Ness Security Products SecurityGuardII, Security Guard Owner's Manual

Page 1
SECURITYGUARD
OWNERS MANUAL
Page 2
Copyright by Ness Security Products
July 1998
To the best of our knowledge the information contained in this manual is correct at the time
of going to print. Ness Security Products or it’s suppliers reserve the right to make changes to the
WE CARE
Australia 131 241
New Zealand 0800 799
Page 3
TABLE OF CONTENTS
4
5
6
7
8 9
10
11 12 13
14
15 16 17
18
19
20
21
22
Back
PAGE
3
Introduction
SecurityGuard Overview
Override switch
Glossary of Terminology
Symbols Used
Typical SecurityGuard Alarm System
Peripheral Devices
Radio Key PIR Detector Reed Switch
Operating your Alarm
Arm / Disarm Emergency / Panic Home
Low battery
SecurityGuard, battery charging
Changing Batteries
Radio Key PIR Detector Reed Switch
Miscellaneous Alarms and Warnings
Alarm Tamper Check Detectors Fault Dialler
Detector Setup Options
Chime Detectors (24 Hour Detectors) Operating Mode summary
Maintenance
Troubleshooting
Summary of Operation and Displays
Page 4
T
hank you for purchasing your SecurityGuardII intruder alarm system. SecurityGuardII is a
revolutionary new radio based alarm system which has been
built to the highest quality standards possible
and complies with the Australian Standard for Intruder Alarm systems AS2201, United Kingdom Standard
BS4737 & BS6799 and Canada C22.2 CSAN
0
205-M-1983
SecurityGuardII has been designed specifically to keep your family, yourself and your valuables under constant
guard and give you peace of mind for their safety. SecurityGuardII works tirelessly 24 Hours a day whether you
are at home or away protecting the things that you value the most.
SecurityGuard is the result of many years of experience and research in the personal and home security
industry. The system is operated very easily using the pocket size Radio Key and the friendly seven segment
display but SecurityGuard’s apparent simplicity belies the powerful, sophisticated electronic system which
provides features not found on many systems. Testament to the sophistication and innovative design of
SecurityGuardII was the awarding of the coveted Australian Design Award to SecurityGuard in 1992 and again
in 1996.
SecurityGuardII is unobtrusive and stylish yet is very robust being made of an extremely tough polycarbonate.
When positioned correctly SecurityGuard’s inbuilt infra-red movement detector will detect movement in an
area of up to 12 metres x 12 metres. Research has shown that most intruders are frightened off once they realise
they have been detected. For this reason, SecurityGuard has been designed with a very loud siren to scare
intruders and alert your neighbours.
Used and maintained correctly SecurityGuardII will provide you with years of trouble free operation. We are
confident in predicting that you will be so impressed by your SecurityGuardII alarm system that you will want
to recommend one to your friends and family.
INTRODUCTION
4
• A very loud inbuilt siren
• An infra-red movement detector
• Long-life rechargeable battery
• Water proof Radio Key remote control
• Additional Reed Switches as required
• Panic alarm on the Radio Key
• Additional infra-red detectors as required
• Additional Radio Keys as required
• External Siren and optional Strobe (if fitted)
• Home mode
• Optional Telephone Dialler
SECURITYGUARD FEATURES
{
Page 5
SIREN The extremely loud siren sounds if
an intruder is detected or a Radio
Key emergency button is pressed.
It is also used to give you various
“Beep” warnings.
STATUS DISPLAY A very bright, red, dual 7 segment
display which is used to display
the status of SecurityGuard and
provide various warnings for
conditions such as Low batteries
etc.
DETECTOR An inbuilt
Infra-Red detector used to detect
movement from intruders in an area
of up to 12 metres x 12 metres.
5
SECURITYGUARD II
Detector
Charging Plug
Battery Charger
Power Outlet
O.K. Light
Siren
Status Display
O.K. / BATTERY Flashes briefly every 5 seconds if the
battery is charged and SecurityGuard
is functioning correctly. Flashes every
2 seconds in Home Mode.
On constantly and blink off every 5
seconds while battery is charging.
BATTERY CHARGER Used to charge SecurityGuard’s
battery. This low voltage device does
not
have any dangerous voltages at it’s
plug connected to SecurityGuard. DO
NOT use the charger on any other
appliance as damage to the appliance
or charger may occur.
BATTERY The internal rechargeable battery
will run SecurityGuard for around
3 to 4
months under normal operating
conditions, before it requires recharging.
EMERGENCY OVERRIDE KEY SWITCH
In case you lose your Radio Key or you cannot stop the Siren
on your SecurityGuard with your Radio Key then the Override
Keyswitch on the bottom of the SecurityGuard can be used to
totally disable SecurityGuard. Two keys are supplied and
should be kept in a safe place. Note that the Keyswitch cannot
be used to Arm and Disarm SecurityGuard. It completely
disables SecurityGuard when it is turned off.
The illustration above shows the keyswitch in the OFF position
(SecurityGuard Disabled).
If you have turned the Keyswitch off and back on again wait
at least 5 minutes after turning on before you ARM
SecurityGuard,
to allow the inbuilt PIR to settle otherwise false
alarms may occur.
WARNING: Do not press any Radio Key buttons until the
display has stopped flashing. If you turned your Keyswitch off
because you had a problem and the problem still exists after
you have turned back
on, then contact the service number you
CHARGE LIGHT
Page 6
6
The microcomputer based SecurityGuard forms the heart of your security system. Your Radio Key is a pocket sized device which transmits an encoded radio signal to tell the
SecurityGuard to go into one of three operating modes; Arm, Disarm or Home. Additionally the Radio Key can tell the SecurityGuard to create an Emergency Alarm at any time.
