Nelson GA-1343, LT-SE End Seal Kit Instruction Sheet

Page 1
NELSON™ HEAT TRACING SYSTEMS
INSTALLATION
LT-SE END SEAL KIT
DESCRIPTION
The LT-SE End Seal Kit is for use with all versions of Nelson Heat Tracing Systems’ LT & CLT heater cables except for J option. Minimum installation temperature –30°C (-22°F).
25mm (1")
102mm (4")
Cut heater cable off at required length. Strip
overjacket back 102mm (4”) from the end of heater cable. Slide braid back over the overjacket portion of the heater cable.
Cut off excess heater cable leaving 25mm (1”).
INSTRUCTIONS
KIT CONTENTS
5 Shrink Tubes, 13mm (0.5”) dia., 51mm (2”) length 5 Shrink Tubes, 16mm (0.63”) dia., 76mm (3”) length
excess shrink tube
While still warm, squeeze the entire width of shrink
tube closed. Cut off excess shrink tube.
Pull braid over the squeezed shrink tube, covering
the entire end seal and twist closed.
For Overjacket Products only:
At the end of the heater cable, snip a 10mm (0.4”)
slit between the bus wires. Slightly spread wires apart.
!
Do not overlap braid with shrink tube.
Slide a 16mm (0.63”) diameter, 76mm (3”) length
shrink tube over the braid leaving approximately 13mm (0.5”) of shrink tube past the braid. Shrink with heat gun until completely shrunk.
While still warm, squeeze the entire width of shrink
tube closed.
Slide a 13mm (0.5”) diameter, 51mm (2”) length
shrink tube over the heater cable leaving approximately 25mm (1”) of shrink tube past the heater cable. Shrink with heat gun until completely shrunk.
P.O. BOX 726 TULSA, OK 74101 TEL 918-627-5530 FAX 918-641-7336 www.nelsonheaters.com
Nelson Heat Tracing Systems products are supplied with a limited warranty. Complete Terms and Conditions may be found on Nelson's website at www.nelsonheaters.com
Sheet 1 of 1