NEC Express5800 A2010b,Express5800 A1040b,Express5800 A2020b, Express5800/A2040b, Express5800/A2020b, Express5800/A2010b, Express5800/A1040b Configuration Manual

Page 1
Express5800/ A2040b/A2020b/A2010b/A1040b
Configuration Guide
Introduction
This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration of your NEC Express5800 server.
The available models depend on sales regions. For details, please contact your region’s sales representative.
December 2014 Rev. 7.0
NEC Corporation
Page 2
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
2
Contents
TECHNICAL SPECIFICATION ........................................................................................ 4
NEC Express5800/A2040b (including COPT supported model) ...................................................... 4
NEC Express5800/A2020b ................................................................................................................... 5
NEC Express5800/A2010b ................................................................................................................... 6
NEC Express5800/A1040b ................................................................................................................... 7
EXTERNAL VIEWS ......................................................................................................... 8
Front and Rear Views ........................................................................................................................... 8
Dimensions (mm) ............................................................................................................................... 10
A2040b/A2020b/A2010b ............................................................................................................... 10
A1040b .......................................................................................................................................... 10
CONFIGURATION DIAGRAM ....................................................................................... 11
A2040b ..................................................................................................................................................11
A2020b ..................................................................................................................................................11
A2010b ................................................................................................................................................. 12
A1040b ................................................................................................................................................. 12
EXPANSION SLOT ........................................................................................................ 13
SERVER CONFIGURATION ......................................................................................... 14
1 Base Models ................................................................................................................................ 14
1.1 A2040b .............................................................................................................................. 14
1.2 A2020b .............................................................................................................................. 15
1.3 A2010b .............................................................................................................................. 16
1.4 A1040b .............................................................................................................................. 17
1.5 COPT ................................................................................................................................ 18
2 CPU ............................................................................................................................................... 19
A2040b (min. 2CPU / max. 4CPU)/ A1040b (min. 1CPU / max. 4CPU) ....................................... 19
3 Memory ......................................................................................................................................... 21
3.1 Memory Riser Card ........................................................................................................... 21
3.2 Memory Configuration ....................................................................................................... 22
Memory Clock ............................................................................................................................... 28
Maximum Memory Capacity .......................................................................................................... 29
4 Internal Disk Drives ..................................................................................................................... 30
4.1 RAID Configuration ........................................................................................................... 30
4.2 Internal Drive Configuration .............................................................................................. 32
200GB SSD (*CTO*) ............................................................................................................................ 32
400GB SSD (*CTO*) ............................................................................................................................ 32
5 Optical Drive ................................................................................................................................ 36
6 PCI Card ....................................................................................................................................... 37
6.1 Network Interface Controller ............................................................................................. 37
6.2 Using iSCSI ....................................................................................................................... 39
6.3 External Storage Controller ............................................................................................... 40
6.4 PCIe SSD .......................................................................................................................... 42
7 Other Add-in Components ......................................................................................................... 43
7.1 Power Supply Unit ............................................................................................................. 43