Additional detection devices called Passive Infra-Red Detectors (or P.I.R.s for short) can detect the movement of an
intruder by sensing their body heat. P.I.R.s are used to cover various critical areas of your premises where an intruder might enter or trespass and will transmit an encoded radio signal to tell SecurityGuard that there is movement present.
Reed Switches are detection devices which attach to doors and windows and are used to detect if a door or window has opened. A Reed Switch is made up of two parts; A Magnet which normally attaches to the moving portion of the door or window and a Reed which detects the presence or absence of the magnet. The Reed Switch transmits an encoded radio signal to tell SecurityGuard that a door or window has been opened.
Your SecurityGuard is said to be Armed or on when it allows all P.I.R. and Reed Switches to cause a full Alarm. Your SecurityGuard is said to be in Home mode when it allows only selected P.I.R. or Reed Switches to cause an Alarm. This is normally the case when you are home and wish to have part of your alarm active and part of it inactive to allow freedom of movement in that area. At all other times your SecurityGuard is said to be Disarmed or off when it does not allow any P.I.R. and Reed Switches to cause a full alarm.
When leaving your premises Arm your SecurityGuard using your Radio Key to enable it to detect intruders and generate an alarm. SecurityGuard will ignore detection devices for the Exit Time to enable you to depart your premises without triggering an alarm.
When you enter the premises the SecurityGuard will delay an alarm for a short Entry Time. Failure to Disarm SecurityGuard before this time will cause an alarm. Alternatively you can Disarm from outside the premises in which case no Entry Time is required.
An Alarm will cause the SecurityGuard Siren and External Siren to sound. The Sirens will sound for up to 5 minutes unless a Disarm signal is received from a Radio Key in which case the Siren will stop immediately. An optional Strobe Light will flash on the External Siren cover as a visible warning of an Alarm and continue flashing for one hour.
The External Siren has an inbuilt Tamper Switch which will cause an Alarm if an unauthorised attempt is made to disconnect the Siren.
GLOSSARY OF TERMINOLOGY
An Emergency Alarm or Panic can be created by pressing the side lever on any Radio Key for 2 seconds, an Emergency
Alarm will sound the sirens in the same manner that a normal Alarm does. An Emergency Alarm can be used to scare
intruders or alert friends or neighbours.
The SecurityGuard is fitted with a Rechargeable Battery which will normally run SecurityGuard for around 3 to 4 months before requiring recharging. A Battery Charger is provided which plugs into the SecurityGuard and plugs into a standard power point to recharge your battery as required.
The SecurityGuard displays all information by way of its Status Display. The Status Display is a very bright, red, dual 7 segment display which it can be seen from anywhere in the same room as the SecurityGuard and will display conditions such as status (Armed, Disarmed etc.) and warnings such as Low Battery etc.
At other times your SecurityGuard may have been programmed for one or more Reed Switches or P.I.R. Detectors sound a Chime warning. A Chime warning has a lower priority than an Alarm and therefore the SecurityGuard will only sound a series of beeps from it’s siren. Chime can be used for things such as front door alarms, pool gates, studies etc.
SYMBOLS USED IN THIS MANUAL
The following is a compilation of the terminology used throughout this manual and a short explanation of the terms.
Words of interest are written in Italics.
Display
Siren
Single Beep Three Beeps Double Beeps Chime Alarm
Light on or
flashing
Radio Transmission Button Press
OFFONOFF
ON
Page 7
REED SWITCH An alarm device used to sense the
opening of a door or window and transmits an alarm back to SecurityGuard.
SIREN COVER An outside secure housing for the siren
which alerts neighbours.
STROBE
An optional flashing light to alert police and neighbours.
DIALLER
A Device which connects to the telephone line to transmit alarm information to a Central Monitoring station.
THE FOLLOWING DRAWING SHOWS A TYPICAL SYSTEM.
7
TYPICAL SECURITYGUARD ALARM SYSTEM
SECURITYGUARD The microcomputer based heart of your
Security system.
RADIO KEY Pocket sized radio transmitter device used
to operate your alarm.
PIR An alarm device which senses movement
by detecting body heat and transmits an alarm back to SecurityGuard.
Optional Extra P.I.Rs
Optional Extra Reed Switches
Radio Keys
Power Outlet
Battery Charger
OFF
ON
OFFONOFF
ON
Optional Dialler
to telephone line
Outside Siren
Page 8
BATTERY
The Radio Key uses a 3 Volt Lithium Coin Cell, we recommend the following brands; Panasonic CR 2016 Sony CR 2016 or equivalents.
The Radio Key is your means of controlling SecurityGuard. It does this by sending an encoded radio signal which is deciphered by SecurityGuard. The Radio Key is fully waterproof and uses a long life Lithium battery which under normal use will last approximately 2 years* .
You can control your SecurityGuard with up to 8 individual Radio Keys each with their own unique high security codes programmed into SecurityGuard. All of your Radio Keys can be used to; Arm, Disarm or turn SecurityGuards Home mode on. All radio keys can also create an Emergency Alarm at SecurityGuard.
Button
Press once to ARM SecurityGuard. Press twice within 3 seconds to place SecurityGuard into HOME mode.
Button
Press once to DISARM SecurityGuard or to stop an ALARM.
EMERGENCY PANIC BUTTON
Press this button for at least 2 seconds to create an Emergency Alarm. ( This button has an inbuilt delay to minimise the chance of false activations from accidental pushes of the button).
OK LIGHT
The light illuminates when the Radio Key is transmitting a signal. If the light flashes or does not illuminate then the battery may be low or flat. Under these conditions your Radio Key will still operate, although with possible reduced radio range. You should change the battery as soon as possible.
SecurityGuard will normally warn you of a low battery in your Radio Key.
Some models of Radio Key have a different location for the OK Light.
8
RADIO KEY
Should you mislay a Radio Key or you require an extra Key,
contact the service number you were provided with at the time of installing to arrange the supply of a new Key and
have your SecurityGuard reprogrammed to ignore the lost Key and to recognise the new Radio Key.
