Ness 101-091, 101-091B, XK Installation Manual

Page 1
101-091 / 101-091B
Ultraprox Bluetooth Keypad/Reader
INSTALLATION & USER MANUAL
Innovative Electronic Solutions
Rev 1.0
Page 2
CONTENTS
INTRODUCTION…………………..................................................................................…………………1
INSTALLATION…………………………..................................................................................……………3
STANDALONEMODE……....................................................................................………………………5
CONTROLLERMODE……….................................................................................………………………11 
WIEGANDREADERMODE……....................................................................................………………13
ADVANCEDAPPLICATION…………..............................................................................……………..15
Page 3
INTRODUCTION
The XK Series device is a single door multifunction standalone access controller or a Wiegand output reader. It uses Atmel MCU assuring stable performance. The operation is very user-friendly, and low-po wer circuit makes it long service life.
The XK Series device supports 1,000 users (998 common users + 2 panic users), all user data can be transferred from one to another. It supports multi access modes in either card access, PIN access, Card + PIN access, or multi cards/PINs access. It has extra features including block enrollment, interlocked, Wiegand 26~37 bits interface, etc th at are highlighter below.
Features
Bluetooth Module, to connect mobile App for opening door Fashion design, all-metal key button Metal Case, Anti-vandal Waterproof, conforms to IP66 One relay, 1,000 users (998 common users + 2 panic users) PIN length: 4~6 digits Card type:
EM version: 125KHz EM card
Wiegand 26~37 bits input & output Can be used as Wiegand reader with LED & Buzzer output Card block enrolment Tri-colour LED status display Integrated alarm & buzzer output Pulse mode or Toggle mode User data can be transferred 2 devices can be interlocked for 2 doors Built in light dependent resistor (LDR) for anti tamper Backlit keypad Low temperature resistance (-40℃) Voltage: 12~28V AC/DC
Page 4
Specifications
User Capacity
Common User Panic User
Operating Voltage
Idle Current
Proximity Card Reader
Radio Technology Read Range
Wiring Connections Relay Output, Exit Button, Alarm, Door Contact,
Relay
Adjustable Relay Output Time Lock Output Load
Wiegand Interface
Wiegand Input Wiegand Output Pin Output
Environment
Operating Temperature Operating Humidity
Physical
Colour Dimensions
Unit Weight Shipping Weight
1000
998 2
12~28V AC/DC
35mA
EM Format
125KHz Proximity Card 2~6 cm
Wiegand Input, Wiegand Output
One (NO, NC, Common)
0~99 Seconds (5 seconds default) 2 Amp Maximum
Wiegand 26-37 bits
(Factory Default: Wiegand 26bits, 4 bits) 26-37 bits 26-37 bits 4 bits, 8 bits(ASCII), 10 digits Virtual Num ber (Note: Set in the factory as 26 Bit Wiegand 10 Digit Virtual No. If a factory reset is performed onsite then these settings need to be manually reset.)
Meets IP66
-40 ~ 60 (-40~ 140) 0%RH~98%RH
Zinc-Alloy
Silver L114.5 x W75 x D22mm(XK3) L134 x W55.5 x D21mm (XK4) 340g 420g
Page 5
Carton Inventory
INSTALLATION
Remove the back cover from the unit Drill 2 holes(A,C) on the wall for the screws and one hole for the cable Knock the supplied rubber bungs to the screw holes(A,C) Fix the back cover firmly on the wall with 4 flat head screws Thread the cable through the cable hole(B) Attach the unit to the back cover
Wiring
Wire Color Function Notes
Basic Standalone Wiring Red AC/DC 12-28V AC/DC Regulated Power Input Black AC/DC 12-28V AC/DC Regulated Power Input Pink GND Negative Pole Blue Relay NO Normally Open Relay Output (install diode provided) Purple Relay Common Common Connection for Relay Output Orange Relay NC Normally Closed Relay Output (Install diode provided) Yellow OPEN Request to Exit(REX) Input Pass-Through Wiring (Wiegand Reade r or Controller) Green Data 0 Wiegand Input /Output Data 0 White Data 1 Wiegand Input /Output Data 1 Advanced Input and Output Features Grey Alarm Output Negative contact for Alarm Brown Contact Input Door/Gate Contact Input (Normally Closed)
Page 6
Sound and Light Indication
Operation Status LED Buzzer
