Key Features .......................................................................................................................................... 3
Front View .............................................................................................................................................. 5
Ultra compact form of 93mm in width, 13 liters in volume
Up to 32 GB of high speed DDR3-1600 memory
Full manageability by integrated EXPRESSSCOPE Engine 3
Function in maximum 40° C / 104° F ambient temperature
Specification
NEC Corporation Revision 1.0 – July 17 2013 3
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Model
T110f-S
Power
Consumption
(Max. Config, Idling)
114 VA / 97 Watt
114 VA / 97 Watt
113 VA / 96 Watt
(Max. Config,
Operating)
206 VA / 192 Watt
156 VA / 144 Watt
183 VA / 170 Watt
Acoustic Noise
(Sound Pressure
Level) 3
Minimum Config.
32.2 dB
29.1 dB
Maximum Config.
38.2 dB
38.1 dB
Dimensions (W x D x H )
98.0 x 386.5 x 341.0 mm / 3.9 x 15.2 x 13.4 in
Weight (Minimum / Maximum)
8 kg / 11 kg, 17.64 lbs. / 24.25 lbs.
Temperature, Relative Humidity
(non-condensing)
Operating: 10° to 40° C / 50° to 104° F, 20 to 80%
Non-Operating: -10° to 55° C / 14° to 131° F, 20 to 80%
Regulatory and Safety
FCC, CE, UL, CB, RoHS, BSMI, CCC, RCM, WEEE
Operating Systems and Virtualization
Software
Microsoft® Windows Server® 2008 x86 Standard
Microsoft® Windows Server® 2008 x86 Enterprise
Microsoft® Windows Server® 2008 R2 Standard
Microsoft® Windows Server® 2008 R2 Enterprise
Microsoft® Windows Server® 2012 Standard
Microsoft® Windows Server® 2012 Datacenter
Red Hat Enterprise Linux 5.9 or later
4
Red Hat Enterprise Linux 5.9 or later (EM64T)
4
Red Hat Enterprise Linux 6.4 or later
4
Red Hat Enterprise Linux 6.4 or later (EM64T)
4
VMware ESXi™ 5.1 Update 1
1
Embedded SATA RAID controller is supported only on Windows operating systems.
2
Maximum resolution available via EXPRESSSCOPE Engine 3 remote console is 1280 x 1024 / 65K colors.
3
Noise emission was measured in accordance with ISO 7779. The actual value may vary by the operating
environment.
4
For Linux support, contact your sales representative or go to the NEC website at:
Microsoft Windows Server 2012 Standard
Microsoft Windows Server 2012 Datacenter
4 TB
32 GB
Red Hat Enterprise Linux 5
Red Hat Enterprise Linux 6
16 GB
16 GB
Red Hat Enterprise Linux 5 (EM64T)
1 TB
32 GB
Red Hat Enterprise Linux 6 (x86_64)
3 TB
32 GB
VMware ESXi 5.1 1
2 TB
32 GB
Maximum Available Memory
See the table below for the maximum memory size that you can actually use on your system.
The maximum available memory is less than the maximum physical memory supported by your system
because some chipsets require PCI resource space of about 750MB. PCI resource requirements vary
depending on the type and the number of PCI cards you are using.
1
Up to 1 TB of the main memory is available to each virtual machine.
NEC Corporation Revision 1.0 – July 17 2013 11
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Non-RAID
RAID 5
0 MB Cache
1GB Cache
/ Battery
512 MB Cache
Refer to 4.2.1
Refer to 4.2.3
Refer to4.2.5
Refer to 4.2.6
RAID 0/1
SATA
SAS, SATA
SAS, SATA
SAS, SATA
Available Interface
Embedded SATA
RAID Controller
Optional RAID
Controller
Refer to 4.2.2
SATA
512 MB Cache
Refer to4.2.4
SAS, SATA
1GB Cache
/ CacheVault
Refer to 4.2.7
SAS, SATA
RAID 5/6
1GB Cache
/ Battery
512 MB Cache
Refer to4.2.10
Refer to 4.2.11
512 MB Cache
Refer to4.2.9
RAID 0/1
Refer to 4.2.8
SAS, SATA
SAS, SATA
SAS, SATA
Available Interface
SAS, SATA
0MB Cache
1GB Cache
/ CacheVault
Refer to 4.2.12
SAS, SATA
4 Internal Hard Disk Drives
4.1 RAID Configuration
Refer to the section in accordance with your disk form factor and RAID configuration
4.1.1 2.5-inch Drive
Up to four Drives
Up to six Drives
NOTE:
No tape drive can be installed when installing an optional 2.5-inch drive cage.
