Neptune R450, R450 MIU User Manual

Page 1
ARB UTILITY MANAGEMENT SYSTEMS WATER
|
ELECTRIC |GAS
E-Cod
R450 Wall and Pit User's Manual
R450 WALL AND PIT USER'S MANUAL
Page 2
Page 3
ARB UTILITY MANAGEMENT SYSTEMS WATER | ELECTRIC | GAS
R450 Wall and Pit User’s Manual
Page 4
This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical for any purpose, without the express written permission of Nep tune Technology Group Inc. All rights to designs or inventions disclosed herein, including the right to manufacture, are reserved to Neptune Technology Group Inc.
The information contained in this document is subject to change without notice. Neptune reserves the right to change the product specifications at any time without incurring any obligations.
-
Trademarks used in this manual
R450 is a trademark of Neptune Technology Group Inc. Other brands or product names are the trademarks or registered trademarks of their respective holders.
FCC Notice
This device complies with part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful inter ference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
-
RF Exposure Information
This equipment complies with the FCC RF radiation requirements for uncontrolled environments. To maintain compli­ance with these requirements, the antenna and any radiating elements should be installed to ensure that a minimum separation distance of 20cm is maintained from the general population.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
Professional Installation
In accordance with section 15.203 of the FCC rules and regulations, the MIU must be professionally installed by trained utility meter installers.
Page 5
Industry Canada
This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Cet appareillage numérique de la classe B répond à toutes les exigences de l'interférence canadienne causant des règlements d'équipement. L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée.
R450 Wall and Pit MIU User’s Manual
Literature No. UM R450 09.06
Part No. XXXXX-XXX
Copyright © 2006
Neptune Technology Group Inc.
All Rights Reserved.
Neptune Technology Group Inc.
1600 Alabama Highway 229
Tallassee, AL 36078
Tel: (334) 283-6555
Fax: (334) 263-7299
Page 6
Page 7
1 Product Description
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
R450 MIU Programming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
RF Protocol Error Detection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Low Battery RF Emissions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2 Specifications
Electrical Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Encoder Register Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Specifications - R450 Pit MIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Contents
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Specifications - R450 Wall MIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Environmental Conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Functional Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Dimensions and Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3 General Installation Guidelines
Tools and Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Safety and Preliminary Checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Verifying/Preparing the Encoder Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Installation of at Register (Non Pre-Wired or Potted Only ) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Replacing the MIU Battery (Wall and Pit)
Removing the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Cutting and Splicing the Battery Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Replacing the Transmitter Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
R450 Wall and Pit User’s Manual v
Page 8
Contents
Glossary
Index
vi R450 Wall and Pit User’s Manual
Page 9
Figures
Figure Title Page
1Wall MIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2Pit MIU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3 Pit MIU Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
4 Wall MIU Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
5 Wiring a Neptune Encoder Register . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
6 Cable Threaded Around Strain Relief Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
7 Application of the Sealant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
8 Covering the Terminal Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
9 Removing the MIU Transmitter Cover. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
10 The Battery Compartment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
11 Cutting the Battery Connection. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
12 Splicing the New Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
13 Location of Toroid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
14 Returning Spliced Battery to Main Housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
R450 Wall and Pit User’s Manual v
Page 10
Figures
Notes:
vi R450 Wall and Pit User’s ManualN
Page 11
Tables
Table Title Page
1 Recommended Tools . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2 Recommended Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
3 MIU Color Code for Wires . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
4 Available Replacement Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
R450 Wall and Pit IUser’s Manual vii
Page 12
Tables
Notes:
viii R450 Wall and Pit IUser’s Manual
Page 13
1 Product Description
This section provides a general description of the R450 Meter Interface Unit (sub­sequently referred to as R450 MIU or MIU).
The R450 MIU by Neptune is a compact electronic device that collects meter read­ing data from an encoder register. It then transmits the data for collection.
The R450 MIU is easily installed and requires an Federal Communications Commission (FCC) license to operate.
