31
A Duress Alarm can be activated by Adding a 5, 6, 8 or 9
digit before your Access code.
(ie. If your access code is 3 6 2 2 , then adding a 5, 6, 8,
or 9 before the code eg. code 9 3 6 2 2 will disarm the
panel and generate a Duress alarm.)
This option ,when selected, will activate the Reset output
whenever a Duress Code is used.
PROGRAMMING OPTION DESCRIPTIONS
P 60 E 5E DURE SS ALARM TO ACTIVATE ‘ RESET’ OUTPUT
To Select this option Enter P 60 E 5 E .
Zone LED 5 will be on when this option is selected and
off when it is disabled.
Factory Pre-Set = No Reset Output Selected on
Duress Alarm. (ie. Zone LED 5 Off)
If a Zone is unsealed at the end of Exit Time (as set by P 28
E) the Ness D-8 will provide a 2 Second Siren Burst and the
Zone unsealed will be automatically excluded (not cause
an Alarm) from the System until it is sealed again or until
the panel is disarmed. The 2 second Siren Burst can be
disabled when Auto-excluding by Selecting P 62 E 7 E
This option will Disable the Auto-Exclude function. When
disabled, a Zone unsealed at the end of exit time will cause
the panel to go into Alarm and not automatically Exclude
the Zone.
P 60 E 6E AUTO E XCLUDING OF ZONES
To Disable this Auto Exclude function, enter; P 60 E 6 E
The Zone 6 LED will indicate if the option is selected.
With Zone 6 LED On, the Auto Exclude function is
Enabled and with the Zone 6 LED Off the Auto Exclude
function is disabled.
Factory Pre-Set = Auto Exclude Enabled
(ie. Zone 6 LED On)
This option , when selected , will turn off all LED indicators
on the Keypad if no keypresses have occurred
within 4 minutes (useful to stop annoying lights in a bedro o m ) .
Any activation of the keypad via Beeps or pressing of any
key will restore the LED's.
P 60 E 7E DISABLE TH E DISPLAY
To Enable this Display Disable function, enter; P 60 E 7 E
The Zone 7 LED will indicate if the option is selected.
With Zone 7 LED On , The Display Disable function is
Enabled and with the Zone 7 LED Off the Display
Disable is disabled.
Factory Pre-Set = No Disabling of LED's
(ie. Zone 7 LED Off)
The outputs marked Area 1 turns on immediately Area 1
is Armed.
This programming option, when selected, will turn Area 1
output on only after exit time has expired.
To Enable these outputs to activate only after Exit time,
enter; P 60 E 8 E
P 6 0 E 8E AREA 1 & A REA 2 OUTPUT O N AFTER EXIT TIME
The Zone 8 LED will indicate if this option is selected.
With Zone 8 LED On, The Area 1 Output will active at
the end of Exit time when the Area is Armed, and with
the Zone 8 LED Off , the Output will activate immedi-
ately the Area is Armed.
NOTE: This option also controls the output for area 2.
Factory Pre-Set = Outputs Activate Immediately Area
is Armed. (ie. Zone 8 LED Off)