NESTOR MARTIN IQ13 Wood, IQ13 Multifuel Installation Manual

PART NUMBER
SERIAL NUMBER
Installation & Servicing Instructions
Nestor Martin IQ13
IN1264 Edition A October 2012
This manual must be used in conjunction with document IN1173. The Wood and Mutlifuel Chimney and Installation Guide.
Exempt
Smoke Control
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. October 2012 E & OE Instructions Part number IN1264 Edition A
2
Table of Contents
The Model Range Explained ....................................................................................................... 3
Technical Data, Intermittent Operation ....................................................................................... 5
Technical Data, Continuous Operation ......................................................................................... 5
General Technical Data ................................................................................................................. 5
IQ13 Aperture Size ........................................................................................................................ 5
IQ13 Dimensions .......................................................................................................................... 6
Housing Construction, without an Existing Chimney Breast ...................................................... 8
Ideal installation ........................................................................................................................... 9
Installation of Flue Spigot to Flue Pipe ..................................................................................... 10
The Flue ....................................................................................................................................... 10
The Hearth and Fire Surround .................................................................................................... 11
Minimum Air Setting .................................................................................................................. 12
Firebox Components ...................................................................................................................13
Removal of Frame ...................................................................................................................... 15
Fitting the Fresh Air Kit .............................................................................................................. 15
Ensure that all joints are sealed with a suitable fire resistant sealant we recommend Fraxfill (available from Euroheat Part No: MS9045). Some so called “Heat Proof” mastiks will only stand a temperature of 300°C before they start breaking down. In many cases they may give off an obnoxious smell at temperatures much lower than this which will persist and become apparent each time the stove is lit.
Since April 2002 only Registered Competent Engineers may install solid fuel fired appliances without involving the Local Authority Building Control Department. For more details contact HETAS. (Contact details page 3) Euroheat would suggest only Registered Competent Engineers such as HETAS approved engineers install Euroheat appliances.
If a competent engineer is not employed to install your appliance, building control must to contacted and a building control number is issued.
Carbon Monoxide Alarms
Where a new solid fuel stove is installed in a property a carbon monoxide alarm should be located in the same room where the appliance is located:
a. on the ceiling at least 300mm from any wall or, if it is located on a wall, as high up as possible (above any doors and windows) but not within 150mm of the ceiling; and
b. between 1m am 3m horizontally from the appliance.
Carbon monoxide alarms should comply with BS EN 50291:2001 and be powered by a battery designed to operate for the working life of the alarm. The alarm should incorporate a warning device to alert users when the working life of the alarm is due to end. Mains-powered BS EN 50291 Type A carbon monoxide alarms with fixed wiring (not plug in types) may be used as alternative applications provided they are fitted with a sensor failure warning device.
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. October 2012 E & OE Instructions Part number IN1264 Edition A
3
Useful organizations
Solid Fuel Association 0845 601 4406 www.solidfuel.co.uk The National Association of Chimney Sweeps 01785 811732 www.chimneyworks.co.uk HETAS Ltd. 0845 634 5626 www.hetas.co.uk
The Model Range Explained
Thank you for purchasing your stove and helping to protect our environment. Nestor Martin and Euroheat insist on progressive development to produce products which are market leading. Our aims are to produce stoves with the latest innovations, user friendly operation and highly efficient for lower cost operation. When burning wood you will be greatly assisting with reducing CO² to the environment when compared to coal, oil or gas. This installation manual offers user information for the Nestor Martin IQ13 Insert model.
Model Identification
You will see on the front page of this document a label which confirms which model you have. This label also advises you of the stove`s unique serial number. This information is also attached to your stove for reference.
Important
Please ensure the warranty registration form is completed if you are the installer and confirm with the user that it is their responsibility to return it to Euroheat. In this way the model and its history will be recorded for reference in the future. For the latest versions of manuals, technical information, accessories and spare parts visit the Euroheat web site.
Stoves Supplied Through Euroheat Authorized Retailers. For England, Wales, Scotland and Northern Ireland
Euroheat Distributors (H.B.S). Ltd. Unit 2, Court Farm Business Park, Bishops Frome, Worcestershire, WR6 5AY.
www.euroheat.co.uk
info@euroheat.co.uk
Whilst Euroheat are always happy to assist, please ensure you have read this manual and the chimney and installation guide IN1173. First contact your supplying retailer for assistance. If you find this not successful contact the Euroheat Technical Support Team. Technical support telephone Number 01885 491117. E-mail tech@euroheat.co.uk.
Before telephoning ensure you have the stoves serial number to hand and that you are a Registered Competent Engineer. If you are not a registered engineer seek one for assistance. A list of engineers can be obtained from HETAS.
Euroheat unfortunately are unable to offer support for appliances which were not supplied by Euroheat.
Stoves supplied through Eireheat authorized retailers. For Eire
Sean Murphy Heating Ltd Kinvara Co Galway Eire
www.eireheat.com sales@eireheat.com
(091)637701 Fax: (091)637797 International +353 91637701
For support for appliances supplied through Eireheat in Ireland please contact using the details listed above.
Thermic Distribution Europe Sa 11 Rue De Lion B-5660 Frasnes Les Couvin, Belgium.
www.nestormartin.com
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. October 2012 E & OE Instructions Part number IN1264 Edition A
4
IMPORTANT
.
The installation of this appliance must comply with all local regulations, including those referring to national and European Standards before it can be operated. The stove is not suitable for a shared flue. However, for England and Wales, only, the coming into force on 1st April 2002 of SI 2002 No 440 exempts the householder from this legal requirement for the installation of solid fuel fired appliance whose rated heat output is 50kW or less in a building having no more than 3 storeys (excluding any basement) if a Competent Engineer is employed who is registered under the Registration Scheme for Companies and Engineers involved in the Installation and Maintenance of Domestic Solid Fuel Fired Equipment operated by HETAS Ltd. These registered Competent Engineers may also carry out associated building work necessary to ensure that the installed appliance complies with Building Regulations without involving the Local Authority Building Control Department. The installing engineer should refer to BS 8303: Code of practice for installation of domestic heating and cooking appliances burning solid mineral fuels.
