NetAlly NetAlly LRAT-1000 Manual

LinkRunner™ AT 1000/2000
Published 01/2020
Copyright © 2012 NetAlly All product names are trademarks of their respective companies.
Network Auto-Tester
User Manual
431 - 5 Commonwealth Ave, MA 01801 - TestEquipmentDepot.com

Contents

Title Page
I. Introduction ..................................................................................................................................................1
Link-Live Cloud Service ....................................................................................................................................................1
LinkRunner Manager ........................................................................................................................................................1
About this Manual ............................................................................................................................................................1
The NetAlly Website .........................................................................................................................................................2
Register Your Product ......................................................................................................................................................2
Contact NetAlly .................................................................................................................................................................2
Safety Information ............................................................................................................................................................2
Cleaning the Tester ..........................................................................................................................................................3
Kit Package Contents .......................................................................................................................................................3
II. Physical Features ........................................................................................................................................4
Battery Charging and Life ................................................................................................................................................5
Maintenance .....................................................................................................................................................................7
Accessories ........................................................................................................................................................................7
i
III. The Home Screen .......................................................................................................................................8
IV. Common Questions LinkRunner AT Can Answer ...................................................................................9
V. Link-Live Cloud Service .............................................................................................................................. 11
VI. Setting Up the Tester ................................................................................................................................. 12
IP Configuration ...............................................................................................................................................................12
VLAN/MAC/Proxy Configuration ....................................................................................................................................13
AutoTest Configuration ...................................................................................................................................................14
PoE Configuration ............................................................................................................................................................ 14
Connect Configuration ....................................................................................................................................................15
General Configuration .....................................................................................................................................................15
Reflector Configuration (Model 2000 only) ...................................................................................................................16
VII. Additional LinkRunner Tools .................................................................................................................... 17
LinkRunner Information .................................................................................................................................................. 17
Manage Files .....................................................................................................................................................................17
Restore Factory Defaults .................................................................................................................................................18
Update Firmware .............................................................................................................................................................19
Transfer Saved Profiles to/from LinkRunner Manager ...............................................................................................20
Set Language ....................................................................................................................................................................20
VIII. Using AutoTest, Switch, and Cable Test ..................................................................................................21
Using AutoTest .................................................................................................................................................................21
Using the Nearest Switch Test ........................................................................................................................................ 22
Using the Cable Test ........................................................................................................................................................ 22
ii
IX. Using the PoE Feature ............................................................................................................................... 23
X. Using the Reflector Feature (Model 2000 only) ...................................................................................... 27
XI. Using the Fiber Connection (Model 2000 only) ....................................................................................... 27
XII. Saving a Report ........................................................................................................................................... 28
XIII. Specifications .............................................................................................................................................. 29
Environmental Specifications .........................................................................................................................................29
General Specifications ..................................................................................................................................................... 30
LinkRunner Manager Software ......................................................................................................................................31
iii

List of Figures

Figure Page
1. Physical Features of LinkRunner AT.......................................................................................................................... 4
2. How to Remove/Replace the Batteries ..................................................................................................................... 6
3. The Home Screen ....................................................................................................................................................... 8
4. Tools Menu................................................................................................................................................................... 12
5. IP Configuration Screen.............................................................................................................................................. 12
6. VLAN/MAC/Proxy Configuration Screen ................................................................................................................... 13
7. AutoTest Configuration Screen.................................................................................................................................. 14
8. PoE Configuration Screen........................................................................................................................................... 14
9. Connect Configuration Screen................................................................................................................................... 15
10. General Configuration Screen ................................................................................................................................... 15
11. Reflector Settings Screen............................................................................................................................................ 16
12. Reflector Default Configuration Screen.................................................................................................................... 16
13. LinkRunner Information Screen with Connected Fiber Adapter........................................................................... 17
14. AutoTest Configuration Screen.................................................................................................................................. 21
15. AutoTest Results Screen ............................................................................................................................................. 21
16. Expanded Test Results................................................................................................................................................ 21
iv
17. Nearest Switch Results................................................................................................................................................22
18. Cable Test Results........................................................................................................................................................22
19. PoE Configuration on LR-AT model 1000..................................................................................................................23
20. PoE Configuration on LR-AT model 2000..................................................................................................................23
21. AutoTest results - PoE without TruePower...............................................................................................................24
22. Switch - PoE without TruePower................................................................................................................................24
23. AutoTest results - PoE with TruePower.....................................................................................................................25
24. Switch - PoE with TruePower......................................................................................................................................25
25. AutoTest results - PoE with TruePower and Measured Load.................................................................................26
26. Reflector Mode Screen................................................................................................................................................27
27. Fiber Connected Switch Results.................................................................................................................................27
v
LinkRunner AT 1000/2000
Network Auto-Tester
I. I
LinkRunner AT 1000/2000 Network Auto-Tester enables quick verification of Ethernet copper and fiber (2000 model only) cables as well as network connectivity and availability. The tester also identifies the network device to which it is connected, measures and displays PoE voltage and configuration, generates reports, and serves as a packet reflector for performance tests conducted with other NetAlly products.
The included Link-Live Cloud Service provides automated reporting and options for organizing test results while the LinkRunner Manager application allows you to save custom test profiles, manually load results, and update firmware.
NTRODUCTION

Link-Live Cloud Service

The Link-Live Cloud Service is a free, online system for collecting, tracking, and organizing your test results, which are automatically uploaded to Link-Live once configured.
See “Link-Live Cloud Service,” page 11.