7.2 Redundant Fan Kit ............................................................................................................ 44
7.3 Trusted Platform Module Kit .............................................................................................. 44
7.4 Internal Flash Memory....................................................................................................... 45
8 Add-on Components ................................................................................................................... 46
8.1 17-inch LCD Console Unit ................................................................................................. 46
Page 3
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
3
8.2 KVM Switch ....................................................................................................................... 47
8.3 Front Bezel ........................................................................................................................ 48
8.4 Cable Arm .......................................................................................................................... 49
8.5 Management Console Specifications ................................................................................ 50
REFERENCES .............................................................................................................. 51
CPU .................................................................................................................................................. 51
Memory ............................................................................................................................................ 51
Internal Drive ................................................................................................................................... 57
Server Management ........................................................................................................................ 60
PCI Slot: Available Slots and Installation Limitations ................................................................. 61
PCI Card: Priority/Order of Installation......................................................................................... 63
RAS Feature Matrix (per OS) ......................................................................................................... 67
Copyright Notice and Liability Disclaimer ....................................................................................... 70
REVISION HISTORY ..................................................................................................... 71
Page 4
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
4
Technical Specification
NEC Express5800/A2040b (including COPT supported model)
Key Features
4U/up to 4way high performance with the latest Intel® Xeon® processor E7-8800v2, E7-4800v2 product family Up to 4TB of memory capacity, supporting high speed and energy efficient DDR3L01600 memory Redundant resources; service processors, clock and core I/O components Capacity Optimization (COPT) supported model separately available in line-up for CPU resource optimization Up to 8 2.5-inch HDD/SSD High energy efficiency with 80 PLUS(RI Platinum certified power supply unit
Express5800/A2040b
Product Code
CPU
NE3301-H001F NE3301-H002F NE3301-H003F NE3301-H004F NE3301-H005F NE3301-H006F NE3301-H007F NE3301-H008F
Intel® Xeon®
Processor
E7-4890 v2
Intel® Xeon®
Processor
E7-4870v2 *1
Intel® Xeon®
Processor E7-4860v2
Intel® Xeon®
Processor E7-4830v2
Intel® Xeon®
Processor E7-4820v2
Intel® Xeon®
Processor
E7-4809v2 *1
Intel® Xeon®
Processor
E7-8891v2 *1
Intel® Xeon®
Processor E7-8893v2
2.80GHz 2.30GHz 2.60GHz 2.20GHz 2.00GHz 1.90GHz 3.20GHz 3.40GHz
2/4
37.5MB 30MB 20MB 16MB 12MB 37.5MB
15C / 30T 15C/30T 12C/24T 10C / 20T 8C / 16T 6C / 12T 10C / 20T 6C / 12T
Intel® C602-J chipset
Not pre-installed
Registered DIMM : 1TB (64x 16GB), Load Reduced DIMM : 4TB (64x 64GB)
1333MHz
ECC, x4 SDDC (Independence mode), DDDC (LockStep mode)
Supported
Supported
HDD: 2.5-inch SAS 9.6TB (8x 1.2TB), SSD: 2.5-inch SAS 3.2TB (8x 400GB)
Supported
SAS 6Gb/s : RAID 0/1/5/6/10/50/60
Internal drive (option) *2
-
-
Expansion Slots
14x PCI Express 3.0 (x8 lane, x8 socket) (Low profile, 167.6mm in length)
2x PCI Express 3.0 (x4 lane, x8 socket) (Low profile, 167.6mm in length)
Embedded in management controller chip / 8MB
16,770,000 colors: 640x480, 800x600, 1,024x768, 1,152x864, 1,280x1,024, 1,600x1,200
5x USB2.0 (3x front, 1x rear, 1x internal), 1x Analog RGB (Mini D-Sub 15-pin, 1x front),
1x SUV 2x USB2.0, 1x serial (RS-232C/D-Sub 9-pin), 1x VGA (Mini D-Sub 15-pin))
2x Management LAN connector (1000BASE-T/100BASE-TX/10BASE-T, RJ-45, 2x rear)
Supported (hot-plug available)
Supported (standard, hot-plug available)
443.0mm x 719.3mm x 174.5mm (w/o protuberance/inner rail)
482.6mm x 892.5mm x 175.5mm (including protuberance/inner rail)
36kg / 55kg (including rail)
Not Pre-installed
800W or 1000W 80 PLUS® Platinum certified, hot plug (max. 4 units)
AC100V/200V±10%, 50/60Hz±3Hz
1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 2296VA/2250W 2194VA/2150W 2194VA/2150W 2092VA/2050W 2092VA/2050W 2092VA/2050W 2296VA/2250W 2296VA/2250W 2347VA/2300W 2245VA/2200W 2245VA/2200W 2143VA/2100W 2143VA/2100W 2143VA/2100W 2347VA/2300W 2347VA/2300W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 2284VA/2238W 2182VA/2138W 2182VA/2138W 2080VA/2038W 2080VA/2038W 2080VA/2038W 2284VA/2238W 2284VA/2238W 2335VA/2288W 2233VA/2188W 2233VA/2188W 2131VA/2088W 2131VA/2088W 2131VA/2088W 2335VA/2288W 2335VA/2288W
8280KJ/ 7920KJ/ 7920KJ/ 7560KJ/h 7560KJ/h 7560KJ/h 8280KJ/ 8280KJ/
Operating: 10 to 40 / 50 to 104, 20 to 80%
Non-Operating: -10 to 55 / 14 to 131, 20 to 80% (no condensation either when operating or when stored)
EXPRESSBUILDER (NEC ESMPRO Manager (Windows/Linux), NEC ESMPRO Agent, User's Guide (electronic document) included),
Getting Started, SUV Cable, Rack Mount Kit
-
Microsoft® Windows Server® 2008 R2 Standard (SP1or later) / Enterprise (SP1 or later) / Datacenter (SP1 or later)
Microsoft® Windows Server® 2012 Standard / Datacenter,
Microsoft® Windows Server® 2012 R2 Standard *4
Red Hat® Enterprise Linux® Linux 6.4 or later (x86_64)
VMware® ESXi™ 5.1 Update 2,
VMware® ESXi™ 5.5
Remarks
Standby (shown in the Power Consumption) means the status before log-in at OS booted.
