Net Optics GigaBit SX-LX to TX Tap User Manual

Installation Guide for
GigaBit SX/LX to TX Tap
Doc. PUBCVTSXLXGCUU Rev. 2, 4/07
Contents
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Key Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Product Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Connecting to the Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
GigaBit SX/LX to TX Tap
Connecting to the Monitoring Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Specications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Limitations on Warranty and Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
GigaBit SX/LX to TX Tap
PLEASE READ THESE LEGAL NOTICES CAREFULLY.
By using a Net Optics Tap you agree to the terms and conditions of usage set forth by Net Optics, Inc.
Trademarks and Copyrights
© 2009 by Net Optics, Inc. Net Optics® is a registered trademark of Net Optics, Inc. Additional com­pany and product names may be trademarks or registered trademarks of the individual companies and are respectfully acknowledged.
Additional Information
Net Optics, Inc. reserves the right to make changes in specications and other information contained
in this document without prior notice. Every effort has been made to ensure that the information in this document is accurate.
Introduction
Net Optics GigaBit SX/LX to TX Tap simplies connecting GigaBit copper monitoring and security devices to SX or LX ber network links. Convert SX
or LX to TX and tap into the link with one device, reducing cost and complex­ity at the same time. GigaBit SX/LX to TX Taps support passive monitoring of GigaBit links at 1000 Mbps.
Transparent Access
GigaBit SX/LX to TX Taps establish permanent passive access ports without introducing a point of failure or disturbing other network connections. These passive Taps deliver full-duplex monitoring with zero impact on network
trafc around the clock.
Security and Visibility
Without an IP address, monitoring devices are isolated from the network, dramatically reducing their exposure to attacks. However, the monitoring
device connected to the Tap still sees all full-duplex trafc as if it were in-line,
including Layer 1 and Layer 2 errors.
Simply Plug It In
Full-duplex monitoring is a snap with supplied cables. All network and monitoring cables necessary for plug-and-play deployment are included with the Tap.
GigaBit SX/LX to TX Tap
Reliability
For extra uptime protection, Net Optics GigaBit SX/LX to TX Taps offer redundant power connections. Should the primary power source fail, the Tap automatically switches to the backup power source. Power LEDs on the front of the Tap indicate the current power source – even if power is lost and
reapplied, there is always zero delay to network trafc.
1
Key Features
Passive, Secure Technology
Provides passive access at 1000 Mbps without data stream interference or
introducing a point of failure
Access SX or LX links with GigaBit copper devices without a separate
converter
Permanent in-line installation without affecting network performance
• Passes all full-duplex trafc (including errors) from all layers for
comprehensive troubleshooting
No IP address is needed for the Tap or monitoring device, enhancing
monitoring security
Redundant power ensures monitoring uptime
Fully IEEE 802.3 compliant
Fully RoHS compliant
Ease of Use
LED indicators show redundant power and link status
Front-mounted connectors make installation and operation quick and easy
All networking and monitoring cables are included
Silk-screened application diagram illustrates all connections for easy
deployment
Optional 19-inch rack frames hold up to 3 or 12 Taps
Tested and compatible with all major manufacturers’ monitoring devices,
including protocol analyzers, probes, and intrusion detection/prevention systems
Support
Net Optics offers free technical support throughout the lifetime of your purchase. Our technical support team is available from 8 am to 5 pm Pacic Time, Monday through Friday at +1 (408) 737-7777 and via email at
ts-support@netoptics.com. FAQs are also available on Net Optics website at www.netoptics.com.
GigaBit SX/LX to TX Tap
2
About This Guide
Please read the guide before attempting to install GigaBit Tap. This guide covers the following models:
Part Number Description
CVT-SXn*/GCU GigaBit SX to TX Tap
CVT-LXn*/GCU GigaBit LX to TX Tap
* “n” is the split ratio where 5 is 50/50, 4 is 60/40, and 3 is 70/30.
