Materials ......................................................................................................................................................................3
Default User Name and Password............................................................................................................................... 4
Features and Functions................................................................................................................................................ 5
Installation...................................................................................................................................................................... 6
To Mount to a Rack ..................................................................................................................................................... 6
Cable Connections ...................................................................................................................................................... 7
Connect to the Ethernet ..............................................................................................................................................7
Dual Power Option ...................................................................................................................................................... 8
DC Power Option......................................................................................................................................................... 8
Connect Sensors ......................................................................................................................................................... 9
Initial Startup ...............................................................................................................................................................10
Connect Direct to Serial Port from Command Line ................................................................................................11
Connect Via Telnet .............................................................................................................................................. 11
Connect Via SSH................................................................................................................................................. 11
Using the SERIMUX Console Switch......................................................................................................................... 12
Serial Control- Administrator..................................................................................................................................... 12
Login as the administrator .........................................................................................................................................13
Port Management...................................................................................................................................................... 14
Common Settings................................................................................................................................................ 15
Port Settings ...........................................................................................................................................................15
Serial Settings......................................................................................................................................................... 16
Port Logging............................................................................................................................................................ 17
Modem Setting........................................................................................................................................................18
Authentication ......................................................................................................................................................... 18
Event Notification .................................................................................................................................................... 19
Port Access List ...................................................................................................................................................... 20
Port Disconnect....................................................................................................................................................... 21
Apply Common Settings ......................................................................................................................................... 22
Network Management ............................................................................................................................................... 23
IP Configuration ...................................................................................................................................................... 23
Server Configuration............................................................................................................................................... 25
SNMP .................................................................................................................................................................. 27
TCP Setting............................................................................................................................................................. 27
Administration Settings.............................................................................................................................................. 28
Unit Settings............................................................................................................................................................ 28
ii
Unit Setting->Change Admin Password..............................................................................................................28
Unit Settings->Date Time Settings ...................................................................................................................... 29
Security Settings ..................................................................................................................................................... 31
Syslog ..................................................................................................................................................................... 32
Firmware Update .................................................................................................................................................... 34
User Management..................................................................................................................................................... 36
System Users.......................................................................................................................................................... 36
Access Group .........................................................................................................................................................37
Administrative Info ..................................................................................................................................................... 38
System Log ............................................................................................................................................................. 38
System Information ................................................................................................................................................. 39
Network Information................................................................................................................................................ 39
Port List................................................................................................................................................................... 40
Reboot .......................................................................................................................................................................40
Serial control-Users .................................................................................................................................................... 41
User "Accessible host list" screen ............................................................................................................................. 41
Device Discovery Tool................................................................................................................................................ 42
Web Interface............................................................................................................................................................... 43
Enter the Password ................................................................................................................................................43
Menu Overview.......................................................................................................................................................... 44
Main Menu and Port List ...........................................................................................................................................45
Connect to a Port .................................................................................................................................................... 45
Port Management...................................................................................................................................................... 48
Port Configuration................................................................................................................................................... 48
Port Configuration->Port Settings .......................................................................................................................48
Port Configuration->Serial Settings..................................................................................................................... 49
Port Configuration->Port Logging........................................................................................................................ 49
Port Configuration->View Port Log...................................................................................................................... 50
Port Configuration->Modem Settings ..................................................................................................................50
Port Configuration->Authentication ..................................................................................................................... 50
Port Configuration->Event Notification ................................................................................................................ 51
Port Configuration->Port Access List .................................................................................................................. 51
Port Configuration->Apply Common Settings .....................................................................................................51
Port Configuration->Disconnect Port................................................................................................................... 52
Common Port Configuration Page.......................................................................................................................... 52
Copy Paste Port...................................................................................................................................................... 53
Base TCP Port..................................................................................................................................................... 53
Network Management ............................................................................................................................................... 54
IP Configuration ...................................................................................................................................................... 54
Server Configuration............................................................................................................................................... 55
SNMP .................................................................................................................................................................. 56
TCP Settings...........................................................................................................................................................56
Administrative Settings.............................................................................................................................................. 57
Unit Settings............................................................................................................................................................ 57
Unit Settings->Admin Password.......................................................................................................................... 57
