RM2 Millennium Controller
BCR-0030-00-003
RM2 Millennium
2-channel Rack Mount Controller
The RM2 Millennium’s design provides flexible
configuration, simple operation and maintenance,
and intelligent functions that will save time and
improve your bottomline.
Calibration/Reset Button Programming, Clearing
Alarms or Calibrations
High Intensity LEDs Indicate Fault and Alarm
RS-232 Serial COM Port Connect a Laptop or PDA
for Setup and Event Logging
Five Jumper Selectable Relays Normally Open or
Closed
Relay Set Points High/Low = Gas
Fire/Fault = Flame
Two 4–20 mA Analog Outputs for Gas and Flame
Detectors
Four Character Scrolling Display – Visible in all
Lighting Conditions
English, Spanish, French Menu Languages Available
Product Data Sheet
July 2012
RM2 Millennium Controller
Features and Benefits
The Millennium RM2 is a 2-channel rack mount controller
designed to off er you the ultimate in control and versatility.
Create a monitoring system to suit your installation by
combining any of Net Safety’s ame or gas detection solutions
to a centralized display to cover multiple zones with a single
monitoring device.
The RM2’s independent channels eliminate the standard
industry limitation of monitoring only ame or only gas by
adding a new level of exibility — combining ame and/or gas
detection into a single monitoring device. And with the RM2’s
independent channels, activity on one channel does not affect
the other channel so a variety of tasks and activities can be
performed without initiating false alarms.
Setup, operate, monitor and maintain the RM2 using the Front
Panel Push button, or connect a PC or a PDA via the serial
communications port. The RM2 contains custom designed
software and a number of user programmable options to
congure the RM2 to exactly suit your needs in the eld on
demand. Operation and maintenance are simple without
compromising safety or reliability. Specically designed with
end user input, the RM2 shows you what you need to know
quickly and easily. Each channel has its own clearly visible
display with helpful prompts to guide you through setup and
maintenance tasks. Bright LEDs visually indicate warnings and
alerts for each input channel and the RM2 circuitry. The Event
Logging feature securely stores in protected RAM up to 1000
events automatically listing the date, time, channel, detector
type and the associated alarm, fault or calibration event. Highly
useful information for developing maintenance schedules or
performing troubleshooting and sequence of events analysis.
RM2 Millennium Controller
Product Data Sheet
BCR-0030-00-003
Specifications
Table 1 - RM2 Millennium Controller Ranges
Specifications Analog Relay Digital
Operating Voltage Range 10.5 to 32 Vdc
Power Consumption (at 24 V dc) Nominal 150 mA (1.8 W / 3.0 W ) de-energized / energized maximum 290 mA / 3.48 W
Power Consumption (at 12 V dc)) Nominal 80 mA / 130 mA (1.92 W / 3.12 W) de-energized / energized maximum 160 mA / 3.84 W
Temperature Range -40 °C to +80 °C (-40 °F to +176 °F)
Humidity Range 0 to 100 % RH, non-condensing
Chassis Material 16 gauge steel / powder coated
Weight 2.1 Kg / 4.5 lb (Stainless Steel option 3.4 Kg / 7.5 lb)
Outputs 4 to 20 mA - Into a maximum loop impedance of
Certifications/Approvals CSA - Class I, Division 2, Groups A, B, C and D - Temperature code T6 (Canada only)
Warranty 2 Year Warranty on Electronics
800 Ohms at 32 V dc or 150 Ohms at 10.5 V dc.
Isolated or non-isolated loop supply.
Form C contacts rated 5 Amps at 30 V dc / 250 V
ac. Selectable energized / de-energized latching
/ non-latching, N.O. or N.C. Fault relay xed as
energized, non-latching.
ANSI-UL/ISA - Certied for ordinary location for Canada and US
RS-485 RTU Modbus protocol
Compatibility
The following Net Safety products are compatible with the RM2 Millennium Controller:
J Flame Detectors: IR3S-A, UV/IRS-A, UVS-A , UVS-H2-A, UV/IRS-H2-A
J Gas Transmitters: Millennium II Series, Millennium Series, Toxic Series
J Gas Sensors: ST Toxic Sensor Series
Figure 1 - Compatible Net Safety Products
ORDERING INFORMATION
RM2-ARD 2-channel rack mount w/ analog, relay and digital RS-
Labelling Options
-CC two combustible detectors
-CF one combustible, one ame detector
-CT one combustible, one toxic detector
-FF two ame detectors
-FT one ame, one toxic detector
-TT two toxic detectors
485 Modbus RTU protocol output
July 2012
Any Millennium II, Millennium, or
Any Millennium II, Millennium, or
Toxic Series Transmitter/Sensor
Toxic Series Transmitter/Sensor
with Analog Output
with Analog Output
ST Sensor Series Any Net Safety
ST Sensor Series
Connect Any Two Devices
Connect Any Two Devices
HEADQUARTERS
Emerson Process Management
Flame and Gas Detection
Net Safety Monitoring Inc.
2721 Hopewell Place NE
Calgary, Alberta, Canada T1Y 7J7
T + 1 (403) 219 0688
T 1 866 FIREGAS
F +1 (403) 219 0694
www.net-safety.com
Any Net Safety
Flame Detector
Flame Detector
with Analog Output
with Analog Output
©2012 Emerson Process Management. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount Analytical and
Net Safety Monitoring are marks of Emerson Process Management family of companies. All other
marks are the property of their respective owners.
The contents of this publication are presented for information purposes only, and while effort has
been made to ensure their accuracy, they are not to be construed as warranties or guarantees,
express or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request. We reserve the
right to modify or improve the designs or specications of
our products at any time without notice.
RM2-COM-KIT - Communication Kit
CAGE 2/4/8/12/16 - Rack Mount Cages
BFP - Blank Filler Plate
ACCESSORIES