INTERNATIONAL RADIO KEY
This key uses a 12V lighter style battery, we recommend that you only use alkaline type batteries,
Duracell MN21 Energiser A23 or equivalents.
EMERGENCY PANIC BUTTON
OK LIGHT
OFF
ON
OFF
ON
OFF
ON
+
2016
* 1 year for the International Key
ON
OFF
Page 9
RED ALARM LIGHT
Illuminates for 5 seconds whenever an Alarm message is being transmitted to the SecurityGuard.
(There must be no movement in the room for at least 4 minutes before an Alarm message will be sent).
Flashes when an Alarm is transmitted and the battery is low.
LENS
The lens directs Infra-red energy to the sensor inside the unit. Keep the lens clean at all times.
DO NOT PAINT !
LOW BATTERY
The Red Alarm Light will change from a steady light to a flashing light when the battery is low. SecurityGuard will warn you when the battery is low and needs replacing. You should replace the battery as soon as possible after the warning.
The PIR uses a special 9 Volt Lithium battery which should provide a battery life of between 2 and 3 years. We recommend you only use a Lithium battery as a replacement. The life of other types of batteries such as Alkaline is several times less than a Lithium.
Ultralife U9VL or equivalent.
COVER CLIPS
These are used to hold the cover of the sensor. To release the cover of the sensor when changing the battery, use a small screwdriver to gently lever the cover off the base to overcome the clips. (see changing batteries)
INTERNATIONAL PIR
These are used to open the cover of the sensor. To release the cover use the tip of a pen or a small screwdriver to depress these clips
OPTIONAL PIR OPERATION
PIR detectors are able to sense movement by detecting small changes of Infra-red energy in the area that they are looking at. PIR detectors use special filters which are tuned to the Infra-red energy produced by human beings, they use advanced lenses to gather the Infra-red energy in a room and focus it back to a sensor inside the unit.
SLEEP MODE
Your PIR detectors are always active by scanning their area for movement. To conserve battery life and to limit unwanted radio transmissions the PIR waits until all movement in the room has ceased for at least 4 minutes before it transmits an alarm message to the SecurityGuard. Thus constant movement in a room will not cause constant alarm messages to be sent and battery power is conserved.
Note - Although an alarm message is sent by the PIR, the SecurityGuard determines if it should sound a siren or not depending on whether it is Armed or Disarmed.
9
PASSIVE INFRA-RED DETECTOR PIR SENSORS
WARNING
Infra-red energy will not pass through solid objects. Do not place furniture etc. in front of the PIR.
Do not place heaters or similar devices close to your PIR sensors, as the heat generates Infra-red energy and may
cause false alarms when you have ARMED your SecurityGuard.
Alarm Light
Lens
Cover Clips
Page 10
RED ALARM LED
Illuminates for 5 seconds whenever an Alarm message is being transmitted to the Securityguard
(An Alarm message is transmitted when the door or window is opened and also closed again).
Flashes or will not illuminate when battery is low.
MAGNET
A small magnet housed inside a plastic case, normally mounted on the moving part of a door or window.
REED SWITCH
The Reed and the main electronics are housed in the larger plastics. The Reed senses the presence or absence of the magnet and transmits an Alarm message accordingly.
The Shock Reed can also detect an attack on surfaces such as windows, doors, walls etc by the addition of external shock sensors.
LOW BATTERY
The red alarm led will not illuminate when the battery is low and requires replacing. Securityguardwill warn you when the battery is low. Although the Reed Switch will still function when the battery is low you should replace the battery as soon as possible after a low battery warning.
The Reed Switches uses special Lithium batteries which should give a battery life of between 2 an 3 years under average usage. We recommend you only use a Lithium battery as a replacement. The life of other types of batteries such as Alkaline is several times less than a Lithium.
Shock Reed Ultralife U9VL or equivalent. Mini Reed CR2032 Lithium.
COVER CLIP
This is used to open the cover of the Reed Switch to change the battery. Lever upwards with your thumb or finger.
OPTIONAL REED SWITCH OPERATION
Reed switches are able to detect the opening of doors and windows by detecting the presence or absence of a magnet. The Reed Switch is made up of two pieces; A magnet which normally is placed on the moving part of a door or window and the Reed which is housed inside the main unit.
Your Reed Switch is always active checking to see if the door or window that it is installed on has opened. When the Reed Switch senses an opening it transmits a coded Alarm message back to Securityguardand Securityguardthen determines what it should do with the message i.e. It may choose to sound an Alarm or sound a Chime depending on whether it is Armed, Disarmed or in Home mode.
The Reed switch will transmit an Alarm message to tell Securityguardwhen a door or window is opened and again when it is closed.
10
REED SWITCH DETECTION DEVICES (OPTIONAL)
NOTE
The Battery life of your Reed Switch is directly related to the number of times that it is opened and closed.
For the Shock Reed the Battery will last about 3 years if the Reed Switch is opened and closed approx 25000 times
or about 24 times a day and about 2 years if the Reed Switch is opened and closed about 35 times a day.
The Mini Reed battery will last about three years if it is activated twice a day. Unnecessary opening and closing
a window or door on which the Reed Switch is installed will diminish the battery life.
REED SWITCHES
MINI REED SHOCK REED
Cover Clip
Magnet
Red Alarm Led
Red Alarm Led activated
Reed
Switch
separated
Magnet
Red Alarm Led
Page 11
OTHER WARNINGS
When you Disarm your SecurityGuard it may have some warnings to give you. SecurityGuard will alert you by sounding a series of Beeps or double beeps instead of the normal 3 Beeps and a message will be displayed accordingly.
The warnings may be for Low Battery or Alarms, these are fully explained later in this manual.