Unit Settings->Date and Time Settings ...............................................................................................................58
iii
Security Settings ..................................................................................................................................................... 59
Syslog ..................................................................................................................................................................... 60
Firmware Update .................................................................................................................................................... 61
User Management..................................................................................................................................................... 62
System Users.......................................................................................................................................................... 62
Access Groups........................................................................................................................................................ 64
Administrative Information......................................................................................................................................... 65
System Log ............................................................................................................................................................. 65
System Information ................................................................................................................................................. 65
Network Information................................................................................................................................................ 66
Support ......................................................................................................................................................................66
Reboot .......................................................................................................................................................................67
Logout........................................................................................................................................................................ 67
Telnet Or SSH Connection .........................................................................................................................................68
Telnet via HyperTerminal........................................................................................................................................ 68
Telnet via Command Prompt .................................................................................................................................. 68
RESET Button.............................................................................................................................................................. 69
Change Console Port Baud Rate............................................................................................................................... 69
Interconnection Cable Wiring Method ......................................................................................................................70
Troubleshooting ..........................................................................................................................................................70
Specifications .............................................................................................................................................................. 75
Index ............................................................................................................................................................................. 76
Warranty Information .................................................................................................................................................. 76
TABLE OF FIGURES
Figure 1- Secure rack mount ears to switch.......................................................................................................................................6
Figure 2- Secure switch to a rack ......................................................................................................................................................6
Figure 3- Connect terminals and devices to SERIMUX Console Switch............................................................................................ 7
Figure 4- Connect the LAN to the SERIMUX ..................................................................................................................................... 7
Figure 5- Power connections for SERIMUX with Dual Power option .................................................................................................8
Figure 6- Power connections for SERIMUX with DC power option.................................................................................................... 8
Figure 7- Connect sensors to the SERIMUX .....................................................................................................................................9
Figure 8- SERIMUX Secure configuration menu via serial connection ............................................................................................ 10
Figure 9- Serimux Secure Port Connect menu ................................................................................................................................ 11
Figure 10- Serimux Secure Configuration menu.............................................................................................................................. 13
Figure 11- Port Management- complete ports list ............................................................................................................................ 14
Figure 12- Port Management selections for Port 1 ..........................................................................................................................14
Figure 13- Port Management- configure common settings for most ports .......................................................................................15
Figure 14- Port Management- port settings for Port 1...................................................................................................................... 15
Figure 15- Port Management-serial settings for Port 1 .................................................................................................................... 16
Figure 16- Port Management-port logging for Port 1 .......................................................................................................................17
Figure 17- Port Management-modem setting for Port 1................................................................................................................... 18
Figure 18- Port Management-authentication for Port 1.................................................................................................................... 18
Figure 19- Authentication server configuration ................................................................................................................................19
iv
Figure 20- Port Management- event notification for Port 1 ..............................................................................................................19
Figure 21- Port Management-port access list for Port 1...................................................................................................................20
Figure 22- Port Management-add users to access list..................................................................................................................... 20
Figure 23- Port Management-add group to access list ....................................................................................................................20
Figure 24- Port Management- remove group from access list ......................................................................................................... 21
Figure 25- Port Management- disconnect Port 1 ............................................................................................................................. 21
Figure 26- Port Management- apply common settings to Port 1...................................................................................................... 22
Figure 27-Network Management menu............................................................................................................................................ 23
Figure 28- Network Management-IP Configuration.......................................................................................................................... 23
Figure 29- Network Management-IPv4 settings............................................................................................................................... 23
Figure 30- Network Management- IPv6 settings.............................................................................................................................. 24
Figure 31- Network Management-IPv6 manual IP assignment........................................................................................................ 24
Figure 32-Network Management- Server Configuration................................................................................................................... 25
Figure 33- Network Management- Web Server settings ..................................................................................................................25
Figure 34- Network Management- SMTP server settings ................................................................................................................25
Figure 35- Network Management- NFS server configuration...........................................................................................................26
Figure 36- Network Management-SNMP configuration.................................................................................................................... 26
Figure 37- Network Management-TCP settings............................................................................................................................... 27
Figure 38- Administration Settings................................................................................................................................................... 28
Figure 39- Administration Settings-Unit Settings .............................................................................................................................28
Figure 40-Unit Settings-change password ....................................................................................................................................... 29
Figure 41- Unit Settings-manual date and time................................................................................................................................ 29
Figure 42-Unit Settings-NTP Server settings ................................................................................................................................... 30
Figure 43- Unit Settings-Daylight Savings .......................................................................................................................................30
Figure 44- Administration Settings-Security Setting......................................................................................................................... 31
Figure 45- Administration Settings-CLI Authentication Types..........................................................................................................31
Figure 46- Administration Settings-Security-CLI Authentication ......................................................................................................32
Figure 47- Administrative Settings-Syslog .......................................................................................................................................32
Figure 48- Administration Settings-System Log settings..................................................................................................................33
Figure 49- Administration Settings-Syslog-ng Configuration............................................................................................................33
Figure 50- Administration Settings-Firmware Update ...................................................................................................................... 34
Figure 51- Change path from tftp source to flash drive.................................................................................................................... 34
Figure 52- Firmware update- confirm to perform update.................................................................................................................. 35
Figure 53- Firmware update- Completed ......................................................................................................................................... 35
Figure 54- User Management menu ................................................................................................................................................36