Note;
*1 CTO categorized item; lead time for delivery is different from other item *2 Either internal DVD-ROM or DVD SuperMULTI should be installed for maintenance and/or OS re-installation purpose. *3 Minimum configuration: 2x CPU, 2x DIMM, 0x HDD, 1x PCIe Card, 2x 800W Power Supply Unit *4 Need to use "Support Kit" provided through web site in order to install at users site.
Model Name
CPU
Processor Clock Speed
Number of CPUs, min./max.
Base Unit
NE3400-040F
Base Unit (COPT)
NE3400-041F
Rank Sparing
Memory Mirroring
Chipset
3rd Cache
Number of Cores (C) / Thread (T) per CPU
DDR3L-1600 Registered DIMM (8/16GB), DDR3L-1600 Load Reduced DIMM (32GB), DDR3L-1333 Load Reduced DIMM (64GB)
1600MHz
1600MHz
Graphic Display / Resolution
Memory
Capacity, standard/maximum Memory Module
Maximum Clock Speed
Error Check, Correction
(100V max. configuration , 25 Standby)
(100V max. configuration , 25 High Load)
(100V max. configuration , Maximum)
Auxiliary Storage Device
Hard Disk Drive
Internal (standard)
Internal (maximum)
Hot Plug
Interface / RAID Level
Optical Disk Drive
FDD
Expansion Bay
Standard Interface
Supported Slots Graphics Chip/Video RAM
Redundant Power Supply
Redundant Fan
External Dimensions (width x depth x height) Power Consumption
Weight (min.*3 / max.)
Power Supply Unit
Environmental Requirements Temperature/Humidity
(200V max. configuration , 25 High Load)
(200V max. configuration , Maximum)
Calorific Value (KJ/h)
(200V max. configuration , 25 Standby)
Supported OS
Accessories Installed OS
Page 5
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
5
NEC Express5800/A2020b
Key Features
4U/2way server with high performance with the latest Intel® Xeon® processor E7-8800v2, E7-4800v2 product family Up to 4TB of memory capacity, supporting high speed and energy efficient DDR3L01600 memory Superior I/O scalability: up to 16 PCI Express 3.0 slots Redundant resources; service processors, clock and core I/O components Up to 8 2.5-inch HDD/SSD High energy efficiency with 80 PLUS(RI Platinum certified power supply unit
Express5800/A2020b
Product Code CPU
NE3400-021F NE3400-022F NE3400-023F NE3400-024F NE3400-025F NE3400-026F NE3400-027F NE3400-028F
Intel® Xeon®
Processor
E7-4890 v2
Intel® Xeon®
Processor
E7-4870v2 *1
Intel® Xeon®
Processor E7-4860v2
Intel® Xeon®
Processor E7-4830v2
Intel® Xeon®
Processor E7-4820v2
Intel® Xeon®
Processor
E7-4809v2 *1
Intel® Xeon®
Processor
E7-8891v2 *1
Intel® Xeon®
Processor E7-8893v2
2.80GHz 2.30GHz 2.60GHz 2.20GHz 2.00GHz 1.90GHz 3.20GHz 3.40GHz
2
37.5MB 30MB 20MB 16MB 12MB 37.5MB
15C / 30T 15C/30T 12C/24T 10C / 20T 8C / 16T 6C / 12T 10C / 20T 6C / 12T
