Ness D24 User Manual

D24
USER’S MANUAL
A$15.00
INC GST
Ness D24 control panel – User’s manual
Revision
2
HEAD OFFICE:
Ness Security Products Pty Ltd ACN 069 984 372 4 / 167 Prospect Hwy Seven Hills NSW 2147 Australia Ph +61 2 8825 9222 Fax +61 2 9674 2520 ness@ness.com.au
SYDNEY 02 8825 9222
MELBOURNE 03 9878 1022
BRISBANE 07 3343 7744
ADELAIDE (Aquavia Controls) 08 8277 7255
PERTH 08 9328 2511
NEW ZEALAND (NFS NZ) +64 9 573 0401
“Australia’s largest
designer and
manufacturer of
high quality security
products”
WWW.NESS.COM.AU
Ness Security Products Pty Ltd
Quality Endorsed Company ISO9001
LIC.No. QEC2074 NSW Head Office only
D24 USER MANUAL REVISION 2 November 2002
Document Part Number: 890-252 For product: 100-660 D24 Control Panel
© 2002 Ness Security Products Pty Ltd ABN 28 069 984 372 D24user rev2 pmo131102
Specifications may change without notice.
NESS SECURITY PRODUCTS
TELECOMMUNICATIONS COMPLIANCE
Australian Communications Authority
CONTENTS
Features ................................................................................. 4
Keypad ................................................................................. 5
Keypad Display Table .......................................................... 6
View Menu Operation ........................................................... 7
OPERATION ......................................................................... 8
Arming ............................................................................... 9
Disarming .......................................................................... 9
AREA Operation .............................................................. 10
Arming & Disarming Areas ............................................ 11
Administrator Code ........................................................ 12
Monitor Mode .................................................................. 13
Panic Alarm ..................................................................... 14
Duress Alarm ................................................................... 14
Medical Alarm ................................................................. 15
Fire Alarm ........................................................................ 15
VIEW Menu ...................................................................... 16
VIEW Memory ................................................................. 17
Excluding Zones ............................................................. 19
Test Mode ........................................................................ 20
Siren Test ......................................................................... 21
PROGRAMMING
Programming Options Table ......................................... 21
How to Program .............................................................. 22
User Code programming .......................................... 22-23
Entry/Exit Timer programming ...................................... 24
Wireless Accessories .......................................................... 25
Installation Record .............................................................. 26
Operation Summary ........................................................... 27
NESS D24 CONTROL PANEL - USER MANUAL
4
Pow erful multizone commercial security
24 fully programmable zones
Supports 8 Radio Devices (Radio PIRs, Radio Reeds etc)
Supports 8 Radio Keys
Contact ID Dialler Format
Ness Audible Dialler Format
Separate 24 Hour Tamper input
Single or Double Trigger Zones
Remote LCD Keypads (Max 3)
Fully programmable via the system Keypad - Eliminates the need f or expensive prog rammers or Proms.
Inbuilt Vibration Sensor Analyser
All programming data is permanently stored in a non-volatile EEprom memory
True Dynamic Battery Test e v ery time the Panel is Armed / Disarmed and every hour
Area Partitionable (3 Areas). An y Zone can be programmed to any area, as well as common areas
Comes complete with an AC plug pac k and supports a 12V 7Ah battery to maintain system security under all power supply conditions
T w o separate Monitor Modes (Home Mode)
Outputs are separately fused with Automatic Reset Fuses
Day Mode and Door Chime feature .
30 Event Memory
All inputs and outputs are heavily protected against lightning and high voltage supply transients. An earth terminal is provided for extra protec­tion
30 User Codes
Programmable Inputs to activ ate selectable Outputs (Output Mapping)
Manufactured with the latest SMD Technology
Ultra-Modern and Impact resistant Housing
Forced Arming Feature
NESS D24 FEATURES
NESS D24 CONTROL PANEL - USER MANUAL
5
D24 KEYPAD
2
5
8
0
1
4
7
P
3
6
9
E
E
ARM
VIEW
D24
MONITOR
EXCLUDE
PROGRAM BUTTON ENTER BUTTON
KEYPAD DISPLAY TEST:
Press and hold button.
PANIC BUTTON (Press & Hold)
BACKLIT LCD ICON DISPLAY
TM
F
MONITOR
ARM ZONE TAMPER SYSTEM POWER FIRE MEMORY
AREA 1 AREA 2 AREA 3 EXCLUDE PROGRAM TEST
20
12 13
21
4
10 119
191817
312
1614 15 2422 23
6578
AREA
NESS D24 CONTROL PANEL - USER MANUAL
6
KEYPAD DISPLAY TABLE
OFF ON
Flashing
FAST
Flashing
SLOW
ZONES
Zone sealed Zone unsealed
Zone Alarms present (in Armed or Monitor Mode)
ARM
Panel is Disarmed
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Panel is Armed
ZONE
Displaying Zone Status
TAMPER
Displaying individual Tamper Alarms
Tamper Alarms present
SYSTEM
Displaying individual System Alarms
System Alarms present
POWER
Displaying individual Power Alarms
Power Alarms present
FIRE
Fire warning (If enabled)
Fire alarm (If enabled)
MEMORY
Memory Mode
or View key pressed
New alarm in Memory
MONITOR
Panel is in Monitor Mode
AREA 1
Area 1 Armed Area 1 Monitor
AREA 2
Area 2 Armed Area 2 Monitor
AREA 3
Area 3 Armed
EXCLUDE
Exclude Mode Zone or other
alarm Excluded
PROGRAM
User Program Mode
TEST
Siren Test
T
M
F
1-24
NESS D24 CONTROL PANEL - USER MANUAL
7
VIEW MENU OPERATION
MEMORY icon flashes to indicate that Memory contains new events. Memory can be viewed at any time.
