Ness L-8 User Manual

Page 1
L-8
CONTROL PANEL
USER MANUAL
Page 2
MANUFACTURED BY:
Sydney
(HEAD OFFICE)
4/167 Prospect Highway
Seven Hills 2147
N.S.W Australia
02 9624 3655
Brisbane
07 3343 7744
Melbourne
03 9878 1022
Perth
08 9328 2511
Copyright© by Ness Security Products
JULY 1997 V2.2
To the best of our knowledge, the information contained in this manual
is correct at the time of going to print. Ness Security Products reserve
the right to make changes to the features and specifications at any time and
without notice in the course of product development.
Page 3
PAGE CONTENTS
4
INTRODUCTION
5
Terminology
6
CONTROLS AND INDICATIONS
6
Keypad
6
Buttons
6
Audible Indications
7
Visual Indications
8
OPERATION
8
Operating Rules
8
Area Operation
9
Arming the Control Panel
10
Disarming the Control Panel
11
Monitor Mode
12
Emergency Functions-Panic
13
Alarms
13
Resetting an Alarm
14
Excluding Zones
15
Including Zones
16
Alarm Memory
17
PROGRAMMING
17
To Enter Program Mode
17
To Exit Program Mode
18
How To Program Access Codes
19
How To Program Entry and Exit Times
20
To Program Entry 1 Timer (option 26)
20
To Program Entry 2 Timer (option 27)
20
To Program Exit Timer (option 28)
21
Programming Summary
22
Troubleshooting
23
Installation Record
24
Operation Summary
3
Page 4
DETECTORS & SWITCHES
Zone 1 Front door
Zone 2 Windows
NESS L8 KEYPAD
Zone 3 Side door
Zone 4 Hallway
Zones5-7 Hallway
Zone 8 Garage
Internal siren
L8
ALARM SYSTEM
External siren
Strobe light
17V AC plug pack Optional keyswitch Optional Panic switch Siren cover with
tamper
( EXAMPLE OF A TYPICAL SYSTEM )
INTRODUCTION
Thank you for purchasing a Ness L8 control panel proudly designed and built in Australia. The L-8 control panel is very powerful but easy to use, utilising the latest in microprocessor technology. Please take time to read this manual so that you understand the benefits of the control panel.
4
Page 5
TERMINOLOGY
The micro computer based 8 zone control panel forms the heart of your security system
and connects to all other equipment. Each zone of the panel will be connected to one or more detection devices to protect an area such as the front door, hallway, windows, etc.
The panel is said to be armed when it is set to detect an intruder. At other times it is disarmed.
Normally a zone is considered secured. Activation of a detection device will cause the zone to be unsecured and may cause an alarm.
Detectors such as fire detectors and panic buttons must be able to generate an alarm at all times regardless of the panel setting. A zone with this assignment is called a 24 hour zone.
Some detection devices may only be required to generate an alarm or warning only when the panel is disarmed. A zone with this assign­ment is called a day zone.
Before leaving the premises you must arm the panel to enable it to detect intruders and generate an alarm. After arming, the panel will ignore detectors for the exit delay time to enable you to depart without triggering an alarm.
When you enter the premises the panel will ignore selected zones for the entry delay time and will not alarm unless you fail to disarm the panel during this allowed time.
Monitor mode allows selected zones to be armed while leaving others disarmed if you wish to protect a number of zones while you are at home.
If you wish to split your alarm system into two areas with access limited to each area by code numbers then area operation is used.
The control panel housing and the metal covers over external sirens are protected by tamper switches to detect someone attempt­ing to disable the security system. Activation of these switches will cause an instant tam- per alarm.
If a detector becomes faulty, you can exclude the associated zone so that it is totally ignored and cannot generate an alarm. Including the zone will enable it to generate an alarm again.
The control panel is fitted with a rechargeable stand-by battery to ensure your security sys­tem continues to operate if the mains power is interrupted. This battery is checked every hour and when ever you arm/disarm the panel.
