Net to Net Technologies strongly recommends the use of proper electrostatic discharge (ESD) precautions
when handling this equipment.
INSTALLATION
1. Unpack and inspect the SAM1000-12.
If there is visible damage, do not attempt to connect the device; contact Customer Support at 1877-638-2638 (1-603-427-0600 for international customers) or Support@NetToNet.com.
2. Install the SAM1000-12 in an IP DSLAM chassis.
NOTE
All Access Multiplexer Modules for Net to Net Technologies' IP DSLAMs are hot swappable;
installing or removing an Access Module while the chassis is powered up does not affect the
operational status of other Access Modules within the chassis. The IPD12000 is a fourteen slot
chassis; slots 1-12 are reserved for Access Modules (such as the SAM1000-12) and slots 13-14
are reserved for Multiplexer Uplink Modules (such as the MUM200-2). Access Modules may be
placed in any order in slots 1-12. The IPD4000 is a five slot chassis; slots 1-4 are reserved for
Access Modules and slot 5 is reserved for a Multiplexer Uplink Module.
There must be a Multiplexer Uplink Module installed in the IP DSLAM chassis in order for Access Modules to
operate.
a. Align the SAM1000-12 with the slot module guides of the chosen slot for installation (slot
1-12 on the IPD12000 or slot 1-4 on the IPD4000).
b. Slide the SAM1000-12 firmly into the chassis. DO NOT USE EXCESS FORCE.
c. Secure the SAM1000-12 by tightening the fastening screws on the module faceplate.
d. Verify that the PWR (Power) LED on the SAM1000-12 faceplate is illuminated.
210-0000011 rev03
3. Connect the SDSL Line(s).
Plug the SDSL cable into the RJ21 connector for the chosen slot on the back of the IP DSLAM.
For each port being connected to a remote SDSL modem, verify that the SDSL link has been
established; the SDSL LK LED for that port will show steady illumination to indicate the
connection has been made. Link up time can vary from one to five minutes depending on the
quality, gauge and distance of the copper cables. Default bandwidth for the SAM1000-12 is 272
kbps.
Once the SAM1000-12 has been installed, bandwidth and other configurations are software selectable via Net to
Net Technologies' Network Management System (NMS). For further information regarding SAM1000-12
configuration and management please refer to the Management User Guide for IP and Mini DSLAMs.
OVERVIEW
SAM1000-12 Management
Statistical and configuration data for the SAM1000-12 are maintained in an embedded web
server that resides within the firmware of Net to Net Technologies' Multiplexer Uplink Modules
(MUMs). This firmware contains Net to Net's Network Management System (NMS) and Simple
Network Management Protocol (SNMP).
Accessing SAM1000-12 data in a newly installed IP DSLAM
a. Connect your PC to the Ethernet RJ45 MGMT port located on the faceplate of the
MUM installed in your IP DSLAM.
b. Verify the connection; solid illumination of the MGMT LNK LED on the MUM
faceplate indicates the connection has been established.
c. Launch a web browser such as Microsoft Internet Explorer (v4.0 or higher) or
Netscape Navigator (v4.0 or higher).
d. Type the default IP address into the address field at the top of your browser and
press the Enter key.
192.168.254.252 if the MUM is in slot 13 (IPD12000) or slot 5 (IPD4000)
!
192.168.254.253 if the MUM is in slot 14 (IPD12000)
!
210-0000011 rev03
e. Log in with a default username and password (both of which are case sensitive).
Please note that General Users have "read only" access; for NMS configuration you
must log in as a Superuser.
general / Password
!
superuser / Password
!
NOTE
Accessing SAM1000-12 data in a previously installed IP DSLAM
Once accessed initially, the management system within the MUM can be configured such that NMS
and SNMP can be reached from any computer on your network. For further instruction please refer
to the Management User Guide for IP and Mini DSLAMs.
a. Establish a connection with the MUM either directly (through the Ethernet RJ45
MGMT port on the MUM faceplate) or, if the system has been so configured, from a
PC on your network.
b. For direct connections verify that the MGMT LNK LED on the MUM faceplate is
illuminated, indicating the connection has been established.
c. Launch a web browser such as Microsoft Internet Explorer (v4.0 or higher) or
Netscape Navigator (v4.0 or higher).
d. Enter the assigned IP address* into the address field at the top of your browser
window. Press the Enter key.
e. Log in with your assigned username and password.* Please note that General Users
have "read only" access; for NMS configuration you must log in as a Superuser.