Improper adjustment, alteration, maintenance or the fitting of replacement parts not recommended by the manufacturer can cause injury or property damage. Do not operate the stove with faulty seals or damaged glass.
Due to the high operating temperatures of this appliance it should be located away from pedestrian traffic and away from furniture and draperies. Do not store paper or wood near the appliance. Any mats and rugs put in front of the stove should be fire proof and secured to prevent the possibility of tripping.
Advise all persons as to the stove’s high surface temperatures. If it is possible for children or infirm adults to come into contact with the stove, fit a suitable fire guard.
It is imperative that all air passageways into, out of, and within the appliance are kept clean. All permanent ventilation into the room provided for the stove must remain clear and unobstructed at all times. Consideration must be given to the need for extra ventilation if another heating source needing air is to be operated simultaneously. If an extraction fan is proposed to be fitted to a connecting area of the house, after the stove has been installed, professional advice should be sought from a qualified engineer.
The user should be advised that the appliance should be inspected and cleaned regularly and the chimney cleaned at least annually. More frequent cleaning may be required and the advice of a qualified chimney sweep should be sought.
Our range of stoves is capable of operating with outstanding efficiency if the flue system is correct. Because so little heat is wasted to the flue it is possible that moisture within the products of combustion will condense if the heat losses within the flue way are too great and allow the flue gases to cool. For this reason we recommend that the stove is fitted with a suitable flue liner, the same diameter as the flue spigot, to prevent the possibility of acidic damage to the fabric of the chimney and damage to the stove which will reduce the longevity of the stove. The flue pipe and chimney flue diameter must at no point be less than the diameter of the stove flue outlet. The installing engineer should refer to BS EN 15287-1:2007 design, installation and commissioning of chimneys.
When correctly installed, the stove is designed to produce heat, safely. It cannot do so if the installation is less than absolutely stable, constructed of materials suitable for such an installation and consideration has not been given to the possibility of people with less than ideal common sense operating it.
Have the existing chimney swept by a chimney sweep. Although you will be lining the chimney, any deposits left in the chimney will cause problems and may become a fire hazard.
Your attention is drawn to the precautions and responsibilities under the Health and Safety at Work Acts, and whatever new legislation being introduced during the life of this document. Especially to the possibility of disturbing asbestos when disturbing structures in older properties. Also the caustic nature of fire cement. The personal risk of injury when moving heavy items with possible sharp edges.
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. October 2012 E & OE Instructions Part number IN1264 Edition A
5
IQ13 Aperture Size
360mm Min
415mm
570mm
Technical Data, Intermittent Operation
Model
Heat
Output
Wood
Refuelling
Interval
Wood
Energy
Efficiency
Wood
Heat
Output
Smokeless
Coal**
Refuelling
Interval
Smokeless
Coal**
Energy
Efficiency
Smokeless
Coal**
IQ13 Wood 5 kW 0.70 hr
77.1% Net
70.2% Gross
IQ13 Multifuel 5 kW 0.70 hr
77.1% Net
70.2% Gross
3.5 kW 1.05 hr
82.8% Net
75.4% Gross
Technical Data, Continuous Operation
Model
Heat
Output
Wood
Refuelling
Interval
Wood
Energy
Efficiency
Wood
Heat Output
Smokeless
Coal**
Refuelling
Interval
Smokeless
Coal
Energy
Efficiency
Smokeless
Coal
IQ13 Wood 5.4 kW 1.45 hr
83.4% Net
75.9% Gross
IQ13 Multifuel 5.4 kW 1.45 hr
83.4% Net
75.9% Gross
3.5 kW 4 hr
78.3% Net
71.2% Gross
General Technical Data
Model
Model
Number
Weight KG Flue
Draught
Nominal
Flue Gas
Mass Flow
g/s
Flue Gas
Temperature
Down Stream of
Flue Spigot
Free Air
Requirement
IQ13 Wood IQ13* 108 12pa 4.9 350
0
c 0mm²**
IQ13 Coal IQ13* 108 12pa 3.8 210 0mm²**
** Free Air Requirement
Air requirement equivalent area. Building regulations Document J, advises that an air supply,permanently open vents, should be installed for appliances: If design air permeability >5.0m³/(h.m²) then 550mm²/kW of appliance rated output above 5kW or If design air permeability <5.0m³/(h.m²) then 550mm²/kW of appliance rated output. Equivalent air is as measured according to the method in BS EN13141-1:2004. It is unlikely that a dwelling constructed prior to 2008 will have an air permeability of <5.0m³/(h.m²) at 50pa unless extensive measures have been taken to improve air-tightness.
_
© EUROHEAT DISTRIBUTORS (H.B.S) LTD. October 2012 E & OE Instructions Part number IN1264 Edition A
6
IQ13 Dimensions
J
A
D1
D
B
I
H
G
C
E
F
Dimensions mm
A
Height 3 sided 50mm frame/25mm frame 605/580
A
Height 4 sided 50mm frame/25mm frame 626/576
B
Width of body 395
C
Depth of body 352
D
Height of body 560
D1
Height including flue spigot 600
E
Front to heat vent outlet centre 280
F
Front to flue outlet centre 220
G
Flue diameter (internal diameter) 125
H
Optional heat vent diameter (internal diameter) 100
I
Centre between flue and heat vent 140
J
Width with 50mm frame/25mm frame 505/455