When ever an alarm occurs, it may be silenced by entering an access code, otherwise it will reset at the end of alarm reset time. All alarms are stored in memory and may be viewed at any time by entering memory mode.
5
Page 6
CONTROLS AND INDICATIONS
KEYPAD
The L-8 keypad consists of 18 buttons, 17 indicators and 1 internal beeper.
BUTTONS
The 10 numeric buttons are used for enter­ing access codes and in program mode to enter option selections and values.
AUDIBLE INDICATIONS
Every time a button is pressed on the keypad,
it responds with a brief beep in acknowl­edgment.
The beeper is also used to indicate whether the entry was valid or invalid. For example, whenever enter is pressed, all the buttons
pressed before it are checked to see whether
they are valid. If they are valid, the response will be 3 short beeps.
If they are invalid (or incorrect) the response will be 1 long beep and they will be ignored.
At other times, the beeper will sound warnings such as 10 beeps for a low battery or mains fail.
The Enter button is used at the end of every button sequence to enter the button data.
..ENTER..
The beeper may have been programmed to sound continuously if an alarm has occurred.
6
10
Page 7
VISUAL INDICATIONS
Each of the 17 indicator lights have three possible states. These are:-
LIGHT
ZONEs 1 - 8
ARM 1
ARM 2
MAINS
BATTERY
MEMORY
EXCLUDE
TAMPER
PROGRAM
LINE
OFF
Zone Sealed
Day / Disarm
Day / Disarm
Normal
Normal
Normal
Normal
Normal
ON
Zone Unsealed
Panel is Armed
Panel is Armed
Normal
Normal
Memory Mode Selected
Exclude Mode Selected
Client Mode Selected
Panic Alarm has been activated. Only displayed in Memory.
FLASH
Zone Alarm
Monitor Mode
Monitor Mode
Mains Fail
Battery Low
Alarm in Memory
Zones Excluded
Tamper Alarm
Install Program Mode selected
7
Page 8
OPERATION
This section describes the operation of a typ­ical control panel installation. Keep in mind that your installation may vary depending on the selected options and equipment. The operating instructions which follow will endea­vour to cover the most common options. If you had any doubts speak to your installer.
All control panel operations are controlled by the L8 keypad except if an optional key switch or radio control is installed.
OPERATING RULES
Generally, the panel will be in the disarmed. Armed or monitor modes which provide different levels of security for your prem­ises. Three other temporary modes, program, memory and exclude, allow you to perform various operations. The panel will automati­cally exit from these temporary modes if you do not press any buttons on the keypad within a 4 minute period.
The L8 control panel allows for the 8 zones to be split into two groups known as area 1 and area 2.The two areas can be assigned access codes so that a user may have access either of the areas or both areas. This allows for people to have access to one part of your premises while the other part remains armed.
This is known as area operation. Arming and disarming is carried out as normal, you may have keypads installed in each area and set up by your installer so that the armed light indicates the armed state for that area only.
NOTE: All zones which are active in the
armed mode always exist in one or both areas, eg. even if you do not require your 8 zones to be split, all 8 zones will be programmed to operate in area 1.
If you make a mistake while entering any codes, press the enter button and start again.
When you are required to enter your access code, you are given three opportunities to enter it correctly. After the third invalid attempt the alarm is activated (requiring the correct code to silence the alarm). This prevents anyone trying to guess your code by enter­ing random numbers.
AREA OPERATION
8
Page 9
ARMING THE CONTROL PANEL
The control panel must be armed prior to vacating the premises in order to detect intruders. Ensure that the panel is not in Program, Memory or Exclude modes.
NOTE: If the panel is already in alarm,
you must first silence the alarm before you can arm.
These are two methods of arming the panel:
1. Normally the panel is armed by pressing
Arm then Enter.
2. Your installer may have programmed the
panel to require the entry of a code to arm the panel.
1. CHECK that all windows and doors are securely locked.
2. PRESS
code
or
Arm
Arm
..Enter..
..Enter..
3.
The arm light should be ON.