Intel® C602-J chipset
Not pre-installed
Registered DIMM : 1TB (64x 16GB), Load Reduced DIMM : 4TB (64x 64GB)
DDR3L-1600 Registered DIMM (8/16GB), DDR3L-1600 Load Reduced DIMM (32GB), DDR3L-1333 Load Reduced DIMM (64GB)
1333MHz
ECC, x4 SDDC (Independence mode), DDDC (LockStep mode)
Supported
Supported
HDD: 2.5-inch SAS 9.6TB (8x 1.2TB), SSD: 2.5-inch SAS 3.2TB (8x 400GB)
Supported
SAS 6Gb/s : RAID 0/1/5/6/10/50/60
Internal drive (option) *2
-
-
Expansion Slots
14x PCI Express 3.0 (x8 lane, x8 socket) (Low profile, 167.6mm in length)
2x PCI Express 3.0 (x4 lane, x8 socket) (Low profile, 167.6mm in length)
Embedded in management controller chip / 8MB
16,770,000 colors: 640x480, 800x600, 1,024x768, 1,152x864, 1,280x1,024, 1,600x1,200
5x USB2.0 (3x front, 1x rear, 1x internal), 1x Analog RGB (Mini D-Sub 15-pin, 1x front),
1x SUV 2x USB2.0, 1x serial (RS-232C/D-Sub 9-pin), 1x VGA (Mini D-Sub 15-pin))
2x Management LAN connector (1000BASE-T/100BASE-TX/10BASE-T, RJ-45, 2x rear)
Supported (hot-plug available)
Supported (standard, hot-plug available)
443.0mm x 719.3mm x 174.5mm (w/o protuberance/inner rail)
482.6mm x 892.5mm x 175.5mm (including protuberance/inner rail)
36kg / 55kg (including rail)
Not Pre-installed
800W or 1000W 80 PLUS® Platinum certified, hot plug (max. 4 units)
AC100V/200V±10%, 50/60Hz±3Hz
1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 1442VA/1413W 2169VA/2126W 2088VA/2046W 2088VA/2046W 2006VA/1966W 2006VA/1966W 2006VA/1966W 2169VA/2126W 2169VA/2126W 2220VA/2176W 2139VA/2096W 2139VA/2096W 2057VA/2016W 2057VA/2016W 2057VA/2016W 2220VA/2176W 2220VA/2176W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 2157VA/2114W 2076VA/2034W 2076VA/2034W 1994VA/1954W 1994VA/1954W 1994VA/1954W 2157VA/2114W 2157VA/2114W 2208VA/2164W 2127VA/2084W 2127VA/2084W 2045VA/2004W 2045VA/2004W 2045VA/2004W 2208VA/2164W 2208VA/2164W
7834KJ/ 7546KJ/ 7546KJ/ 7258KJ/h 7258KJ/h 7258KJ/h 7834KJ/ 7834KJ/
Operating: 10 to 40 / 50 to 104, 20 to 80%
Non-Operating: -10 to 55 / 14 to 131, 20 to 80% (no condensation either when operating or when stored)
EXPRESSBUILDER (NEC ESMPRO Manager (Windows/Linux), NEC ESMPRO Agent, User's Guide (electronic document) included),
Getting Started, SUV Cable, Rack Mount Kit
-
Microsoft® Windows Server® 2008 R2 Standard (SP1or later) / Enterprise (SP1 or later) / Datacenter (SP1 or later)
Microsoft® Windows Server® 2012 Standard / Datacenter,
Microsoft® Windows Server® 2012 R2 Standard *4
Red Hat® Enterprise Linux® Linux 6.4 or later (x86_64)
VMware® ESXi™ 5.1 Update 2,
VMware® ESXi™ 5.5
Remarks
Standby (shown in the Power Consumption) means the status before log-in at OS booted.