Figure 55- User Management- System Users.................................................................................................................................. 36
Figure 56- User Management-Configure User................................................................................................................................. 36
Figure 57- User Management-Access Groups................................................................................................................................. 37
Figure 58- User Management- Group User List............................................................................................................................... 37
Figure 59- Administrative Info menu ................................................................................................................................................38
Figure 60- Administrative Info-System Log ...................................................................................................................................... 38
Figure 61- Administrative Info-System Information .......................................................................................................................... 39
Figure 62- Administrative Info-Network Information......................................................................................................................... 39
Figure 63- Administrative Info-Port List............................................................................................................................................ 40
Figure 64- Reboot the SERIMUX from the shell .............................................................................................................................. 40
Figure 65- A user with limited host port access ...............................................................................................................................41
Figure 66- Device Discovered.......................................................................................................................................................... 42
Figure 67- Web interface Login page.............................................................................................................................................. 43
Figure 68- Connect Port/Port List Page ...........................................................................................................................................45
Figure 69- SSH Port connection via Java Applet .............................................................................................................................46
v
Figure 70- SSH Port connected ....................................................................................................................................................... 46
Figure 71- Serial connection-"offline"-properly exited ......................................................................................................................47
Figure 72- Port Configuration page.................................................................................................................................................. 48
Figure 73- Port Settings ................................................................................................................................................................... 48
Figure 74- Serial Settings ................................................................................................................................................................49
Figure 75- Port Logging settings......................................................................................................................................................49
Figure 76- View or Clear Port Log ...................................................................................................................................................50
Figure 77- Modem settings .............................................................................................................................................................. 50
Figure 78- Authentication method options .......................................................................................................................................50
Figure 79- Port event notifications ...................................................................................................................................................51
Figure 80- Port Access List..............................................................................................................................................................51
Figure 81- Apply common settings to port .......................................................................................................................................51
Figure 82- Disconnect Port button ................................................................................................................................................... 52
Figure 83- Common Port Configuration page .................................................................................................................................. 52
Figure 84- Copy Paste Port page ....................................................................................................................................................53
Figure 85- IP Configuration page..................................................................................................................................................... 54
Figure 86- Server Configuration Page .............................................................................................................................................55
Figure 87- NFS Configuration settings............................................................................................................................................. 56
Figure 88- TCP Settings page .........................................................................................................................................................56
Figure 89- Unit Settings page .......................................................................................................................................................... 57
Figure 90- Change password for user "root".................................................................................................................................... 57
Figure 91- Unit Settings page, date and time................................................................................................................................... 58
Figure 92- Security Settings page.................................................................................................................................................... 59
Figure 93- Syslog page.................................................................................................................................................................... 60
Figure 94- Firmware Update page ................................................................................................................................................... 61
Figure 95- Firmware Update- file selected ....................................................................................................................................... 61
Figure 96- Firmware update done.................................................................................................................................................... 61
Figure 97- Firmware update failure.................................................................................................................................................. 62
Figure 98- System User page .......................................................................................................................................................... 62
Figure 99- User configuration ..........................................................................................................................................................63
Figure 100- Access Groups page .................................................................................................................................................... 64
Figure 101- Edit user names listed in Access Group .......................................................................................................................64
Figure 102- System Log displayed ..................................................................................................................................................65
Figure 103- System Information page.............................................................................................................................................. 65
Figure 104- Network Information page.............................................................................................................................................66
Figure 105- Support Links................................................................................................................................................................ 66
Figure 106- Reboot page ................................................................................................................................................................. 67
Figure 107- Logout screen............................................................................................................................................................... 67
Figure 108- Telnet connection via HyperTerminal ...........................................................................................................................68
Figure 109- Location of RESET button ............................................................................................................................................69
Figure 110- View looking into RJ45 female...................................................................................................................................... 70
vi
APPENDICES
Appendix A - SERIMUX Port Characteristics................................................................................................................................... 71
Appendix B-SERIMUX User and Administrator Characteristics.......................................................................................................71
Appendix C- Cable Adapters ...........................................................................................................................................................72
Appendix D- Common Commands from Shell Command Line ........................................................................................................ 74
Appendix E- SERIMUX-S-x Default Paths....................................................................................................................................... 74
Appendix F- SERIMUX-S-x Default Network Settings ..................................................................................................................... 74
vii
NTI SERIMUX SERIES SSH CONSOLE SWITCH
INTRODUCTION
The NTI SERIMUX-S-x SSH Console Serial Switch (SERIMUX) is a serial port switch that delivers secure management of up to 32 serial devices via the internet, TCP/IP network, or dial-up modem connections. It combines the advanced security of Secure Shell v2 with unlimited access to remote network management. The SERIMUX-S-x allows links (or connections) between multiple pairs of RS232 asynchronous serial ports. The SERIMUX-S-x (x=4,8,16,24,or 32) is available with up to 32 serial port connections.
The main purpose of the switch is to provide secure management of several serial devices from local or remote locations (using Ethernet or external modems). Devices include routers, DSU's, servers, switches or any other equipment allowing serial operation using RS232 interface. Users can work locally using a VT100 or ANSI serial console, a CPU with a terminal program (i.e. HyperTerminal)) or from remote locations via Ethernet connection (Web Interface, SSH, Telnet).
Each SERIMUX port has to be configured for serial communication (baud rate, parity, etc) within the specifications of the attached serial device, but the configurations of the two devices linked by the SERIMUX do not need to match. Various parameters (communication speed, hardware and/or software flow control, timeout, etc) can be selected for each SERIMUX port. Devices may be either locally connected or connected through attached modems.
Each SERIMUX port can be configured as either a host or user port. Serial hosts (such as servers, switches etc.) are connected to host ports, while serial user devices (such as a terminal or serial console) are connected to user ports.
The SERIMUX supports two operator levels: user and administrator. Users may login and connect to serial devices attached at host ports. The administrator and users with administrative privileges can see and/or modify various port or user parameters in addition to connecting to serial devices attached at host ports.