Stand by Red light bright ­Enter into programming mode Green light Flashes on, then
RED Light flashes. In the programming mode Orange light bright One beep Operation error - Three beeps Exit from the programming mode Red light bright One beep Open lock Green light bright One beep Alarm Red light Shines quickly Beeps
One beep
Basic Configure
Enter and Exit Program mode
Programming Step Keystroke Combination
Enter Program Mode
Exit Program Mode *
Set Master Code
Programming Step Keystroke Combination
1. Enter Program Mode
2. Update Master Code
3. Exit Program Mode *
Set the Working Mode
Notes: the XK Series device has 3 working modes: Standalone Mode, Controller Mode, Wiegand Reader Mode, choose the mode you use. (Factory default is Standalone Mode / Contro ller Mode)
Programming Step Keystroke Combination
1. Enter Program Mode
2. Standalone/Controller Mode
OR
2. Wiegand Reader Mode
3. Exit *
* (Master Code) #
(Factory default is 123456)
* (Master Code) # 0New Master Code#Repeat New Master Code#
(Master code is any 6 digits)
* (Master Code) # 7 2 # (Factory default)
7 3 # (Pre-Set in the factory after a ‘Factory default’)
Page 7
STANDALONE MODE
The XK Series device can be worked as Standalone Reader for single door. (Factory default mode)---7 2 #
Connection Diagram
Attention:
Install a 1N4004 or equivalent diode is needed when using a common power supply, or the keypad might be damaged. (1N4004 is included in the packing)
Page 8
Programming
Programming will vary depending on access configuration. Follow the instructions according to your access configuration.
Notes: User ID number: Assign a user ID to the access card / PIN in order to track it. The common user ID number can
be any number from 0~997, the panic user ID is from 998~999. IMPORTANT: User IDs do not have to be proceeded with any leading zeros. Recording of User ID is critical. Modifications to the user require the User ID be available.
Proximity Card:
EM version: 125KHz industry standard 26bits EM card
PIN: Can be any 4~6 digits except 8888 which is reserved.
Add Common Users
Programming Step Keystroke Combination
1. Enter Program Mode
Add Card User
2. Add Card: Using Auto ID
(Allows XK Series device to assign Card to
next available User ID number)
OR
2. Add Card: Select Specific ID
(Allows Master to define a specific User ID to associate the card to)
OR
2. Add Card: by Card Number
OR
2. Add Card: Block Enrolment (Allows Master to add up to 998 cards to the
Reader in a single step) Takes 2 minutes to program.
Add PIN User
2. Add PIN: Using Auto ID
(Allows XK Series device to assign PIN to next
available User ID number)
2. Add PIN: Select Specific ID
(Allows manager to define a specific User ID to associate the PIN to)
3. Exit *
* (Master Code) #
1 (Read Card) #
The cards can be added continuously.
1 (User ID) # (Read Card) #
(User ID is any number from 0-997)
1 (Input 8/10 digits Card number) #
1 ( User ID) # (Card quantity) # (The first
card number) #
Cards’ number must be consecutive; Card quantity = number of cards to be enrolled.
1 (PIN ) #
The PINs can be added continuou sly.
(PIN: 4~6 digits)
1 (User ID) # (PIN ) #
The user ID is any number from 0-997.
Page 9
Add Panic Users
Programming Step Keystroke Combination
1. Enter Program Mode
2. Add Card:
OR
2. Add PIN:
3. Exit *
* (Master Code) #
1 (User ID) # (Read Card / Input 8/10 digits
Card number) #
1 (User ID) # (PIN ) #
(User ID is any number from 998-999)
Change PIN Users
Programming Step Keystroke Combination
Note: Below is done outside programming mode, users can undertake this themselves
2. Change PIN: By Card (There will auto allocate PIN(8888) to cards when adding)
2. Change PIN: By PIN
3. Exit
* (Read Card) (Old PIN) # (New PIN) #
(Repeat New PIN) #
* (User ID) # (Old PIN) # (New PIN) # (Repeat
New PIN) #
Delete Users
Programming Step Keystroke Combination
1. Enter Program Mode
Delete Card User - Common
2. Delete Card - By Card
OR
2. Delete Card - By ID number
OR
2. Delete User - By Card number Delete PIN User - Common
2. Delete PIN – by PIN
OR
2. Delete PIN – By ID number Delete Panic User
2. Delete Panic Card User
OR
2. Delete Panic PIN User Delete All Users Delete All User
3. Exit
(Master Code) #
2 (Read Card) #
The cards can be deleted continuously.