Note;
*1 CTO categorized item; lead time for delivery is different from other item *2 Either internal DVD-ROM or DVD SuperMULTI should be installed for maintenance and/or OS re-installation purpose. *3 Minimum configuration: 2x CPU, 2x DIMM, 0x HDD, 1x PCIe Card, 2x 800W Power Supply Unit *4 Need to use "Support Kit" provided through web site in order to install at users site.
1600MHz
1600MHz
Environmental Requirements Temperature/Humidity
Accessories Installed OS
Supported OS
Calorific Value (KJ/h)
Redundant Fan
External Dimensions (width x depth x height) Weight (min.*3 / max.)
Power Supply Unit Power Consumption
(100V max. configuration , 25 Standby)
(100V max. configuration , 25 High Load)
(100V max. configuration , Maximum)
(200V max. configuration , 25 Standby)
(200V max. configuration , 25 High Load)
(200V max. configuration , Maximum)
Redundant Power Supply
Auxiliary Storage Device
Hard Disk Drive
Internal (standard)
Internal (maximum)
Hot Plug
Interface / RAID Level
Optical Disk Drive
FDD
Expansion Bay
Supported Slots Graphics Chip/Video RAM
Graphic Display / Resolution
Standard Interface Chipset
Memory
Capacity, standard/maximum Memory Module
Maximum Clock Speed
Error Check, Correction
Rank Sparing
Memory Mirroring
Model Name
CPU
Processor Clock Speed
Number of CPUs
3rd Cache
Number of Cores (C) / Thread (T) per CPU
Page 6
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
6
NEC Express5800/A2010b
Key Features
4U/1way server with high performance with the latest Intel® Xeon® processor E7-8800v2, E7-4800v2 product family Up to 2TB of memory capacity, supporting high speed and energy efficient DDR3L01600 memory Superior I/O scalability: up to 9 PCI Express 3.0 slots Redundant resources; service processors, clock and core I/O components Up to 8 2.5-inch HDD/SSD High energy efficiency with 80 PLUS(RI Platinum certified power supply unit
Express5800/A2010b
Product Code CPU
NE3400-031F NE3400-032F NE3400-033F NE3400-034F NE3400-035F NE3400-036F NE3400-037F NE3400-038F
Intel® Xeon®
Processor
E7-4890 v2
Intel® Xeon®
Processor
E7-4870v2 *1
Intel® Xeon®
Processor E7-4860v2
Intel® Xeon®
Processor E7-4830v2
Intel® Xeon®
Processor E7-4820v2
Intel® Xeon®
Processor
E7-4809v2 *1
Intel® Xeon®
Processor
E7-8891v2 *1
Intel® Xeon®
Processor E7-8893v2
2.80GHz 2.30GHz 2.60GHz 2.20GHz 2.00GHz 1.90GHz 3.20GHz 3.40GHz
1
37.5MB 30MB 20MB 16MB 12MB 37.5MB
15C / 30T 15C/30T 12C/24T 10C / 20T 8C / 16T 6C / 12T 10C / 20T 6C / 12T
Intel® C602-J chipset
Not pre-installed
Registered DIMM : 512GB (32x 16GB), Load Reduced DIMM : 2TB (32x 64GB)
DDR3L-1600 Registered DIMM (8/16GB), DDR3L-1600 Load Reduced DIMM (32GB), DDR3L-1333 Load Reduced DIMM (64GB)
1333MHz
ECC, x4 SDDC (Independence mode), DDDC (LockStep mode)
Supported
Supported
HDD: 2.5-inch SAS 9.6TB (8x 1.2TB), SSD: 2.5-inch SAS 3.2TB (8x 400GB)
Supported
SAS 6Gb/s : RAID 0/1/5/6/10/50/60
