NEFF D99W59N0/01 Installation Instruction [de]

de
Montageanleitung Wandesse
en
Installation instructions Wall-mounted chimney extractor
fr
nl
Montagevoorschrift Wandafvoer
it
Istruzioni per il montaggio Camino a muro
es
Instrucciones de montaje Campana extractora para fijar a la pared
el
Οδηγίες τοποθέτησης Απορροφητήρας κουζίνας τύπου τζακιού, για στερέωση στον τοίχο
de
en
fr
nl
it
es
el
2
de Seite 03–07
en page 08–12
fr page 13 – 17
nl pagina 18 – 22
it pagina 23 – 27
es página 28 – 32
el Σελίδα 33 – 37
3
Wichtige Hinweise
Zusätzliche Hinweise bei Gas-Koch­geräten:
Bei der Montage von Gaskochstellen
sind die national einschlägigen gesetzlichen Bestimmungen (z. B. in Deutschland: Technische Regeln Gasinstallation TRGI) zu beachten.
Es müssen die jeweils gültigen Einbau-
vorschriften und die Einbauhinweise der Gas-Gerätehersteller beachtet werden.
Die Dunstabzugshaube darf nur an
einer Seite neben einem Hochschrank oder einer hohen Wand eingebaut werden. Abstand mind. 50 mm.
Mindestabstand bei Gas-Kochstellen
zwischen Oberkante Topfträger und Unterkante der Dunstabzugs­haube: 650 mm, Abb. 1.
Altgeräte sind kein wertloser Abfall.
Durch umweltgerechte Entsorgung können wertvolle Rohstoffe wiedergewonnen werden. Bevor Sie das Altgerät entsorgen, machen Sie es unbrauchbar.
Ihr neues Gerät wurde auf dem Weg zu
Ihnen durch die Verpackung geschützt. Alle eingesetzten Materialien sind umweltver­träglich und wieder verwertbar. Bitte helfen Sie mit und entsorgen Sie die Verpackung umweltgerecht.
Über aktuelle Entsorgungswege informieren Sie sich bitte bei Ihrem Fachhändler oder bei Ihrer Gemeindeverwaltung.
Die Dunstabzugshaube ist für Abluft-
und Umluftbetrieb verwendbar.
Die Dunstabzugshaube immer über der
Mitte der Kochstellen anbringen.
Mindestabstand zwischen Elektro-
kochstellen und Unterkante der Dunstab­zugshaube: 550 mm, Abb. 1.
Über einer Feuerstätte für feste
Brennstoffe, von der eine Brandgefahr (z. B. Funkenflug) ausgehen kann, ist die Montage der Dunstabzugshaube nur dann zulässig, wenn die Feuerstätte eine
geschlossene nicht abnehmbare Abdeckung hat und die länderspezifischen
Vorschriften eingehalten werden. Diese Einschränkung gilt nicht für Gas­Herde und Gas-Mulden.
Je kleiner der Abstand zwischen
Dunstabzugshaube und Kochstellen desto größer ist die Möglichkeit, dass sich durch aufsteigenden Wasserdampf unten an der Dunstabzugshaube Tropfen bilden können.
Vor dem Lesen bitte die letzten Seiten mit den Abbildungen ausklappen.
Dieses Gerät ist ent-
sprechend der europäischen Richtlinie 2002/96/EG über Elektro­und Elektronik-Altgeräte (waste electrical and electronic equipment – WEEE) gekennzeichnet. Die Richtlinie gibt den Rahmen für eine EU-weit gültige Rücknahme und Verwertung der Altgeräte vor.
4
Vor der Montage
Abluftbetrieb Abb. 2
Die Abluft wird über einen Lüftungsschacht nach oben, oder direkt durch die Außen­wand ins Freie geleitet.
D
Die Abluft darf weder in einen in Betrieb befindlichen Rauch- oder Abgaskamin noch in einen Schacht, welcher der Ent­lüftung von Aufstellungsräumen von Feuer­stätten dient, abgegeben werden.
Bei der Ableitung von Abluft sind die behördlichen und gesetzlichen Vor­schriften (z. B. Landesbauordnungen) zu beachten.
