NEC NP-M260X Quick Start Manual

NEC Display Solutions of America, Inc.
M260X/M300X Installation Guide
Ceiling Mounted and Desktop Rev 1.1

Contents

Product Description, Lens Specs, Notes and Formulas Pg 1 Diagrams & Distance Charts Cabinet Dimensions Ceiling Mount Dimensions Input Panel and Control Codes
Product Description
Type: 3 panel LCD projector, Dimensions: 13.3” (W) x 3.9” (H) x 10.1” (D) M300X: 0.63” p-Si TFT w/MLA Weight: 6.4 lbs M260X: 0.63” p-Si TFT Resolution: 1024 x 768 Brightness: M300X - 3000 Lumens Fan Noise: 34 dB / 27dB @ 1 meter M260X - 2600 Lumens
Power Consumption: M260X/M300X 248W (max) BTU’s: 846 BTU/hour
Lens Specifications
Throw Ratio: 1.3 – 2.2:1 (for 100” diagonal) Focal Length: 17.5mm 29.0mm Offset Angle: 6.5° - 10.8° (for 100” diagonal) F/#: 1.7 - 2.1 Screen Sizes: 21” - 300” diagonal (4:3) Manual Focus/Manual Zoom
Notes
For screen sizes not indicated on the projection tables, use the formulas below.
If the figures on the tables do not match the results of formulas, use the figures in the table.
All calculations are based on a 4:3 aspect ratio.  Distances are in inches, for millimeters multiply by 25.4.  Distances may vary 5%.
Formulas
The Projection Formulas use the image width for calculation. For proper projection placement, determine the image width for the desired screen size. Use the Screen Formulas below to calculate all screen dimensions. Plug in the width for “W” in the Projection Formulas. Refer to the diagrams and charts for popular screen sizes on page 2:
Definitions: 4:3 Screen Formulas:
W = Image Width W = H x 4/3 H = Image Height (size) H = W x 3/4 B = Vertical distance between lens center and screen center Screen Diagonal = W x 5/4 C = Throw distance D = Vertical distance between lens center and screen top (screen bottom for desktop application)
Projection Formulas: B = 0.258W C (wide) = 1.366W – 1.77 C (tele) = 2.268W – 1.77 D = -0.117W
α (wide) = tan¯¹ (B/C(wide)) α (tele) = tan¯¹ (B/C(tele))
www.necdisplay.com M260X/M300X Page 1 of 6
Pg 2 Pg 3-4 Pg 5 Pg 6
NEC Display Solutions of America, Inc.
M260X/M300X Installation Guide

Ceiling Mounted and Desktop Rev 1.1 Diagrams and Distance Charts

The following shows the proper relative positions of the projector and screen. Refer to the table to determine the position of installation. Distances are in inches. For millimeters multiply by 25.4.
Ceiling Mounted
Desktop
Distance Chart for po
pular 4:3 screens
Note: For screen sizes not indicated on the projection
tables, use the formulas on page 1.
4.56"
5.17"
Lens Offset From Mount Pipe
2.79
2.22"
Screen Size (4:3)
Diagonal Width(W) Height ( H)
inches inches inches inches
30 24 18 6 31 - 53 11.3 - 6.7
60 48 36 12 64 - 107 11.0 - 6.6
67 53.6 40.2 14 72 - 120 10.9 - 6.6
72 57.6 43.2 15 77 - 129 10.9 - 6.6
84 67.2 50.4 17 90 - 151 10.9 - 6.6
90 72 54 19 97 - 162 10.9 - 6.6
100 80 60 21 108 - 180 10.9 - 6.6
120 96 72 25 130 - 216 10.8 - 6.5
150 120 90 31 162 - 270 10.8 - 6.5
180 144 108 37 195 - 325 10.8 - 6.5
210 168 126 43 228 - 379 10.8 - 6.5
240 192 144 50 261 - 434 10.8 - 6.5
270 216 162 56 294 - 488 10.7 - 6.5
300 240 180 62 327 - 543 10.7 - 6.5
C
Throw Distance
C
Throw Distance
B
C
w ide - tele
inches
D
inches
-3
-6
-6
-7
-8
-8
-9
-11
-14
-17
-20
-22
-25
-28
Screen Top
D
Lens Ctr
B
Screen Ctr
Screen Ctr
B
Lens Ctr
D
Screen Bottom
α
w ide - tele
degrees
www.necdisplay.com M260X/M300X Page 2 of 6
NEC Display Solutions of America, Inc.
M260X/M300X Installation Guide
Ceiling Mounted and Desktop Rev 1.1

