Package Contents
Powerline
XAV1601
adapters
Resource
CD
Your adapters might look like one of these:
2
Ethernet
cables (2)
Page 5
XAVB1601v2_Full_IG.book Page 3 Thursday, November 8, 2012 9:04 AM
Hardware Features
Ethernet port
NETGEAR recommends
that you do not plug a
Powerline adapter
directly into a power strip.
Power LED
Ethernet LED
Powerline LED
Security
button
Factory Reset
button
3
Page 6
XAVB1601v2_Full_IG.book Page 4 Thursday, November 8, 2012 9:04 AM
LED Descriptions
ItemDescription
Power
LED
Powerline
LED
Ethernet
LED
• Solid green. The electrical power is on.
• Blinking green. The adapter is in the process of restarting
or setting up security.
• Solid Amber. The adapter is in power saving mode.
• Off. There is no electrical power.
• Solid green. The adapter is connected to a Powerline
network.
• Off. The adapter has not found any other compatible
Powerline devices using the same encryption key.
The Pick A Plug feature lets you choose the electrical outlet
with the fastest link rate, which is indicated by the LED color:
Green:
Link rate > 80 Mbps
(Fast)
• Solid green. The Ethernet port is linked or data is being
transmitted.
• Off. There is no Ethernet connection
Amber:
Link rate > 50 and <
80 Mbps (Medium)
4
Red:
Link rate < 50 Mbps
(Slow)
Page 7
XAVB1601v2_Full_IG.book Page 5 Thursday, November 8, 2012 9:04 AM
Button Descriptions
ItemDescription
Factory
Reset
button
Security
button
Filtered
AC
Socket
Warning: Do not press the Security/Power button on the Powerline adapter
until installation is complete, and the adapters are communicating with each
other (indicated by the blinking Powerline LED). Pressing this button too soon
can temporarily disable Powerline communication. If Powerline
communication becomes disabled, press the Factory Reset button to return
the Powerline adapter to its factory default settings.
Press the Factory Reset button for 1 second, and release it to
return the Powerline adapter to its factory default settings.
• After you plug in your new AV adapter, press the Security
button for 2 seconds, and then press the Security button on
one of the other AV adapters in your existing network for 2
seconds. Both buttons must be pressed within 2 minutes.
• Press the Security button for 10 seconds to put the adapter
into power saving mode. Press the Security button again
for 0.5 seconds to wake it.
The filtered AC socket can remove some electrical noise that
might affect Powerline performance. Plugging the power plugs
of nearby devices into the filtered AC socket might improve
performance.
5
Page 8
XAVB1601v2_Full_IG.book Page 6 Thursday, November 8, 2012 9:04 AM
Room 1Room 2
6
Page 9
XAVB1601v2_Full_IG.book Page 7 Thursday, November 8, 2012 9:04 AM
Compatible NETGEAR Powerline Devices
Compatible Powerline and HomePlug AV certified devices
include the NETGEAR XAVB1301, XAVB1401, XAVB2101,
XAVB2602, XAVNB2001, XAVB5601, XAVB5101, XAVB5201,
XAVB5602, XAUB2511, XAVB5004, XAVB1004, XWNB5602,
XWNB5201, and XWNB1601.
For a complete list of HomePlug AV certified devices, go to
www.homeplug.org/certified_products.
7
Page 10
XAVB1601v2_Full_IG.book Page 8 Thursday, November 8, 2012 9:04 AM
Safety Information:
•AC input:100–125V, 0.1A (Max: NA) and 200–250V, 0.1A (Max;
others), for product only.
•Operating temperature: 0–40°C
•The socket-outlet shall be installed near the equipment and shall be
easily accessible.
•XAV1601 ratings (maximum load):
EU: 16A 250VUK: 13A 250V NA: 10A 125V
•Only power cords are allowed to be inserted into the filtered AC
outlet; no other equipment with a direct plug-in is allowed. The
power cord needs to be a maximum of 1m long and a minimum of
0.75 mm square of cross-sectional area.
•Do not plug devices into the XAV1601 filtered AC outlet that exceed
the product ratings.The output voltage of the filtered AC outlet is the
same as the power outlet into which the XAV1601 is plugged. To
help avoid damaging your system, be sure that the attached devices
are electrically rated to operate with the power available in your
location.
•If the input AC voltage is less than 125 Vac, the device plugged into
the filtered AC socket of the XAV1601 might not perform as well as
expected.
•DO NOT PLUG MAJOR HOME APPLIANCES into the filtered AC
socket or into an attached powerstrip. The device is not intended to
be used with home appliances such as air conditioners, power tools,
space heaters, fans, hair dryers, ovens, or refrigerators.
•Check the electrical current for any appliance used with the device,
and do not exceed home and product outlet ratings and electrical
requirements.
Page 11
XAVB1601v2_Full_IG.book Page 9 Thursday, November 8, 2012 9:04 AM
User Manual
You can get the user manual online at
http://downloadcenter.netgear.com.
Compliance
For the complete EU Declaration of Conformity, visit:
This symbol appears in accordance with the European Union
Directive 2002/96 on the Waste Electrical and Electronic
Equipment (the WEEE directive). If you dispose of this
product in the European Union, treat and recycle it in
accordance with your jurisdiction’s laws that implement the
WEEE directive.
For indoor use only in all EU member states, EFTA states, and
Switzerland.
Page 12
XAVB1601v2_Full_IG.book Page 10 Thursday, November 8, 2012 9:04 AM
NETGEAR, Inc.
350 East Plumeria Drive
San Jose, CA 95134, USA
November 2012
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.