Netro RU39G-00 Power Output rating

AirStar System Specifications
39 GHz (FCC)
Radio Performance Specifications
Netro's radios are based on a highly integrated design including antenna, millimeter wave, and channelization subsystems in a single low cost, compact outdoor unit.
Antenna Specifications
Polarization Options Vertical and Horizontal
90°, 30°
Additional sectors or high gain options
Radio Performance Specifications
Frequency Range: 38.6 to 40 GHz T/R Spacing: 700 MHz Tuning Range: 350 MHz Tuning Step Size: 1.25 MHz Channel Bandwidth: 12.5 MHz Transmit Power Control Dynamic Range:
47 dB
Air Interface
Netro's Industry-Leading CellMAC Air Interface is based on a TDM/TDMA multiple access system providing native ATM transport to support multiservice applications. Netro's Virtual Framer provides QoS based traffic scheduling for CBR services, while Netro's Virtual Shaper provides QoS based scheduling for VBR services.
Modulation Format 4/16QAM Forward Error Correction BCH System Gain 159 dB Capacity per Channel 12.96/25.92 Mbps Range and Availability,
-6
10
CLR
Base Station Specifications
Capacity per Shelf 155 Mbps Network Interface Options E3, DS3, OC-3c/STM-1 ATM UNI Common Equipment Redundancy 1:1 Modem and Radio Redundancy 1:N
2.1 km, ITU-R Region K, 99.997% Availability
Subscriber Terminal Specifications
Service Interworking Function Physical Interface
T1/E1 ATM AAL1 UDT G.703 Fractional T1/E1 ATM AAL1 SDT with CAS Activity Detection G.703, X.21, V.35 ISDN PRI AAL1 SDT with Bearer Channel Activity Detection I.431 Frame Relay FRF.5, FRF.8 G.703, X.21, V.35 Internet Access RFC 1483: Routed & Bridged 10BaseT / 100BaseT
5/10/00 1
© 2000 Netro Corporation. All rights reserved
Network Management
Element Management
Embedded Management Interface Element Management Systems
SNMP
Link Explorer, PC-based Link Navigator, CORBA/Java Client-Server
North Bound Interfaces
Management Interface CORBA Service Activation Link Provisioner Fault Management Link Inspector Performance Monitoring Link Monitor Billing Statistics Link Collector
Environmental and Mechanical
Operating Environment
Operating Temperature Indoor Equipment Outdoor Equipment
Relative Humidity (Indoor): 5-95%, non-condensing Altitude (System): 0 – 4500 m Wind Loading: Operational Survival
0°C to +40°C
-35°C to +55°C
145 Km/hr 200 Km/hr
Mechanical
Subscriber Terminal H x W x D Weight
- Indoor unit (SAS) 4.4 cm x 21.5 cm x 28.0 cm 2.5 kg
- Outdoor unit (SRU) 30 cm x 16 cm x 20 cm 6.0 kg
Base Station: H x W x D Weight
- Indoor unit 44.4 cm x 48.3 cm x 50.8 cm 21.5 kg
- Outdoor unit (BRU) 41 cm x 11 cm x 17 cm 6.0 kg
Standards and Regulatory Compliance
System: FCC Order 97-391 EMC: FCC Part 15 Class B, Part 101 Traffic Interface: ITU-T G.703, G.704, G.824, ANSI T1.102, T1.403 Mechanical and Safety: UL 1459 & 1950, EN 60950, EN 41003 Environmental BellCORE GR-1089-CORE