Bei Abführung der Luft in nicht in Betrieb befindliche Rauch- oder Abgaskamine ist die Zustimmung des zuständigen Schorn­steinfegermeisters einzuholen.
D
Bei Abluftbetrieb der Dunstabzugs­haube und gleichzeitigem Betrieb schornsteinabhängiger Feuerungen (wie
z. B. Gas-, Öl- oder Kohleheizgeräte, Durchlauferhitzer, Warmwasserbereiter)
muss für ausreichend Zuluft gesorgt werden, die von der Feuerstätte zur Ver-
brennung benötigt wird. Ein gefahrloser Betrieb ist möglich, wenn
der Unterdruck im Aufstellraum der Feuerstätte von 4 Pa (0,04 mbar) nicht überschritten wird.
Abluftbetrieb Abb. 2
Dies kann erreicht werden, wenn durch nicht verschließbare Öffnungen, z.B. in Türen, Fenstern und in Verbindung mit Zuluft-/Abluftmauerkasten oder durch andere techn. Maßnahmen, wie gegenseitige Verriegelung o.ä., die Verbrennungsluft nachströmen kann.
Bei nicht ausreichender Zuluft besteht Vergiftungsgefahr durch zurückgesaugte Verbrennungsgase.
Ein Zuluft-/Abluftmauerkasten allein stellt die Einhaltung des Grenzwertes nicht sicher.
Anmerkung: Bei der Beurteilung muss immer der gesamte Lüftungsverbund der Wohnung beachtet werden. Bei Betrieb von Kochgeräten, z. B. Kochmulde und Gasherd wird diese Regel nicht angewendet.
Wenn die Dunstabzugshaube im Umluftbe­trieb – mit Aktivkohlefilter – verwendet wird, ist der Betrieb ohne Einschränkung möglich.
Wird die Abluft durch die Außenwand geleitet, sollte ein Teleskop-Mauerkasten
verwendet werden.
5
Optimale Leistung der Dunstabzugs­haube:
Kurzes, glattes Abluftrohr.Möglichst wenig Rohrbögen.Möglichst große Rohrdurchmesser und
große Rohrbögen.
Der Einsatz von langen, rauhen Abluftrohren, vielen Rohrbögen oder kleineren Rohrdurchmessern führt zu einer Abweichung von der optimalen Luftleistung und gleichzeitig zu einer Geräuscherhöhung.
Rundrohre:
Wir empfehlen Innendurchmesser 150 mm, jedoch mind. 120 mm.
Flachkanäle müssen einen gleichwer-
tigen Innenquerschnitt wie Rundrohre
haben.
Sie sollten keine scharfen Umlenkun­gen haben.
l 120 mm ca. 113 cm
2
l 150 mm ca. 177 cm
2
Bei abweichenden Rohrdurch-
messern: Dichtstreifen einsetzen.
Bei Abluftbetrieb für ausreichend Zuluft
sorgen.
Anschluss Abluftrohr l 150 mm:
Abluftrohr direkt am Luftstutzen
befestigen.
Anschluss Abluftrohr l 120 mm:
Reduzierstutzen auf den Luftstutzen
stecken – Abb. 3 – und dann das Abluftrohr befestigen.
Abluftrohr am Reduzierstutzen
befestigen.
Umluftbetrieb Abb. 4
Mit Aktivkohlefilter, wenn keine
Möglichkeit für Abluftbetrieb vorhanden ist.
Wenn die Dunstabzugshaube für
Umluftbetrieb geeignet ist, können Sie das komplette Montage-Set beim Fachhandel erwerben.
Vor der Montage
Vorbereiten der Wand
Die Wand muss eben und senkrecht
sein.
Für festen Halt der Dübel ist zu sorgen.
Gewicht in kg:
Konstruktionsänderungen im Rahmen der technischen Entwicklung bleiben vorenthalten.
Abluft Umluft
3432
6
Elektrischer Anschluss Einbauen
Die Dunstabzugshaube darf nur an eine vorschriftsmäßig installierte Schutzkontakt­steckdose angeschlossen werden. Die Schutzkontaktsteckdose möglichst direkt hinter der Kaminverblendung anbringen.