Internaldrive (option) *2
-
-
Expansion Slots
7x PCI Express 3.0 (x8 lane, x8 socket) (Low profile, 167.6mm in length) 2x PCI Express 3.0 (x4 lane, x8 socket) (Low profile, 167.6mm in length)
Embedded in management controller chip / 8MB
16,770,000 colors: 640x480, 800x600, 1,024x768, 1,152x864, 1,280x1,024, 1,600x1,200
5x USB2.0 (3x front, 1x rear, 1x internal), 1x Analog RGB (Mini D-Sub 15-pin, 1x front),
1x SUV 2x USB2.0, 1x serial (RS-232C/D-Sub 9-pin), 1x VGA (Mini D-Sub 15-pin))
2x Management LAN connector (1000BASE-T/100BASE-TX/10BASE-T, RJ-45, 2x rear)
Supported (hot-plug available)
Supported (standard, hot-plug available)
443.0mm x 719.3mm x 174.5mm (w/o protuberance/inner rail)
482.6mm x 892.5mm x 175.5mm (including protuberance/inner rail)
36kg / 49kg (including rail)
Not Pre-installed
800W or 1000W 80 PLUS® Platinum certified, hot plug (max. 4 units)
AC100V/200V±10%, 50/60Hz±3Hz
1033VA/1012W 1033VA/1012W 1033VA/1012W 1033VA/1012W 1033VA/1012W 1033VA/1012W 1033VA/1012W 1033VA/1012W 1370VA/1343W 1330VA/1303W 1330VA/1303W 1289VA/1263W 1289VA/1263W 1289VA/1263W 1370VA/1343W 1370VA/1343W 1421VA/1393W 1381VA/1353W 1381VA/1353W 1340VA/1313W 1340VA/1313W 1340VA/1313W 1421VA/1393W 1421VA/1393W 1028VA/1007W 1028VA/1007W 1028VA/1007W 1028VA/1007W 1028VA/1007W 1028VA/1007W 1028VA/1007W 1028VA/1007W 1363VA/1336W 1322VA/1296W 1322VA/1296W 1282VA/1256W 1282VA/1256W 1282VA/1256W 1363VA/1336W 1363VA/1336W 1414VA/1386W 1373VA/1346W 1373VA/1346W 1333VA/1306W 1333VA/1306W 1333VA/1306W 1414VA/1386W 1414VA/1386W
5015KJ/ 4871KJ/ 4871KJ/ 4727KJ/ 4727KJ/ 4727KJ/ 5015KJ/ 5015KJ/
Operating: 10 to 40 / 50 to 104, 20 to 80%
Non-Operating: -10 to 55 / 14 to 131, 20 to 80% (no condensation either when operating or when stored)
EXPRESSBUILDER (NEC ESMPRO Manager (Windows/Linux), NEC ESMPRO Agent, User's Guide (electronic document) included),
Getting Started, SUV Cable, Rack Mount Kit
-
Microsoft® Windows Server® 2008 R2 Standard (SP1or later) / Enterprise (SP1 or later) / Datacenter (SP1 or later)
Microsoft® Windows Server® 2012 Standard / Datacenter,
Microsoft® Windows Server® 2012 R2 Standard *4
Red Hat® Enterprise Linux® Linux 6.4 or later (x86_64)
VMware® ESXi™ 5.1 Update 2,
VMware® ESXi™ 5.5
Remarks
Standby (shown in the Power Consumption) means the status before log-in at OS booted.
Note;
*1 CTO categorized item; lead time for delivery is different from other item *2 Either internal DVD-ROM or DVD SuperMULTI should be installed for maintenance and/or OS re-installation purpose. *3 Minimum configuration: 1x CPU, 2x DIMM, 0x HDD, 1x PCIe Card, 2x 800W Power Supply Unit *4 Need to use "Support Kit" provided through web site in order to install at users site.
1600MHz
1600MHz
Environmental Requirements Temperature/Humidity
Accessories Installed OS
Supported OS
Calorific Value (KJ/h)
Redundant Fan
External Dimensions (width x depth x height) Weight (min.*3 / max.)