Unpacking and Inspection
Carefully unpack the GigaBit Tap and check for damaged or missing parts. The Fiber Tap ships with the following:
GigaBit Tap
2 Network cables
2 Monitor cable
Test report
Installation Guide
Fasteners for rack mounting
You may have also ordered a panel for rack mounting and an extended war­ranty. Carefully check the packing slip against parts received. If any part is missing or damaged, contact Net Optics' Customer Service immediately.
GigaBit SX/LX to TX Tap
3
GigaBit SX/LX to TX Tap
Product Diagrams
Network A and B Ports
SX
Network
www.netoptics.com
Figure 1: CVT-SX/GCU Front Panel
www.netoptics.com
Figure 2: CVT-LX/GCU Front Panel
A B
Network A and B Ports
LX
Network
A B
LINK
ACT
LINK
ACT
A B
A B
Monitor A and B Ports
TX
A B
Monitor
ACT LINK ACT LINK
Monitor A and B Ports
TX
A B
Monitor
ACT LINK ACT LINK
LED
Indicators
Converter Tap
Converter Tap
2
1
LED
Indicators
Converter Tap
Converter Tap
2
1
GigaBit
GigaBit
LASER
CAUTION!
GigaBit
GigaBit
LASER
CAUTION!
Figure 3: Rear Panel AC Power Model
- + - +
Figure 4: Rear Panel DC Power Model
4
LED Indicators
• PWR 1/ PWR 2: Main and Redundant Power. If the Tap is deployed with both power supplies, both LEDs illuminate when the Tap is plugged in. If an LED is off, this indicates that the corresponding power supply is not functioning.
• Link/Activity Indicators: If a good link is established, the LED illu- minates a steady green. If there is current activity on this link, the LED
ashes.
GigaBit SX/LX to TX Tap
5
GigaBit SX/LX to TX Tap
Connecting to the Network
1. Connect Network Port A to the appropriate network device using a Duplex
LC cable.
2. Connect Network Port B to the appropriate network device using a Duplex
LC cable.
3. Verify that the Tap Network Ports are cabled in-line between two devices.
Note: ________________________________________________________________
The use of Singlemode (8.5µm) or Multimode (50µm or 62.5µm) cabling is determined by the model purchased.
______________________________________________________________________
A B
www.netoptics.com
Network
A B
LINK
ACT
Monitor
A B
ACT LINK ACT LINK
GigaBit
GigaBit
Converter Tap
Converter Tap
2
1
LASER
CAUTION!
Figure 4: Connecting to the Network
To Network Device, Switch or Router
To Network Device, Switch or Router
6
GigaBit SX/LX to TX Tap
Connecting to the Monitoring Device
1. Supply power to the Tap using the two redundant power supplies included
with the unit. Verify that the Power LED illuminates.
2. Connect Monitor Port A to the appropriate port on the monitoring device
using a CAT5e straight-through cable.
3. Connect Monitor Port B to the appropriate port on the monitoring device
using a CAT5e straight-through cable.
Note: _______________________________________________________________
The second power supply is available to support the ow of trafc to the monitoring device in the event that the rst power supply becomes
unavailable.
______________________________________________________________________
A B
www.netoptics.com
Network
A B
LINK
ACT
Monitor
A B
ACT LINK ACT LINK
GigaBit
GigaBit
Converter Tap
Converter Tap
2
1
LASER
CAUTION!