Option:
Dual AC Power Option- includes a second power connector for a secondary AC power supply cable- to order, add a
“DP” to the part number (i.e. SERIMUX-S-xDP)
DC Power Option- SERIMUX designed for connection of 36-72VDC (48VDC nominal) for use in a Telecom
environment- to order add “-48V” to the part number (i.e. SERIMUX-S-x-48V)
Dual DC Power Option- includes a second terminal block power connection for a secondary 48VDC power supply- to
order add a “-48VDP” to the part number (i.e. SERIMUX-S-x-48VDP)
Serial Interface Specifications
Serial ports: 4,8,16,24 or 32 RJ45 RS232 serial port connections
Console port: 1-RJ45 RS232 console port connector
Data: asynchronous, 5, 6, 7, or 8 bits per character
Parity: even, odd, or none
Stop Bits: 1 or 2 bits
Flow Control: Xon/Xoff, RTS/CTS, Both, or None
Baud Rate: 50 bps to 115200 bps between ports
Two connecting ports can be at different baud rates
Network Interface
Two 10/100 Base-T Ethernet ports with RJ45 Ethernet connector
Supports both static and dynamic IP addresses
RJ45 Sensor Ports
(Not supported as of this printing)
Two RJ45 modular jacks for connecting NTI temperature, humidity, temperature/humidity, and liquid detection sensors.
1
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Protocols
SSH V2, Telnet ,IPMI
IPV4, IPV6
TCP/IP, TFTP, DHCP, ICMP, UDP, ARP
HTTP, HTTPS, SMTP, SNMP V1/V2c, Syslog, SMTP
IPMI v2, RMCP
Alerts are sent using email, and/or SNMP traps when any monitored environmental condition exceeds a user-specified
range or a serial port is connected or disconnected.
Supported Web Browsers
Most modern web browsers should be supported. The following browsers have been tested:
Microsoft Internet Explorer 6.0 or higher
Netscape 7.0 or higher
Mozilla FireFox 0.9.2 or higher
Opera 9.0 or higher
Set your browser to always check if there is a newer version of the page than the version stored in cache. This action will ensure that it will display the most up-to-date information.
Definitions
device equipment that can transmit and/or receive data using RS232 interface host serial device that performs a function or stores data to be controlled by a user inactivity when a port is not receiving data from the device connected to it terminal program a terminal emulation program- computer program that communicates via RS232 interface
(i.e. HyperTerminal) "dumb" terminal serial terminal device or CPU terminal program that emulates a serial terminal timeout time period of inactivity after which a port will be disconnected (the inter-port connection will be broken) baud rate serial device or port receiver and transmitter speed; measured in "bps" (bits per second) flow control a method to temporarily stop and restart serial data transfer (flow). It can be
- Hardware (out-band)- usually using the RTS and CTS physical handshaking signals;
- Software (in-band)- using special characters, usually named Xon and Xoff, inserted
in data being transferred;
- Both
2
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Materials
Materials Supplied with this kit:
SERIMUX-S-x
IEC Power cord 5 Foot RJ45-to-
(country specific) RJ45 Cat5 (x2 with Dual AC Patch Cable power option)
(6 feet of 22AWG 2-wire cable provided for models with DC power connectors)
Rubber Feet
Rack mount ears kit
Materials Required but not supplied:
Serial cable with at least one RJ45 male end for connection to the Console Switch from each device to be connected. See Interconnection Cable Wiring Method on page 70 for cable pinout.
Manual CD
Quick Start Guide and Administrator’s Note
DB9F-RJ45F Serial Adapter
DB25M-RJ45F-C Modem Adapter
4-#10-32 X ¾” Pan Head Screws
4-#10-32 Cage Nuts
DB25F-RJ45F Console Adapter
DB25M-RJ45F-T Console Adapter
3
NTI SERIMUX SERIES SSH CONSOLE SWITCH
DEFAULT USER NAME AND PASSWORD
The default user name is root (lower case letters only).
The default password
is nti (lower case letters only).