Elektrische Daten:
Sie sind auf dem Typenschild nach Abnahme der Filterrahmen – im Innenraum des Gerätes – zu finden.
Bei Reparaturen die Dunstabzugs-
haube generell stromlos machen.
Länge der Anschlussleitung: 1,30 m. Bei erforderlichem Festanschluss:
Die Dunstabzugshaube darf in jedem Fall nur durch einen beim zuständigen Elektrizitäts-Versorgungsunternehmen eingetragenen Elektro-Installateur angeschlossen werden.
Installationsseitig ist eine Trennvorrichtung vorzusehen. Als Trennvorrichtung gelten Schalter mit einer Kontaktöffnung von mehr als 3 mm und allpoliger Abschaltung. Dazu gehören LS-Schalter und Schütze.
Wenn die Anschlussleitung dieses
Gerätes beschädigt wird, muss sie durch den Hersteller oder seinen Kundendienst oder eine ähnlich qualifizierte Person ersetzt werden, um Gefährdung zu vermeiden.
Diese Dunstabzugshaube entspricht den EG-Funkentstörbestimmungen.
Die Dunstabzugshaube ist für die Montage an die Küchenwand vorgesehen.
1. Entfernen Sie die Randabsaugungs­segmente und die Fettfilter (wie in der Gebrauchsanleitung beschrieben).
2. Von der Decke bis zur Unterkante der Dunstabzugshaube eine Mittellinie an die Wand anzeichnen.
3. Mit Hilfe der Schablone Positionen für die Schrauben an der Wand anreißen und zum leichteren Einhängen die Kontur des Einhängebereiches anzeichnen.
Auf Mindestabstand Kochstelle –
Dunstabzugshaube von 550 mm bei Elektro-Kochstellen bzw. 650 mm bei Gas­Kochstellen achten. Der untere Rand der Schablone entspricht dem unteren Rand der Dunstabzugshaube.
4. Löcher für die Dunstabzugshaube und Löcher für die Kaminverblendung bohren und Dübel wandbündig eindrücken. Abb. 5.
5. Die Halterungshaken so anschrauben, dass der abgewinkelte Teil nach aussen zeigt. Abb. 5.
6. Die Halterungschrauben fest anziehen.
7. Das Rückenteil der Dunstabzugshaube
an die Wand halten und in die passenden Löcher einhängen.
8. Mit einem Schraubenzieher die für die horizontale Lage der Haube zuständigen 2 Schrauben langsam anziehen, bis sich die Dunstabzugshaube in einer horizontalen Position über der Kochstelle befindet. Abb. 5 oder 6.
9. Die Sicherheitschrauben hineinstecken und fest anziehen.
7
Einbauen
10. Die Schrauben in die Löcher für den Kaminbügel einstecken und fest anziehen.
11. Elektrische Verbindung herstellen.
12. Rohrverbindung herstellen.
13. Die 2 Teile des Kamins montieren, das
obere Teil mit 2 Schrauben an den Kaminbügel und das untere Teil mit 4 Schrauben an den Haubenkörper.
Umstellen Abluft – Umluftbetrieb
Umstellung der elektronischen Steuerung auf Umluftbetrieb:
Serienmäßige Einstellung ist Abluftbe-
trieb.
Die Dunstabzugshaube muss
angeschlossen und ausgeschaltet sein.
Umstellen:
1. Schalten Sie die Dunstabzugshaube aus
und machen Sie durch Ziehen des Netz­steckers oder Ausschalten der Sicherung die Dunstabzugshaube stromlos.
2. Der LED-Punkt für die Beleuchtung blinkt ca. 10 Sekunden. Drücken Sie innerhalb dieser Zeit 3 x die Taste
a.
Ein akustisches Signal zeigt, dass die elektronische Steuerung auf Umluft­betrieb eingestellt ist.
Abfrage der eingestellten Betriebsart:
1. Schalten Sie die Dunstabzugshaube aus
und machen Sie durch Ziehen des Netz­steckers oder Ausschalten der Sicherung die Dunstabzugshaube stromlos.