To monitoring device NIC
To monitoring device NIC
Figure 5: Connecting to the Monitoring Device
7
Specications
Environment
Operating Temperature: 0˚C to 40˚C Operating Temperature: -10˚C to 70˚C
Relative Humidity: 10% min, 95% max, non-condensing
Power
Power Supply Input: 100-240VAC, 0.5A, 47-63Hz Output: 12V 1.5A
-48V Power Supply Input: -48V DC typical, -36V DC min, -75V DC max
Mechanical
Dimensions: 1.125” high x 6.5” deep x 4.5” wide
Cable Interface
Copper Cable Type: 22-24 AWG unshielded twisted pair cable, CAT5/CAT5e Link Distance Supported: 100 meters
Optical Interface
Transceivers: Class I, eye-safe, laser emitter type. These Class I Lasers conform to the applicable requirements per US 21 CFR (J) and EN 60825-1, also UL 1950 applications. Split Ratio: 50/50
Multimode:
Cable Type: Multimode Corning 50 or 62.5/125µm, wavelength 850nm
Insertion Loss: ≤ 4.5 dB
Optical Transmitter Wavelength: 850 nm nominal Output Power: -9.5 dB min, -4 dB max Optical Receiver Input Sensitivity: 0 dB min, -17 dB max
GigaBit SX/LX to TX Tap
Singlemode:
Cable Type: Singlemode Corning 8.5/125µm, wavelength 1310nm
Insertion Loss: ≤ 3.7 dB
Optical Transmitter Wavelength: 1310 nm nominal Output Power: -10 dB min, -3 dB max Optical Receiver Input Sensitivity: -3 dB min, -20 dB max
8
GigaBit SX/LX to TX Tap
Connectors
CVT-SXn/GCU model:
(2) RJ45, 8-pin connectors (monitor ports) (2) Duplex LC Multimode connectors (network ports)
CVT-LXn/GCU model:
(2) RJ45, 8-pin connectors (monitor ports) (2) Duplex LC Singlemode connectors (network ports)
Certications
Fully RoHS compliant
9
GigaBit SX/LX to TX Tap
Limitations on Warranty and Liability
Net Optics offers a limited warranty for all its products. IN NO EVENT SHALL NET OPTICS, INC.
BE LIABLE FOR ANY DAMAGES INCURRED BY THE USE OF THE PRODUCTS (INCLUD­ING BOTH HARDWARE AND SOFTWARE) DESCRIBED IN THIS MANUAL, OR BY ANY
DEFECT OR INACCURACY IN THIS MANUAL ITSELF. THIS INCLUDES BUT IS NOT LIM­ITED TO LOST PROFITS, LOST SAVINGS, AND ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OR INABILITY TO USE THIS PRODUCT, even if Net Optics has been advised of the possibility of such damages. Some states do not allow the exclusion or limitation of implied warranties or liability for incidental or consequential damages, so the above limitation or exclusion may not apply to you.
Net Optics, Inc. warrants this Tap to be in good working order for a period of ONE YEAR from the date of purchase from Net Optics or an authorized Net Optics reseller.
Should the unit fail anytime during the said ONE YEAR period, Net Optics will, at its discretion, repair or replace the product. This warranty is limited to defects in workmanship and materials and
does not cover damage from accident, disaster, misuse, abuse or unauthorized modications.
If you have a problem and require service, please call the number listed at the end of this section and speak with our technical service personnel. They may provide you with an RMA number, which must
accompany any returned product. Return the product in its original shipping container (or equivalent)
insured and with proof of purchase.
Additional Information
Net Optics, Inc. reserves the right to make changes in specications and other information contained
in this document without prior notice. Every effort has been made to ensure that the information in this document is accurate. Net Optics is not responsible for typographical errors.
THE WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHERS, EXPRESS OR IMPLIED. No Net Optics reseller, agent, or employee is authorized
to make any modication, extension, or addition to this warranty.
Net Optics is always open to any comments or suggestions you may have about its products and/or this manual.
Send correspondence to Net Optics, Inc. 5303 Betsy Ross Drive Santa Clara, CA 95054 USA
Telephone: +1 (408) 737-7777 Fax: +1 (408) 745-7719
Email: info@netoptics.com/Internet: www.netoptics.com
All Rights Reserved. Printed in the U.S.A. No part of this publication may be reproduced, transmit­ted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form, by any means, without prior written consent of Net Optics, Inc., with the following exceptions: Any person is authorized to store documentation on a single computer for personal use only and that the documentation contains Net Optics’ copyright notice.
10
www.netoptics.com
© 2009 by Net Optics, Inc. All Rights Reserved.
Loading...