Net to Net Technologies UIM-E3 Installation Instructions Manual

UIM-E3
E3 Uplink Interface Module
Installation Instructions
CAUTION
Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions when handling this equipment.
Installation
1. Unpack and inspect the equipment.
The following components should be included:
1 UIM-E3 4 #6 Phillips Panhead Internal Locking Screws 2 #6 Phillips Beige Flathead Screws
If there is any visible damage, do not attempt to connect the device. Contact Customer Support at 1­877-638-2638 (001-603-427-0600 for international customers) or Support@NetToNet.com.
2. Verify switch configuration.
Ensure that the DIP switches on the UIM-E3 circuit board are positioned correctly (according to desired configurations) prior to installing the UIM-E3 on a Multiplexer Uplink Module or in a Mini DSLAM. There are two DIP switches located on the top side of the circuit board, opposite the faceplate. Switches are numbered from left to right; Switch #1 (on the left) is not used, Switch #2 (on the right) is configured as follows:
Transmit Line Buildout Switch Configuration
Switch #1 Switch #2 Tx Line Buildout not used down 0-255 ft. not used up 255-450 ft.
220-0000073 rev01
3. Install the UIM-E3.
Required tool for installation: Phillips screwdriver.
UIM-E3 Installation in an IP DSLAM
Affix the UIM-E3 to a Multiplexer Uplink Module (MUM).
NOTE
The UIM-E3 may be attached to a MUM that has already been in service, although you must remove the MUM from the IP DSLAM in order to do so.
Removal of a MUM from an IP DSLAM chassis that is powered up will not affect the operational status of other modules within the chassis; it will, however, disengage the IP DSLAM's upstream network connection.
a. Place the MUM on a flat surface with the circuit board facing up.
b. Select a port on the MUM for UIM-E3 installation; either port (1 or 2) may be used.
Although not required for operational purposes, if redundancy is desired, two UIMs may be installed on the MUM, one in each port.
c. Remove the blanking plate* from the selected port.
d. Carefully slide the faceplate of the UIM-E3 under the lip of the MUM faceplate at
the selected port opening such that the UIM-E3 circuit board is facedown and the UIM-E3 label shows through the port opening with the model name along the right­hand edge.
e. Ensure the mounting holes on the UIM-E3 are lined up with the corresponding
pems on the MUM and the board-to-board connector key pins are properly aligned.
f. Gently press down with even pressure on all four corners of the UIM-E3 until the
board-to-board connector is fully seated.
g. Secure the boards together at the pems with the (4) provided panhead screws.
h. Secure the UIM-E3 faceplate to the MUM faceplate using the (2) provided beige
flathead screws.
CAUTION
Install the MUM in an IP DSLAM chassis.
*Blanking plates should be stored for possible future use. If a UIM-E3 is removed from a MUM, it must be replaced with either another UIM or a blanking plate. DO NOT INSTALL A MUM WITH AN EMPTY UIM PORT INTO AN IP DSLAM.
The IPD12000 is a fourteen slot chassis; slots 1-12 are reserved for Access Modules and slots 13-14 are reserved for Multiplexer Uplink Modules (MUMs). The IPD4000 is a five slot chassis; slots 1-4 are reserved for Access Modules and slot 5 is reserved for a MUM.
220-0000073 rev01
a. Align the MUM with the slot module guides of the chosen slot for installation
(either slot 13 or 14 on the IPD12000 or slot 5 on the IPD4000).
b. Slide the MUM firmly into the chassis. DO NOT USE EXCESS FORCE.
c. Tighten the fastening screws on the MUM faceplate.
d. Verify that the PWR (Power) LED on the MUM faceplate is illuminated.
UIM-E3 Installation in a Mini DSLAM
CAUTION
Disconnect all power sources from the Mini DSLAM before installing the UIM-E3.
a. Remove the (8) screws securing the Mini DSLAM chassis and carefully lift off the chassis
cover. Set the screws aside.
b. Select a port on the Mini DSLAM for UIM-E3 installation; either port (1 or 2) may be used.
Although not required for operational purposes, if redundancy is desired, two UIMs may be installed in the Mini DSLAM, one in each port.
c. Remove the blanking plate* from the selected port.
d. Carefully slide the faceplate of the UIM-E3 under the inside lip of the Mini DSLAM at the
selected port opening such that the UIM-E3 circuit board is facedown and the UIM-E3 label shows through the port opening with the model name along the right-hand edge.
e. Ensure the mounting holes on the UIM-E3 are lined up with the corresponding pems on
the Mini DSLAM board and the board-to-board connector key pins are properly aligned.
f. Gently press down with even pressure on all four corners of the UIM-E3 until the board-
to-board connector is fully seated.
g. Secure the boards together at the pems with the (4) provided panhead screws.
h. Secure the UIM-E3 faceplate to the front of the Mini DSLAM chassis using the (2)
provided beige flathead screws.
i. Replace the Mini DSLAM chassis cover and secure with the original (8) screws.
CAUTION
220-0000073 rev01
*Blanking plates should be stored for possible future use. If a UIM-E3 is removed from a Mini DSLAM, it must be replaced with either another UIM or a blanking plate. DO NOT OPERATE A MINI DSLAM WITH AN EMPTY UIM PORT.
4. Establish the E3 connection.
Plug the E3 Tx and Rx cables into the corresponding E3 connection BNC ports on the UIM-E3 faceplate. Verify the connection; the E3 Lnk LED will pulse (once per second) to indicate the E3 connection is established and operational.
NOTE
An E3 Uplink Interface Module (UIM-E3) must be connected via E3 line to an E3 network extender provider unit (ENE3400-P or ENE3400-P-6-AC/DC). A UIM-E3 connected to an E3 network extender subscriber unit will not function.
Additional Information
LED Indicators
LED State Indication Additional Information
Lnk flashing
green solid green E3 link is established A connection exists but there is indication of a problem with the E3
no illumination
Alm no
illumination solid amber Remote Alarm Indication
pulsing amber
E3 is operational The E3 connection has been established and traffic is flowing.
Loss of Synchronization (LOS)
E3 is operational Note: If the E3 Lnk LED also remains unlit then the UIM-E3 has
(RAI) Alarm Indication Signal
(AIS)
line. The incoming connection to the UIM-E3 has been lost; no data is
being received.
LOS. The outgoing connection from the UIM-E3 has been lost; no data
is being transmitted. An indirect connection has been lost; the UIM-E3 may no longer
be receiving data.
(A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid, less constant rate.)
220-0000073 rev01
Regulatory Compliance
The following regulatory compliance information applies to the UIM-E3 as installed in a Mini DSLAM chassis or as affixed to a MUM installed in an IP DSLAM chassis.
European Regulatory Compliance Information for Class A Equipment
This Class A product complies with European Norm EN55022.
Warning: In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures to correct the situation.
220-0000073 rev01 © Copyright 2001 Net to Net Technologies, Inc. ™ The Net to Net Logo is a trademark of Net to Net Technologies, Inc.
Worldwide Headquarters
Net to Net Technologies 112 Corporate Drive, Suite 1 Portsmouth, NH 03801 USA +1 877-638-2638
220-0000073 rev01
http://www.NetToNet.com/
Contact@NetToNet.com
EMEA Headquarters
Net to Net Technologies
Victoria House 19 Park Way
Newbury Berkshire RG14 1EE
UK
+44 (0) 1635 570950
Loading...