Blinkt der LED-Punkt für den Lüfternachlauf
!, ist Umluftbetrieb
eingestellt.
Blinkt der LED-Punkt für die Beleuchtung a, ist Abluftbetrieb eingestellt.
8
Important information
Additional information concerning gas cookers:
When installing gas hotplates, comply
with the relevant national statutory regulations (e.g. in Germany: Technische Regeln Gasinstallation TRGI).
Always comply with the currently valid
regulations and installation instructions supplied by the gas appliance manufacturer.
Only one side of the extractor hood
may be installed next to a high-sided unit or high wall. Gap at least 50 mm.
Minimum distance on gas hotplates
between the upper edge of the trivet and lower edge of the extractor hood: 650 mm, Fig. 1. Recommendation: 700 mm.
Old appliances are not worthless
rubbish. Valuable raw materials can be reclaimed by recycling old appliances. Before disposing of your old appliance, render it unusable.
You received your new appliance in a
protective shipping carton. All packaging materials are environmentally friendly and recyclable. Please contribute to a better environment by disposing of packaging materials in an environmentally-friendly manner.
Please ask your dealer or inquire at your local authority about current means of disposal.
The extractor hood can be used in
exhaust air or circulating air mode.
The applicable regulations of the power
supply company and compliance of local and national building regulations must be observed when installing air extractors (overhead and table top downdraught) in permanent dwellings.
Always mount the extractor hood over
the centre of the hob.
Minimum distance between electric
hob and bottom edge of extractor hood: 550 mm, Fig. 1. Recommendation: 700 mm.
The extractor hood must not be
installed over a solid fuel cooker – a potential fire hazard (e.g. flying sparks) – unless the cooker features a closed, non-removable cover and all national regulations are observed.
The smaller the gap between the
extractor hood and hotplates, the greater the likelihood that droplets will form on the underside of the extractor hood.
Before reading these instructions, please fold out the pages at the back with the illustrations.
This appliance is
labelled in accordance with European Directive 2002/96/EG concerning used electrical and electronic appliances (waste electrical and electronic equipment – WEEE). The guideline determines the framework for the return and recycling of used appliances as applicable throughout the EU.
9
Prior to installation
Exhaust-air mode Fig. 2
The exhaust air is discharged upwards through a ventilation shaft or directly through the outside wall into the open.
D
Exhaust air should neither be directed into a smoke or exhaust flue that is currently used for other purposes, nor into a shaft that is used for ventilating rooms in which stoves or fireplaces are also located.
Exhaust air may be discharged in accordance with official and statutory regulations only (e.g. national building regulations).
Local authority regulations must be observed when discharging air into smoke or exhaust flues that are not otherwise in use.
D
When the extractor hood is operated in exhaust-air mode simultaneously with a different burner which also makes use of the same chimney (such as gas, oil or
coal-fired heaters, continuous-flow heaters, hot-water boilers) care must be taken to
ensure that there is an adequate supply of fresh air which will be needed by the
burner for combustion. Safe operation is possible provided that the
underpressure in the room where the burner is installed does not exceed 4 Pa (0.04 mbar).
Exhaust-air mode Fig. 2
This can be achieved if combustion air can flow through non-lockable openings, e.g. in doors, windows and via the air­intake/exhaust-air wall box or by other technical measures, such as reciprocal interlocking, etc.
If the air intake is inadequate, there is a risk of poisoning from combustion gases which are drawn back into the room.
An air-intake/exhaust-air wall box by itself is no guarantee that the limiting value will not be exceeded.
Note: When assessing the overall requirement, the combined ventilation system for the entire household must be taken into consideration. This rule does not apply to the use of cooking appliances, such as hobs and ovens.
Unrestricted operation is possible if the extractor hood is used in recirculating mode – with activated carbon filter.
If the exhaust air is going to be discharged into the open, a telescopic
wall box should be fitted into the outside wall.
10
Prior to installation
For optimum extractor hood efficiency:
Short, smooth air exhaust pipe.
