Ness S2 Installation And User Manual

Page 1
1
S2
Metal Waterproof Access Control Unit
Installation and User Manual
(Ness Part No. 101-082)
Page 2
2
Introduction
Ness S2 is an advanced, waterproof (IP65 rated) proximity and PIN Access Controller. S2 can support 2500 users utilizing three access modes; Card only - Card plus PIN - Card or PIN
S2 can operate in standalone mode, with its internal relay activating when an authorized user is granted access or can interface to 3rd party products via its 26 Bit Wiegand output
Installation
Drill a hole in the wall to match the location of the cable at the rear of the S2 or mount a suitable wall mount junction box
Thread the cable through cable hole and connect related cables. Take care to insulate the unused cables to prevent shorting
Fix the back cover to the wall or distribution box with screws and secure the controller to the back casing
Connection Diagram
Page 3
3
Programming
0 - Resetting to Factory Defaults
To reset to factory defaults, power off then press and hold the * key while powering up. S2 will beep twice and the LED will glow orange. Release the * key and the S2 will be ready for one of the following options:
1) Presenting the “Add User Master Card” to S2’s Reader to add a new user
2) Presenting the “Delete User Master Card” to delete a current user
3) Presenting a blank EM card to replace an “Add User Master Card” or “Delete User Master Card”. In this
case the first blank card presented will become the new “Add User Master Card” and the second blank card presented will become the new “Delete User Master Card”. The LED will flash Red confirming that S2 has been reset to factory defaults and new Master Cards added. If the new Master Cards are not presented within 10 seconds S2 will resume User Operating Mode and the LED will glow steady Red
When resetting to factory defaults the user's information is still retained
1 -
Entering Programming Mode
(Default Master Code = 888888
)
Press * then enter the Master Code followed by # (e.g. * 888888 #) S2 will enter Program Mode, the LED will flash Green for one second and then glow steady Red while S2 awaits Program Option Commands. To Exit Program Mode press *. If no keys are pressed for 60 seconds S2 will automatically exit Program Mode and resume Operation Mode
The following options can be accessed and programmed in Program Mode
2 -
Changing the
Master Code
(Master Code must be 6 digits long)
(Can only be done in Master Programming Mode)
Press 0 - The LED will glow Orange. Enter a New Code followed by # then re-enter the same New Code followed by # . The LED will flash Green if successful
Press
0 New Code
#
Confirm New Code
#
Up to 2500 user cards can be added. The first two options are available in Program Mode only and the third is also available in Operation Mode
3.1 Adding Card Users Automatically in Program Mode (Not recommended)
Press 1 - The LED will glow Orange. Present a blank card to the Reader. S2 will automatically assign the first card
as User Card 1. When successful the LED will flash Green. Repeat this process for all new cards and then press #
This method is not recommended because S2 will automatically allocate added cards to the next available
empty card slot. This makes it difficult to delete a card as its allocated card slot (ID number) will not be known
3 -
Adding Users
(Can only be done in Master Programming Mode)
Press
1 Present Card 1
Present Card 2
Present Card 3
… #
Page 4
4
3.2 Adding Card Users Manually
(Recommended method)
Press 1 - The LED will glow Orange. Enter the ID Number (Memory slot number 1 -> 2500 of the card you wish to add) followed by #. Present the new card to the Reader. When successful the LED will flash Green. If more cards are to be added repeat the process. Press # to end
Press 1
Enter ID
No.1
#
Present
Card 1
#
Enter ID
No.2
Present
Card 2
#
S2 will auto assign PIN “1234” (Factory Default) to programmed cards. If the system is set for ‘Card AND PIN’
for access you must go to “User Settings” and assign an individual PIN to each card
This is the recommended method of adding Card Users as the ID Number of all cards programmed will be known making it easy to select any individual card you may wish to delete
3.3 Adding “PIN Only” Users (No card)
Press 1 - The LED will glow Orange. Enter the ID Number (Memory slot number 1 -> 2500 of the User) followed by #. Enter a PIN for that User. When successfully added the LED will flash Green. Press # to end. If more Users are