4
NTI SERIMUX SERIES SSH CONSOLE SWITCH
FEATURES AND FUNCTIONS
NTI
Network Technologies Inc
R
PWR 1
PWR 2
P W R 1
2A,250V2A,250V
2
3
4
1. STATUS LEDs- LEDs will illuminate to indicate the SERIMUX is ON, activity on connected ports, or if there are alerts
2. PWR1- IEC Connector- for connection of AC power cord
3. PWR2- IEC Connector- for connection of second AC power cord for redundant power source (models with Dual AC Power
option only)
4. Power Switch- for turning the SERIMUX ON or OFF
5. Port connectors- RJ45 female serial connectors- for connecting serial cables from serial devices or user terminals
6. USB Devices- USB Type A female connector- for connecting USB flash drive for various data storage options
7. Reset button- For power cycling the SERIMUX firmware without powering down the SERIMUX
8. Console Port- RJ45 female serial connector- for connecting serial cable from a terminal console
9. Ethernet 1- RJ45 female connector- for connection of CAT5 cable to Local Area Network (LAN) for WEB interface
10. Ethernet 2- RJ45 female connector- for redundant connection of CAT5 cable to Local Area Network (LAN) for WEB
interface
11. RJ45 Sensors- RJ45 female connector- for connection of CAT5 cables to optional sensors (not supported as of this
printing)
Front and Rear Views of SERIMUX-S-16DP
Ext
9 10111213141516Pwr
SERIMUX
R
SECURE
Alert
Int
234567810
Alert
1
AC INPUT 100-240VAC 15W
P W R 2
5
11
NTI
6
R
NETWORK TECHNOLOGIES INCORPORATED
RESET
7
1275 Danner Dr Aurora, OH 44202
www.networktechinc.com
CONSOLE
8
Tel:330-562-7070 Fax:330-562-1999
9
910111213141516
12345678
RJ45 SENSORS
ETHERNET 2ETHERNET 1
10
5
NTI SERIMUX SERIES SSH CONSOLE SWITCH
INSTALLATION
This NTI switch was designed to be mounted to a rack or to set on a desktop. It includes rack mount ears to make attachment to a rack easy, and rubber feet to be applied to the bottom of the case if it will instead sit on a flat surface. If this will sit on a flat surface, simply apply the rubber feet to the bottom of the case in each of the 4 corners.
To Mount to a Rack
1. Attach the ears to the switch using the #6-32x3/16" flat Phillips-head screws (6) provided as shown in the illustration below. The holes in the ears should line up with pre-threaded holes in the sides of the NTI switch. Tighten the screws securely.
Figure 1- Secure rack mount ears to switch
2. Install 4 cage nuts (supplied) to the rack in locations that line up with the holes in the mounting ear on the NTI switch.
3. Secure the NTI switch to the rack using four #10-32X3/4” screws (supplied). Each screw should be of sufficient length to go completely through the NTI mounting ear, rack frame and fully engage all threads in the cage nut. Be sure to tighten all mounting screws securely.
4. Attach all cables securely to the switch and where necessary supply adequate means of strain relief for cables.
Figure 2- Secure switch to a rack
Front of Switch
NTI Switch
#10-32x3/4"
Rack Screws
(supplied)
NTI Switch
6-32x3/16" Flat Head Screws (supplied)
Rack mount ear
Rack
Cage Nuts
(supplied)
6
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Cable Connections
1. Connect a serial console to the port labeled "CONSOLE" on the SERIMUX using a serial cable with an RJ45 male connector
(Cat5 patch cable supplied). This will be the default administrator device. (Figure 3)
2. Connect each additional serial user device or host device to be connected by the SERIMUX to any remaining port (1-
4/8/16/24/32) using a serial cable with an RJ45 male connector (see cable specification on page 70). It may be necessary to add one of the cable adapters (supplied) detailed in Appendix C (page 72) between the device port on the serial user device or host device and the RJ45 connector.
3. Follow the "Initial Startup" instructions on page 10.
PWR 2PWR 1
AC INPUT 100-240VAC
P W R 1
15W
P W R 2
2A,250V2A,250V
Note: There are two types of serial devices, data communication equipment (DCE)(i.e. modem) and data terminal equipment (DTE) (i.e. CPU), each having different connector pin assignments. The cable adapters (see Appendix C on page 71) make the proper connections.
RJ45 Male Connector
Ethernet cable
FIREWALL
Figure 3- Connect terminals and devices to SERIMUX Console Switch
Rear View of SERIMUX-S-16DP
8
567
ROUTER
4
SERVER
910111213141516
123
PBX
NTI
R
NETWORK TECHNOLOGIES INCORPORATED
RESET
1275 Danner Dr Aurora, OH 44202
www.networktechinc.com
CONSOLE
Tel:330-562-7070 Fax:330-562-1999
USER DEVICE (VT100, ANSI serial console, PC w/ Terminal Emulation Program)
RJ45 Male Connector
RJ45 SENSORS
ETHERNET 2ETHERNET 1
Connect to the Ethernet
If the Ethernet connection is made, the Web Interface (page 43) can be used. Up to two Ethernet connections to a Local Area Network (LAN) can be made using Cat5 cable with RJ45 connectors attached. Wiring between connectors should be straight through (pin 1 to pin 1, pin 2 to pin 2, etc.). Connect a Cat5 cable between the connector labeled "ETHERNET 1" and the LAN (see Figure 4). For a redundant connection, attach a second Cat5 cable between the connector labeled “ETHERNET 2” and the LAN.
PWR 2PWR 1
AC INPUT 100-240VAC 15W
P W R 1
P W R 2
2A,250V2A,250V
RJ45 male connector
LAN #1
Internet
Figure 4- Connect the LAN to the SERIMUX
Rear View of SERIMUX-S-16DP
16
8
131415
567
12
4
RJ45 male connector
VGA
Multi-Scan
Monitor
User with SSH v2
91011
NTI
123
LAN #2
R
NETWORK TECHNOLOGIES INCORPORATED
RESET
Internet
1275 Danner Dr Aurora, OH 44202
www.networktechinc.com
CONSOLE
Tel: 330 -56 2- 707 0 Fax:330-562-1999
Multi-Scan
Monitor
RJ45 SENSORS
ETHERNET 2ETHERNET 1
VGA
User with SSH v2
7
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Dual Power Option
The SERIMUX-S-xDP has two IEC connectors on the rear, for connection to two separate power sources. If the power source connected to “PWR 1” fails, the SERIMUX will automatically and without interruption switch over to the power source connected to “PWR 2”.