Power Supply Unit Power Consumption
(100V max. configuration , 25 Standby)
(100V max. configuration , 25 High Load)
(100V max. configuration , Maximum)
(200V max. configuration , 25 Standby)
(200V max. configuration , 25 High Load)
(200V max. configuration , Maximum)
Redundant Power Supply
Auxiliary Storage Device
Hard Disk Drive
Internal (standard)
Internal (maximum)
Hot Plug
Interface / RAID Level
Optical Disk Drive
FDD
Expansion Bay
Supported Slots Graphics Chip/Video RAM
Graphic Display / Resolution
Standard Interface Chipset
Memory
Capacity, standard/maximum Memory Module
Maximum Clock Speed
Error Check, Correction
Rank Sparing
Memory Mirroring
Model Name
CPU
Processor Clock Speed
Number of CPUs
3rd Cache
Number of Cores (C) / Thread (T) per CPU
Page 7
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
7
NEC Express5800/A1040b
Key Features
4U/up to 4way server with high performance with the latest Intel® Xeon® processor E7-8800v2, E7-4800v2 product family Up to 4TB of memory capacity, supporting high speed and energy efficient DDR3L01600 memory Up to 8 2.5-inch HDD/SSD High energy efficiency with 80 PLUS(RI Platinum certified power supply unit
Express5800/A1040b
Product Code
CPU
NE3301-H001F NE3301-H002F NE3301-H003F NE3301-H004F NE3301-H005F NE3301-H006F NE3301-H007F NE3301-H008F
Intel® Xeon®
Processor
E7-4890 v2
Intel® Xeon®
Processor
E7-4870v2 *1
Intel® Xeon®
Processor E7-4860v2
Intel® Xeon®
Processor E7-4830v2
Intel® Xeon®
Processor E7-4820v2
Intel® Xeon®
Processor
E7-4809v2 *1
Intel® Xeon®
Processor
E7-8891v2 *1
Intel® Xeon®
Processor E7-8893v2
2.80GHz 2.30GHz 2.60GHz 2.20GHz 2.00GHz 1.90GHz 3.20GHz 3.40GHz
1/4
37.5MB 30MB 20MB 16MB 12MB 37.5MB
15C / 30T 15C/30T 12C/24T 10C / 20T 8C / 16T 6C / 12T 10C / 20T 6C / 12T
Intel® C602-J chipset
Not pre-installed
Registered DIMM : 1TB (64x 16GB), Load Reduced DIMM : 4TB (64x 64GB)
DDR3L-1600 Registered DIMM (8/16GB), DDR3L-1600 Load Reduced DIMM (32GB), DDR3L-1333 Load Reduced DIMM (64GB)
1333MHz
ECC, x4 SDDC (Independence mode), DDDC (LockStep mode)
Supported
Supported
HDD: 2.5-inch SAS 9.6TB (8x 1.2TB), SSD: 2.5-inch SAS 3.2TB (8x 400GB)
Supported
SAS 6Gb/s : RAID 0/1/5/6/10/50/60
Internal drive (option) *2
-
-
Expansion Slots
14x PCI Express 3.0 (x8 lane, x8 socket) (Low profile, 167.6mm in length)
2x PCI Express 3.0 (x4 lane, x8 socket) (Low profile, 167.6mm in length)
Embedded in management controller chip / 8MB
16,770,000 colors: 640x480, 800x600, 1,024x768, 1,152x864, 1,280x1,024, 1,600x1,200
5x USB2.0 (3x front, 1x rear, 1x internal), 1x Analog RGB (Mini D-Sub 15-pin, 1x front),
1x SUV 2x USB2.0, 1x serial (RS-232C/D-Sub 9-pin), 1x VGA (Mini D-Sub 15-pin))
1x Management LAN connector (1000BASE-T/100BASE-TX/10BASE-T, RJ-45, 1x rear)
Supported (hot-plug available)
Supported (standard, hot-plug available)
443.0mm x 719.3mm x 174.5mm (w/o protuberance/inner rail)
482.6mm x 892.5mm x 175.5mm (including protuberance/inner rail)
35kg / 54kg (including rail)
Not Pre-installed
800W or 1000W 80 PLUS® Platinum certified, hot plug (max. 4 units)
AC100V/200V±10%, 50/60Hz±3Hz