4. L E AVE the premises within your exit delay time.
5. At the end of the exit delay time, three beeps will sound
If something is wrong when Arming the control panel, the normal 3 beeps will be replaced by other warnings.
• Mains power is turned off
• Control Panel battery is low
• A long beep indicates an invalid entry
or an alarm is outstanding and needs
to be reset by entering your access
code first.
Siren Warning: At the end of the exit time, all zones should be secured. If any are unse­cured, the siren will sound for 2 seconds as a warning to indicate that those zones have been automatically excluded. For maximum security, you should return, disarm, check the premises and then arm again. Continual warnings could mean that a detector is faulty and may have to be manually excluded.
If the auto-exclude option is disabled, the siren will sound for the duration of reset time if a zone is unsecured at the end of exit time.
9
Page 10
DISARMING THE CONTROL PANEL
Upon entering the protected premises through a delay zone, the keypad responds with regular beeps as a reminder to disarm. You then have your programmed entry delay time to disarm the panel by, Entering one of your access codes. If the panel is not dis­armed by the end of the entry delay time, an alarm will occur. You may enter your code to silence the alarm.
If one of your codes is, say, 7676 then to disarm press…
7676 enter
If you make a mistake in entering your code, then you must press enter and start again. Three incorrect entries will cause an alarm.
1.
ENTER the protected premises via a delay zone.
2. LISTEN for the beeps coming from the keypad.
3. PRESS . . . code
..Enter..
4. The armed light should now be extinguished..
The entry beeps can be disabled as a function of the installation options.
If the external strobe light (if fitted) is flashing before you disarm then this means that an alarm occurred since you last armed the panel. Flashing indicators on the keypad also indi­cate the location of the alarm before you disarm. Once you have disarmed, you may view the alarm memory to check the location of the alarm. (See alarm memory page 16)
10
Page 11
MONITOR MODE
Monitor mode allows you to arm selected zones while others are ignored. Typically, perimeter zones (doors and windows) can be monitored while you are at home.
To select Monitor mode,
A) press <Monitor> <Enter> or
<Monitor> <code> <Enter>
The control panel will respond with 3 beeps and the armed indicators will flash to indicate that you are in Monitor mode.
1. To ENTER monitor mode, press…
Monitor mode cannot be selected while in Program, Memory or Exclude modes.
To exit from Monitor mode: press, <code> < Enter> to disarm.
Note:
If an alarm occurs, while in Monitor mode, entering <code> <Enter> will silence the alarm. This will also change the mode of operations of your panel, so remember to enter monitor mode again if necessary.
Monitor ..Enter..
2. If an ALARM occurs, the respective zone light will flash
3. To SILENCE the alarm
and to exit monitor, press… code
11
..Enter..
Page 12
EMERGENCY FUNCTIONS-PANIC
For personal protection, the keypad contains an instant panic feature. Panic can be used to…
or outside your premises.
Scare away intruders inside
Summon help from friends
or neighbours.
Test the operation of the siren.
The panic function may have been programmed to be either.
1. PANIC!
2. Press…
Panic
3.
The siren will SOUND
1 / Audible - activates siren or buzzers
or
2 / Silent - activate a warning in another part of your building.
To activate the panic alarm, press <Panic> <Enter> To silence the siren, press <code> <Enter>
Panic cannot be used while the panel is in Program, Memory or Exclude mode.
NOTE: Your installer may have installed
a separate panic button. To activate the panic alarm simply press the button.
..Enter..
4. Press… code
The siren will S T O P
..Enter..
12
Page 13
ALARMS
Alarms may be caused by one of the follow­ing:
A zone has been activated while armed
A tamper has been activated
A Panic button has been activated
Memory plus indicates CAUSE
RESETTING AN ALARM
Your panel can be reset and the alarm silenced by entering your CODE followed by the ENTER button.
All of these may cause your sirens and strobe to operate. Various visual indications relevant to the alarm will be retained in the memory. If this occurs, disarm your Control Panel which will reset the alarm. The cause of the alarm can be identified by entering the Alarm Memory Mode as described on page 16.