Note: If only one power source is used, it should be connected to “PWR 1”.
PWR 1 PWR 2
PWR 1
PWR 2
AC INPUT 100-240VAC 15W
P W R 1
P W R
2
2A,250V2A,250V
UPS 1
UPS 2
Figure 5- Power connections for SERIMUX with Dual Power option
Rear View of SERIMUX-S-16DP
910111213141516
12345678
Uninterruptible Power Supplies
To Circuit #2
To Circuit #1
NTI
R
NETWORK TECHNOLOGIES INCORPORATED
RESET
1275 Danner Dr Aurora, OH 44202
www.networktechinc.com
CONSOLE
Tel: 330 -56 2- 707 0 Fax:330-562-1999
RJ45 SENSORS
ETHERNET 2ETHERNET 1
DC Power Option
The SERIMUX-S-x-48V has connections on the rear for a user-supplied 48VDC power supply. This is typically used when the SERIMUX is installed in a Telecom environment. The SERIMUX-S-x-48V will accept a DC power source between 36~72VDC (48VDC nominal), positive or negative polarity. A removable 3-pole screw terminal is provided for easy connection. The image below shows a SERIMUX-S-32-48V, but is also available with dual 48VDC power connections for a dual power supply option (model SERIMUX-S-32-48VDP).
36-72VDC, 2A
+
www. networ ktechi nc.com
Loosen screws to remove terminal block
Figure 6- Power connections for SERIMUX with DC power option
NTI
1275 Danner Dr Aurora, OH 44202 Tel:330-562-7070 Fax:330-562-1999
R
Chassis ground
Rear View of SERIMUX-S-32-48V
RESET
CONSOLE
RJ45 SENS ORS
ETHERNET
2
1
32
31
16
28
2930
12
131415
24
252627
91011
23
8
20
2122
4
567
171819
123
+
48VDC
+
Power Supply
8
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Connect Sensors
(not supported as of this printing)
The SERIMUX-S-x has two RJ45 connectors for attachment of up to two sensors to monitor environmental conditions. Sensors can be connected to measure temperature (ENVIROMUX-STS), humidity (ENVIROMUX-SHS), temperature and humidity (ENVIROMUX-STHS), temperature and wide range humidity (ENVIROMUX-STHS-99). A sensor can also be connected to detect liquids (ENVIROMUX-LDSx-y). All sensors are sold separately.
P W R 1
ENVIROMUX-STS
Temperature Sensor
Figure 7- Connect sensors to the SERIMUX
AC INPUT
PWR 2PWR 1
100-240VAC 15W
P
W
R 2
2A,250V2A,250V
RJ45-male connector
16
RJ45-male connector
Cat5 cable (up to 1000 ft)
Rear View of SERIMUX-S-16DP
131415
12
91011
NTI
12345678
ENVIROMUX-LDSx-y
Liquid Detection Sensor
RJ45-male connector
R
NETWORK TECHNOLOGIES INCORPORATED
RESET
1275 Danner Dr Aurora, OH 44202
www.networktechinc.com
CONSOLE
Tel:330-562-7070 Fax:330-562-1999
2-wire cable (up to 100 ft (y))
water sensor
Cat5 cable
cable (up to 1000 ft (x))
(up to 1000 ft)
RJ45 SENSORS
ETHERNET 2ETHERNET 1
RJ45-male connector
9
NTI SERIMUX SERIES SSH CONSOLE SWITCH
INITIAL STARTUP
The following instruction will enable the user to quickly make port connections using a terminal connected to the “CONSOLE” port. For instruction to make quick connection using the Ethernet port and Web Interface, see page 43.
1. Make sure the SERIMUX is turned OFF.
2. Using the serial console device connected to the port labeled "CONSOLE", start the terminal program (e.g. Windows HyperTerminal) and configure it as follows:
direct connection (using the appropriate CPU local serial Com port)
115200 bps
8 bits
no parity
1 stop bit
no flow control
ANSI or VT100 terminal mode.
3. Power ON the SERIMUX. Wait for the SERIMUX login prompt.
4. At “login as: “ type <root> (all lowercase letters) and press <Enter>.
5. At “password” type <nti> (all lowercase letters) and press <Enter>.
6. A shell prompt will be displayed -sh-2.05b#
To access the configuration menu:
Type <serimuxconfig> to open Serimux Secure Configuration Menu. (See Figure 8) Use menu structure to configure SERIMUX.
-OR-
To make a connection with a host:
Type <portmenu> to open a port connection menu. Then type a port number and press <Enter> to make a connection with a host. (See Figure 9)
Figure 8- SERIMUX Secure configuration menu via serial connection
10
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Figure 9- Serimux Secure Port Connect menu
Note: To connect to a host, the host must first be configured with the same communication settings as the port (default serial settings = 9600 baud, 8 bits, no parity, 1 stop bit, no flow control). If needed, see “Serial Settings” on page 16 to change the SERIMUX port serial settings.
