Neomedic P1000 User Manual

POWERPRESS UNIT
User Manual
Pneumatic Sequential Compressor
Neomedic
9601 Owens mouth Ave. #8 Chatsworth, CA 91311
Toll Free: 866-990-1168 Tel: 818-998-1023 Fax: 818-998-0277
www.air1000.com info@air1000.com
Contents
1. Introduction ---------------------------------------------------------------------- 4
2. Clinical Application-------------------------------------------------------------- 5
3. Clinical Treatment Guide ------------------------------------------------------ 6
4. Garment type & Size------------------------------------------------------------ 7
5. Pump Description --------------------------------------------------------------- 8
6. Warranty ------------------------------------------------------------------------- 10
7. General Safety-------------------------------------------------------------------- 10
8. Caution---------------------------------------------------------------------------- 10
9. Trouble Shooting----------------------------------------------------------------- 11
10. Technical Description----------------------------------------------------------- 11
3
2. Clinical Application
Intermittent Compression Therapy
A thorough assessment of the patient should be made considering
the general state of the patient and the specic characteristics of their
presenting condition. The choice of system, i.e. garment and treatment regime, is to be recommended by the medical practitioner for the patient.
Training and education of the patient in the use and understanding of the system will help to ensure compliance.
Indications • Lymphedema - primary
- secondary;
• Oedema - dependent
- traumatic
- secondary to stroke;
• Chronic Venous Insufciency
Cautions 1. Proper application and connection to the pump is essential.
2. Garments should be removed if the patient experiences tingling, numbness or pain.
Contraindications
POWERPRESS unit should NOT be used in the following conditions:
1. Severe arteriosclerosis or other ischemic vasular diseases.
2. Known or suspected acute deep vein thrombosis.
3. Severe congestive cardiac failure.
4. Any local condition in which garments would interfere, for example:
• Gangrene • Dermatitis
• Untreated, infected leg wounds
• Recent skin graft
5
1. Introduction
The Powerpress Unit system consists of a pneumatic pump which is light and simple to use and a 4 chamber garment. It is suitable for home use.
The pump supplies air via connecting tubes to an inatable garment
allowing the application of controlled pressure to gently compress the limb.
This action assists in increasing the return of blood, excess uids, improves
venous stasis and encourages the reabsorption of waste products.
Compression Cycle:
36sec ination (9sec each chamber) / 24 sec deation Chamber 1 (Foot) = 36sec Chamber 2 (Ankle) = 27sec Chamber 3 (Calf) = 18sec Chamber 4 (Thigh) = 9sce
Variable pressure output ranges from 30-160 mmHg. The segments within the garments are designed to prevent ridging and ensure high patient comfort and compliance.
** We would recommend that this manual is read throughly before proceeding with treatment. Please also refer to clinical guidelines and contraindications.
4
3. Clinical Treatment Guide
An initial pressure of 40 mmHg (30 mmHg for management of lymphedema)
is suggested at the commencement of treatment. It may be necessary to start at a lower level of pressure, dependent on the patient’s tolerance.
The pressure can be gradually increased over time, until the required pressure is reached. The upper treatment pressure range is generally
60-70 mmHg.
A single treatment session is usually 20-60 minutes. The above settings and timings are guidelines, and should not be used as a substitute for clinical judgement and experience.
6
zip
Full Leg Sleeve
Open
Arm Sleeve
Open
zip
zip
X Large Full Leg Sleeve
Open
Circumference
Open
zip
Half Leg Sleeve
Open
zip
X Large Half Leg Sleeve
Circumference
Available Extenders size
Half Leg Sleeve: 4”, 6” Arm Sleeve: 4”, 6” Full Leg Sleeve: 4”, 6”
4. Garments type & size
18”(L)
22”
19.5”(L)
18”
9”
20”
28.5”(L)
13”
26”
28”(L)
30”(L)
16”
12”
25”
18”(L)
19.5”(L)
9”
14”
28”(L)
30”(L)
22”
14”
30”
7
5. Pump Description
30
40
50
60
70
80
90
100
110
120
130 140
mmHg
PRESSURE
150
MIN
MAX
20
PRESSURE
1
2
3
4
CHAMBER
1 2 3 4
side view
1 Main Pressure Controller Knob (Push to Lock, Pull to release)
2 Pressure Gauge (0 ~ 160mmHg)
3 Air Tubing Hose Connector
4 Power Switch
Operation: The pump should be placed securely on a at surface.
Before starting the pump ensure that the garments are properly applied,
the zippers are secured and the garment connecting tubes are attached
to the pump outlet ports.
8 9
How to SET UP Pressure?
Model# P1000
1. Turn on Power Switch
2. Wait until deation time
During Deation Time; Pressure Gauge does not move Air does not inate sleeves
Air in the sleeves comes out Air does not come out from connection port
3. Turn Pressure Knob quickly and set to desired pressure
4. Connect Tubing Hose and wear sleeves.
During usage of Pump : Wait until deation time to set desired pressure
To Remove the Garment: Switch off the pump, disconnect the tubing from the pump by removing the tube connectors.
6. Warranty
All Powerpress Unit shall conform to applicable specications in effect
from the invoice date to the end of the Warranty Period, and Power-
press Unit reserves the right to change such specications at any time
with or withour notice. The Warranty Period for Powerpress Unit prod­ucts shall be as follows, calcuated from the date of invoice:
• The Powerpress Unit pump is guaranteed for 12 months
• The powerpress Unit garments are guaranteed for 6 months
7. Safety Warnings
• Electrical equipment may be hazardous if misused. The pump’s rear case should only be removed by authorized technical personnel.
• Do not use the pump in the presence of ammable gases such as
anesthetic agents.
• Make sure that the main power cable is positioned to avoid causing a trip or other hazard, and is clear of moving bed mechanisms or other possible entrapment areas.
8. Caution
Electromagnetic compatibility (EMC). This product complies with the
requirements of applicable EMC Standards. The use of accessories not
specied by the manufacturer may result in increased emissions by, or
decreased immunity of, the equipment, affecting its performance.
10
9. Troubleshooting
If you should encounter a problem, please follow the fault nding guide below, if the fault cannot be rectied, please refer to Service.
10. Technical Description
Model No: P1000
Supply Voltage: 120 V
Supply Frequency: 60 Hz
Electrical Rating: 14VA
Fuse Rating: F500mAH250V
Size: Length: 11.8” (300mm)
Width: 8.3” (210mm)
Height: 5.1” (130mm)
Weight: 4.5lbs (2kg)
Case Material: ABS Plastic
Mode of Operation: Continuous
11
Fault
Pump does not operate.
Pump operates but garments will not
inate.
None of the above.
Check
Is power switch on? Is power cord plugged in correctly?
Blockage in garment supply tube.
Garment not correctly
tted to pump.
Pressure control set too low.
Air leak in garment.
Remedy
Check switch. Check connections.
Ensure that the tube airway is clear.
Check connections.
Increase pressure control.
Check garemt. Replace if defective.
Hint - Reduced pressure level indicates garment or connector leak
None of the above. Call Service