21.3” grayscale medical-grade LCD displays ideal for diagnostic imaging
www.necdisplay.com
Modern medical technology enables complex examinations. But in
the end, it is the radiologist who is responsible for fast and accurate
diagnostic findings. To support these findings in a soft copy reading environment, flat-panel displays need to comply with the highest
visual requirements. Their image quality has a decisive influence on
diagnostic accuracy.
MultiSync MD Series grayscale displays – in combination with the
appropriate graphics controller – are designed for diagnostic imaging
and for use in Picture Archiving and Communication System (PACS)
applications. Furthermore, diagnostic imaging displays from NEC
Display Solutions are based on technologies and functions which
actively contribute to a reduction of cost of ownership.
Figure 1.
9
1
2
3
4
5
X-Light technology - a view
behind the screen
1 LCD panel
2 Polariser diffusing plate, etc.
3 Light guide plate
4 Color sensor
5 Temperature sensor
6 Current data of color sensor and
temperature sensor
7 Control of 3 inverters
8 Calibration of whitepoint via
pre-calibration in factory, software
(GammaComp MD) or reference
value of external sensor
9 Light sources, white light using a
mixture of different phosphor
colors
Factory calibration and
consistency. Using state-
of-the-art equipment
during production, each
NEC MultiSync MD Series
as it enables a more flexible use of display equipment. Since all
X-Light-equipped monitors are set for the same whitepoint during production, they can be exchanged at any time within one
location and swapped in existing dual- or multi-screen configu-
rations without calibration.
monitor is calibrated to the
DICOM display function
for luminance and to a
8
desired whitepoint (color
of the white). NEC Display
1) has the unique ability
to control and adjust the
luminance and whitepoint
6
via an integrated fast-feedback internal backlight
sensor, which continuously
monitors and realigns
these settings to maintain
the factory calibration
throughout the life of the
monitor. X-Light technology also alleviates the
color shift of the backlight
to the yellow spectrum.
Standalone calibration and monitor matching. NEC MultiSync
MD Series monitors have been designed to maintain their fac-
tory calibration. However, if calibration or matching (Fig. 2) to
a replacement is required, the monitors can be configured using
the built-in, standalone algorithm programmed into the monitor’s
firmware. This feature is useful for monitors that are not used in
a setup where calibration can easily be performed with a PC and
external software or non-supported
operating systems.
GammaComp™ MD calibration and
conformance software. Quality control
and calibration/matching can also
be accomplished using GammaComp
Figure 2.
USB
RESULT OF
MEASUREMENT
Target:
Luminance
400 cd/m
x cord 0.265
y cord 0.320
MD (shipped with display), ensuring
consistent image quality on a single
display system. The software main-
Source Display
Target Display
tains the monitor’s conformance to the
DICOM standard, while providing an
easy-to-use QA environment for medi-
2
USB
cal imaging. Optionally, GammaComp
Monitor matching and reduced downtime. X-Light
helps reduce service costs
MD Administrator provides centralized
control and management of multiple
display systems.
Display matching in the field
3061 shades of gray. 1024 shades
of gray out of a palette of 3061 can
be depicted when used with a 10-bit
video card.
1
Onboard selectable look-up tables
(LUTs). The LUT for adjustment
is built into the monitor, making
2
it independent of the video card.
The monitor’s gamma is factory
set to the DICOM GSDF standard,
but custom gamma settings can be
selected using the built-in LUTs.
4
A typical NEC MultiSync MD
Series display system configuration
1 Single or dual head displays
2 Display controller board
3 GammaComp MD quality
control software
4 Calibrator (optional)
3
SA Superfine TFT displays with
anti-glare and low reflection. The
innovative SA Superfine TFT glass
with 2- or 3-Megapixel resolution
delivers a brilliant picture with a
wide viewing angle of up to 176°
and minimal off-angle color shift.
Therefore, it provides the best conditions for several doctors doing
consultation in front of the display.
Mutiple video card support. NEC MultiSync MD Series monitors
work with 10-bit or 8-bit cards, however, 10-bit is recommended
for optimum performance. 10-bit provides 1024 out of 3061
shades, while 8-bit provides only 256 out of 3061.
Internal power supply. The NEC MultiSync MD Series features an
internal power supply. There is no brick to kick, therefore, clutter
from a clunky power supply is eliminated.
lengthens the life of the screen by fending off scratches caused
by surface contact. The 98.5% transparent shield features antireflective coating on both sides, anti-fingerprint coating on the
outside layer, a hard coat for ruggedness and excellent permanent marker resistance.
SentryDX remote network sensor. For non-assisted confor-
mance, calibration and reporting functions, an optional,
retractable remote sensor (Fig.
4) is available for NEC MultiSync MD Series displays. This
component, which also can be
used with non-MD Series monitors, is capable of measuring
monitor brightness, whitepoint
and ambient lighting, while
performing a quality check for DICOM conformance and contrast response.
GammaComp MD colorimeter. Featuring perfectly matched coding for NEC MultiSync MD Series
displays, this allows for improved accuracy and
communication to the display and provides an
ideal solution for radiology technicians. Working
in conjunction with X-Light, the sensor (Fig. 5)
also supports standalone calibration and exact
monitor matching, while enhancing calibration and whitepoint matching for better DICOM
GSDF conformance.
Figure 5.
GammaComp
MD colorimeter
Optional accessories. To add further performance and conve-
nience, these accessories are available for the NEC MultiSync
MD Series.