If you arrive at your premises and find the strobe light flashing (if installed), reset the panel as above. To check the cause of the alarm, you can view the alarms in memory by entering memory mode.
To Reset an alarm, press … code
..Enter..
13
Page 14
EXCLUDING ZONES
If a detector becomes faulty and cannot be secured when arming the panel, then its zone may be excluded, ie.ignored by the system so that it does not generate false alarms.
To enter Exclude mode press,
<Exclude> <Enter>
or
<Exclude> <code> <Enter>
1. To exclude zones…
2. Press…
code
the Exclude light should be On
or
Exclude
All the lights will be turned off and then the Zone Excluded light will show a steady light. You may now exclude zones.
To exclude, say, zones 4 and 8, press the buttons… <Exclude> <Enter>
4 <Enter> 8 <Enter>
Zone lights 4 and 8 will turn on.
<Enter> to Exit Exclude Mode
NOTE: Excluding zones can only be done when the panel is disarmed.
..Enter..
..Enter..Exclude
3. ENTER the zone/s to be EXCLUDED Zone No.
4. To EXIT press ENTER
If you make a mistake, enter the zone number again to remove it from your selection.
Zones which you exclude will be indicated by the relevant zone light showing a steady light in the exclude mode.
NOTE: Your Control Panel may be programmed to automatically exclude faulty zones whenever you Arm. The Exclude light will flash as a warning or memory of the auto-exclusion. If Auto - Exclude is selected the outside Siren will sound for 2 seconds indicating a zone has Auto Excluded.
..Enter..
14
..Enter..
Page 15
INCLUDING ZONES
Zones which have been excluded, may be included while you are in the Disarm modes.
All Excluded Zones are automatically included when the panel is Disarmed. Thus if a detector is still faulty it must be Excluded again.
The exclude light will flash to warn you of excluded zones.
To view Exclude Zones for Inclusion press,
<Exclude> <Enter>
or
<Exclude> <code> <Enter>
To include, say, zones 4 and 8, press
<Exclude> <Enter> <4> <Enter> <8> <Enter>
Zone lights 4 and 8 will turn off.
<Enter> to Exit Exclude Mode
1.
code
the Exclude light should be On
To include zones, press …
or
Exclude
..Enter..
..Enter..Exclude
2. ENTER the zone/s to be EXCLUDED Zone No.
..Enter..
3. To EXIT press ENTER
..Enter..
15
Page 16
ALARM MEMORY
The L8 Control Panel contains an compre­hensive Alarm Memory. The L8 will remem­ber Arms, low battery, mains fail and alarms. The memory is constantly upgraded and the last 8 events are always available for viewing.
To view the memory display, enter…
<Memory> <Enter>
or
<Memory> <code> <Enter>
The memory light will illuminate and then the last 8 alarm events will be flashed out at 1 second intervals. A short beep indicates the next event is displayed.
NOTE: The most recent of the last 8 events will be displayed first.
This Memory display can only be selected while the panel is in the Disarmed state.
NOTE: Entry to Program Mode will clear the events from Alarm Memory.
1. To view memory , press…
2.
The last 8 events will be flashed out at 1 second intervals separated by a beep
The lights are used as follows:
LIGHT ALARM
Zone light Zone alarm
Arm light Panel armed
Tamper light Tamper alarm (siren cover, panel etc.)
Line light Panic alarm
Battery light Low battery
Mains light Mains failure
OBSERVE lights .
Memory
..Enter..
You can access the Alarm Memory as often as required while the Panel remains Disarmed .
16
Page 17
PROGRAMMING
The L8 Control Panel allows you to reprogram all 15 available access codes, the 2 entry times and your exit time.
You may need to reprogram an access code because you no longer wish a user to have access to your system or because you want to give somebody temporary access to your system, or you may have simply forgotten your code.
You may also need to reprogram the entry or exit times of your entry/exit zones if you find them too long or too short.
For all other programming changes, talk to your installer.
