NEC PlasmaSync 42XM2/S Installation Guide

NEC Solutions (America), Inc.
Visual Systems
42XM2/S (Residential Model) Installation Guide

42” Plasma Displays v1.1

Contents

Product Description and Notes Page 1 Ventilation Requirements
Display Dimensions Front, Top & Bottom
Rear & Sides Display Dimensions w/Optional Speakers and Stand Dimensions w/Optional Flat Wall Mount Dimensions w/Optional Tilt Wall Mount Dimensions w/Optional Ceiling Mount Connections Control Codes

Product Description

Type: Plasma Display Screen Surface: Anti-Reflective Resolution: 1024x768 (XGA) Color Correction: NEC CCF (Capsulated Color Filter, in panel) Aspect Ratio: 16:9 and AccuCrimson (in front filter) FCC: Class B Dimensions: 40(W) x 24(H) x 3.5(D) DVI Input: HDCP capable Weight: 65.0 lbs

Notes

This document is intended to be used as a reference guide to supply useful information for a design or installation. It is not
intended to be a step-by step procedure for installation.
Any ceilings or walls must be strong enough to support the display and the installation must be in accordance with any local
building codes. All mounts should make secure contact to wood studs.
4:3 sources can be displayed on the 16:9 screen in either normal aspect ratio with bars on the left or right, or stretched
horizontally to fill the screen using the menus (see “Aspect Modes” in menus and user manual).
Distances are in inches, for millimeters multiply by 25.4.  Distances may vary ±5%.

Maximum Tilt Angles

Below is the maximum angle that the display can be tilted Landscape 30°
Max Tilt
www.necvisualsystems.com 42XM2/S Page 1 of 10
Ventilation Requirements (all models)
Dimensions below are minimum required for proper ventilation.
2"
NOTE: The ventilation space should not be covered or closed off at the front of the opening. If for some reason the opening needs to be covered, other means of ventilation will need to be incorporated into the design. Contact NEC for design review and recommendations.
www.necvisualsystems.com 42XM2/S Page 2 of 10
WALL
WALL
2"
2"
WALL
2"
2"
Display dimensions
0.98
2.52
0.63 1.69
3.11
Ventilation Openings
3.95
0.38
0.79
Ventilation Openings
23.27
34.55
40.08
36.76 Ventilation Openings
33.25
33.03
2.70
0.81
16.81
0.38 1.69 0.6334.690.381.690.63
1.42
0.59
Ventilation Openings
2.72
3.50
5.53
1.30
0.63
1.14
1.38
0.35
1.38
0.98
1.14
0.98
24.02
2.171.34
www.necvisualsystems.com 42XM2/S Page 3 of 10
Display dimensions (cont.)
4.13
6.06 12.83 5.12
9.61 20.87 9.61
1.67
1.77
4.02
Ventilation Openings
8.78 1.65 19.21 1.65 8.78
Ventilation Openings
For PC Option
AC IN
Ventilation Openings
0.40
0.06
0.39
23.11
0.39
0.40
0.06
17.52
M4*10 MAX
Ventilation Openings
+- +-
1.67
1.77
4.02
Ventilation Openings
3.50
1.97
°
0.37
5
.
1
VIDEO 3
1.57
VIDEO
(IN/OUT)
VIDEO 1
VIDEO 2
AUDIO 1
R
L
YCb/PbCr/Pr
DVD 1/HD 1
AUDIO 2
L
R
R/
Cr/Pr
G/
Y Cb/Pb HD VD
RGB 2/DVD 2/HD 2 RGB 1
B/
(IN/OUT)
AUDIO 3
R
L
DVI
RGB 3
External Control
REMOTE
OUTIN
8-M4*14MAX
For Mount
4.25 4.96 5.12 4.96 4.72
0.640.68
22.06
0.51
0.63
www.necvisualsystems.com 42XM2/S Page 4 of 10
Dimensions with optional speakers and stand
3.54
0.02
4.41
0.75
0.53
13.58
11.42
1.30
47.20
Optional Speakers
13.58
11.42
4.37
4.41
0.02
1.97
3.54
26.59
14.59
2.58
15.75
7.28 4.96
www.necvisualsystems.com 42XM2/S Page 5 of 10
Dimensions with optional Flat Wall Mount Kit (FWMK)
.
6
2
Note: The mount holes are higher on the 42XM2/S than on prior models due to a higher center of gravity. (mount pattern is the same) 42XM2/S mount holes are 0.24” higher than 42PD3(PX-42VP3) 42XM2/Smount holes are 0.83” higher than 42MP3(PX-42V3)/42MP4(PX-42XM1)
0
.
2
.
3
5
5
1
1
8
.
0
.
2
1
0
4
.
0
1
.
6
0
8
.
9
9
.
5
4
.
8
4
.
0
8
.
1
.
2
1
1
www.necvisualsystems.com 42XM2/S Page 6 of 10
Dimensions with optional Tilt Wall Mount Kit (TWMK)
Tilt Range
Note: The mount holes are higher on the 42XM2 than on prior models due to a higher center of gravity. (mount pattern is the same) 42XM2/S mount holes are 0.24” higher than 42PD3(PX-42VP3) 42XM2/S mount holes are 0.83” higher than 42MP3(PX-42V3)/42MP4(PX-42XM1)
5
5
.
8
4
0
.
5
°
0
.
5
1
12.1
Depth at 15° Tilt
1
5
.
3
0
.
6
1
.
8
1
.
2
1
0
.
4
1
7
.
9
9
.
5
4
.
8
0
.
4
0
.
8
0
.
2
1
www.necvisualsystems.com 42XM2/S Page 7 of 10
Dimensions with optional Ceiling Mount Kit (CMK)
Note: The mount holes are higher on the 42XM2/S than on prior models due to a higher center of gravity. (mount pattern is the same) 42XM2/S mount holes are 0.24” higher than 42PD3(PX-42VP3) 42XM2/S mount holes are 0.83” higher than 42MP3(PX-42V3)/42MP4(PX-42XM1)
1.5
2.5
0.5
12.2
16.0 12.0
-+
+
-
LEFTRIGHT { SPEAKERS MUST
AC IN
HAVE MORE THAN 7WATT RATING
IMPEDANCE 6 OHM}
8.717.5
www.necvisualsystems.com 42XM2/S Page 8 of 10
Connections
DVI Input is HDCP capable
VIDEO 3
(MONO)
L
(MONO)
L
(MONO)
L
(IN/OUT)
VIDEO 1
YCb/PbCr/Pr
Cr/Pr Y Cb/Pb HD VD
R/ G/ B/
(IN/OUT)
DVI
(Digital RGB)
VIDEO
VIDEO 2
AUDIO 1
R
DVD 1/HD 1
AUDIO 2
R
RGB 2/DVD 2/HD 2
RGB 1
AUDIO 3
R
RGB 3
External Control
REMOTE
OUTIN
LOCATED AT BOTTOM OF DISPLAY
POWER
EXT. SPEAKERS
www.necvisualsystems.com 42XM2/S Page 9 of 10
Control Codes