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
Up to two kinds of drives can be mixed in a system.
All drives within a RAID array should be of the same capacity and rotation speed.
Mixing SAS and SATA hard drives in the same drive cage is not supported.
All drives within a drive cage should be of the same rotation speed.
NEC Corporation Revision 1.0 – July 17 2013 12
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Non-RAID
0 MB Cache
512 MB Cache
Refer to 4.3.1
Refer to 4.3.3
Refer to4.3.4
RAID 0/1
SATA
SATA
SATA
Available Interface
Embedded SATA
RAID Controller
Optional RAID
Controller
Refer to 4.3.2
SATA
RAID 0/1
Refer to 4.3.5
SATA, SAS
Available Interface
4.1.2 3.5-inch Drive
Up to two 3.5-inch Drives
Up to two 3.5-inch Drives plus two 2.5-inch Drives
NOTE:
No tape drive can be installed when installing an optional 2.5-inch drive cage.
Hot plug insertion/removal is not supported on the 3.5-inch drive configuration.
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
All hard drives within a RAID array should be of the same capacity and rotation speed.
All drives within a RAID array should be of the same capacity and rotation speed.
NEC Corporation Revision 1.0 – July 17 2013 13
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA
(Standard)
Cable
Internal SATA Cable
Mini-SAS to mini-SAS
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Drive
4 slots
available
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, RAID0/1/10 capable
(Standard)
Cable
Internal SATA Cable
miniSAS to miniSAS
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Drive
3 slots
available
SATA
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1 x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
4.2 2.5-inch Drive Configuration
4.2.1 Up to four Drives with Embedded SATA Controller
NOTE
Hot plug insertion/removal is not supported with the embedded SATA non-RAID controller.
4.2.2 Up to four Drives with Embedded SATA RAID Controller
NOTE
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
All hard drives within a RAID array should be of the same capacity and rotation speed.
NEC Corporation Revision 1.0 – July 17 2013 14
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (0MB, RAID 0/1)
LSI MegaRAID SAS 9240-8i
RAID0/1/10, 0MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s
N8103-171
Cable
Internal SATA Cable
Mini-SAS to mini-SAS
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Drive
4 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
4.2.3 Up to four Drives with RAID 0/1 Controller with 0 MB Cache
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed..
NEC Corporation Revision 1.0 – July 17 2013 15
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID0/1/10, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
N8103-149
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
N8103-155
Cable
Internal SAS/SATA Cable
Mini-SAS to mini-SAS
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Drive
3 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
4.2.4 Up to four Drives with RAID 0/1 Controller with 512 MB Cache
NEC Corporation Revision 1.0 – July 17 2013 16
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
N8103-150
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
N8103-155
Cable
Internal SAS/SATA Cable
Mini-SAS to mini-SAS
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Drive
4 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
4.2.5 Up to four Drives with RAID 5/6 Controller with 512 MB Cache
NEC Corporation Revision 1.0 – July 17 2013 17
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
N8103-151
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
N8103-155
SSD Caching
Recommended
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-156
Cable
Internal SAS/SATA Cable
Mini-SAS to mini-SAS
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Drive
4 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
4.2.6 Up to four Drives with RAID 5 Controller with 1 GB Cache/Battery
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed..