The Display will remain flashing for 5 minutes after you Disarm, you may choose to stop the display by pressing OFF once. You can also recall warning displays at any time by simply pressing OFF again, this will bring the flashing display back for another 5 minutes.
When SecurityGuard has more than one warning to give, pressing the button repeatedly will cycle you through the displays.
ARMING
To Arm your SecurityGuard press the button on any Radio Key.
Your SecurityGuard will Beep once and will be displayed.
Your SecurityGuard will be programmed with a short Exit Time, this allows you to depart your premises without triggering an alarm. Your SecurityGuard will Beep once more to warn that
Exit Time has finished and it is now ready to detect intruders.
DISARMING
To Disarm your SecurityGuard press the button on any Radio Key.
Your SecurityGuard will Beep three times and will be displayed.
When Disarmed the O.K. light will flash once every 5 seconds to indicate that SecurityGuard is happy and all is O.K. If the
Battery Charger is plugged in the O.K. light will be on constantly
and blink off once every 5 seconds.
11
OPERATING YOUR ALARM
OPTIONAL
Your outside siren may beep when you Arm and
Disarm if programmed.
If a Strobe light is fitted to your outside siren, it will flash briefly when you Arm and Disarm
Clear
ON
OFF
OFF
OFF
OFF
OFFONOFF
ON
Page 12
TO TURN THE SIREN OFF
Press the button on any Radio Key
When the siren has stopped SecurityGuard will flash the number of the Radio Key which caused the alarm along with a
for panic.
This is handy if a Radio Key has accidentally triggered your alarm and you are not sure which Key caused it.
Example
If Radio Key number 2 caused the Panic alarm then SecurityGuard will flash for 5 minutes. As with all SecurityGuard displays, you may choose to clear or recall the display at any time by pressing .
EMERGENCY OR PANIC
In case of emergency you can sound the siren immediately to alert neighbours or to scare away intruders by pressing the small Panic button on any Radio Key for at least 2 seconds.
(The Panic button has an inbuilt delay to minimise the chance of creating accidental alarms).
The inside and outside siren will sound
and the strobe (if fitted) will flash.
OPTIONAL SILENT PANIC
If you have an optional dialler fitted then your SecurityGuard may be programmed not to sound the sirens when you press your Panic Button. If this is the case then your SecurityGuard will send an Emergency message to an Alarm Monitoring Base Station via the telephone line and the Alarm monitoring station will action the alarm as required by you.
This may be useful in home Medical applications where emergency assistance can be summonsed by the carrier of a
Radio Key whenever they are in difficulties.
12
OPERATING YOUR ALARM
NOTE
Each one of your Radio Keys has been allocated a
number from 1 to 8. This number is used to identify things like which Key has a Low Battery or caused a Panic Alarm.
The Radio Key Number and user name are listed in the
table on the back of this manual.
OFF
OFF
OFFONOFF
ON
Page 13
ALARMS
Your SecurityGuard will be programmed to sound one of two types of Alarm in Home mode, when a home detector is triggered;
Full Alarm Where the normal Alarm siren will sound
for up to 5 minutes.
Home Chime Where your SecurityGuard will sound a
low volume two-tone siren for 5 seconds whenever a Home detection device is triggered.
DISARMING
To turn SecurityGuard Off or to stop any alarms that have happened in Home mode Press on any Radio Key once.
SecurityGuard will beep 3 times and will be displayed.
OPTIONAL HOME MODE
Your SecurityGuard alarm system may be programmed to operate a Homemode. Home mode allows some Detection devices (PIRs and Reed Switches) to cause an alarm while other detection devices are ignored. This is normally used while you are at home and want certain areas of your home secure while you are there.
To place SecurityGuard in Home mode
Press the button on any Radio Key twice within 3 seconds.
Your SecurityGuard will beep 5 times and will be displayed thereafter, the O.K. light will flash once every 2 seconds to indicate SecurityGuard is in Home mode.
If the battery charger is plugged in and the O.K. light is illuminated constantly it will blink off every 2 seconds to indicate SecurityGuard is in Home Mode.
Note - Exit Time applies to Home mode as per normal Arming, therefore one extra beep will sound at the end of Exit time.
13
OPERATING YOUR ALARM
or
NOTE
The detection devices required to be in
Home Mode will be set by your technician
at the time of installation
Refer to the table on the back page
for home detectors.
OFF
OFFONOFFONOFF
ON
Page 14
BATTERY CHARGING
SecurityGuards battery should only need charging every 3 to 4 months under normal usage. SecurityGuard will warn you when it’s battery needs charging by sounding a series of double beeps for 3 seconds when you Disarm after the normal 3 beeps SecurityGuard will also flash on it’s display for 5 minutes.
(As with all SecurityGuard displays you may choose to stop the display before the 5 minutes by pressing on any Radio Key).
When SecurityGuard has a low battery it will continue to function normally for up to a week, however you should charge SecurityGuard as soon as possible.
Plug your Charger into the bottom of your SecurityGuard and into the nearest power point.
WHEN YOU PLUG IN THE CHARGER
• The O.K. / Battery Charge light will illuminate constantly and blink off every 5 seconds.
• The Lo display will extinguish, to indicate that the battery is charging.
• When the battery is fully charged the O.K. light will revert back to it’s normal blink on every 5 seconds and the charger may be disconnected.
• The battery will take approximately 24 hours to fully charge.
14
BATTERY CHARGING
Although SecurityGuard may only need charging every 3 to 4 months you may intend to be away for extended periods of time and you may not be sure when you last charged SecurityGuard. SecurityGuard has been designed to safely leave the charger connected permanently so you may wish to leave the charger plugged in for the time you are away or if it is more convenient you may wish to leave it permanently connected.
NOTE
There are no dangerous voltages present at
your charger and it is quite safe to handle,
however please keep it away from excessive moisture
as damage may occur to the charger.
