Neotech Communications FEC-11CV User Manual

Page 1
FEC-11CV Series
Industrial 10/100Base-TX Ethernet plus CVBS Over Coaxial Converter
This quick start guide describes how to in stall and u se the Industrial Coaxial Converte r . This is the Coaxial Converte r of choice for harsh environments constrained by space.
Overview
General
To ensure trouble free transpor tation and storage, all Neotech prod ucts must be thoroughly inspected , tested and properly packed before delivery. Check the product upon receipt for any visible damage which may have been caused during shipment.
Package Content
Transmitter (FEC-11CV - T) or Receiver (FEC-11CV-R) of Ethernet Extender over Coaxial Converter x1  Power Adapt er x 1
Quick Start Guide x 1
Physical Description
Front/Rear Panel
Power Input
SPD PWR
Link/ACT ACT
CVBS Input / Output
CVBS In/Out
LINK
Coax Data
1 V1.0
Page 2
FEC-11CV Series
Industrial 10/100Base-TX Ethernet plus CVBS Over Coaxial Converter
Installation
a) The product has two mounting holes. See Figure 1 for its structure. Mount the product on wall or a flat surface.
Mounting holes
Figure 1. Case dimensions
b) Typical cable connection diagram:
Installation Steps a) Connect the COAX DATA connector of the transmitter (TX) and receiver (RX) with coaxial cable. b) At TX side, connect the analogue camera video signal to the CVBS INPUT connector with coaxial cable, the IP
camera signal to the Ethernet port (10/100) with network cable.
c) At RX side, connect the monitor to the CVBS OUTPUT with the coaxial cable, the NVR/switch to the Ethernet
port (10/100) with network cables to the switch or PC. d) The PWR light is on when the product is powered on. Check if the power cable is working properly. e) After all cables are correctly connected, the indicators will be lit as per port status LEDs (page 3).
2 V1.0
Page 3
FEC-11CV Series
Industrial 10/100Base-TX Ethernet plus CVBS Over Coaxial Converter
Interface Ethernet Port:
a) Ethernet port RJ45:
10/100M Ethernet port pin sequence diagram:
Power Connection
GND
12VDC
-
12V
+
- +
Pin MDI Signal Definition
1
TD+ RD +
2
TD- RD-
3
RD + TD+ 4 NC 5 NC NC 6
RD- TD- 7 NC 8 NC NC
Terminal Block
MDIX Signal
Definition
NC
NC
3 V1.0
Page 4
FEC-11CV Series
Industrial 10/100Base-TX Ethernet plus CVBS Over Coaxial Converter
The Port Status LEDs, dimension drawing of the Micro unit
Indicator Color Description
PWR
LINK
COAX
DATA
ACT
CVBS IN (TX only)
CVBS OUT (RX only)
SPD
10/100
(Ethernet)
LINK/ACT
Green Power on.
Off Power off.
Green The COAX DATA link
(between TX & RX) is established.
Flashing Data is being
transmitted or received. ACT Stands for Activity.
Green Video input Green Video output
Orange 100Base-TX
Off 10Base-TX
Steady A valid network
connection is established
Flashing Data is being
transmitted or received. ACT Stands for Activity.
Functional Description
Ethernet Extension : Security Link over Coax Simultaneous transmission of IP and CVBS over single coaxial cable Constant Data Rate : 36Mbps(Downlink)/11Mbps(Uplink) Maximum distance : 300m over Coax(RG-59/U) Support Auto MDI/MDI-X -10Ԩ to 60Ԩ operating temperature.
Assembly, Startup, and Dismantling
Installation
Installation: Mount the Micro type unit onto a fixture, or camera housings, e.g. a plank, (either on the wall or on
a flat surface) with at least 2 screws piercing through the holes on the mounting frame to secure it in position.
Startup: Connect the supply voltage to start up the Media Converter via the terminal block. Dismantling: Locate and remove the securing screws. Usually, but not limited to, at least 2 screws.
Manual Earth Green manual is available on our website www.neotechcomm.com.tw
4 V1.0