Figure 1 Wall MIU Figure 2 Pit MIU
Product Description
R450 MIU Programming
The MIU is NOT field programmable. At the factory, each of the following items are programmed into the MIU:
Serial numbers – Each MIU is given two unique serial numbers/identification num­bers (two IDs for compound units). Even numbers are given to the single registers and odd numbers are given to a two-networked registers unit. Custom serial num bers are not available.
RF Protocol Error Detection
The RF protocol is comprised of a header, data packet, and an error detection
mechanism that reduces the erroneous data.
Low Battery RF Emissions
The MIU stops RF transmissions when the battery discharges below the normal operating voltage.
-
R450 Wall and Pit MIU User’s Manual 1
Page 14
2 Specifications
This section provides you with the specifications for the R450 MIU.
Electrical Specifications
Encoder Register Interface
Supported Encoder Maximum Cable Length
Neptune ARB® V
2
300 feet (91 meters)
Neptune ProRead (ARB® VI)
500 feet (152 meters)
and E-Coder (ARB® VII)
Invensys ECR II®and ECR III
®3
Networked Neptune ProRead (ARB VI) /
200 feet (61 meters)
250 feet (76 meters)
E-Coder (ARB VII)
2
The length, which meets manufacturers’ published specification for wire length between encoder and remote receptacle,
is based on solid 3 conductor wire, 22 AWG.
3
Only specific formats of ECRIII programming are compatible. Contact Neptune for details.
R450 Wall and Pit MIU User’s Manual 2
Page 15
Specifications - R450 Pit MIU
Environmental Conditions
Operating Temperature -22° to 149°F (-30° to 65°C)
Storage Temperature -40° to 158°F (-40° to 70°C)
Operating Humidity 0 to 95% Condensing
Functional Specifications
Register Reading 8 digits
MIU ID 9 digits
Dimensions and Weight
Dimensions Refer to Figure 3
Weight 1.0 lbs. (454 grams)
Specifications
R450 Wall and Pit MIU User’s Manual 3
Figure 3 Pit MIU Dimensions
Page 16
Specifications
Specifications - R450 Wall MIU
Environmental Conditions
Operating Temperature -22° to 149°F (-30° to 65°C)
Storage Temperature -40° to 158°F (-40° to 70°C)
Operating Humidity 0 to 95% Condensing
Functional Specifications
Register Reading 8 digits
MIU ID 9 digits
Dimensions and Weight
Dimensions Refer to Figure 4
Weight 1.0 lbs. (454 grams)
4 R450 Wall and Pit MIU User’s Manual
Figure 4 Wall MIU Dimensions
Page 17
3 General Installation Guidelines
This section describes tools, materials, and general installation information for the R450 MIU.
Tools and Materials
Tables 1 and 2 show the recommended tools and materials you may need to suc­cessfully install the R450 MIU or to replace the MIU’s internal battery.
Some items may not apply to your specific installation or the list may not contain all required tools or materials.
Item Description/ Recommendation Use
Table 1 Recommended Tools
Tool Kit Contains standard tools including:
Assorted screwdrivers
Needle-nose pliers
Wire stripper
Diagonal cutters
Electrician’s knife
•Hammer
Crimping Tool Part #: 5500-158
Magnet 6 lb. force
Part #: 12287-001
Table 2 Recommended Materials
Item Description/Recommendation Use
Cable Solid 3 conductor,
#22 AWG (black/green/red) Part#: 6431-352
Moisture protection compound
Novaguard sealant Part #: 96018-072
Various installation procedures performed by the utility
Activating the MIU
Connecting MIU to encoder register
Covering exposed wires and termi­nal screws on register and MIU
R450 Wall and Pit MIU User’s Manual 5
Page 18
General Installation Guidelines
Table 2 Recommended Materials
Item Description/Recommendation Use
Scotchloks Part #: 8138-125 Splicing replacement battery wire
and connecting Wall MIU or replacement Pit MIU to encoder register
Site Work Order Documentation provided by your
Safety and Preliminary Checks
Observe the following safety and preliminary checks before and during each instal­lation:
• Verify that you are at the location specified on the Site Work Order.