Keep the charger plug clean and always inspect it before
plugging into SecurityGuard to ensure that no dust or other
material has collected inside.
Display is clear
OFF
OFF
ON
Page 15
RADIO KEY LOW BATTERY
SecurityGuard will warn you when a Radio Key which has operated recently has a Low Battery. The Low Battery warning is normally given when SecurityGuard is Disarmed.
SecurityGuard will flash the Radio Key number for 5 minutes along with a on it’s display and will sound a series of double beeps for 3 seconds to warn of the problem.
Example
If Radio Key number 3 (User 3.) has a Low Battery then SecurityGuard will flash for 5 minutes and double beep
for 3 seconds at Disarm.
(As with all SecurityGuard displays you may choose to stop the display before the 5 minutes by pressing OFF on any Radio Key).
The O.K. light on the Radio Key will flash or not illuminate when there is a Low battery, however the Radio Key should still function for some time.
Some models of Radio Key have a different location for the OK Light.
15
RADIO KEY LOW BATTERY
TO REPLACE BATTERY
1. Using a coin, turn the Battery cover
anticlockwise and remove.
2. Lever the battery out with a small screwdriver or knife.
3. Replace the Battery with a 3 Volt Lithium type; Panasonic CR2016 Sony CR2016
Ensure the battery is the correct way in with the + side facing up.
4. Re-assemble the Battery cover making sure that the dot on the Battery cover matches the dot on the key and turn cover clockwise to tighten.
INTERNATIONAL KEY
1. Glide battery hatch off. You may need to use a
small screwdriver or knife to help lever, the hatch off.
2. Replace the battery with a 12 Volt alkaline type battery;
Duracell MN21 Energiser A23 Vinnic L1028
or equivalents.
Ensure the Battery is in the correct way, you can test this by pressing the OFF button and
checking
that the light illuminates
before re-assembling the
Radio Key.
3. Re-assemble the battery hatch.
NOTE
Each one of your Radio Keys has been allocated a number
from 1 to 8. This number is used to identify things like
which Key has a Low Battery or caused a Panic Alarm.
The Radio Key Number and user name are listed in a
table on the back of this manual.
OFF
OFFONOFF
ON
OFF
ON
ON
OFF
After replacing the Radio Key battery, test that the Radio key is functioning correctly by Arming and Disarming your SecurityGuard and checking that the O.K. light illuminates on the Radio key.
Page 16
PIR LOW BATTERY
SecurityGuard will warn you when a P.I.R. has a Low Battery. The Low Battery warning is given when the low battery occurs.
SecurityGuard will flash the P.I.R. number for 5 minutes along with a on it’s display and it will sound a series of double beeps for 3 seconds, ten seconds after the low battery occurs to warn of the problem.
Example
If P.I.R. number 2 (Detector 2) has a Low Battery then SecurityGuard will flash for 5 minutes and double beep
for 3 seconds.
(As with all SecurityGuard displays you may choose to stop the
display before the 5 minutes by pressing OFF on any Radio Key.)
The P.I.R. will flash it’s Red Alarm Light when it has a Low battery each time it transmits an Alarm message. Remember though that the P.I.R. will only trigger and transmit alarm messages when all the movement in the room has ceased for at least 3 minutes.
16
PIR LOW BATTERY
TO REPLACE BATTERY
1. Remove the cover of the PIR by gently
levering the two halves apart at the bottom using a small screwdriver or knife where the cover meets the base and twist. Swing the cover out from the bottom and off the middle hook.
2. Replace the battery with a 9 Volt Lithium type battery; Ultralife U9V or equivalent.
Do not place your fingers unnecessarily on the circuit board, particularly on the round Infra-red sensor as these are very delicate and the PIR could be rendered inactive.
3. Replace the cover by first attaching the top hook and closing the lid firmly until it snaps shut into the bottom clips.
4. To test that the PIR is working correctly you will need to leave the room for at least 4 minutes while the P.I.R. settles after being powered up and it waits for movement in the room to cease.
Enter the room after the 4 minutes, check that the Red Alarm Light on the PIR illuminates.
Your PIR is working correctly and ready for use.
INTERNATIONAL DETECTORS
1. Remove the cover of the P.I.R. by depressing either the small catch at the top of the cover or the two bottom catches on the cover, with a small flat bladed screwdriver or similar object and then pull the cover away from the base.
2. Replace battery as indicated on the circuit board Caution: Battery may explode if mistreated. Do not
recharge, disassemble or dispose of used batteries promptly, keep away from children.
Only replace battery with Ultralife 9 Volt Lithium U9VL Use of another battery may present a risk of Fire or Explosion
Try to not place your fingers on the circuitry, particularly the round Infra-red sensor as these are very delicate.
3. Replace the cover by first aligning the bottom clips and the small triangular lens on the bottom of the cover to the slots in the base by holding the cover at an angle, then close the cover and push firmly at the top until the it snaps shut into the top clip.
4. To test that the P.I.R. is working correctly you will need to leave the room for at least 4 minutes while the P.I.R. settles after being powered up and it waits for movement in the room to cease.
Enter the room after the 4 minutes, check that the Red Alarm Light on the P.I.R. illuminates.
Your P.I.R. is working correctly and ready for use.
NOTE
Each one of your P.I.R.s has been allocated a number
from 2 to 8 ,(SecurityGuard is Detector number 1),
these should be identified and listed in the table on the
back of this manual.
OFF
Page 17
Securityguard will warn you when a Reed Switch has a Low Battery. The Low Battery warning is given when the low battery occurs.
Securityguardwill flash the Reed Switch number for 5 minutes along with a on it’s display and it will sound a series of double beeps for 3 seconds when the low battery occurs to warn of the problem.
Example
If Reed Switch number 4 (Detector 4) has a Low Battery then Securityguardwill flash for 5 minutes and double beep for 3 seconds.