*If the IP address, username or password is unknown, contact your System Administrator
or Information Technology Manager.
Default Settings
No configuration is necessary for the SAM1000-12 to operate at default settings. If however, a
change is required, default settings can easily be modified within NMS. For information
regarding specific parameter configurations, refer to the Management User Guide for IP and
Mini DSLAMs.
Management Password Administration Defaults*
General Username: general
General Password: Password
*Usernames and passwords are case sensitive.
210-0000011 rev03
Super Username: superuser
Super Password: Password
Backbone-VLAN: 0
VLAN:0 - 0
Pri [Priority]:0
Flood:Upl [Uplink]
Circuit Configuration
Circuit configurations for the SAM1000-12 are defined in the Management User Guide for IP
and Mini DSLAMs. Default settings may be altered via the Circuit Configuration window of Net
to Net's Network Management System (NMS).
Data Storage
Configuration backup is inherent in the SAM1000-12. Upon initial power up of the IP DSLAM,
the default parameters of the SAM1000-12 will remain in place unless changed through NMS.
Once changed, new configurations will automatically be recorded in the Random Access
Memory (RAM) of the SAM1000-12 and the Non-Volatile Random Access Memory (NVRAM) of
the MUM. While data stored in SAM1000-12 RAM will be erased if the unit loses power, data
stored within MUM NVRAM will remain intact (even if the unit loses power) unless deliberately
cleared or reconfigured.
ADDITIONAL INFORMATION
Speed
There are four bandwidth options for the SDSL link; default is 272 kbps. Distance capabilities
listed below assume the use of 26 American Wire Gauge (AWG) cable; connections made with
cable of a lesser gauge (e.g., 24 AWG) will link up at greater distances. The units may not link
up if the cable distance is greater than a particular bandwidth will support. Remote SDSL
modems determine line speed through their communication with the SAM1000-12.
PWR (Power)solid greenunit is operationalIf the Power LED is not illuminated, it is unlikely the
SAM1000-12 is receiving power and none of the LEDs
will be illuminated.
SDSL LK (Link)pulsing
green
solid greenproblematic SDSL
no
illumination
SDSL RX
(Receiving)
SDSL TX
(Transmitting)
flashing
amber
solid amberheavy Rx trafficThe port is receiving large amounts of data from the
no
illumination
flashing
amber
solid amberheavy Tx trafficThe port is transmitting large amounts of data to the
no
illumination
SDSL connection is
established and active
connection
no SDSL connection
SDSL activityThe port is receiving either data from the remote SDSL
no activityA link may exist but the port is not receiving any data
SDSL activityThe port is transmitting data to the remote SDSL
no activityA link may exist but the port is not transmitting any
The SDSL link is operational and traffic is flowing.
A connection exists but there is indication of a problem
with the SDSL line.
modem or statistical packets from the IP DSLAM
management.
remote SDSL modem.
from the remote SDSL modem.
modem.
remote SDSL modem.
data to the remote SDSL modem.
(A pulsing LED blinks steadily at a rate of once per second. A flashing LED blinks at a more
rapid, less constant rate.)
Regulatory Compliance
FCC Regulatory Compliance Information for Class A Equipment
Note: This equipment has been tested and found to comply with the limits for a Class A
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with the instruction manual, may
210-0000011 rev03
cause harmful interference to radio communications. Operation of this equipment in a
residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Caution: Changes or modifications not expressly approved by the manufacturer could void
the user’s authority to operate the equipment.
Industry Canada Regulatory Compliance Information for Class A Equipment
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la Classe A est conforme à la norme NMB-003 du Canada.
European Regulatory Compliance Information for Class A Equipment
This Class A product complies with European Norm EN55022.
Warning: In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures to correct the situation.