![](/html/7a/7a6b/7a6b7abf9e1ec946ef6c58c239ee9d66f46a363349408224bb75f157a965ff48/bg1.png)
ECO-SENSE Electrochemical H2S
BCR-0039-00-011
ECO-SENSE Electrochemical H2S
2-wire, Loop-powered Gas Detector
The Net Safety Monitoring ECO-SENSE detector
is an innovative H
designed
specifically for 2-wire, loop-powered
installations. An economic and ecological choice,
this extremely versatile detector functions at
less than 0.75 watts of power with 10–30 V dc
and a full LCD display with LED indicators.
Low power gas sensor functions in a 2-wire
4–20 mA sink mode
Allows "one man" sensor calibration in hazardous
areas without area declassification. No electric
devices needed
LCD readout and front panel alarm LED indicators
for Alarm 1, Alarm 2, Fault, and IN CAL are standard
Security mode allows locking of critical parameter
CSA/ANSI/ATEX certifications
Standard "Fault Supervision" circuitry continuously
monitors for failed sensor
S gas detection package
2
Field replaceable H2S sensor module - range
configured on sensor module
4–20 mA signal may be transmitted thousands of
feet on 2-wires
Product Data Sheet
July 2012
ECO-SENSE H2S
Features and Benefits
This advanced sensor interface includes a real time clock
and calendar which is used for logging events such as sensor
replacement, alarms and calibrations. Calibration offset and
gain factors may be viewed for accurately predicting sensor
"end of life" conditions.
Operator interface is through a menu driven magnetic keypad
allowing full access without opening the enclosure. There
are no potentiometers and all adjustments are performed
through the keypad. Calibration magnet is included for nonintrusive calibration, no other special electronic devices are
needed. Users can also program warm up and calibration exit
delays to avoid false alarms. Delay hold outputs at zero until
sensor signals stabilize. IN/OUT alarm trip delays may also be
programmed.
The Net Safety ECO-SENSE H
immunity problems associated with electrochemical sensors
by enclosing all low level signals within a grounded sensor head
available in aluminum and stainless steel. An integral "transient
voltage suppressor" protects the device in case of lightning or
other surge voltage levels. The sensor is enclosed in a rugged
Class 1, Div 1 enclosure suitable for hazardous environment
installations and has been certied by CSA, ANSI and ATEX.
S sensor overcomes noise
2
![](/html/7a/7a6b/7a6b7abf9e1ec946ef6c58c239ee9d66f46a363349408224bb75f157a965ff48/bg2.png)
ECO-SENSE Electrochemical H2S
BCR-0039-00-011
Specifications
Table 1 - ECO-SENSE Electrochemical H2S
Product Data Sheet
July 2012
Controller Specifications
Outputs Low-powered, Analog 2-Wire 4–20 mA current sink output
Electrical
Power Supply 10–30 Vdc at less than .75 Watts
Environmental
Temperature -30 °C to +50 °C (-22 °F to + 122 °F) Ambient Range
Enclosure
Metallurgy 316 Stainless Steel
Conduit Opening
Mounting Surface Mount / 2" Pipe Mount
Certification CSA ANSI-UL/ISA ATEX
Warranty 2 Years
@ nominal 24 Vdc 2-Wire max loop R is 500 ohms
64 x 128 pixel LCD displays 30 minute trend, bar-graph
and large engineering units and LED indicators
3
/
'' NPT (3X)
4
Ex/AEx/EEx/ d IIB + H2 T5
Class I, Division 1& 2 - Groups B, C and D T5
NEMA 4X, IP67
ST490 Sensor Specifications
Sensor Module Electrochemical type sensor with range conguration
Certifications CSA ANSI-UL/ISA ATEX
Response Times T20 < 10 secs T50 < 30 secs
Accuracy
Range 0–100 PPM
Temperature -30 °C to +50 °C (-22 °F to + 122 °F) Ambient Range
Temperature
Drift
Housing Aluminum and 316 Stainless Steel enclosure available
Warranty 2 Years
resistor and shorting transistor integrated into sensor
module
Ex/AEx/EEx/ d IIB + H2 T4
Class I, Division 1& 2 - Groups B, C and D T4
NEMA 4X, IP64
±5 % of full scale ±
< .1 % per °C over ambient temperature range
1 count
ORDERING INFORMATION
Transmitters and ST490 H2S Sensor
ECO-A-S Single Channel-Analog-Stainless Steel
ECO-A-A Single Channel-Analog-Aluminum
HEADQUARTERS
Emerson Process Management
Flame and Gas Detection
Net Safety Monitoring Inc.
2721 Hopewell Place NE
Calgary, Alberta, Canada T1Y 7J7
T + 1 (403) 219 0688
T 1 866 FIREGAS
F +1 (403) 219 0694
www.net-safety.com
©2012 Emerson Process Management. All rights reserved.
The Emerson logo is a trademark and service mark of Emerson Electric Co. Rosemount Analytical and
Net Safety Monitoring are marks of Emerson Process Management family of companies. All other
marks are the property of their respective owners.
The contents of this publication are presented for information purposes only, and while effort has
been made to ensure their accuracy, they are not to be construed as warranties or guarantees,
express or implied, regarding the products or services described herein or their use or applicability.
All sales are governed by our terms and conditions, which are available on request. We reserve the
right to modify or improve the designs or specications of our products at any time without notice.