(As with all Securityguarddisplays you may choose to stop the
display before the 5 minutes by pressing on any Radio Key.)
The Reed Switch’s Red Alarm Light will flash or not illuminate when it sends an Alarm message and it has a Low battery. You can test if the Battery is O.K. by opening the door or window that the Reed Switch is mounted on. The Red Alarm Light should illuminate for 5 seconds. If it flashes or does not illuminate the battery should be replaced as soon as possible.
17
TO REPLACE BATTERY
1. Remove the cover of the Reed
Switch by lifting the small catch on the side of the larger housing. You should be able to do this with your thumb or finger, if not use a screwdriver to lever it off.
2. Your Securityguardmay be pro- grammed to recognise that the lid has been taken off a Reed Switch and a Tamper Alarm has been generated. If this is the case Securityguardwill sound a two­tone siren for 5 seconds and flash
for 5 minutes as a warning, this is normal and you can press on any Radio Key, to clear the display.
3. Replace battery as indicated on the circuit board. Caution: Battery may explode if mistreated. Do not recharge, disassemble or dispose of used batteries promptly, keep away from children.
Shock Reed Only replace with Ultralife 9 Volt Lithium U9VL Mini Reed Only replace with Panasonic 3 Volt Lithium CR 2032
Use of another battery may present a risk of Fire or Explosion
Try to not place your fingers on the circuitry as the components are delicate.
4. Replacement of the cover is the reverse of the removal
5. To test that the Reed Switch is working correctly you can
open or close the window or door that it is installed on and check that the Red Alarm Light turns on for 5 seconds.
Your Reed Switch is working correctly and ready for use.
NOTE
Each one of your Reed switches has been allocated a
number from 2 to 8, (Securityguardis Detector number 1),
these should be identified and listed in the table
on the back of this manual.
(step 1.)
REED SWITCH LOW BATTERY
REED SWITCH LOW BATTERY
+ side up
OFF
Page 18
SecurityGuard will try and warn you of any problems or if there has been an Alarm by flashing it’s display and sounding various beep warnings. Most warnings are provided when you next Disarm SecurityGuard although some may occur as they happen when you are home.
Warnings which have not been dealt with earlier in this manual include things like,
• Alarms that have occurred since you last Armed.
• A Tamper on your external Siren cover is opened.
• A PIR or a Reed Switch that has not triggered recently.
• A Dialler which is not working correctly.
ALARM
If you have had an Alarm from one of your PIRs or Reed Switches while you were away, SecurityGuard will warn you when you Disarm by giving a rapid series of beeps for 5 seconds and flashing the number of the device which caused the Alarm along with an , on it’s display.
Example
If SecurityGuard’s inbuilt PIR (Detector 1) alarmed while you were away, SecurityGuard will flash on it’s display for 5 minutes and beep rapidly for 5 seconds at Disarm.
(As with all SecurityGuard displays you can cancel the display by pressing OFF on any Radio Key).
18
MISCELLANEOUS ALARMS AND WARNINGS
TAMPER
While you were away
If you have had an Alarm caused by your External Siren Cover Tamper switch being opened while you were away, SecurityGuard will warn you when you Disarm by giving a rapid series of beeps for 5 seconds and flashing on it’s display for 5 minutes.
While you are home
If you have an Alarm caused by your External Siren Cover Tamper switch being opened while you are at home, SecurityGuard will warn you by sounding a low level 2 tone siren for 5 seconds and it will flash on it’s display for 5 minutes.
(As with all SecurityGuard displays you can cancel the display by pressing on any Radio Key).
OFF
OFF
OFFONOFF
ON
Page 19
CHECK DETECTORS
Your SecurityGuard has a special inbuilt feature which always ensures that your optional detection devices (PIRs and Reed Switches) are operating correctly and sending alarm messages as they are triggered.
Your SecurityGuard is constantly monitoring the alarm messages sent by your PIR and Reed Switch detectors and expects to receive messages on a regular basis, caused by your normal day to day activities. Of course SecurityGuard decides if it will create an alarm from those “alarm” messages depending on whether it is Armed or not.
However if SecurityGuard does not receive an alarm message from each one of the your additional detectors on a regular basis, SecurityGuard will warn you when you Disarm by sounding a series of double beeps for 3 seconds and flash the
number
of the suspect detector along with on it’s
display for 5 minutes.
( As with all SecurityGuard displays you can cancel the display before 5 minutes by pressing OFF on any Radio Key).
Example
If your PIR number 2 has not regularly alarmed then SecurityGuard will flash and beep a series of double beeps for 3 seconds when you Disarm.
What you Should do
If you receive this warning from a detector that you know should have triggered recently, then before you do anything else you should test the detector, if it is still not working you should replace the battery and test the detector as described in the PIR or
Reed Switch Low Battery sections of this manual.
If you still have a problem you should contact the service number you were provided with at the time of installation.
19
CONTINUED . . . .
CHECK DETECTOR WARNING(Optional) WHEN ARMING (Reed Switches only)
If you receive the Check Detector warning when you try to Arm your SecurityGuard then this is a warning that you have left a window or door open which has a Reed Switch detector on it.
SecurityGuard will warn you by flashing along with the detector number and give a series of double beeps for 3 seconds after you Arm.
If you receive this warning you should immediately Disarm your SecurityGuard. The warning is repeated when you Disarm, so that you can see the display and check the Reed Switch which caused the warning. Close the window or door before Re-Arming.
RADIO DIALLER (optional)
The Radio dialler is an intelligent standalone dialler which receives it’s alarm information via radio signal from your SecurityGuard. The radio dialler will warn you directly if there is a fault by sounding a beeper and/or flashing lights on the front panel, these are described below;
Mains
This light is normally on, when it is flashing it indicates that you do not have Mains supply, check that the Power Pack has not been disconnected or turned off at the power point. If Mains remains disconnected for longer than one hour then the dialler will beep a periodic warning to alert you.