Function Code Data

POWER ON 9FH 80H 60H 4EH 00H CDH OFF 9FH 80H 60H 4FH 00H CEH INPUT SWITCH VIDEO1 (BNC) DFH 80H 60H 47H 01H 01H 08H VIDEO2 (RCA) DFH 80H 60H 47H 01H 02H 09H VIDEO3 (S-Video) DFH 80H 60H 47H 01H 03H 0AH DVD1/HD1 (RCA/Component) DFH 80H 60H 47H 01H 05H 0CH DVD2/HD2 (5BNC/Component) DFH 80H 60H 47H 01H 06H 0DH RGB1 (15pin HD) DFH 80H 60H 47H 01H 07H 0EH RGB2 (5BNC/RGB) DFH 80H 60H 47H 01H 08H 0FH RGB3 (DVI) DFH 80H 60H 47H 01H 0CH 13H AUDIO MUTE ON 9FH 80H 60H 3EH 00H BDH OFF 9FH 80H 60H 3FH 00H BEH PICTURE MODE NORMAL DFH 80H 60H 0AH 01H 01H CBH THEAT.1 DFH 80H 60H 0AH 01H 02H CCH THEAT.2 DFH 80H 60H 0AH 01H 03H CDH DEFAULT DFH 80H 60H 0AH 01H 04H CEH SCREEN MODE: STADIUM DFH 80H 60H 51H 01H 02H 13H ZOOM DFH 80H 60H 51H 01H 03H 14H NORMAL DFH 80H 60H 51H 01H 04H 15H FULL DFH 80H 60H 51H 01H 05H 16H AUTO PICTURE ON DFH 80H 60H 7FH 03H 03H 09H 00H 4DH OFF DFH 80H 60H 7FH 03H 03H 09H 01H 4EH CINEMA MODE ON DFH 80H 60H C1H 01H 01H 82H OFF DFH 80H 60H C1H 01H 02H 83H
NOTE: Contact your NEC rep for codes not listed. NOTE: Use a cross/reverse/null modem cable.
Cable Connection
Communication Protocol:
Interface: RS-232C Parity: Odd Communication: Asynchronous Stop Bit: 1 bit Baud Rate: 9600 bps Communication Code: Hex Data Length: 8 bits
PC Control Connector (D-Sub 9P)
To TxD of PC
To RxD of PC
To GND of PC
12
34
5
67 8
9
To RTS of PC To CTS of PC
NOTE: Jumper “Request to send” and “Clear to Send” together on both ends of the cable to simplify cable connection.