2 (User ID ) #
2 (Input 8/10 digits Card number) #
2 (Input PIN) #
2 (User ID ) #
2 (User ID ) #
2 (User ID ) #
2 (Master Code) #
Page 10
Set Relay Configuration
The relay configuration sets the behaviour of the output relay on activation.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Pulse Mode
OR
2. Toggle Mode
3. Exit *
* (Master Code) #
3 (1-99) # (factory default)
The relay time is 1-99 seconds. (1 is 50mS.)
(Default is 5 seconds)
3 0 #
Sets the relay to ON/OFF Toggle mode
Set Access Mode
For Multi cards/ PINs access mode, the interval time of reading cards/inputting PINs cannot exceed 5 seconds, or else, the XK Series device will exit to standby automatically.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Card access
OR
2. Card + PIN access
OR
2. Card or PIN access
OR
2. Multi cards /PINs access
3. Exit *
* (Master Code) #
4 0 #
4 1 #
4 2 #
4 3 (2~9) #
(Only after reading 2~9 cards or inputting 2~9 PINs, the door can be opened)
Set Strike-out Alarm
The strike-out alarm will engage after 10 failed card attempts (Factory is OFF). It can be set to deny access for 10 minutes after engaging or disengage only after entering a valid card/PIN or Master code.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Strike-Out OFF
OR
2. Strike-Out ON
OR
2. Strike-Out ON (Alarm)
Set alarm time
3. Exit *
* (Master Code) #
6 0 # (factory default)
6 1 # Access will be denied for 10 minutes
6 2 #
5 (0 ~ 3) # (factory default is 1 minute)
Enter Master code # or valid user card /PIN to silence
Page 11
Set Audible and Visual Response
Programming Step Keystroke Combination
1. Enter Program Mode
2. Control Sounds
OR
2. Control LED
OR
2. Control Keypad Backlit
3. Exit *
* (Master Code) # OFF = 7 0 #
OFF = 7 4 #
OFF = 7 6 #
Master Cards Usage
Using Master Cards to add and delete card users
ON = 7 1 #
ON = 7 5 #
ON = 7 7 #
(factory defaults are ON)
Add a User
Delete a User
1. (Read Master Add Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Add Card)
1. (Read Master Delete Card)
2. (Read User Card)
Repeat Step 2 for additional user cards
3. (Read Master Delete Card)
Users Operation & Reset to Factory Default
- Open the door: Read valid user card or inputting valid user PIN
- Remove Alarm: Read valid user card or inputting valid user PIN, or input Master Code #
- To reset to factory default & Add Master Cards: Power off, press the Exit Button, hold it and power on, there will be two beeps, and the LED light turns into yellow, release the exit button, then read any two 125KHz EM cards, the LED will turn into red, means reset to factory default successfully. Of the two cards reading, the 1
nd
Card, the 2
Remarks:
If no Master Cards added, must press the Exit Button for at least 10 seconds before release. Reset to factory default, the user’s information is still retained.
NOTE: (The Ness XK Units have some factory set adjustments after it has been ‘defaulted’. It is set in the factory as 26 Bit Wiegand and 10 Digit Virtual Number for when a PIN is entered. If a factory reset is performed onsite then these settings need to be manually reset back on again to have the units set as it was in the factory.)
one is the Master Delete Card.
st
one is Master Add
10
Page 12
CONTROLLER MODE
The XK Series device can work as Controller, connected with the external Wiegand re ader. (Factory default mode)---7 2 #
Connection Diagram
Attention: Install a 1N4004 or equivalent diode is needed when use a common power supply, or the reader might be
damaged. (1N4004 is included in the packing)
Set Wiegand Input Formats
Please set the Wiegand input formats according to the Wiegand output format of the external Reader.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Wiegand input bits
3. Exit *
* (Master Code) #
8 (26~37) # (factory default is 26bits)
Programming
- Basic Programming is the same as Standalone Mode
- There are some exceptions for your attention:
The XK Series device Connected with External Card Reader:
If EM card reader: users can be added/deleted on either the XK Series device or external reader. If Mifare reader: users can only be added/deleted on external reader.
11
Page 13
The XK Series device Connected with Keypad Reader:
The keypad reader can be 4 Bits, 8 Bits (ASCII), or 10 Bits output format. (when set to 10 Bits Output Format, when the PIN is entered the output from the keypad is as per a Wiegand Card No.
Choose the below operation according to the PIN output format of your reader.