LinkRunner Manager

LinkRunner Manager is a Windo updating your LinkRunner AT software, creating profiles, storing results, and generating reports. You can install LinkRunner Manager from the included CD or download the app
ws PC application for

About this Manual

This User Manual is designed to be easy to navigate on a screen, with Adobe PDF Bookmarks to the left, and blue
hyperlinks that point to other parts of the manual. Blue underlined links go to external resources on the internet.
LinkRunner AT 1000/2000 Network Auto-Tester is hereafter referred to as the LinkRunner AT or LR-AT.

Safety Information

Table 1 gives descriptions of the safety symbols used on the Tester and in this manual.
Table 1. Safety Symbols
W X
)
~
Warning or Caution: Risk of damage to or destruction of equipment or software.
Warning: Risk of electrical shock.
NOT FOR CONNECTION TO PUBLIC
j
TELEPHONE SYSTEMS CANADIAN STANDARDS ASSOCIATION
CERTIFIED TO CANADIAN AND US STANDARDS This product complies with the WEEE
Directive marking requirements. The affixed label indicates that you must not discard this electrical/electronic product in domestic household waste.
Product Category: With reference to the equipment typ I, this product is classed as category 9 “Monitoring and Control Instrumentation” product. Do not dispose of this product as unsorted municipal waste.
es in the WEEE Directive Annex
2
Meets Australia EMC Requirements.
*
CLASS 1 LASER PRODUCT. DO NOT LOOK INTO LASER
WWarnings
Use only the AC adapter provided to charge the battery.
To avoid possible electric shock or personal injury,
llow these guidelines:
fo
Do not use this product if it is damaged. Before
using the product, inspect the case. Look for crac
ked or missing plastic.
Do not operate the product around explosive
gas, vapo
No serviceable parts.
Do not try to service.
If this product is used in a manner not specified
by the by the
r or dust.
manufacturer, the protection provid product may be impaired.
ed
*
W
With an optional SFP fiber adapter installed, this product will contain a Class 1 laser. Do not look into the laser port because this may cause eye injury.
Warning Class 1 Laser Product
WCautions
Use the proper terminals and cable for all connections.

Cleaning the Tester

To clean the display, use a lens cleaner and a soft, lint-free cloth. To clean the case, use a soft cloth that is moist with water or a weak soap.
Caution
To prevent damage to the display or the case, do not use solvents or abrasive materials.
3
II.
6
7
8
17
16
15
19
18
9
10
11
12
13
2
3
4
5
1
14
P
HYSICAL FEATURES
Figure 1. Physical Features of LinkRunner AT
Physical Features
On/off key.
Makes a selection on the screen.
Shows the previous screen.
Softkeys. The function of the softkey is shown above the key.
Cable test wire mapping input. Connect the cable from the top Ethernet port to this port to view the wire map details.
Ethernet 10/100/1000BASE-X port.
Fiber port. Use one of the many supported SFP adapters to connect to the network.
Tx/Rx - The LED blinks when the tester transmits and receives data.
The LED is on when the tester is linked to the network.
Full-color LCD.
Softkeys. The function of the softkey is shown above the key.
4
Shows the Home screen.
O
: Clears the current measurement data.
P
: Saves the current measurements data into a report file, which can be transferred to the LinkRunner Manager PC application.
NOTE: If you are using Link-Live Cloud Service, results are automatically uploaded, and you do not need to save report files manually. See “Link-Live Cloud Service,”
page 11.
Navigation keys. The outer ring of keys (four) perform the left/right and up/down screen navigation.
Connector for the AC adapter.
USB port for connection to a PC.
Kensington lock slot.
Screw for the battery pack.
The LED turns on when you connect the AC adapter. The LED is red when the battery is charging and green when the battery is fully charged.
Physical Features

Battery Charging and Life

LinkRunner AT 1000 model includes a AA battery pack.
LinkRunner AT 2000 model includes a rechargeable Lithium­ion battery pack.
Additional AA and Li-ion battery packs are available separately.
To charge the Li-ion battery, connect the AC adapter to the battery connector (see Figure 1 number ). You can use the tester while you charge the battery.
When the tester is off, the battery charges in approximately 3 hours. The Li-ion battery life is approximately 6 hours during typical operation. The AA battery life is approximately 3 hours.
An icon in the upper-left corner of the screen shows the battery status .
NOTE: Do not leave the Li-ion battery pack in high temperatures, such as in a car on a sunny day.
The Li-ion battery will not charge if the internal temperature of the tester is above 113ºF (45ºC).
5
Loading...
+ 26 hidden pages