Cabinet Dimensions

The following drawings show the cabinet dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
Lamp
Zoom Lever
Focus Lever
Exhaust Lens Cover
Lens Center
Lens Center
e
r
k
e a t
ilt n
F
I
www.necdisplay.com M260X/M300X Page 3 of 6
NEC Display Solutions of America, Inc.
M260X/M300X Installation Guide
Ceiling Mounted and Desktop Rev 1.1

Cabinet Dimensions (continued)

The following drawings show the cabinet dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
IR Receiver
Lens Center
4 - M4*8 Max
for Ceiling Mount Kit
www.necdisplay.com M260X/M300X Page 4 of 6
NEC Display Solutions of America, Inc.
M260X/M300X Installation Guide
Ceiling Mounted and Desktop Rev 1.1

Optional Ceiling Mount Dimensions (Model #: MP300CM)

The following drawings show the ceiling mount dimensions. Dimensions are in inches. For millimeters multiply by 25.4.
www.necdisplay.com M260X/M300X Page 5 of 6
NEC Display Solutions of America, Inc.
M260X/M300X Installation Guide
Ceiling Mounted and Desktop Rev 1.1

Input / Output Panel

PC Control Codes

Function Code Data

POWER ON 02H 00H 00H 00H 00H 02H POWER OFF 02H 01H 00H 00H 00H 03H INPUT SELECT COMPUTER1 02H 03H INPUT SELECT COMPUTER21 INPUT SELECT HDMI 02H 03H 00H 00H 02H 01H 1AH INPUT SELECT VIDEO 02H 03H INPUT SELECT S-VIDEO 02H 03H INPUT SELECT VIEWER 02H 03H INPUT SELECT NETWORK 02H 03H INPUT SELECT USB DISPLAY 02H 03H PICTURE MUTE ON 02H 10H PICTURE MUTE OFF 02H 11H 00H 00H 00H 13H SOUND MUTE ON 02H 12H 00H 00H 00H 14H SOUND MUTE OFF 02H 13H PROJECTOR INFORMATION REQUEST 00H BFH 00H 00H 01H 02H C2H ERROR STATUS REQUEST 00H 88H 00H 00H 00H 88H INFORMATION REQUEST 03H 8AH 00H 00H 00H 8DH
02H 03H 00H 00H 02H 01H 02H 0AH
00H 00H 02H 01H 01H 09H
00H 00H 02H 01H 06H 0EH 00H 00H 02H 01H 0BH 13H 00H 00H 02H 01H 1FH 27H
00H 00H 02H 01H 20H 28H
00H 00H 02H 01H 22H 2AH 00H 00H 00H 12H
00H 00H 00H 15H

Note: Contact your NEC rep for codes not listed.

Cable Connection
Communication Protocol:
Baud Rate: 38400 bps
To TxD of PC To RxD of PC
To GND of PC
Data Length: 8 bits
12
34
Parity: No Parity
5
Stop Bit: One Bit X on/off: None
67 8
Communications: Full duplex
PC Control Connector (D-Sub 9P)
9
To RTS of PC To CTS of PC
NOTE 1 : Pins 1, 4, 6, and 9 are used in side the projector. NOTE 2: For long cable runs it is recommended to set communication speed within the projector to 9600 bps. NOTE 3: Jumper “Request to Send” and “Clear to Send” together on both ends of the cable to simplify cable connection.
www.necdisplay.com M260X/M300X Page 6 of 6
22H