NEC FE750 Schema

PART NO. 599910513
SCHEMATIC DIAGRAMS
COLOR MONITOR
MultiSync
!!!!
FE750
MODELS FE750 (A) / (B) /(R)
NEC Corporation

WARNING

The SERVICE PERSONNEL should have the appropriate technical training, knowledge and experience necessary to:
Be familiar with specialized test equipment, and
Be careful to follow all safety procedures associated with high voltage CRT circuit designs to minimize
danger to themselves and their coworkers.
To avoid electrical shocks, this equipment should be used with an appropriate power code and be connected only to a properly grounded AC outlet.
This equipment utilized a micro-gap power switch. Turn off the set by first pushing the front panel power switch. Next, remove the power cord from the AC outlet.
To prevent fire or shock hazards, do not expose this unit to rain or moisture.
This symbol warns the personnel that un-insulated voltage within the unit may have sufficient magnitude to cause electric shock.
This symbol alerts the personnel that important literature concerning the operation and maintenance of this unit has been included. Therefore, it should be read carefully in order to avoid any problems.

PRODUCT SAFETY CAUTION

1. When parts replacement is required for servicing, always use the manufacturer's specified replacement.
2. Comply with all caution and safety-related notes on the product display chassis and picture tube.
3. When replacing the component, always be certain that all the components are put back in the place.
4. When servicing display monitor unit, it is required that the provided le ad dress is used in the high voltag e circuit area.
5. It is also rec ommended that shatter pro of goggles are worn, when r emoving installing and handling the picture tube. People not equipped with the proper precautionary measures mentioned should keep the picture tube away from body while handling.
6. As for a connector, pick and extract housing with fingers properly since a disconnection and improper contacts may occur, when wires of the connector are led.
7. Use a proper screwdriver. If you use screwdriver that does not fit, you may damage the screws.
8. X-radiation precaution This product contains critical electrical and mechanical parts essential for X-ray protection. Normal anode voltage is 25. 0 kV at zero beam picture tube current under AC 10 0-120V /220-240 V inp ut,
and anode voltage must not exceed the voltages shown below under any operation condition. To measure anode voltage set brightness for very dim picture, and use a high impedance volt meter
between chassis and anode lead and measure high voltage. If high voltage exceeds the specifications on the chassis schematic diagram, take the necessary
corrective action.
Table MAXIMUM ANODE VOLTAGE
beam current at 0 mA at 0.7 mA at 1.4 mA
A/B/R 34.5 kV 32.5 kV 31.0 kV
9. When you degauss the set with an external degaussing c oil, you m ust keep strictl y item “ * Notes about degaussing method ” of ADJUSTMENT PROCEDURES.
FE750
SCHEMATIC DIAGRAMS

CONTENTS

Page No.
MAIN PWB (1/4) SCHEMATIC DIAGRAM .................................................................. 1
MAIN PWB (2/4) PWB SCHEMATIC DIAGRAM ......................................................... 2
MAIN PWB (3/4) PWB SCHEMATIC DIAGRAM ......................................................... 3
MAIN PWB (4/4) SCHEMATIC DIAGRAM ................................................................... 4
SUB PWB SCHEMATIC DIAGRAM ............................................................................. 5
CRT PWB SCHEMATIC DIAGRAM ............................................................................. 6
OSC PWB SCHEMATIC DIAGRAM ............................................................................. 7
CONTROL PWB SCHEMATIC DIAGRAM .................................................................... 8