NEC Corporation Revision 1.0 – July 17 2013 18
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60,
1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache
protection modules included
N8103-167
SSD Caching
Recommended
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-156
Cable
Internal SATA Cable
Mini-SAS to mini-SAS
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Drive
4 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
4.2.7 Up to four Drives with RAID 5 Controller with 1 GB Cache/CacheVault
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation Revision 1.0 – July 17 2013 19
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (0MB, RAID 0/1)
LSI MegaRAID SAS 9240-8i
RAID0/1/10, 128MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
3Gb/s
N8103-171
Cable
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS to 2x Single SATA
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Optional Drive Cage
Required
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8154-56F
Drive
6 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
4.2.8 Up to six Drives with RAID 0/1 Controller with 0 MB Cache
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation Revision 1.0 – July 17 2013 20
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID0/1/10, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
N8103-149
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
N8103-155
Cable
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS to 2x Single SATA
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Optional Drive Cage
Required
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8154-56F
Drive
6 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
4.2.9 Up to six Drives with RAID 0/1 Controller with 512 MB Cache
NOTE:
All hard drives within a RAID array should be of the same capacity and rotation speed.
NEC Corporation Revision 1.0 – July 17 2013 21
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
N8103-150
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
N8103-155
Cable
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS to 2x Single SATA
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Optional Drive Cage
Required
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8154-56F
Drive
6 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
4.2.10 Up to six Drives with RAID 5/6 Controller with 512 MB Cache
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation Revision 1.0 – July 17 2013 22
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID0/1/5/6)
LSI MegaRAID SAS 9267-8i
RAID0/1/5/6/10/50/60, 1 GB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s,
SATA 6Gb/s
N8103-151
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
N8103-155
SSD Caching
Recommended
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-156
Cable
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS to 2x Single SATA
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Optional Drive Cage
Required
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8154-56F
Drive
6 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
4.2.11 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/Battery
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
NEC Corporation Revision 1.0 – July 17 2013 23
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (1GB, RAID 0/1/5/6)
LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60,
1GB Cache, Int. 8ports, PCIe 3.0(x8), 6Gb/s, flash cache
protection modules included
N8103-167
SSD Caching
Recommended
MegaRAID CacheCade
for LSI MegaRAID SAS
NOTE:
- SSD used for cache is required
- The SSD capacity which can be used as read cache is up to
512 GB.
N8103-156
Cable
Internal SATA Cable
mini-SAS to mini-SAS, miniSAS to 2x Single SATA
(Standard)
Drive Cage
Required
2.5-inch Drive Cage
4 x 2.5-inch hot plug drive bays
N8154-59F
Optional Drive Cage
Required
2.5-Inch Hot Plug Drive Cage Kit
2x 2.5-inch hot plug drive bays
Including 1x mini-SAS to 2x Single SATA cable
N8154-56F
Drive
6 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA
(Standard)
Cable
Required
Internal SAS/SATA Cable
miniSAS to 2x Single SATA
K410-278(00)
4.2.12 Up to six Drives with RAID 5/6 Controller with 1 GB Cache/CacheVault
NOTE:
All drives within a RAID array should be of the same type, capacity and rotation speed.
4.3 3.5-inch Drive Configuration
4.3.1 Up to two Drives with Embedded SATA Controller
NEC Corporation Revision 1.0 – July 17 2013 24
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Drive Cage
Required
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
N8154-65F
Drive
2 slots available
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-359
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-360
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-361
Category
Product Name / Description
Part Number
Storage Controller
Embedded SATA Controller
4x 6Gb/s SATA, RAID0/1/10 capable
(Standard)
Cable
Required
Internal SATA Cable
mini-SAS to 2x Single SATA
K410-278(00)
Drive Cage
Required
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
N8154-65F
Drive
2 slots available
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-359
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-360
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-361
3TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 3TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-362
4TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-396
4.3.2 Up to two Drives with Embedded SATA RAID Controller
NOTE:
Embedded SATA RAID controller is supported only on Windows operating systems. An optional RAID
controller is required to configure RAID array for other operating systems.
All hard drives within a RAID array should be of the same capacity.
NEC Corporation Revision 1.0 – July 17 2013 25
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (0MB, RAID 0/1)
LSI MegaRAID SAS 9240-8i
RAID0/1/10, 0MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA 6Gb/s
N8103-171
Cable
Required
Internal SATA Cable
mini-SAS to 2x Single SATA
K410-277(00)
Drive Cage
Required
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
N8154-65F
Drive
2 slots available
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-359
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-360
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-361
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID0/1/10, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
N8103-149
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
N8103-155
Cable
Required
Internal SATA Cable
mini-SAS to 2x Single SATA
K410-277(00)
Drive Cage
Required
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
N8154-65F
Drive
2 slots available
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-359
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-360
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-361
3TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 3TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-362
4TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-396
4.3.3 Up to two Drives with RAID 0/1 Controller with 0 MB Cache
NOTE:
All hard drives within a RAID array should be of the same capacity.