TO ENTER PROGRAM MODE
Access code number 1 is called your master code. Program mode can only be accessed
using your master code. To enter program mode, press…
<Program> <master code> <Enter>
Important: The control panel will automatically exit the Program mode if no keys are pressed within a
four minute period.
The program light will turn on and all other lights will turn off to indicate successful access to program mode.
NOTE: Access to Program mode can only be done from the disarmed state.
To enter Program mode, press…
Program
Master Code
..Enter..
TO EXIT PROGRAM MODE
Press, <Program> <Enter>
The program light will turn off and normal operating lights
Important: The control panel will automatically exit the Program mode if no keys are pressed within a
four minute period.
(mains and battery will turn on).
NOTE: The control panel will automati­cally exit the program mode if no buttons are pressed within a 4 minute period.
To exit Program mode, press…
Program
17
..Enter..
Page 18
HOW TO PROGRAM ACCESS CODES
To program any of the 15 access codes, you must know a few rules first.
REMEMBER :-
All codes can be 3, 4, 5 or 6 digits long
Codes cannot begin with a 0 (see below)
A code can be cancelled by reprogram-
ming it again with a code of 000.
Codes must be unique and cannot be a
subset of each other. Eg. If a Code-2 is 1234,code-3 234 (not allowed) code-6 1334 (allowed).
Code-1 is the master code and MUST be
programmed. All other codes are optional
To Program Codes, press…
When you enter your new code number the L-8 requires that you input the code twice to confirm a correct code.
Each user access code has a 2 digit program option number to ensure the panel can identify which code number you want to program.
The options for each code are:­Code Option Code Option
1 11 9 19 2 12 10 20 3 13 11 21 4 14 12 22 5 15 13 23 6 16 14 24 7 17 15 25 8 18
2 digit option no.
Code no code no.
A long beep indicates an error has been made-start again.
Example to program code 1 to be 2468. Prog 11 enter 2468 Enter 2468 Enter
Program
..Enter..
..Enter.. ..Enter..
18
Page 19
HOW TO PROGRAM ENTRY AND EXIT TIMES
Your L-8 Control Panel will have zone(s) which are called Entry/Exit zones. These are the zone(s) which you normally enter and leave your premises by. To allow you to do so without causing a false alarm, there is an Exit Time which the Control Panel gives you to depart your premises after you Arm the Panel. There are 2 separate entry times which the Control Panel gives you to Disarm the Panel when you have entered the prem­ises before an alarm occurs.
Your installer may have programmed differ­ent zones with a long entry time and a short entry time zone. (A long and short entry time is useful if you enter by a garage or a front door).
TO PROGRAM YOU MUST KNOW A FEW RULES:
Exit time can be programmed from 1 to 99 seconds in 1 second increments.
Entry 1 time can be programmed from 1 to 99 seconds in 1 second increments.
Entry 2 time can be programmed from 10 to 990 seconds in 10 second increments, Each one of the timers has a 2 digit program option number.
The current timer value is displayed by the L-8 when you select a timer option. The value is displayed by flashing out the value on the numeric zone lights 1 to 8, 9= battery and 0= mains at 1 second intervals.
When you change the timer value the new value is displayed as above. The option numbers are as follows;
Entry 1 timer = Option 26 Entry 2 timer = Option 27 Exit time = Option 28
Programming always follows this sequence;
To view a timer, press…
2 digit option
To change a timer , press…
New Value New Value Displayed
Program
..Enter..
..Enter..
19
Value displayed
Page 20
TO PROGRAM ENTRY 1 TIMER (OPTION 26)
Timer 1 can be set from 1 to 99 seconds. Default time equals 20 seconds.
To view entry 1 timer value, press value displayed
OPTION 26
To change entry 1 timer, press… New Value displayed.
New value
Timer 2 can be set from10 to 990 seconds in 10 second increments.
To view entry 2 timer value, press value displayed
OPTION 27
To change entry 2 timer, press… New Value displayed.
New value
Default time equals 60 seconds.
Timer can be set from 1 to 99 seconds. Default equals 60 seconds. Exit timer is common to all armed zones.
