By using a Net Optics Tap you agree to the terms and conditions of usage set forth by Net Optics, Inc.
No licenses, express or implied, are granted with respect to any of the technology described in this
manual. Net Optics retains all intellectual property rights associated with the technology described in
this manual. This manual is intended to assist with installing Net Optics products into your network.
Net Optics, Inc. reserves the right to make changes in specications and other information contained
in this document without prior notice. Every effort has been made to ensure that the information in this
document is accurate.
Introduction
Net Optics GigaBit SX/LX to TX Tap simplies connecting GigaBit copper
monitoring and security devices to SX or LX ber network links. Convert SX
or LX to TX and tap into the link with one device, reducing cost and complexity at the same time. GigaBit SX/LX to TX Taps support passive monitoring
of GigaBit links at 1000 Mbps.
Transparent Access
GigaBit SX/LX to TX Taps establish permanent passive access ports without
introducing a point of failure or disturbing other network connections. These
passive Taps deliver full-duplex monitoring with zero impact on network
trafc around the clock.
Security and Visibility
Without an IP address, monitoring devices are isolated from the network,
dramatically reducing their exposure to attacks. However, the monitoring
device connected to the Tap still sees all full-duplex trafc as if it were in-line,
including Layer 1 and Layer 2 errors.
Simply Plug It In
Full-duplex monitoring is a snap with supplied cables. All network and
monitoring cables necessary for plug-and-play deployment are included with
the Tap.
GigaBit SX/LX to TX Tap
Reliability
For extra uptime protection, Net Optics GigaBit SX/LX to TX Taps offer
redundant power connections. Should the primary power source fail, the Tap
automatically switches to the backup power source. Power LEDs on the front
of the Tap indicate the current power source – even if power is lost and
reapplied, there is always zero delay to network trafc.
1
Key Features
Passive, Secure Technology
• Provides passive access at 1000 Mbps without data stream interference or
introducing a point of failure
• Access SX or LX links with GigaBit copper devices without a separate
converter
• Permanent in-line installation without affecting network performance
• Passes all full-duplex trafc (including errors) from all layers for
comprehensive troubleshooting
• No IP address is needed for the Tap or monitoring device, enhancing
monitoring security
• Redundant power ensures monitoring uptime
• Fully IEEE 802.3 compliant
• Fully RoHS compliant
Ease of Use
• LED indicators show redundant power and link status
• Front-mounted connectors make installation and operation quick and easy
• All networking and monitoring cables are included
• Silk-screened application diagram illustrates all connections for easy
deployment
• Optional 19-inch rack frames hold up to 3 or 12 Taps
• Tested and compatible with all major manufacturers’ monitoring devices,
including protocol analyzers, probes, and intrusion detection/prevention
systems
Support
• Net Optics offers free technical support throughout the lifetime of your
purchase. Our technical support team is available from 8 am to 5 pm Pacic
Time, Monday through Friday at +1 (408) 737-7777 and via email at
ts-support@netoptics.com. FAQs are also available on Net Optics website
at www.netoptics.com.
GigaBit SX/LX to TX Tap
2
About This Guide
Please read the guide before attempting to install GigaBit Tap. This guide
covers the following models:
Part NumberDescription
CVT-SXn*/GCU GigaBit SX to TX Tap
CVT-LXn*/GCUGigaBit LX to TX Tap
* “n” is the split ratio where 5 is 50/50, 4 is 60/40, and 3 is 70/30.
Unpacking and Inspection
Carefully unpack the GigaBit Tap and check for damaged or missing parts.
The Fiber Tap ships with the following:
• GigaBit Tap
• 2 Network cables
• 2 Monitor cable
• Test report
• Installation Guide
• Fasteners for rack mounting
You may have also ordered a panel for rack mounting and an extended warranty. Carefully check the packing slip against parts received. If any part is
missing or damaged, contact Net Optics' Customer Service immediately.