• Verify that the site is safe for you and your equipment.
• Notify the customer of your presence and tell the customer that you will need access to the water meter.
• If the Site Work Order does not have an MIU ID number on it, write in the ID number(s) of the MIU you are about to install. If the Site Work Order already has an MIU ID number on it, verify that it matches the ID numbers on the MIU you are about to install.
Verifying/Preparing the Encoder Register
This R450 MIU is designed for use with the following encoder registers:
utility
ARB III, IV, and V
Receiving and recording informa­tion about the work site
Before installing an MIU, the encoder register must be correctly wired and/or pro­grammed to work with the MIU. ProRead (ARB VI) encoder registers do not require programming.
When a ProRead (ARB VI) encoder register is used, the non-AutoDetect ProRead (ARB VI) register must be programmed for three-wire mode.
6 R450 Wall and Pit MIU User’s Manual
ProRead (ARB VI)
ProRead AutoDetect
E-Coder (ARB VII)
Invensys ECRII, ECR III *
*when programmed in ECR II 6-wheel format
Page 19
If connecting the MIU to a new ProRead (ARB VI) encoder register, or if a three­conductor cable is already connected to a ProRead (ARB VI) encoder register, ensure that the ProRead (ARB VI) register is programed for three-wire mode using the ProRead (ARB VI) programmer and its RF/MIU 6, 8, or 10ID TDI format. This can be accomplished through the ProRead (ARB VI) receptacle before removing the receptacle.
Installation of at Register (Non Pre-Wired or Potted Only )
1 Before wiring the pit encoder register, make sure the cable is long enough.
Then, when the installation is complete, the pit lid can be removed easily with out straining the cable.
2 Use only 22 AWG cable to make the connection from the encoder register to
the MIU.
3 Remove the terminal screw cover from the encoder register.
4 Strip off 3/4” of jacket from the cable, leaving only the three insulated wires.
General Installation Guidelines
-
5 Taking precautions not to nick or cut the insulation on the three wires, strip off
1/2” of insulation from each of the three wires.
Figure 5 Wiring a Neptune Encoder Register
Encoder Register MIU Wire Color/ Encoder Terminal Marking
Neptune ARB® III, IV, and V
Neptune ProRead (ARB VI) E-Coder (ARB VII)
Table 3 MIU Color Code for Wires
Black / B Green / G Red / R
Black / B Green / G Red / R
ECRII® and ECRIII
®
6 If required, connect the 3 conductor wire to the encoder register’s terminals
R450 Wall and Pit MIU User’s Manual 7
Black / R Green / B Red / G
per the manufacturer’s instructions. See
Figure 5 and Table 3.
Page 20
General Installation Guidelines
7 Thread the cable around the strain relief posts of the encoder (Figure 6).
Figure 6 Cable Threaded Around Strain Relief Posts
8 Apply sealant liberally and ensure that it encapsulates the terminal screws and
exposed wires. (See
Figure 7).
Neptune requires Novaguard G661 sealant or Dow Corning compound 4.
8 R450 Wall and Pit MIU User’s Manual
Figure 7 Application of the Sealant
Any leak point can cause a reading failure in a submerged meter setting.
Page 21
General Installation Guidelines
9 Snap the cover onto the encoder register (Figure 8).
Figure 8 Covering the Terminal Screws
10 Run the cable to the MIU, fastening it securely as necessary.
Do not exceed maximum cable lengths as defined in Table 4.
11 If encoder register is pre-wired and potted, use Scotchloks for connecting
register to MIU.
12 Proceed to the section specified for either Pit or Wall installation.
R450 Wall and Pit MIU User’s Manual 9
Page 22
4 Replacing the MIU Battery (Wall and Pit)
Follow these steps to change-out the pit R450 MIU’s internal battery:
Removing the Battery
1 Slowly remove the pit lid.
Because the MIU is connected to both the antenna in the pit lid and the meter in the pit base, take care not to strain the cable when removing the lid.