As few bends in the pipe as possible.
Diameter of pipe to be as large as possible and no tight bends in pipe.
If long, rough exhaust-air pipes, many pipe bends or smaller pipe diameters are used, the air extraction rate will no longer be at an optimum level and there will be an increase in noise.
Round pipes:
We recommend Internal diameter: 150 mm (at least 120 mm).
Flat ducts must have an internal cross­section that equates to that of round pipes.
There should be no sharp bends.
l 120 mm approx. 113 cm
2
l 150 mm approx. 177 cm
2
If pipes have different diameters:
Insert sealing strip.
For exhaust-air mode, ensure that there is an adequate supply of fresh air.
Connecting a l 150 mm exhaust-air pipe:
Mount the pipe directly onto the air outlet on the hood.
Connecting a l 120 mm exhaust-air pipe:
Place the reducing connecting piece
onto the air connecting piece – Fig. 3 – and fasten the exhaust pipe to it.
Attach the exhaust-air pipe to the
reducing connector.
Circulating-air mode Fig. 4
With activated carbon filter if exhaust-air
mode is not possible.
If the extractor hood is suitable for
circulating-air mode, you can purchase the complete installation set at specialist
outlets.
Preparing the wall
The wall must be flat and perpendicular.
Ensure that the wall is capable of providing a firm hold for mounting screws and plugs.
Weight in kg:
We reserve the right to construction changes within the context of technical development.
Exhaust air Recirculating air
3432
11
If it is necessary to wire the extractor hood directly into the mains:
The extractor hood should only be connected to the electricity supply by a properly qualified electrician.
A separator must be installed in the household circuit. A suitable separator is a switch that has a contact gap of more than 3 mm and interrupts all poles. Such devices include circuit breakers and contactors.
If the connecting cable for this
appliance is damaged, the cable must be replaced by the manufacturer or his customer service or a similarly qualified person in order to prevent serious injury to the user.
This extractor hood corresponds to EC regulations concerning RF interference suppression.
Electrical connection
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: Fitting a Different Plug:
The wires in the mains lead are coloured in accordance with the following code:
Green and Yellow – Earth Blue – Neutral Brown – Live
If you fit your own plug, the colours of these wires may not correspond with the identifying marks on the plug terminals.
This is what you have to do:
1.Connect the green and yellow (Earth)
wire to the terminal in the plug marked ‘E’ or with the symbol ( ), or coloured green or green and yellow.
2.Connect the blue (Neutral) wire to the
terminal in the plug marked ‘N’ or coloured black.
3.Connect the brown (Live) wire to the
terminal marked ‘L’, or coloured red.
The extractor hood should only be connected to an earthed socket that has been installed according to relevant regulations.
If possible, site the earthed socket directly behind the chimney panelling.
Electrical data:
Are to be found on the name plate inside the appliance after removal of the filter frame.
Before undertaking any repairs,
always disconnect the extractor hood from the electricity supply.
Length of the connecting cable: 1.30 m.
Installation
This extractor hood is intended to be mounted onto the kitchen wall.
1. Remove the edge extraction segments and the grease filters (as described in the operating instructions).
2. Draw a line on the wall from the ceiling to the lower edge of the hood at the centre of the location where the hood is going to be mounted.
3. Use the template to mark the points on the wall where the screws will be mounted. In order to make it easier to hook the hood onto the screws, draw the outline of the area where the hood will be attached.
Ensure that the minimum distance bet-
ween the hob and the extractor hood is maintained – 550 mm for an electric hob and 650 mm for a gas hob. The bottom edge of the template equates to the lower edge of the extractor hood.
4. Drill holes for the extractor hood and holes for the chimney panelling. Insert plugs into the holes so that they are flush with the wall. Fig. 5.
12
Installation
Changing over from exhaust­air to recirculating mode
05. Screw on the mounting hooks with the
angled part facing outwards. Fig. 5.
06. Screw the support screws.
07. Rest the back of the hood on the wall
and let the hoods enter the corresponding slots.