Connect Direct to Serial Port from Command Line
To connect directly to a serial port from the command line, the SERIMUX must first be connected to the Ethernet (page 7).
Connect Via Telnet
To open a telnet session to a serial port
telnet <Serimux-S hostname or IP address> <TCP port number>
<Serimux-S hostname> is the hostname configured in the workstation where the telnet client will run (through /etc/hosts or DNS table). It can also be just the IP address of the SERIMUX.
<TCP port number> is the number assigned to the serial port. From the factory, 7001 corresponds to serial port 1, 7002 to serial port 2 and so forth.
The user will be prompted for username and password to connect to the port/device (unless the device has no security).
Connect Via SSH
To open an SSH session to a serial port
ssh -l <Username> <Serimux-S hostname or IP address> -p <Tcp port number>
<Username> is the user configured to access that serial port (as defined in the list of users in the device
<Serimux-S hostname> is the hostname configured in the workstation where the telnet client will run (through /etc/hosts or DNS table). It can also be just the IP address of the SERIMUX.
<TCP port number> is the number assigned to the serial port. From the factory, 7001 corresponds to serial port 1, 7002 to serial port 2 and so forth.
The user will be prompted for a password to connect to the port/ host.
, Issue the following command from the command line:
, issue the following command from the command line:
configuration).
11
NTI SERIMUX SERIES SSH CONSOLE SWITCH
USING THE SERIMUX CONSOLE SWITCH
The SERIMUX Console Switch is controlled using
Serial Control- from a "dumb" terminal- locally-connected
- through an external modem from a remote location
- through a CPU connected to a “User” port
Ethernet Connection (through a LAN or the Internet)
- using the Web Interface
- using Telnet or SSH client
Serial Control
The SERIMUX Console Switch can be easily configured using serial communications from either a locally-connected “dumb” terminal, from a terminal remotely connected through a modem, or from a CPU connected to a port configured as a “User” port. Using a keyboard-controlled menu, the user can make port connections or modify various parameters and options for each port.
Ethernet Connection
With an Ethernet connection to a LAN, the user can remotely control SERIMUX port configuration and connections. A user can connect through the Web Interface menus (see page 43) or using a Telnet or SSH client.
SERIAL CONTROL- ADMINISTRATOR
Using serial control, the SERIMUX supports 2 operator levels, administrator and user, each with separate password protection for security.
The administrator logs in using an administrator password
administrator name : root (all lowercase letters) administrator password : nti (all lowercase letters)
FYI: Users may be granted administrative access rights by any user with administrative access rights.
The administrator and any user with administrative rights can:
Users with only “user” rights can only connect to host ports they have access to as defined by the root user or a user with administrative access rights.
Throughout the SERIMUX Secure Configuration menu, the following guidelines apply:
Once changes are made, at the “INPUT” prompt;
If you press <x>-<Enter> without saving first, the message “Do you want to save and apply configuration (y/n):” will appear. Press <y> to save and apply, press <n> to exit without saving. If you press <n> or anything but <y>, you will receive the message “Nothing applied”.
If you press <x>-<Enter> without having made any changes, the message “Do you want to exit configuration menu(y/n):” will appear. Press <y> to exit, or press <n> to be returned to the menu at which you were last. Pressing any other key will cause the message “INVALID INPUT” and return you to the current menu.
Press <h>-<Enter> for topic specific help.
Users login using a password set by the administrator or a user with administrative privileges.
view / modify port parameters;
view / modify user parameters and user access rights to ports;
disconnect ports, logout users etc.
connect to devices on all host ports
fully configure the SERIMUX except change the “root” password (only the “root” user can change the “root”
password)
- press <s>-<Enter> to save them for application to the system on the next reboot
- press <p>-<Enter> to save and apply changes immediately
- press <Esc> to exit the menu and step back one menu
- press <x>-<Enter> to exit the SERIMUX Secure configuration menu
The administrator name cannot be changed.
To change the administrator password, see page 28.
12
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Login as the administrator
1. From the user terminal connected to the “Console” port, open the terminal program (configured as described on page 10 under "Initial Startup").
2. Power ON the SERIMUX. Wait for the SERIMUX login prompt.
3. At “login as: “ type <
4. At “password” type <
Note: This will only access the SERIMUX if the administrator password has not yet been changed from "nti".
Note: If the administrator password has been changed and is not known, contact NTI for instruction on resetting the SERIMUX to the default password “nti”.
5. A shell prompt will be displayed -sh-2.05b#
To access the configuration menu:
Type <serimuxconfig> to open Serimux Secure Configuration Menu. (See Figure 8) Use the menus as described on the following pages to configure the SERIMUX.
Figure 10- Serimux Secure Configuration menu
FYI: Only a user with administrative rights can access the configuration menu. Otherwise, a user will login directly to the Port Connect menu (Figure 9, page 11), with access to ports as defined by the administrator.