E
M
TAMPER ALARMS
1 External Tamper 2 3 5
Control Panel Tamper Zone input Tamper Radio Interface Tamper
SYSTEM ALARMS
1 2 3 4 5 6 7 8 9
Keyswitch Panic Dialler line fault Keypad connection fault Control Panel fault Duress alarm Panic alarm Medical alarm User Code alarm Access to Installer Program mode
POWER ALARMS
1 2 3 4 9
0
Mains power failure Backup Battery low DC supply failed Zone reference supply failed Radio Device battery low
Radio Key battery low
(1-8 shows which device has low battery)
(1-8 shows which device has low battery)
1. Press
2.
3.
Memory icon turns on
Keypad icons will display the most recent event as per the Keypad Display Table
Press to cancel the Memory display at any time
To view
alarms
TAMPER
To view
alarms
SYSTEM
To view
alarms
POWER
To view
MEMORY
4
VIEW
3
VIEW
2
VIEW
VIEW
VIEW
Step through the Memory display by pressing the
button. At each step, the keypad icons display the history of Arming, Disarming and alarm events.
VIEW
MEMORY DISPLAY
E
E
E
E
E
NESS D24 CONTROL PANEL - USER MANUAL
8
OPERATION
ARMING AND DISARMING
The Ness D24 micro computer based 24 zone control panel is the heart of your security system to which all your detection devices connect.
Each Zone of the panel can be connected to one or more detection devices to protect separate rooms of your premises.
Detection devices may be connected to the D24 control system directly by cabling or with optional wireless (Radio) devices.
The most common type of detection devices are Passive Infra-Red Motion Detectors (or P.I.R’s for short) and Reed Switches for doors and windows.
OPERATING MODES
The Ness D24 will operate in one of the following modes:
ARMED: The system is “On” and ready to detect intrusion. 24 Hour Zones (if configured) are still active. Area Partitioning means the panel can be split into three separate “Areas” which can be Armed and Disarmed independently of each other.
DISARMED: The system is “Off”. This is the normal mode when the premises are occupied. Day Zones and 24 Hour Zones (if configured) are still active.
DAY Mode: The system is Disarmed and a zone or zones have been setup to create an alarm when activated. Often used as a doorway alert in a shop.
MONITOR Mode: Allows the system to be “partially” Armed. For example, in a house, to allow all perimeter zones, doors and windows, to be Monitored (armed) at night.
24HR Zones: Zones that have been setup to be active in any mode. Usually used for Tamper switches and Panic buttons.
NESS D24 CONTROL PANEL - USER MANUAL
9
ARMING & DISARMING
The control panel must be Armed prior to vacating the premises in order to detect intruders. Ensure that the panel is not in Program, Memory or Exclude modes.
Note: If the panel is already in alarm, you must first silence the alarm before you can Arm.
SIREN WARNING:
At the end of the exit time, all zones should be Sealed. If any are Unsealed, the siren will sound for 2 seconds as a warning to indicate that those
ARMING THE SYSTEM
If the D24 has not been programmed for Area operation, this method will Arm the entire system.
Press... (If Two Button Keypad Operation is disabled. This is the factory default.)
...or (If Two Button Keypad Operation is enabled.)
...or [CODE] (If Shortcut Arming is disabled.)
Three beeps will sound and the ARM icon will turn ON
ARM
Leave the premises within the Exit Delay Time. At the end of Exit Delay Time, 1 beep will sound
zones have been automatically excluded. For maximum security, you should return, Disarm, check the premises and then Arm again. Continual warnings could mean that a detector is faulty and may have to be manually excluded.
AUTO EXCLUDE:
If the auto-exclude option is disabled, the siren will sound for the duration of reset time if a zone is Unsealed at the end of exit time.
DISARMING THE SYSTEM
If the D24 has not been programmed for Area operation, this method will Disarm the entire system.
Press... [CODE]
Three beeps will sound and the ARM icon will turn OFF
ARM
Disarm the panel during the Entry Delay Time to prevent unwanted “Alarm on entry”. An error beep when attempting to Disarm may indicate:
Incorrect Code or the panel is already Disarmed or the panel is in Exclude mode
See Page 12 for Disarming Areas