08. Holding the cross notched screwdriver
in your hand, slowly screw up the 2 horizontal alignment screws, until the hood is perfectly horizontal above the cooker hob. Fig. 5 or 6.
09. Insert and fix with the screw-driver the
safety screws.
10. Insert the screws in the holes of the upper chimney bracket and screw them in the plugs.
11. Connect the hood to electricity supply.
12. Connect the air outlet pipe.
13. Mount the two parts of the chimney
fixing on the side the upper part with 2 screws at the chimney bracket and the lower part with 4 screws at the body of the hood.
Changing the electronic control system to recirculating mode:
The standard factory setting is for operation in exhaust-air mode.
To change the mode, the extractor hood must have been connected up and should be switched off.
Change over procedure:
1. Switch off the extractor hood and pull
out the mains plug or switch off the electricity supply at the fuse box.
2. The lighting LED flashes for about ten seconds. In this time, press the
a button
three times. You will hear a signal when the electronic control system is set to recirculating mode.
Determining the set mode:
1. Switch off the extractor hood and pull
out the mains plug or switch off the electricity supply at the fuse box.
When the fan follow-on LED
!
flashes, recirculating mode is active.
When the lighting LED
a flashes,
exhaust air mode is active.
13
Remarques importantes
Remarques supplémentaires concernant les cuisinières à gaz:
Lors du montage de foyers gaz, veuillez
respecter les dispositions légales en vigueur dans votre pays (En Allemagne par ex: les Règles technique TRGI régissant l'installation du gaz).
Respectez les prescriptions et
consignes d'encastrement en leur version applicable publiées par les fabricants d'appareils au gaz.
La hotte aspirante ne pourra cotoyer
que sur un côté un meuble haut ou une paroi haute. Ecart minimum: 50 mm.
Ecart minimum, en présence de
foyers au gaz, entre le bord supérieur de la grille support et le bord inférieur de la hotte: 650 mm, fig. 1.
Les anciens appareils ne sont pas des
déchets sans valeur. Leur élimination respectueuse de l'environnement permet de récupérer de précieuses matières premières. Avant de vous débarrasser de l'appareil, rendez-le inutilisable.
Pour vous parvenir en parfait état, votre
nouvel appareil a été conditionné dans un emballage qui le protège efficacement. Tous les matériaux d'emballage utilisés sont compatibles avec l'environnement et recyclables. Aidez-nous à éliminer l'emballage en respectant l'environnement.
Demandez à votre revendeur ou à votre mairie quelles sont les formes de recyclage actuellement possibles.
Cette hotte peut évacuer l'air à
l'extérieur ou le recycler.
Fixez toujours la hotte bien centrée
au-dessus des foyers de la table de cuisson.
L'écart minimum entre les foyers
électriques et le bord inférieur de la hotte doit être de 550 mm, voir fig. 1.
Au-dessus d'un foyer à combustible
solide générateur d'un risque d'incendie (par projection d'étincelles par ex.), le montage de la hotte ne sera admis que si ce foyer est équipé d'un couvercle fermé et inamovible et si le montage ne contrevient pas à la réglementation nationale. Cette restriction ne vaut pas pour les cuisinières à gaz et les foyers aux gaz.
Plus l'écart est faible entre la hotte
aspirante et les foyers et plus il se pourra que la vapeur montant des casseroles se condense et forme des gouttes sur la face inférieure de la hotte.
Cet appareil est marqué
selon la directive euro­péenne 2002/96/CE relative aux appareils élec­triques et électroniques usagés (waste electrical and electronic equipment– WEEE). La directive définit le cadre pour une reprise et une récupération des appareils usagés applicables dans les pays de la CE.
Avant de lire ce qui suit, veuillez déplier les volets illustrés en fin de notice.
14
Avant le montage
Evacuation de l'air à l'extérieur Fig. 2
L'air vicié est évacué vers le haut par un conduit d'aération ou directement à l'air libre par traversée du mur extérieur.
D
L'air vicié ne doit jamais être évacué vers une cheminée en service, rejetant des fumées ou des gaz de combustion, ni vers un conduit servant à l'aération de locaux dans lesquels se trouvent des foyers à combustibles solides, liquides et gazeux.
