If there is any visible damage, do not attempt to connect the device. Contact Customer Support at 1877-638-2638 (001-603-427-0600 for international customers) or Support@NetToNet.com.
2. Verify switch configuration.
Ensure that the DIP switches on the UIM-E1 circuit board are positioned correctly (according to
desired configurations) prior to installing the UIM-E1 on a Multiplexer Uplink Module or in a Mini
DSLAM. There are eight DIP switches located on the top side of the circuit board, opposite the
faceplate. Switches are numbered from left to right, starting with Switch #1 on the left and ending
with Switch #8 on the right. Switches 1-2 and 5-8 are not used. Configuration for switches #3 and
#4 are as follows:
Frame Type & Line Coding
Switch Configuration
Switch #3 Frame Type Switch #4 Line Coding
downCRCdownHDB3
upno CRCupAMI
CRC = Cyclic Redundancy Check
HDB3 = High Density Bipolar 3
AMI = Alternate Mark Inversion
220-0000071 rev01
3. Install the UIM-E1.
Required tool for installation: Phillips screwdriver.
UIM-E1 Installation in an IP DSLAM
Affix the UIM-E1 to a Multiplexer Uplink Module (MUM).
NOTE
The UIM-E1 may be attached to a MUM that has already been in service, although you must
remove the MUM from the IP DSLAM in order to do so.
Removal of a MUM from an IP DSLAM chassis that is powered up will not
affect the operational status of other modules within the chassis;
it will, however, disengage the IP DSLAM's upstream network connection.
a. Place the MUM on a flat surface with the circuit board facing up.
b. Select a port on the MUM for UIM-E1 installation; either port (1 or 2) may be used.
Although not required for operational purposes, if redundancy is desired, two UIMs
may be installed on the MUM, one in each port.
c. Remove the blanking plate* from the selected port.
d. Carefully slide the faceplate of the UIM-E1 under the lip of the MUM faceplate at
the selected port opening such that the UIM-E1 circuit board is facedown and the
UIM-E1 label shows through the port opening with the model name along the righthand edge.
e. Ensure the mounting holes on the UIM-E1 are lined up with the corresponding
pems on the MUM and the board-to-board connector key pins are properly aligned.
f. Gently press down with even pressure on all four corners of the UIM-E1 until the
board-to-board connector is fully seated.
g. Secure the boards together at the pems with the (4) provided panhead screws.
h. Secure the UIM-E1 faceplate to the MUM faceplate using the (2) provided beige
flathead screws.
CAUTION
Install the MUM in an IP DSLAM chassis.
*Blanking plates should be stored for possible future use. If a UIM-E1 is removed from a
MUM, it must be replaced with either another UIM or a blanking plate. DO NOT INSTALL A
MUM WITH AN EMPTY UIM PORT INTO AN IP DSLAM.
The IPD12000 is a fourteen slot chassis; slots 1-12 are reserved for Access Modules
and slots 13-14 are reserved for Multiplexer Uplink Modules (MUMs). The IPD4000 is a
five slot chassis; slots 1-4 are reserved for Access Modules and slot 5 is reserved for a
MUM.
220-0000071 rev01
a. Align the MUM with the slot module guides of the chosen slot for installation
(either slot 13 or 14 on the IPD12000 or slot 5 on the IPD4000).
b. Slide the MUM firmly into the chassis. DO NOT USE EXCESS FORCE.
c. Tighten the fastening screws on the MUM faceplate.
d. Verify that the PWR (Power) LED on the MUM faceplate is illuminated.
UIM-E1 Installation in a Mini DSLAM
CAUTION
Disconnect all power sources from the Mini DSLAM before installing the UIM-E1.
a. Remove the (8) screws securing the Mini DSLAM chassis and carefully lift off the chassis
cover. Set the screws aside.
b. Select a port on the Mini DSLAM for UIM-E1 installation; either port (1 or 2) may be used.
Although not required for operational purposes, if redundancy is desired, two UIMs may
be installed in the Mini DSLAM, one in each port.
c. Remove the blanking plate* from the selected port.
d. Carefully slide the faceplate of the UIM-E1 under the inside lip of the Mini DSLAM at the
selected port opening such that the UIM-E1 circuit board is facedown and the UIM-E1
label shows through the port opening with the model name along the right-hand edge.
e. Ensure the mounting holes on the UIM-E1 are lined up with the corresponding pems on
the Mini DSLAM board and the board-to-board connector key pins are properly aligned.
f. Gently press down with even pressure on all four corners of the UIM-E1 until the board-
to-board connector is fully seated.
g. Secure the boards together at the pems with the (4) provided panhead screws.
h. Secure the UIM-E1 faceplate to the front of the Mini DSLAM chassis using the (2)
provided beige flathead screws.
i. Replace the Mini DSLAM chassis cover and secure with the original (8) screws.
CAUTION
220-0000071 rev01
*Blanking plates should be stored for possible future use. If a UIM-E1 is removed from a Mini
DSLAM, it must be replaced with either another UIM or a blanking plate. DO NOT OPERATE A MINI
DSLAM WITH AN EMPTY UIM PORT.
4. Connect the E1 Line.
Plug the E1 cable into the E1 RJ45 port on the UIM-E1 faceplate. Verify the connection; the E1 Lnk
LED will pulse (once per second) to indicate the E1 connection is established and operational.
NOTE
E1 RJ45 Port Pinout
Pin 1 Rx RingPin 5 Tx Tip
Pin 2 Rx TipPin 6 not used
Pin 3 not used Pin 7 not used
Pin 4 Tx RingPin 8 not used
An E1 Uplink Interface Module (UIM-E1) must be connected via E1 line to an E1 network extender
provider unit (ENE2000-P or ENE2000-P-12-AC/DC). A UIM-E1 connected to an E1 network extender
subscriber unit (ENE2000-S) will not function.
Additional Information
LED Indicators
LED StateIndicationAdditional Information
Lnk flashing
green
solid greenE1 is operationalA connection exists but there is indication of a problem with the E1
no
illumination
E1 is operationalThe E1 connection has been established and traffic is flowing.
Loss of Synchronization
(LOS)
If you are using a shielded E1 cable
for your Network connection, it must
be grounded through Pins 3, 6, 7 & 8.
line.
The incoming connection to the UIM-E1 has been lost; no data is
being received.
Alm no
illumination
solid amberRemote Alarm Indication
pulsing
amber
E1 is operationalNote: If the E1 Lnk LED also remains unlit then the UIM-E1 has
(RAI)
Alarm Indication Signal
(AIS)
(A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more rapid,
less constant rate.)
Regulatory Compliance
The following regulatory compliance information applies to the UIM-E1 as installed in a Mini DSLAM
chassis or as affixed to a MUM installed in an IP DSLAM chassis.
220-0000071 rev01
LOS.
The outgoing connection from the UIM-E1 has been lost; no data
is being transmitted.
An indirect connection has been lost; the UIM-E1 may no longer
be receiving data.
European Regulatory Compliance Information for Class A Equipment
This Class A product complies with European Norm EN55022.
Warning: In a domestic environment this product may cause radio interference in which case
the user may be required to take adequate measures to correct the situation.