to be added repeat the process for each User
Press
1 Enter ID No.1
# Enter PIN 1
#
Enter I
D No. 2
Enter PIN 2
# ...
All PIN numbers must be 4 Digits of any number combination, however they must not be 1234
3.4 Adding Card Users Sequentially
Multiple Users can be added sequentially as either a Card or Pin
Press
1
Present Card 1
to the Reader
Enter ID
No.1
Present Card 2
to the Reader
Enter ID
No. 2
Enter
PIN 3
#
Enter ID
No. 3
#
3.5 Adding Users with the “Add User Master Card”
User Cards can be added anytime without entering Program Mode by using the “Add User Master Card” that comes with the unit (or card that you have programmed)
Present “Add User Master Card” to the Reader - The LED will glow Orange. Present the Card to be added. When successfully added the LED will flash Green. Present any additional cards to be added in sequence. When complete Present “Add User Master Card” again. The LED will flash Red
Present ‘Add User Master
Card’ to the reader
Present each Card to be added
to the reader in sequence
Present ‘Add User Master
Card’ to the reader to exit
If the card being added is already in the system S2 will respond with 3 beeps
Page 5
5
4 -
Deleting
Users
(Can only be done in Master Programming Mode)
4.1 Deleting Users Automatically
Press 2 -The LED will glow Orange. Present each Card to be Deleted to the reader in sequence. As each card is successfully deleted the LED will then flash Green. Press # to exit
Press 2
Present Card 1
to be deleted
Present Card 2
to be deleted
Present Card 3
to be deleted
… #
4.2 Deleting Users Manually
If the card to be deleted is lost or unavailable the ID Number of the User (Memory Slot the User is programmed into) must be used to identify the User
Press 2 - The LED will glow Orange. Enter the ID number of the User to be deleted then press #. When successfully deleted the LED will flash Green. Repeat this process for any more Users to be deleted
Press 2
Enter ID
Number
of the
User to be deleted
#
Enter
ID
Number
of the
next User to be deleted
… #
4.3 Deleting ALL users
Press 2 - The LED will glow Orange. Press 0000 followed by the # button. The LED will then flash Green confirming
that all Users have been deleted
Press
2 0000
#
4.4 Deleting Users using the “Delete User Master Card”
Cards may be deleted anytime without entering Programming mode using the “Delete User Master Card” that comes with the S2 (or other programmed card)
Present “Delete User Master Card” to the Reader - The LED will glow Orange. Present the Card to be Deleted. When successfully Deleted the LED will flash Green. Present any additional Cards to be Deleted in sequence.
Present the “Delete User Master Card” to the reader again to complete. The LED will flash Red
Present the ‘Delete User
Master Card’ to the Reader
Present each Card to be added to
the Reader in sequence
Pre
sent the ‘Delete User
Master Card’ to the Reader
If the card being deleted is not in the system the S2 will respond with 3 beeps
Page 6
6
6 –
Door
Access Control
Settings
(Can only be done in Master Programming Mode)
Three programming options for Door Access Control are provided; Card Only, Card AND PIN or Card OR PIN
6.1 Grant Access by Card Only
6.2 Grant Access by Card AND PIN
6.3 Grant Access by Card OR PIN (Factory Default )
7 –
Door
Relay Time Set
ting (U
nlock Time)
–>
Default = 5 Seconds
(Can only be done in Master Programming Mode)
This option sets the activation time of the Relay when Access is granted by Card or PIN
Press
4 Enter Activation time (0
->99 Seconds)
#
8 –
Door Open Detection Se
ttings
(Can only be done in Master Programming Mode)
These options are used to Enable / Disable the “D_In” (Door Switch Input).
Press
60 # Disables the Door Open Detection
Input
(Factory Default)
Press
61 # Enables the Door Open Detection
Input
When enabled:
If the door is opened normally but not closed within 1 minute the buzzer will sound for 1 minute If the door is forced open (opened by an unauthorized user) the buzzer and alarm output will be activated
9 –
Security Mode Settings
for Invalid Ac
cess Attempts
(Can only be done in Master Programming Mode)
Three options are provided for programming Keypad Lockout / Alarm Output in the event that multiple invalid Access attempts are made. Programming any option will override all previous settings
Pr
ess 70 #
Normal Status
(No Alarm Output or Keypad Lockout)
(Factory Default)
When enabled, the number of keypad entries is unrestricted (no Alarm Output or Keypad lockout regardless of the number of invalid code entries)
When enabled, the Keypad will lockout for 10 minutes if there are 10 successive invalid card presentations or 10 successive incorrect PIN numbers entered within a 10 minute period
Press
72 # Alarm Output
Press
30 #
Press
31 #
Press
32 #
Press
71 # Keypad Lockout
Page 7
7
When enabled, the S2 Buzzer will sound and the Alarm Output will be activated if there are 10 successive invalid Card presentations or 10 successive incorrect PIN numbers entered within a 10 minute period
10 –
Site Code
Setting
(for Wiegand Output
) (Can only be done in Master Programming Mode)
When a valid User Code is entered the Wiegand Output will transmit the Site Code along with the 4 Digit PIN number entered as the Wiegand Card Number
Example - If the PIN used is 8888 and the Site Code is 029 then the full 8 digit, 26 Bit Wiegand number transmitted on the Wiegand Output is 029 08888
The default Site Code is 029 however an alternative Site Code may be programmed
Press
81 Enter Required Site Code (0
->255) #
Site Code must be between 0 and 255
11 – Setting the Address of the Reader
(Defaul
t 0) (Can only be done in Master Programming Mode)
When using S2 with security equipment that supports addressable readers such as Ness D8XD / 16XD Panels, Ness 6DA controllers etc it may be necessary to set the address of the reader
When programmed to Address 0 (Default) the Wiegand Output uses standard 26 Bit Wiegand protocol.