Protective shield. As these displays are often used by diagnostic
professionals for illustration purposes, it is common for them
to encounter frequent
contact from fingers,
pointers and pens. To
help protect against LCD
screen damage while
maintaining the display’s
optimal image quality, an
optional protective shield
(Fig. 3) is available. This
lightweight accessory,
which is quickly and eas-
Figure 3. Attachable protective shield
ily attached and removed,
* Each end-user environment is unique, therefore NEC Display Solutions
recommends that the user follows the quality control and calibration
When combined with an NEC MultiSync 90 Series display (left), NEC
MultiSync MD Series monitors can help provide an ideal PACS configuration for your facility.
Model
LCD Viewable Image Size
LCD Module Technology
Active Screen Area
Native Resolution
Pixel Pitch
Brightness at Native (typical)
Contrast Ratio (typical)
Response Time (typical)
Viewing Angle (typical) (up/down/left/right)
Grayscale Tone
43.2 x 32.4 cm
1600 x 1200 Landscape/1200 x 1600 Portrait
0.27mm
900 cd/m2 (263 fl) max, 400 cd/m2 (117 fl) calibrated
700:1
35ms
88°/88°/88°/88°
10-bit: 1024 shades of gray from a pallet of 3061
DVI-D and VGA
DICOM, log-linear, 2.2, 1.8 and programmable
Clear base x=.292, y=.321, Approx. 8000 K
Yes / Yes / Yes
Yes
65W
<3W
25° up/5° down, 340°
46mm
Yes
100 x 100mm
GammaComp MD sensor (calibration mode)
18.4 x 18.1 x 7.9 in. (Landscape)
14.1 x 20.2 x 7.9 in. (Portrait)
16mm
25.8 lbs.
UL2601/EN60601-1/EC601, FCC part 15 class B, CE/MDD,
PCT, C-tick, PCBC/B Mark, PSB, EnergyStar, GEEA Energy
Label, DIN 6868-57, FDA-510K
MD21PS-BK
MDM10B-2MP
DX
Sentry
(MD-N2M5B)
GammaComp MD Sensor (MDSVSENSOR)
3 years, parts and labor (includes Advanced Overnight
Exchange)*
EW1-MD2MP21 / EW2-MD2MP21
MultiSync MD21GS-3MP
21.3"
SA-Superfine Grayscale TFT Glass
43.3 x 32.5 cm
2048 x 1536 Landscape/1536 x 2048 Portrait
0.21mm
700 cd/m2 (204 fl) max, 400 cd/m2 (117 fl) calibrated
700:1
35ms
88°/88°/88°/88°
10-bit: 1024 shades of gray from a pallet of 3061
DVI-D
DICOM, log-linear, 2.2, 1.8 and programmable
Clear base x=.292, y=.321, Approx. 8000 K
Yes / Yes / Yes
Yes
65W
<3W
25° up/5° down, 340°
46mm
Yes
100 x 100mm
GammaComp MD sensor (calibration mode)
18.4 x 18.1 x 7.9 in. (Landscape)
14.1 x 20.2 x 7.9 in. (Portrait)
16mm
25.8 lbs.
UL2601/EN60601-1/EC601, FCC part 15 class B, CE/MDD,
PCT, C-tick, PCBC/B Mark, PSB, EnergyStar, GEEA Energy
Label, DIN 6868-57, FDA-510K
MD21PS-BK
MDM10B-3MP
DX
Sentry
(MD-N2M5B)
GammaComp MD Sensor (MDSVSENSOR)
3 years, parts and labor (includes Advanced Overnight
Exchange)*
EW1-MD3MP21 / EW2-MD3MP21
Display video card
Graphics Chip
Memory Type
Memory Size
Main RAMDAC
Secondary RAMDAC
Card Type
Form Factor
Maximum Resolution
Connectors
Certifcations
Limited Warranty
MultiSync is a registered trademark, and GammaComp, NaViSet and
X-Light are trademarks of NEC Display Solutions. All other brand or
product names are trademarks or registered trademarks of their respective holders. Product specifications subject to change. 3/08 Ver. 3.
* Limited to a luminance setting up to 450 cd/m2 with guaranteed chromaticity match (whitepoint) +/- .01 of CIE x,y, of original factory
setting via X-Light technology
NOTE 1: American College of Radiology (ACR) recommends minimum of 171 cd/m2
MDM10B-2MP
Matrox 512-bit GPU
DDR (Double Data Rate) SDRAM
256 MB
400 MHz
400 MHz
PCI 64-bit, 66 MHz
ATX
1920 x 1200 (digital / analog)
2 x DVI-I
Class A: FCC, CE, CSA, VCCI
1 year
MDM10B-3MP
Matrox 512-bit GPU
DDR (Double Data Rate) SDRAM
256 MB
400 MHz
400 MHz
PCI 64-bit, 66 MHz
ATX
2048 x 1536 (digital)
2 x DVI-I
Class A: FCC, CE, CSA, VCCI
1 Year
NEC Display Solutions
500 Park Boulevard, Suite 1100
Itasca, IL 60143
866-NEC-MORE
MDM10B-AVX3MP
Matrox 256-bit GPU
DDR (Double Data Rate) SDRAM
128 MB
400 MHz
165 MHz
PCIe x16, low profile
Low profile
1600 x 1200 (analog); 2048 x 1536 (digital)
3 x DVI-I (1 analog, 2 digital)
Class A: FCC, CE, CSA, VCCI
1 Year
Loading...