2 Remove the transmitter cover by removing the two Phillips head
crews located inside the back cavity of the main housing. (See Figure 9.)
3 Lift the transmitter cover from the MIU.
screw
transmitter cover
Figure 9 Removing the MIU Transmitter Cover
Figure 10 The Battery Compartment
antenna
4 Remove the battery casing from the main housing by inserting a flat-
head screwdriver and dislodging the battery from the battery com partment. (See Figure 10.)
When removing the battery, it may be helpful to press on the connected end while prying the other end.
nut
antenna cable
waterproof connector
-
R450 Wall and Pit MIU User’s Manual 10
Page 23
Figure 11 Cutting the Battery Connection
Replacing the MIU Battery (Wall and Pit)
Cutting and Splicing the Battery Wires
1 As close to the battery casing as possible, cut the battery
connection wires one at a time. See
2 Insert battery wire left in MIU ensuring insulation has not
been compromised.
Cutting the battery connection wires one at a time prevents shorting. Ensure the R450 MIU’s black wire is connected to the black wire on the new battery (-) and the red wire is connected to the red wire on the new battery (+).
Figure 11.
Figure 12 Splicing the New Battery
Figure 13 Location of Toroid
3 Use Scotchlok to splice the wires from the new battery
casing to the wires that were connected to the old battery casing. See
4 Be sure to carefully position wires and Scotchloks into
compartment in space available next to battery as shown
Figure 13, making sure the wires are not pinched when
in the battery is snapped into the MIU housing.
Figure 12.
R450 Wall and Pit MIU User’s Manual 11
Page 24
Replacing the MIU Battery (Wall and Pit)
Figure 14 Returning Spliced Battery to Main Housing
5 Snap the battery casing into the receiving clips on the main
housing. See
6 Reactivate the MIU as shown.
Figure 14.
Replacing the Transmitter Cover
1 Secure the transmitter cover using the two Phillips head
screws, until the cover is snug and fully seated.
Be careful not to pinch the battery wires between the cover and the housing.
2 Replace the pit lid.
12 R450 Wall and Pit MIU User’s Manual
Page 25
Replacement Parts
Replacing the MIU Battery (Wall and Pit)
Table 4 lists the available replacement parts for the R450 MIU.
Table 4 Available Replacement Parts
Part Name Part Number
Solid 3 conductor wire, 22 awg (1000 ft.) 6431-352
Dow Corning #4 compound (5.3oz tube) 96018-064
GE Novaguard (4cc Packet) 96018-072
Scotchloks (UG) 8138-125
Battery Assembly 12213-100
Mounting Adapter 12539-001
Fastener Screw 8328-302
Magnet 12287-001
Antenna 12527-000
Flat Washer 8340-054
R450 Wall and Pit MIU User’s Manual 13
Page 26
Replacing the MIU Battery (Wall and Pit)
Notes:
14 R450 Wall and Pit MIU User’s Manual
Page 27
Glossary
antenna (pit) The MIU antenna used for pit installations.
conical-shaped gasket The cone-shaped rubber gasket on antenna cable used to seal cable
at top of connector housing.
connector housing The black plastic 1/4-turn connector used to waterproof antenna
cable connection to pit MIU.
connector nut The black plastic nut used to depress conical-shaped gasket and seal
antenna cable at the top of connector housing.
flat washer The washer used to seal cable connector housing to pit MIU.
main housing The main body of the MIU that attaches to the mounting adapter.
main housing fastener screw The set screw (Hi-Lo fastener) that holds the main housing to the
mounting adapter.
maximum cable length The length set by the manufacturer for the wire between the encoder
and the remote receptacle. The specifications for this length are based on a solid 3 conductor wire.
