Net Safety Monitoring RM2 Specifications

RM2 Millennium Controller
BCR-0030-00-003
RM2 Millennium
2-channel Rack Mount Controller
The RM2 Millennium’s design provides flexible configuration, simple operation and maintenance, and intelligent functions that will save time and improve your bottomline.
 Calibration/Reset Button Programming, Clearing
Alarms or Calibrations  High Intensity LEDs Indicate Fault and Alarm  RS-232 Serial COM Port Connect a Laptop or PDA
for Setup and Event Logging  Five Jumper Selectable Relays Normally Open or
Closed  Relay Set Points High/Low = Gas
Fire/Fault = Flame  Two 4–20 mA Analog Outputs for Gas and Flame
Detectors  Four Character Scrolling Display – Visible in all
Lighting Conditions  English, Spanish, French Menu Languages Available
Product Data Sheet
July 2012
RM2 Millennium Controller
Features and Benefits
The Millennium RM2 is a 2-channel rack mount controller designed to off er you the ultimate in control and versatility. Create a monitoring system to suit your installation by
combining any of Net Safety’s  ame or gas detection solutions
to a centralized display to cover multiple zones with a single monitoring device.
The RM2’s independent channels eliminate the standard
industry limitation of monitoring only ame or only gas by adding a new level of exibility — combining ame and/or gas
detection into a single monitoring device. And with the RM2’s independent channels, activity on one channel does not affect the other channel so a variety of tasks and activities can be performed without initiating false alarms.
Setup, operate, monitor and maintain the RM2 using the Front Panel Push button, or connect a PC or a PDA via the serial
communications port. The RM2 contains custom designed software and a number of user programmable options to
congure the RM2 to exactly suit your needs in the eld on
demand. Operation and maintenance are simple without
compromising safety or reliability. Specically designed with
end user input, the RM2 shows you what you need to know quickly and easily. Each channel has its own clearly visible display with helpful prompts to guide you through setup and maintenance tasks. Bright LEDs visually indicate warnings and alerts for each input channel and the RM2 circuitry. The Event Logging feature securely stores in protected RAM up to 1000 events automatically listing the date, time, channel, detector type and the associated alarm, fault or calibration event. Highly useful information for developing maintenance schedules or performing troubleshooting and sequence of events analysis.
RM2 Millennium Controller
Product Data Sheet
BCR-0030-00-003
Specifications
Table 1 - RM2 Millennium Controller Ranges
Specifications Analog Relay Digital
Operating Voltage Range 10.5 to 32 Vdc
Power Consumption (at 24 V dc) Nominal 150 mA (1.8 W / 3.0 W ) de-energized / energized maximum 290 mA / 3.48 W
Power Consumption (at 12 V dc)) Nominal 80 mA / 130 mA (1.92 W / 3.12 W) de-energized / energized maximum 160 mA / 3.84 W
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Humidity Range 0 to 100 % RH, non-condensing
Chassis Material 16 gauge steel / powder coated
Weight 2.1 Kg / 4.5 lb (Stainless Steel option 3.4 Kg / 7.5 lb)
Outputs 4 to 20 mA - Into a maximum loop impedance of
Certifications/Approvals CSA - Class I, Division 2, Groups A, B, C and D - Temperature code T6 (Canada only)
Warranty 2 Year Warranty on Electronics
800 Ohms at 32 V dc or 150 Ohms at 10.5 V dc.
Isolated or non-isolated loop supply.
Form C contacts rated 5 Amps at 30 V dc / 250 V ac. Selectable energized / de-energized latching / non-latching, N.O. or N.C. Fault relay xed as
energized, non-latching.
ANSI-UL/ISA - Certied for ordinary location for Canada and US
RS-485 RTU Modbus protocol
Compatibility
The following Net Safety products are compatible with the RM2 Millennium Controller:
J Flame Detectors: IR3S-A, UV/IRS-A, UVS-A , UVS-H2-A, UV/IRS-H2-A J Gas Transmitters: Millennium II Series, Millennium Series, Toxic Series J Gas Sensors: ST Toxic Sensor Series
Figure 1 - Compatible Net Safety Products
ORDERING INFORMATION
RM2-ARD 2-channel rack mount w/ analog, relay and digital RS-
Labelling Options
-CC two combustible detectors
-CF one combustible, one ame detector
-CT one combustible, one toxic detector
-FF two ame detectors
-FT one ame, one toxic detector
-TT two toxic detectors
485 Modbus RTU protocol output
July 2012
Any Millennium II, Millennium, or
Any Millennium II, Millennium, or
Toxic Series Transmitter/Sensor
Toxic Series Transmitter/Sensor
with Analog Output
with Analog Output
ST Sensor Series Any Net Safety
ST Sensor Series
Connect Any Two Devices
Connect Any Two Devices
HEADQUARTERS Emerson Process Management
Flame and Gas Detection
Net Safety Monitoring Inc. 2721 Hopewell Place NE Calgary, Alberta, Canada T1Y 7J7 T + 1 (403) 219 0688 T 1 866 FIREGAS F +1 (403) 219 0694
www.net-safety.com
Any Net Safety
Flame Detector
Flame Detector
with Analog Output
with Analog Output
©2012 Emerson Process Management. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount Analytical and Net Safety Monitoring are marks of Emerson Process Management family of companies. All other marks are the property of their respective owners.
The contents of this publication are presented for information purposes only, and while effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees,
express or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request. We reserve the
right to modify or improve the designs or specications of
our products at any time without notice.
RM2-COM-KIT - Communication Kit CAGE 2/4/8/12/16 - Rack Mount Cages
BFP - Blank Filler Plate
ACCESSORIES
Loading...