Le mode d'évacuation de l'air vicié devra être conforme aux arrêtés municipaux, préfectoraux, et aux prescriptions légales (par ex. aux ordonnances publiques applicables au bâtiment).
Si l'air vicié doit être évacué par des cheminées d'évacuation des fumées et gaz de combustion qui ne sont pas en service, veuillez respecter la réglementation locale et nationale applicable.
D
Si la hotte évacue l'air à l'extérieur et si le logement comporte des moyens de chauffage (tels par ex. des appareils de
chauffage au gaz, au fuel ou au charbon, chauffe-eau instantanés ou à accumulati­on) raccordés à une cheminée, veiller
impérativement à ce que l'apport d'air soit suffisant pour assurer la marche du
chauffage à combustion. Un fonctionnement sans risque est possi-
ble si la dépression dans le local où le foyer de chauffage est implanté ne dépasse pas 4 Pascals (0,04 mbars).
Evacuation de l'air à l'extérieur Fig. 2
On y parvient en présence d'ouvertures non obturables ménagées par ex. dans les portes, fenêtres et en association avec des ventouses télescopiques d'admission/ évacuation de l'air à travers la maçonnerie ou par d'autres mesures techniques telles qu'un verrouillage réciproque ou assimilé permettant à l'air d'affluer pour assurer la combustion.
En cas d'afflux d'air insuffisant, risque d'intoxication par réaspiration des gaz de combustion.
La présence d'une ventouse télescopique d'apport et d'évacuation d'air ne suffit pas à assurer le respect de la valeur limite.
Remarque: lors de l'évaluation de la situati­on, toujours tenir compte de l'ensemble des moyens d'aération du logement. Cette règle ne vaut généralement pas si vous uti­lisez des appareils de cuisson (table de cuisson et cuisinière à gaz).
Si la hotte recycle l'air aspiré au moyen d'un filtre au charbon actif, son fonctionnement ne s'assortit d'aucune restriction.
Si l'air vicié traverse le mur extérieur,
utilisez une ventouse télescopique.
15
Avant le montage
Mode Air recyclé Fig. 4
Avec filtre à charbon actif, lorsqu'il n'est
pas possible d'évacuer l'air aspiré par la hotte.
Si la hotte aspirante convient pour
fonctionner en mode Recyclage, vous pouvez vous procurer l'ensemble du kit de montage auprès du commerce
spécialisé.
Pour que la hotte aspirante ait le meilleur rendement, veillez à ce que:
Le conduit d'évacuation soit court et lisse.
Il ait le moins possible de coudes.
Il ait le plus fort diamètre et que les coudes soient les plus arrondis possibles.
L'emploi de conduits d'air vicié longs, rugueux, formant de nombreux coudes ou d'un trop petit diamètre fait descendre le débit d'air en dessous du débit optimal, tout en accroissant le bruit d'aspiration.
Conduits de section ronde:
Nous recommandons recommandons des conduits au diamètre intérieur de 150 mm mais de 120 mm minimum.
Les conduits plats doivent avoir une section intérieure équivalente au
diamètre intérieur des conduits ronds.
Les conduits ne doivent comporter aucun coude prononcé.
120 mm l = 113 cm
2
de section
150 mm l = 177 cm
2
de section.
Si les conduits ont des diamètres différents: utilisez du ruban adhésif à
étancher.
Si la hotte évacue l'air à l'extérieur,
veillez à ce que l'apport d'air soit suffisant.
Branchement du conduit d'évacuation l 150 mm:
Fixez le conduit d'évacuation directement sur l'orifice.
Branchement du conduit d'évacuation l 120 mm:
Introduisez le manchon réducteur sur le
manchon à air (fig. 3) et puis fixez le tuyau d’ air vicié contre le premier.
Fixez le tuyau d'air vicié contre le
manchon réducteur.
Préparation du mur
Le mur doit être bien plat et vertical.
Utilisez des chevilles pour assurer une retenue ferme.
Poids en kg:
Sous réserve de modifications constructives dans l’intérêt du progrès technique.