MIU Meter Interface Unit.
mounting adapter The back plate of the MIU that is attached to the wall.
register read time The default time is once an hour for ProRead and 15 minute interval
for E-Coder (ARB VII). Custom time is not available.
seal wire Wire inserted into the seal holes, adjacent to the main housing fas-
tener screw. This seal must be broken to remove the main housing from the mounting adapter.
serial number A unique identification number given to each MIU at the factory. The
default value is the last programmed plus one. Custom serial numbers are not available.
strain relief posts Posts located on the encoder register and the back of the main MIU
housing.
R450 Wall and Pit User’s Manual G-1
Page 28
Glossary
terminal screw cover The plastic cover on the encoder register that protects the terminal
screws and exposed wires.
terminal screws The screws on the encoder register face that are used to connect and
anchor the three (3) conductor wire to the register.
transmission time The time between MIU transmissions. The default is approximately
fourteen (14) seconds. Custom time is not available.
G-2 R450 Wall and Pit User’s Manual
Page 29
Index
Numerics
3-conductor 13 3-conductor wire 7 3-wire mode 6, 7
A
antenna
10
care
part # 13
B
Battery
10
replace
battery
assembly
casing 11, 12 compartment 10 connection 11 internal 5, 10 low, RF emission 1 main housing 12 new 11 remove 10 remove casing 10 replacing 10 wires 11
13
C
cable 5
3-conductor 7 lengths 2, 9 strain relief posts 8 threaded 8
compound units 1
connect
3-conductor cable
3-conductor wire 7 cable 7 encoder register 7 MIU 5, 7
7
interface 2 maximum cable length 2
Environmental conditions 3, 4
F
Functional specifications 3, 4
G
gel caps 11
I
Installation
preliminary checks
safety 6
Installing
encoder register
preparing for 6
insulation
7
wires
6
7
L
low battery emissions 1
M
meters
multiple units
multiple units 1
1
O
operating humidity 3, 4 operating temperature 3, 4
P
part numbers 13 product description 1
programmable
non-field programmable
1
D
description, R450 1 dimensions 3, 4
E
electrical specifications 2
Encoder register
illustrated
R450 Wall and Pit User’s Manual I-1
7
R
R450 MIU
description
dimensions 3, 4 low battery emissions 1 programming 1 replacement parts 13 tools and materials 5 weight 3, 4
1
Page 30
Index
Replacement parts 13
part numbers 13 Replacing 10 replacing the battery 10
RF
frequency control
low battery emissions 1
protocol 1
1
S
ScotchLox 11 serial numbers 1
Specifications
dimensions
electrical 2
encoder register interface 2
environmental conditions 3, 4
functional 3, 4
weight 3, 4
splice
wires
storage temperature 3, 4
strain relief
posts
stripper, wire 5
3, 4
11
8
T
Transmitter specifications 2
U
units
multiple IDs
1
W
weight 3, 4
wire
5
stripper
wires
3 conductor
3-conductor 2, 7 3-wire mode 6, 7 battery connection 11 black toroid 11 connected to old battery 11 exposed 5, 8 length 2 MIU color code 7 splicing 11
wires, from battery 11
wiring
correct
Neptune encoder register 7 register 7
13
6
temperature, storage 3, 4
I-2 R450 Wall and Pit User’s Manual
Page 31
Page 32
Neptune Technology Group Inc.
1600 Alabama Highway 229 Tallassee, AL 36078 USA Tel: (800) 645-1892 Fax: (334) 283-7299
UM R450 09.06 Part No. XXXXX-XXX
Neptune Technology Group (Canada) Ltd.
7275 West Credit Avenue Mississauga, Ontario L5N 5M9 Canada Tel: (905) 858-4211 Fax: (905) 858-0428
© Copyright 2006, Neptune Technology Group Inc. Neptune is a registered trademark of Neptune Technology Group Inc.
Neptune Technology Group Inc.
Ejército Nacional No. 418 Piso 12, Desp. 1201-1202 Col. Chapultepec Morales Delegación Miguel Hidalgo 11570 México, Distrito Federal Tel: (525) 55203 5294 / (525) 55203 5708 Fax: (525) 55203 6503
neptunetg.com
Loading...