When set to address 1, 2 or 3 the Wiegand Output appends Ness encrypted protocols to S2’s address
0 - S2 Address 0 (Default) 1 - S2 Address 1 2 - S2 Address 2 3 - S2 Address 3
Press 82 Enter Address (0
->3) #
(Factory Default is
0 - Standar
d 26 Bit Wiegand
output
)
12 –
Alarm Output Time
(Default 1 Minute)
(Can only be done in Master Programming Mode)
This option sets the Alarm Output Time (duration) of S2’s Alarm Output
Press
9 Enter Alarm
Time in Minutes (1
->3) #
(Factory Default is
1 - 1 Minute)
Page 8
8
USER
SETTINGS
(User Settings can be programmed by the User at any time without entering Program Mode)
Assigning a PIN to a CARD
If the system is programmed for access is to be granted with “Card and PIN” (Programming Option 32 set) a PIN for each Card must be assigned using this option. (The Factory Default when cards are first programmed into the system is PIN 1234)
Press *
Present the Card
to the Reader
Enter Old PIN
(Default 1234)
#
Enter
NEW PIN
#
Repeat the
NEW PIN
#
Assigning a PIN to a ID Number
This option also assigns a PIN to a Card, but if the card is unavailable you can assign it to the User’s ID Number (Memory slot Number)
Press *
Enter the ID
Number the PIN
will be assigned to
#
Enter
Old PIN
#
Enter
New PIN
#
Repeat the
NEW PIN
#
OPERATION
Unlocking the Door By Card OR PIN .
If the Door Access Control Setting (Section 6) is programmed to “Card or PIN”, access will be granted by presenting a valid Card to the Reader or by entering a valid PIN
Either OR
If successful, the LED will flash Green and the Relay will activate for the Unlock time
If unsuccessful, the S2 will sound 3 Beeps and the likely cause will be a non valid Card (unprogrammed or
incorrectly programmed) or incorrect PIN entry (refer to Programming Section 3, “Adding Users”)
If a Card is presented and the LED glows steady S2 is waiting for a PIN to be entered. If this is not intended refer to Programming Section 6 “Door Access Control Settings” and select the correct Access Setting
Present Card to Reader
Enter 4 Digit PIN followed by
#
Page 9
9
Unlocking the Door By Card AND PIN
If Door Access Control is set to “Card” (Section 6), access will be granted by presenting a valid Card to the Reader. The LED will glow RED upon the presentation of the valid Card in readiness for a PIN entry within 5 seconds.
If the Card and PIN combination are both valid the LED will flash Green for the unlock time and the Relay will activate for the unlock period.
If no PIN is entered within 5 seconds S2 will time out and the LED will return to its normal red Flashing mode.
AND
S2 will sound 3 beeps if the entered PIN is invalid or incorrect
Resetting / Restoring an Alarm
If an Alarm occurs for any reason e.g. Door Forced Open or Open Too Long it can be reset by presenting A valid card to the Reader or by entering the Master Code
OR
Indicators / Warnings (LED and Buzzer)
Present Card to Reader
Enter 4 Digit PIN followed by #
Present
a Valid
Card to Reader
Enter
Master Code followed by
#
Page 10
10
Specifications
Features
Description
Appearance Metal case, anti-explosion and anti-tamper Waterproof
IP65
Input voltage
DC: 12-24V AC: 12-18V
Users(max)
2500
PIN
4 digits
Master Card Add/Delete User Proximity Reader (RFID)
Supports Wiegand 26bits, PIN/Wiegand output is a virtual number, Site
C
ode
/ Reader Address
is set within the
S2 C
ontroller
Connect External reader
Can Connect any External EM/HID/IC readers with Wiegand 26 bit Output
Connect High Power Alarm
External Current of the Alarm <=3A
Dimensions
135mm x 57mm x 25mm
Operating Voltage
DC:12~24V AC: 12~18V
Current
Idle – 35mA / Active <80mA
Card Reading Distance
3~6 cm
Operating Temperature
-40~60 Deg C
Lock Output Load
2A Max
Head Office:
4/167 Prospect Hwy,
Seven Hills NSW, Australia
Phone +61 2 8825 9222
email : ness@ness.com.au
Sydney Office - (02) 8825 9222
Melbourne Office -(03) 9875 6400
Brisbane Office - (07) 3399 4910
Perth Office -(08) 9328 2511
Adelaide Office - (08) 8152 0000
Email
customerservice@ness.com.au
Loading...