Program
..Enter..
TO PROGRAM ENTRY 2 TIMER (OPTION 27)
Program
..Enter..
TO PROGRAM EXIT TIMER (OPTION 28)
..Enter..
..Enter..
To view exit timer value, press value displayed
OPTION 28
To change exit timer, press… New Value displayed.
New value
NOTE: Your installer may have programmed your exit timer to be programmable from 10 to 990 seconds in 10 second intervals
if you require a particularly long exit time. (Eg.,time to arm, move your car from the garage and close the door.) Simply program
your exit time as normal. It is recommended that for maximum security you should keep your exit and entry times as short as possible.
Program
..Enter..
..Enter..
Page 21
PROGRAMMING SUMMARY
OPTION CODE DEFAULT PROGRAMMED
Access code 1 (MASTER) P11E code E code E
Access code 2 P12E code E code E
Access code 3 P13E code E code E
Access code 4 P14E code E code E
Access code 5 P15E code E code E
Access code 6 P16E code E code E
Access code 7 P17E code E code E
Access code 8 P18E code E code E
Access code 9 P19E code E code E
Access code 10 P20E code E code E
Access code 11 P21E code E code E
Access code 12 P22E code E code E
Access code 13 P23E code E code E
Access code 14 P24E code E code E
Access code 15 P25E code E code E
Entry 1 time P26E time E 20 seconds (1-99)
Entry 2 time P27E time E 60 seconds (10-990)
Exit time P28E time E 60 seconds (1-99)
21
Page 22
TROUBLESHOOTING
SYMPTOM POSSIBLE CAUSE REMEDY
Zone light on or long Zone detection device (eg. Close door or window. beeps on arming reed switch, movement Find cause of movement detector) unsecured.
10 beeps upon Arming. Mains power off. Battery low. Check plugpack is Mains light flashing- plugged in and Battery light flashing. power point on or Call installation company.
10 beeps at any time (as above) (as above) (mains/battery light flashing)
1 long beep during Invalid keypad entry Press enter button & keypad entry. re-enter
2 second siren at end Zone unsecured on Re-enter premises, disarm of exit time. expiry of exit time system, check zone isolate memory to determine zone at fault.
External strobe light Alarm occurrence since Check alarm memory to flashing. last arming of panel. determine zone alarmed.
Siren sounding when Tamper, panic or 24 hour Reset alarm by entering system disarmed. zone, or day zone activated. code. Check panic buttons (if Installed)-or call installation company.
Armed/ monitor light Monitor mode entered Exit monitor mode. flashing by mistake.
Zone excluded light A zone has been excluded. Check zone excluded flashing memory. Arm panel with all zones secured.
Tamper light flashing Tamper unsecured Call installation company
Alarm memory light Alarm in memory. Check alarm memory to see flashing. cause of alarm.
Cannot access program -Panel armed -Disarm panel first before mode. -Not using master code. entering code.
-To enter program mode press
Prog-Master code-Enter (see page 17)
22
Page 23
INSTALLATION RECORD
Supplied by:
Phone number: Phone number:
Installed by: Date:
Optional equipment installed:
Serviced by Date Reason
23
Page 24
OPERATION SUMMARY
To arm <optional code>
To disarm or Reset Alarm <code>
To monitor zones <optional code>
To exit monitor mode <code>
To exclude zones <optional code>
then <zone> <zone> etc.
To exit exclude mode
To include zones <optional code>
then <zone> <zone> etc.
Arm
.. Enter ..
Monitor
.. Enter ..
.. Exclude ..
.. Enter ..
.. Enter ..
.. Exclude ..
.. Enter ..
.. Enter ..
.. Enter ..
.. Enter ..
.. Enter ..
.. Enter ..
.. Enter ..
To exit include mode
Panic alarm
To Reset Alarm <code>
To view memory <optional code>
.. Enter ..
Panic
Memory
.. Enter ..
.. Enter ..
The last 8 events will be displayed at 1 second intervals.
PART NO. 890-131
24
.. Enter ..