Programming Step Keystroke Combination
1. Enter Program Mode
2. PIN input bits
* (Master Code) #
8 (4 or 8 or 10) # (factory default is 4bits) (Pre-Set in the factory after a ‘Factory default’ is 10 Bit Output format)
3. Exit * Remarks: 4 means 4 bits, 8 means 8 bits, 10 means 10 digits virtual number .
Add PIN Users:
To add PIN users, after enter into programming mode on the XK Series device, PIN(s) can be input/ added on either the XK Series device controller or the external Keypad Reader.
Delete PIN Users: the same way as add users.
12
Page 14
WIEGAND READER MODE
The XK Series device can work as Standard Wiegand Reader, connected to the third party Controller--- 7 3 #
To set as Wiegand Reader Mode, programming option 73# must be seleted.
Notes:
It will read EM format 125 Khz Cards.
Connection Diagram
Notes:
When set into Wiegand Reader mode, nearly all settings in Controller Model will become invalid. And Brown & Yellow wires will be redefined as below:
-Brown wire: Green LED light control
-Yellow wire: Buzeer control
If you need to connect Brown/Yellow wires: When the input voltage for LED is low, (i.e. Connected to 0V), the LED will turn to Green; and when the input voltage for Buzzer is low, (i.e. Connected to 0V), it will sound.
Set Wiegand Output Formats
Please set the Wiegand output formats of Reader according to the Wiegand intput formats of the Controller.
Programming Step Keystroke Combination
1. Enter Program Mode
2. Wiegand output bits PIN output bits
3. Exit *
* (Master Code) #
8 (26~37) # (factory default is 26bits) 8 (4 or 8 or 10) # (Factory default is 4bits)
(Pre-Set in the factory after a ‘Factory default’ is 10 Bit Output format)
13
Page 15
ADVANCED APPLICATION
User Information Transfer
The XK Series device supports the User Information Transfer function, and the enrolled user (cards, PINs) can be transferred from one (let’s name it ‘Master Unit’) to another (let’s name it ‘Accept Unit’).
Connection Diagram:
Remarks:
The ‘Master units’ and ‘Accept units’ must be XK Series or Sboard.
The Master Code of the ‘Master Unit’ and the ‘Accept Unit’ must be set to the same.
Program the transfer operation on ‘Master Unit’ only.
If the ‘Accept Unit’ is already with the users enrolled, it will be covered after transferring.
For full 1000 users enrolled, the transfer takes 3 minutes.
Set Transferring on ‘Master Unit’:
Programming Step Keystroke Combination
1. Enter the programming mode
2. Set transferring Within 3 minutes, Green LED shines, after one beep, the LED will turn into Red, which means the users’ information has been transferred successfully.
3. Exit
* (Master Code) #
9 6 #
*
14
Page 16
Interlock
The XK Series device supports the Interlock fu nci t o n. It is of tw o key pads for two doors, and mainly used for Control Rooms, banks, prisons, and other places where a higher level security is required.
Connection Diagram:
Remarks: The Door Contact mu st be installed and connected as the diagram.
Let’s name the two Keypads as “A “and “B” for two doors “1” and “2”
Step 1:
Enroll the users on Keypad A, then transfer the users’ information to Keypad B by ”User Information Transfer” funciton.
Step 2:
Set both of the two readers (A and B) to Interlock function
Programming Step Keystroke Combination
1. Enter Program Mode
2. Interlocked-OFF
OR
2. Interlocked-ON
3. Exit * The interlock operation is finished, When and only door 2 is closed, the user can read the valid card or input PIN on Reader A, door 1 will open; then when and only door 1 closed, read valid card or input PIN on Reader B, door 2 will open.
* (Master Code) #
9 0 # (factory default)
9 1 #
15
Page 17
Programming Summary
Function description Operation
Enter the programming mode
Change the master code
Add card user
Add PIN user
Delete user
Exit from the programming mode *
How to release the door
Card User Read card PIN User Input PIN #
*- 123456 - #
then you can do the programming (123456 is the factory default master code)
0 – new code - # - repeat the new code - #
(code: 6 digits)
1- Read Card - #
(can add Cards continuously)
1-
PIN - #
2 – Read Card -# for Card user 2 – PIN -# for PIN User
16
Page 18
Ness Ultraprox Bluetooth Keypad/Reader Installation & User Manual Rev 1.0
www.nesscorporation.com
National Customer Service Centre Ph: 1300 551 991 customerservice@ness.com.au
For the product: 101-091 / 101-091B Ultraprox Bluetooth keypad/ reader
Loading...