4.3.4 Up to two Drives with RAID 0/1 Controller with 512 MB Cache
NOTE:
All hard drives within a RAID array should be of the same capacity.
NEC Corporation Revision 1.0 – July 17 2013 26
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Storage Controller
Required
RAID Controller (512MB, RAID 0/1)
LSI MegaRAID SAS 9267-8i
RAID0/1/10, 512 MB, Int. 8, PCIe 2.0(x8), SAS 6Gb/s, SATA
6Gb/s
N8103-149
RAID BBU
Recommended
RAID Battery Backup Unit
for LSI MegaRAID SAS 9267-8i
N8103-155
Cable
Required
Internal SATA Cable
mini-SAS to 2x Single SATA, for 3.5-inch drive cage
K410-277(00)
Cable
Required
Internal SAS/SATA Cable
mini-SAS to 2x Single SATA, for 2.5-inch drive cage
K410-287(00)
3.5-inch Drive Cage
Required
3.5-inch Drive Cage
2 x 3.5-inch non hot plug (fixed) drive bays
N8154-65F
2.5-inch Drive Cage
Required
2.5-inch Drive Cage
2 x 2.5-inch non hot plug (fixed) drive bays
N8154-56F
3.5-inch Drive
2 slots available
500GB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 500 GB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-359
1TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 1 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-360
2TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 2 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-361
3TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 3TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-362
4TB 7.2K non-Hot Plug 3.5-inch SATA HDD
1 x 4 TB SATA HDD, 3.5-inch, 6Gb/s, 7,200 rpm
N8150-396
2.5-inch
Drive
2 slots
available
SAS
HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-301
450GB HDD
1x 450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-304
900GB HDD
1x 900 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-332
1.2TB HDD
1x 1.2 TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm
N8150-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm
N8150-331
SATA
HDD
250GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 250 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-356
500GB 7.2K Hot Plug 2.5-inch SATA HDD
1x 500 GB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-357
1TB 7.2K Hot Plug 2.5-inch SATA HDD
1x 1 TB SATA HDD, 2.5-inch, 6Gb/s, 7,200 rpm
N8150-358
SAS
SSD
200GB Hot Plug 2.5-inch SAS SSD
1x 200 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-711
400GB Hot Plug 2.5-inch SAS SSD
1x 400 GB SAS SSD, eMLC, 2.5-inch, 6Gb/s
N8150-712
4.3.5 3.5-inch and 2.5-inch Drives with RAID 0/1 Controller with 512 MB Cache
NOTE:
NEC Corporation Revision 1.0 – July 17 2013 27
All hard drives within a RAID array should be of the same form factor, capacity and rotation speed.
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name / Description
Part Number
Internal
1 slot available
Required
Internal Slim DVD-ROM drive
Slim DVD-ROM drive
N8151-119
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, not including writing software
Up to four teams per one system
Up to four ports per one team
Windows Server 2008
Windows Server 2008 R2
Window Server 2012
Red Hat Linux
5 Internal Optical Drive
NOTE:
Up to 1 optical drive can be connected.
N8151-121 Optical Drive Bay Cover must be installed when not installing any internal optical drives.
6 Internal RDX Drive
7 PCI Card
7.1 Network Interface Controller
NIC Teaming feature – NIC Teaming and bonding features
See the table below for supported network interfaces and OS combinations.
Windows Server 2008 support BASP (Broadcom Advanced Server Program) teaming while Windows
Server 2012 and Linux support teaming with bonding function supported by OS.
NEC Corporation Revision 1.0 – July 17 2013 28
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Network Interface
Operating Systems
GbE
Embedded 1GbE NIC
Windows Server 2008 R2, Windows Serer 2012, RHEL*, VMware
N8104-138
Windows Server 2008 R2, Windows Serer 2012, RHEL*, VMware
N8104-132
Windows Server 2008 R2, Windows Serer 2012, RHEL*, VMware
Product Name / Description
Part Number
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter
6Gb/s SAS, Int. 4 / Ext. 4, 7-pin SATA / SFF-8088, PCIe 2.0 x8
N8103-142
Product Name / Description
Part Number
Serial Port Adapter
Serial port fixed to PCI bracket
N8117-01A
Using iSCSI
See the table below for supported network interfaces and OS combinations.