From the Serimux Secure Configuration menu, the following options are possible
Function Description Keystroke
Port Management Configure port settings <1>-<Enter> Network Management Configure Network settings <2>-<Enter> Administration Settings Configure unit name, “root” password, security, and perform firmware update <3>-<Enter> User Management Add, delete, and configure user settings; add, delete, setup access groups <4>-<Enter> Administrative Info View syslog, firmware version, MAC addresses, network information <5>-<Enter> Exit Exit connection with SERIMUX <x>-<Enter>
From any submenu, press <Esc> to exit and back out to the previous menu. Press <x>-<Enter> to exit configuration menu.
root> (all lowercase letters) and press <Enter>. A prompt requesting a password will appear.
nti> (all lowercase letters) and press <Enter>.
:
13
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Port Management
From the Configuration menu, press <1> to open the “Port Management” menu.
Figure 11- Port Management- complete ports list
All ports, whether devices are connected to them or not, are listed in the Port Management menu. To make changes to a specific port’s configuration, enter the port number and press <Enter>. A menu of Port Management settings will appear.
Figure 12- Port Management selections for Port 1
To choose a category of settings to change, enter the number of the selection and press <Enter>.
14
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Common Settings
Before making changes to settings for specific ports, it would be quicker to apply settings to the “common” port, by pressing <o> from the Port Management menu. This will open a menu (below) where the settings most common to the greatest number of ports can be configured. With these configured, changing port settings for specific ports will be quicker by making the selection of menu item 9-“Apply Common Settings” in the Port Management menu (page 22).
Figure 13- Port Management- configure common settings for most ports
Port Settings
From the Port Management menu, with Port x (any port) selected, press <1>-<Enter> to open the Port Setting menu.
Tip: Before configuring settings for Port 1-xx, configure common settings (top of page) and consider if applying them to the selected port will save time (see also page 22).
Figure 14- Port Management- port settings for Port 1
15
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Setting Valid Entries
Port Name the name as it will appear in the port list- max. 50 characters. Port Enable Enable or Disable. If disabled, no user can connect to it. Port Type Host : for device connection
User: for direct user connection Dial-in User: for connection via modem
Assign IP Enable When enabled, an IP address can be specifically assigned to this
port. Once enabled, the menu will refresh and an additional line will be added to assign the IP address to be used.
TCP Port No. Assign number used for TCP communication
Be careful not to assign the same number used by another port, or the second port with a duplicate TCP port assignment will not work.
Connection Protocol Select Telnet for non-secure connection, or SSH to require secure
connections only
Timeout (minutes) set time (in minutes) before a port connection that is idle will be
automatically disconnected- range 0-999 minutes (0= disable) Port Escape Seq. Enable Enable or disable the function of using a port escape sequence Port Escape Sequence
Break Sequence Sequence of characters which will send a break signal –
Break Duration (msec.) Duration for which the break signal will be applied-range=0-999
Press <Esc> to exit and back out to the previous menu.
Keyboard key to use in conjunction with the <Ctrl> key for a port
escape sequence. The default is <z>.
ie. <Ctrl>-<break>
Serial Settings
From the Port Management menu, with Port x (any port) selected, press <2>-<Enter> to open the Serial Setting menu.
Figure 15- Port Management-serial settings for Port 1
Setting Value
Baud Rate 50bps-115.2Kbps (default = 9600) Data Bits 5, 6, 7, or 8 (default = 8) Stop bits 1 or 2 (default = 1) Parity None, Even, or Odd (default = none) Flow Control Hardware, Software, Both, or None (default = none) Inter Character Delay 0-999 ms Line Feed Suppress Enable or Disable DTR Option High or Low
16
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Port Logging
From the Port Management menu, with Port x (any port) selected, press <3>-<Enter> to open the “Port Logging” menu. Port logging is used to record data received on the serial port.
Figure 16- Port Management-port logging for Port 1
Only 1 menu item will be displayed, indicating that port logging is disabled. Press <1>-<Enter> to be prompted for a new value. Press <2>-<Enter> to enable port logging.
With port logging enabled, additional menu items will appear with the following setting options:
Setting Value
Log Enable Disable or Enable Logging feature for this port Log Storage Location System Memory (cannot change at this time) Enable Syslog Disable or Enable Syslog feature for port Syslog Location Local Log Buffer Size 0-999 (K bytes) Log File Name up to 100 characters Time Stamp With Log Enable to have log entries include a timestamp
Press <8> to view any current entries in the port log.
Press <9> to delete any entries in the port log for that port.
17
NTI SERIMUX SERIES SSH CONSOLE SWITCH
Modem Setting
From the Port Management menu, with Port x (any port) selected, press <4>-<Enter> to open the “Modem Setting” menu.
Figure 17- Port Management-modem setting for Port 1
If the port is set for a port type “Dial-In User” (see page 15), it will require a modem to be connected. Refer to your modem instructions for appropriate settings to be applied here.
Authentication
From the Port Management menu, with Port x (any port) selected, press <5>-<Enter> to open the ”Authentication” menu.
Figure 18- Port Management-authentication for Port 1
From the menu (showing “1. Authentication Type”), press <1>-<Enter> to open a list of authentication options.
To disable authentication for that port, enter <1> for “none”. If the Authentication Type is set to “none”, then a user will not be required to provide a username and password to access that port when connecting to it.
18
Loading...
+ 58 hidden pages