GigaBit SX/LX to TX Tap
3
GigaBit SX/LX to TX Tap
Product Diagrams
Network A and B Ports
SX
Network
www.netoptics.com
Figure 1: CVT-SX/GCU Front Panel
www.netoptics.com
Figure 2: CVT-LX/GCU Front Panel
AB
Network A and B Ports
LX
Network
AB
LINK
ACT
LINK
ACT
A B
A B
Monitor A and B Ports
TX
AB
Monitor
ACT LINKACT LINK
Monitor A and B Ports
TX
AB
Monitor
ACT LINKACT LINK
LED
Indicators
Converter Tap
Converter Tap
2
1
LED
Indicators
Converter Tap
Converter Tap
2
1
GigaBit
GigaBit
LASER
CAUTION!
GigaBit
GigaBit
LASER
CAUTION!
Figure 3: Rear Panel AC Power Model
- +- +
Figure 4: Rear Panel DC Power Model
4
LED Indicators
• PWR 1/ PWR 2: Main and Redundant Power. If the Tap is deployed with
both power supplies, both LEDs illuminate when the Tap is plugged in. If
an LED is off, this indicates that the corresponding power supply is not
functioning.
• Link/Activity Indicators: If a good link is established, the LED illu-
minates a steady green. If there is current activity on this link, the LED
ashes.
GigaBit SX/LX to TX Tap
5
GigaBit SX/LX to TX Tap
Connecting to the Network
1. Connect Network Port A to the appropriate network device using a Duplex
LC cable.
2. Connect Network Port B to the appropriate network device using a Duplex
LC cable.
3. Verify that the Tap Network Ports are cabled in-line between two devices.
Transceivers: Class I, eye-safe, laser emitter type. These Class I Lasers
conform to the applicable requirements per US 21 CFR (J) and
EN 60825-1, also UL 1950 applications.
Split Ratio: 50/50
Multimode:
Cable Type: Multimode Corning 50 or 62.5/125µm, wavelength 850nm
Insertion Loss: ≤ 4.5 dB
Optical Transmitter Wavelength: 850 nm nominal
Output Power: -9.5 dB min, -4 dB max
Optical Receiver Input Sensitivity: 0 dB min, -17 dB max
Net Optics offers a limited warranty for all its products. IN NO EVENT SHALL NET OPTICS, INC.
BE LIABLE FOR ANY DAMAGES INCURRED BY THE USE OF THE PRODUCTS (INCLUDING BOTH HARDWARE AND SOFTWARE) DESCRIBED IN THIS MANUAL, OR BY ANY
DEFECT OR INACCURACY IN THIS MANUAL ITSELF. THIS INCLUDES BUT IS NOT LIMITED TO LOST PROFITS, LOST SAVINGS, AND ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT, even if Net
Optics has been advised of the possibility of such damages. Some states do not allow the exclusion
or limitation of implied warranties or liability for incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
Net Optics, Inc. warrants this Tap to be in good working order for a period of ONE YEAR from the
date of purchase from Net Optics or an authorized Net Optics reseller.
Should the unit fail anytime during the said ONE YEAR period, Net Optics will, at its discretion,
repair or replace the product. This warranty is limited to defects in workmanship and materials and
does not cover damage from accident, disaster, misuse, abuse or unauthorized modications.
If you have a problem and require service, please call the number listed at the end of this section and
speak with our technical service personnel. They may provide you with an RMA number, which must
accompany any returned product. Return the product in its original shipping container (or equivalent)
insured and with proof of purchase.
Additional Information
Net Optics, Inc. reserves the right to make changes in specications and other information contained
in this document without prior notice. Every effort has been made to ensure that the information in
this document is accurate. Net Optics is not responsible for typographical errors.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF
ALL OTHERS, EXPRESS OR IMPLIED. No Net Optics reseller, agent, or employee is authorized
to make any modication, extension, or addition to this warranty.
Net Optics is always open to any comments or suggestions you may have about its products and/or
this manual.
Send correspondence to
Net Optics, Inc.
5303 Betsy Ross Drive
Santa Clara, CA 95054 USA
All Rights Reserved. Printed in the U.S.A. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language,
in any form, by any means, without prior written consent of Net Optics, Inc., with the following
exceptions: Any person is authorized to store documentation on a single computer for personal use
only and that the documentation contains Net Optics’ copyright notice.