* RHEL: Red Hat Enterprise Linux
NOTE:
NIC Teaming feature is not supported on iSCSI interfaces.
7.2 SAS Controller
7.3 Serial Port Adapter
NOTE:
Up to one Serial Port Adapter can be installed.
NEC Corporation Revision 1.0 – July 17 2013 29
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Product Name / Description
Part Number
Trusted Platform Module Kit
TPM 1.2 module
N8115-15
Product Name / Description
Part Number
Internal Flash Memory
Internal flash memory to enable software and tools in the EXPRESSBUILDR DVD without
DVD media
NOTE:
- Before use, software and tools must be copied from the EXPRESSBUILDER DVD to the
flash memory.
- The following operations can be performed with the flash memory:
- Installation of Windows server with express setup
- Installation of Starter Pack—the package of NEC qualified drivers and system setting
tools
- Installation of NEC ESMPRO Agent and Universal RAID Utility
- Performance of the Test and Diagnosis Tool
N8115-14
Product Name / Description
Part Number
Flash FDD
USB flash emulating USB floppy disk, Native capacity 1.44 MB
N8160-86
Product Name / Description
Part Number
Keyboard and Mouse Pack (US)
1 x 104-keys White USB keyboard, 1 x USB White Optical Wheel Mouse
(Standard)
8 Other Add-in Components
8.1 Trusted Platform Module Kit
NOTE:
The kit is not available in China.
The kit is not removable after attachment.
"TPM Support" in BIOS setup menu must be activated prior to use of this kit.
To use Windows BitLocker drive encryption, be sure to keep the "recovery password" of BitLocker
function. The recovery password is required to restore data for hardware replacement during a
system error.
8.2 Internal Flash Memory
Available socket: 1
8.3 Flash FDD
Choose the Flash FDD if you need to prepare an alternative device for a floppy drive.
NOTE:
Up to one derive can be connected
8.4 Input Devices
NEC Corporation Revision 1.0 – July 17 2013 30
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Product Name / Description
Part Number
Remote KVM and Media License Kit
License for one server.
Remote KVM and remote media are enabled regardless of OS status.
Remote KVM:
- Displays a graphics console on the web browser of the remote terminal (PC/server).
- Controls keyboard and mouse via the remote terminals' web browser
Remote media:
Enables the user to use the CD / DVD / FD / Flash memory of the remote terminals
(PC/server) as if accessing the local drives.
N8115-04
Product Name / Description
Part Number
Rack Conversion Kit
Convert to 3U form factor
N8143-94
Category
Product Name / Description
Part Number
Front Bezel
Dust Proof Bezel with Sensor
Including 1 set of filter replacement sensors, 1 set of dust proof
filters
N8146-39
Filter
Dust proof filter (5 pcs.)
For N8146-39 Dust Proof filter
Removal capacity of particles : Up to 1 μm-sized
N8147-23
Product Name / Description
Part Number
Tamper Proof Cover
Tamper proof cover to prevent erroneous operation of a power button
N8146-42
9 Add-on Components
9.1 Server Management License
The server integrates the EXPRESSSCOPE Engine 3 as standard. Refer to Server Management for the
standard management features. For more extensive remote KVM and remote media features, choose the
following kit.
NOTE:
Remote KVM and remote media features are not available for virtual machines.
9.2 Rack Conversion Kit
9.3 Dust Proof Kit
The server supports the dust resistant feature. Choose the following kit to install the system in dusty
places.