Low Battery
If this light is flashing then the internal rechargeable battery is flat, if mains is plugged in and the problem persists then contact your Service Centre.
(Optional)
OFF
ON
Page 20
Radio Link
It is normal for this light to blink occasionally as SecurityGuard as SecurityGuard comunicates with the dialler. If however this light is flashing constantly then the Radio link between your SecurityGuard and your Dialler has failed. Check to make sure that your Securityguard is still operational if the problem persists Contact your Service Centre.
Line Fail
If this light is flashing check that your phone connection has not been unplugged. If it is O.K. then contact your Service Centre.
INTERNATIONAL DIALLER (optional)
The International Dialler is installed inside your SecurityGuard, if it has had trouble communicating with your Central Station it will warn you by sounding a series of double beeps for 3 seconds and will Flash “Fd” on it’s display for 5 minutes. If this occurs you should check your phone line connection to make sure the dialler has not been unplugged otherwise you should contact your nearest Service Centre immediately.
Your SecurityGuard allows for each of it’s detectors D1 to D8 to operate in various modes to suit your particular needs. Your installer has programmed these for you at installation. The more commonly used of those have been described earlier in this manual e.g. Alarm when Armed, Alarm when Home etc.
The way the detector has been setup is summarised on the back page of this manual under the column headed “Mode”.
Two of the least used setups or “Modes” of operation not described earlier in the manual are described below, they are Chime and Fire.
CHIME AND 24 HOUR DETECTORS
CHIME DETECTORS
Chime mode allows a Detector to sound a single pleasant two tone warning beep similar to a doorbell if the detector is triggered when your alarm is Disarmed. This may be useful if you want a warning if someone has entered or left a room without causing a full alarm while you are home e.g. You want to know if the children have gone into the study, or you want to
know if the children have gone into the backyard (particularly if you have a pool). A Chime Mode detector if triggered will flash the display with it’s number as well as an to show which detector caused the alarm.
Example
Detector 3 is setup for chime mode and is triggered,
is displayed
for 5 minutes and a single two tone beep is sounded.
24 HOUR DETECTORS
Detectors setup to operate in 24 Hour mode are operational at all times whether SecurityGuard is Armed, Disarmed or in Home mode.
When these detectors are triggered SecurityGuard will sound a full alarm with inside and external sirens sounding.
To silence the alarm
Press on any Radio Key, the detector number along with an
will be displayed for 5 minutes to identify which detector
caused the Alarm.
Example
Detector 6 triggers then is displayed for 5 minutes when an button is pressed on any Radio Key.
DETECTOR OPERATING MODE SUMMARY
A Alarm Alarm when Armed, inactive in Home and Disarmed. HHome Alarm when Armed and in Home mode, inactive when Disarmed. F 24 hour 24 Hour Alarm, always active. C Chime * Chime only in Disarmed, inactive in Armed and Home modes. AC Alarm/Chime ** Alarm when Armed, Chime when Disarmed, inactive when Home. HC Home/Chime ** Alarm when Armed, Chime when Home, inactive when Disarmed.
* Chime is a single two tone beep ** Chime is a low volume two tone siren which sounds for 5 seconds
CONTINUED . . .
DETECTOR SETUP OPTIONS
OFF
ON
Page 21
TESTING
We strongly suggest that you should carry out a full test of your alarm system at a minimum 6 monthly interval.
You should Arm your SecurityGuard and test that each of your PIR and Reed Switch detectors triggers an alarm as programmed. A test procedure is described for each detector in the replacing batteries section of this manual.
You could also check that your sirens are fully functional by triggering an Emergency alarm from your Radio Key.
CLEANING
Do not clean SecurityGuard with solvents like benzine or thinners and do not use commercial spray pack cleaners as the chemicals may attack the polycarbonate housing of SecurityGuard.
A light dusting and if necessary warm soapy water should only be used for cleaning.
The same applies for your Radio Key, PIR and Reed Switch housings.
INSECTS
Take particular care that insects like spiders and moths are not forming webs or similar around any of the PIR detectors
including SecurityGuards inbuilt detector. Insects can cause false alarms. Brush away any spider webs and if insects appear to be a problem spray around the detector with a surface insect spray.
Do Not Spray Directly Onto The Detector or Lens Area !
21
MAINTENANCE
BATTERIES
Your PIR, Reed Switch and Radio Key batteries should last approximately 2 years under normal usage when you use the recommended Lithium batteries. We would advise that you replace the batteries at this interval even if you have not received a Low Battery warning.
SPECIFICATIONS
SecurityGuard
Model No SG
II
Weight 2.4 KG Dimensions 800 x 115 x 80 mm Radio Frequency 303.875 Mhz. Aus, USA, Canada Radio Frequency 418 Mhz. UK 433 Mhz. Europe Siren > 120 db @ 1 metre Display Dual 7 Segments Battery 12 V Sealed Lead Acid 2.8 - 3.2 AH
Battery Charger
Voltage in 220v - 260v A.C. Aus, UK Voltage in 110v - 130v A.C. USA, Canada Voltage out 17 V A.C. @ 300 mA
Radio Key
Frequency 303.875 Mhz. Aus, USA, Canada Frequency 418 Mhz. UK 433 Mhz. Europe Battery 3V Lithium Coin Cell
12 V Alkaline (International Key) Transmit Power 10 uW PEP MAX. Aus, USA, Canada Transmit Power 100 mW PEP MAX. UK
P.I.R.