9.4 Tamper Proof Power Button Covers
NEC Corporation Revision 1.0 – July 17 2013 31
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Category
Product Name
Drive supported
Part Number
RDX
RDX Cartridge (320GB)
N8151-105
N8153-01
RDX Cartridge (500GB)
N8151-105
N8153-02
RDX Cartridge (1TB)
N8151-105
N8153-03
RDX Cartridge (1.5TB)
N8151-105
N8153-04
9.5 Medium and Cartridge
NEC Corporation Revision 1.0 – July 17 2013 32
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Standard
With Remote KVM
and Media License
kit
Hardware
monitoring
Temperature/hard drive1/fan/voltage/power
consumption/ System LAN/degeneration/
(memory/hard drive1)
Hardware configuration information collection
Hardware event log collection
Boot monitoring
BIOS/POST stall, Booting, OS stall, shutdown
3
3
Alerting
HW error, Boot error and OS panic
(by SNMP, E-Mail)
Remote KVM
(via LAN)
POST/BIOS setup, ROM utility
2
Panic screen, Boot screen
2,4,5
CUI-based screen (OS console)
2,5
GUI-based screen (OS console)
- Remote screen recording
-
Remote control
(via LAN)
Remote reset/power on-off/ dump
Remote power cSapping
BIOS/BMC FW update
Remote BIOS setup(partial configuration only)
OS shutdown
3
3
Remote media (CD/DVD/FD/USB)
-
CLP (Command Line Protocol) (DMTF compliant)
Remote control via Web browser (multi user login
at the same time)
Scheduling (without UPS, require NEC ESMPRO
Manager)
The EXPRESSSCOPE Engine 3, integrated into the server, provides superior remote control and system
management features listed in the table below.
1
The feature is not supported on non-hot plug 3.5-inch drive.
2
The standard serial port is not available for the feature.
3
The feature is not supported on VMware systems.
4
Monitoring boot screens is not supported on VMware systems.
5
In VMware systems, only the direct console user interface is supported.
NEC Corporation Revision 1.0 – July 17 2013 33
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Part Number
Product Name
WS 2012
WS 2008R2
WS 2008
WS 2008 x64
RHEL 6
RHEL 6 x64
RHEL 5
RHEL 5 x64
VMware ESXi 5.1
-
Embedded SATA non-RAID Controller
-
-
Embedded SATA RAID Controller
-
- - - - -
-
-
Embedded 1GbE NIC
-
N8103-142
SAS Controller
-
N8103-171
RAID Controller (0MB,RAID 0/1)
-
-
N8103-149
RAID Controller (512MB, RAID 0/1)
-
N8103-150
RAID Controller (512MB, RAID 0/1/5/6)
-
N8103-151
RAID Controller (1GB, RAID 0/1/5/6)
-
N8103-167
RAID Controller (1GB, RAID 0/1/5/6)
-
N8104-138
1000BASE-T Adapter (1ch)
-
N8104-132
1000BASE-T Adapter (2ch)
-
Slots
Part Number
Product Name
#1
#2
#3
#4
N8103-142
SAS Controller
-
N8103-171
RAID Controller (0MB,RAID 0/1)
- - - N8103-149
RAID Controller (512MB,RAID 0/1)
- - -
N8103-150
RAID Controller (512MB,RAID 0/1/5/6)
- - - N8103-151
RAID Controller (1GB,RAID 0/1/5/6)
- - - N8103-167
RAID Controller (1GB, RAID 0/1/5/6)
- - -
N8104-138
1000BASE-T Adapter (1ch)
N8104-132
1000BASE-T Adapter (2ch)
N8117-01A
Serial Port Adapter
OS Support Matrix for PCI Cards and Embedded Controllers
Supported PCI cards and Installable Slots
NEC Corporation Revision 1.0 – July 17 2013 34
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice.
Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in
the United States and/or other countries
Intel , Xeon and Pentium are registered trademarks or trademarks of Intel Corporation or its subsidiaries in
the United States and other countries.
Linux is a trademark of Linus Torvalds.
Red Hat is a registered trademark of Red Hat, Inc. in the U.S.
All other products, brands, or trade names used in this document are trademarks or registered trademarks
of their respective holders.
NEC shall not be liable for technical or editorial errors or omissions contained herein.
For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
The USB interface is not guaranteed to work properly for all USB devices.
NEC Corporation Revision 1.0 – July 17 2013 35
CONFIGRATION GUIDE – NEC Express5800/T110f-S / Liquid cooling model
Revision
Date
Description
1.0
July 17, 2013
Initial release
Revision History
NEC Corporation Revision 1.0 – July 17 2013 36
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.