Frequency 303.875 Mhz. Aus, USA, Canada Frequency 418 Mhz. UK 433 Mhz. Europe Battery 9 V Lithium Transmit Power 10 uW PEP MAX. Aus, USA, Canada Transmit Power 100 mW PEP MAX. UK
Reed Switch
Frequency 303.875 Mhz. Aus, USA, Canada Frequency 418 Mhz. UK 433 Mhz. Europe Battery 3V Lithium Coin Cell ( Mini Reed )
9V Lithium (Shock Reed) Transmit Power 10 uW PEP MAX. Aus, USA, Canada Transmit Power 100 mW PEP MAX. UK
Manufactured in Australia by Ness Security Products Pty Ltd.
NOTE: Specifications subject to change without notice in the course of further development.
OFF
ON
Page 22
SYMPTOM POSSIBLE CAUSE REMEDY
warning is given or SecurityGuard Battery is Low Plug in Battery Charger and leave
keeps recurring plugged in for a minimum 24 Hours
Radio Key light does not Battery is Low or Flat Change Battery and test illuminate when button pressed and/or
warning is given Radio Key is Faulty Contact Number provided at the time of installation
Radio Key not working or Battery is Low or Flat Change battery and test Radio Range is Low and/or
warning is given Radio Key is Faulty Contact Number provided at the time of installation
Cannot enter Home mode Incorrect Radio Key operation Press ON twice within 3 seconds
No Home Detectors programmed Home mode cannot be entered if there
are no Home Detectors programmed
Red Alarm Light does not Constant movement in room There must be no movement for at least always illuminate on PIR 3 minutes in room, leave room for full
3 minutes before re-entering to test
PIR is Faulty Contact Number provided at the time of installation
warning is given PIR or Reed Switch battery Check the display to identify the
is low and needs replacing detector which caused the warning
and replace the battery
Red Alarm Light does not Battery is Low or Flat Replace battery and test illuminate on Reed Switch and/or
warning is given Reed Switch is faulty Contact Number provided at the time of installation
Fast Beeps sound at Disarm SecurityGuard has an Alarm Check the display, and refer to this instead of normal 3 beeps warning to give you manual for the cause of the Alarm
Double Beeps sound at Disarm SecurityGuard has a Low Battery Check the display, and refer to this anytime warning to give you manual for the cause of the Low Battery
PIR False Alarming Insects crawling on detector Clear spider webs or spray around the
detector with an insect surface spray
Do Not Spray Directly on PIR !
Air draughts caused by open windows Do not leave windows open near PIRs
when Alarm is Armed
Sensitivity settings to high Contact Number provided at the time of installation
PIR Faulty Contact Number provided at the time of installation
Pets in detection area Avoid having pets in areas protected by PIR’s.
22
TROUBLESHOOTING
Page 23
SYMPTOM POSSIBLE CAUSE REMEDY
Siren sounds unexpectedly Emergency button accidentally pressed Check the display to identify the cause of the Alarm when alarm is Disarmed on a Radio Key
Siren will not stop when a Radio Key Battery Low or flat Use Emergency override key to stop siren, Radio Key is pressed then replace battery in Radio Key and test
Display is flashing when you SecurityGuard has a warning to give you Note the warning message and consult Disarm this Manual for the cause
The flashing display can be cleared by pressing OFF on any Radio Key
Your External Strobe light is An Alarm occurred while you were away Disarm your alarm and check the display to find the flashing when you come home cause of the Alarm
is displayed and warning Your external siren cover has an Contact Number provided at the time of installation
beeps sound open tamper or your wiring is faulty
is displayed and A detector has not triggered recently Check the display to identify the detector, and test warning beeps sound when the detector as described in this Manual you Disarm
is displayed and warn- A Reed Switch is open on a Disarm check the display to identify the detector and
door or window close door or window
is displayed and warning Your Dialler has no phone line connection Check the Telephone lead is plugged in if it is accessible
beeps sound when you Disarm
The Phone line is not working Check your telephone and call your telephone provider if
there is no line
The Dialler is faulty Contact Number provided at the time of installation
An unusual Display not SecurityGuard program mode has Turn SecurityGuard OFF using the Override Keyswitch described in this manual inadvertently been activated on the bottom of SecurityGuard for 10 seconds and will not clear then turn back on
If the display does not clear after 5 seconds call your nearest Service Centre
A Display has cleared after Display stops after 5 minutes as normal Press off and the display is re-called for another 5 5 minutes and you want minutes to check it again
When trying to clear a This is normal if SecurityGuard has Press off to cycle through multiple Displays Display by pressing off , more than one warning to show you another warning appears
23
TROUBLESHOOTING
ing beep sound when you Arm
Page 24
OPERATION DISPLAY SOUND ACTION/DESCRIPTION
Arm Single Beep Press ON once
Disarm 3 Beeps Press OFF once
Home 5 Beeps Press ON twice within 3 seconds
Emergency rapid beeps for 5 seconds Press Red side lever for 2 seconds
WARNINGS
at Disarm double beeps 3 seconds SecurityGuard Low Battery
at Disarm double beeps 3 seconds Radio Key Low Battery
anytime double beeps 3 seconds PIR or Reed Switch Low Battery
at Disarm rapid beeps for 5 seconds Alarm from a Detector
at Disarm rapid beeps for 5 seconds Panic Alarm from a Radio Key
at Disarm rapid beeps for 5 seconds Alarm from Siren Cover Tamper
at Disarm double beeps 3 seconds Check Detector for correct operation
anytime double beeps 3 seconds Dialler not working correctly
DETECTOR GUIDE
TYPE LOCATION MODE SIGNAL STRENGTH MODE TYPES
D1 Main Unit A Alarm D2 H Home D3 F 24 hour D4 C Chime D5 AC Alarm/Chime D6 HC Home/Chime D7 D8
RADIO KEYS
U1 U2 U3 U4 U5 U6 U7 U8
SUMMARY OF OPERATION AND DISPLAYS
(c) Copyright Ness Security Products - JULY 1998
P/No 890-114 Rev.2
USER NAME
SIGNAL STRENGTH
Loading...