1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 1435VA/1406W 2288VA/2242W 2186VA/2142W 2186VA/2142W 2084VA/2042W 2084VA/2042W 2084VA/2042W 2288VA/2242W 2288VA/2242W 2339VA/2292W 2237VA/2192W 2237VA/2192W 2135VA/2092W 2135VA/2092W 2135VA/2092W 2339VA/2292W 2339VA/2292W 1428VA/1399W 1428VA/1399W 1428VA/1399W 1428VA/1399W 1428VA/1399W 1428VA/1399W 1428VA/1399W 1428VA/1399W 2277VA/2231W 2174VA/2131W 2174VA/2131W 2072VA/2031W 2072VA/2031W 2072VA/2031W 2277VA/2231W 2277VA/2231W 2328VA/2281W 2226VA/2181W 2226VA/2181W 2123VA/2081W 2123VA/2081W 2123VA/2081W 2328VA/2281W 2328VA/2281W
8251KJ/ 7891KJ/ 7891KJ/ 7531KJ/h 7531KJ/h 7531KJ/h 8251KJ/ 8251KJ/
Operating: 10 to 40 / 50 to 104, 20 to 80%
Non-Operating: -10 to 55 / 14 to 131, 20 to 80% (no condensation either when operating or when stored)
EXPRESSBUILDER (NEC ESMPRO Manager (Windows/Linux), NEC ESMPRO Agent, User's Guide (electronic document) included),
Getting Started, SUV Cable, Rack Mount Kit
-
Microsoft® Windows Server® 2008 R2 Standard (SP1or later) / Enterprise (SP1 or later) / Datacenter (SP1 or later)
Microsoft® Windows Server® 2012 Standard / Datacenter,
Microsoft® Windows Server® 2012 R2 Standard *4
Red Hat® Enterprise Linux® Linux 6.4 or later (x86_64)
VMware® ESXi™ 5.1 Update 2,
VMware® ESXi™ 5.5
Remarks
Standby (shown in the Power Consumption) means the status before log-in at OS booted.
Note;
*1 CTO categorized item; lead time for delivery is different from other item *2 Either internal DVD-ROM or DVD SuperMULTI should be installed for maintenance and/or OS re-installation purpose. *3 Minimum configuration: 1x CPU, 2x DIMM, 0x HDD, 1x PCIe Card, 2x 1000W Power Supply Unit *4 Need to use "Support Kit" provided through web site in order to install at users site.
1600MHz
1600MHz
Environmental Requirements Temperature/Humidity
Accessories Installed OS
Supported OS
Calorific Value (KJ/h)
Redundant Fan
External Dimensions (width x depth x height) Weight (min.*3 / max.)
Power Supply Unit Power Consumption
(100V max. configuration , 25 Standby)
(100V max. configuration , 25 High Load)
(100V max. configuration , Maximum)
(200V max. configuration , 25 Standby)
(200V max. configuration , 25 High Load)
(200V max. configuration , Maximum)
Redundant Power Supply
Auxiliary Storage Device
Hard Disk Drive
Internal (standard)
Internal (maximum)
Hot Plug
Interface / RAID Level
Optical Disk Drive
FDD
Expansion Bay
Supported Slots Graphics Chip/Video RAM
Graphic Display / Resolution
Standard Interface Chipset
Memory
Capacity, standard/maximum Memory Module
Maximum Clock Speed
Error Check, Correction
Rank Sparing
Memory Mirroring
Model Name
Base Unit
NE3300-040F
CPU
Processor Clock Speed
Number of CPUs, min./max.
3rd Cache
Number of Cores (C) / Thread (T) per CPU
Page 8
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
8
External Views
Front and Rear Views
Front View
Legend
A.
Location LED
M.
BMC OFF Button
B.
PSU/FAN LED
N.
NMI Button
C.
PCI LED
O.
RESET Button
D.
MEM LED
P.
UID LED
E.
CPU LED
Q.
UID Button
F.
VLT/TMP LED (Voltage/Temperature)
R.
SYSTEM POWER LED
G.
CNFG LED (Configuration)
S.
SYSTEM POWER Button
H.
MISC LED
T.
USB Connectors
I.
NEXT LED
U.
VGA Connector
J.
NEXT Button
V.
Optical Drive Bay
K.
DISK Access LED
W.
2.5-inch Drive Bays
L.
SYSTEM STATUS LED
X.
Slide Tag
A B P
Q
R
E G I D F
J K L M N B C H
O
S T U
V W X
Page 9
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
9
Rear View
Legend
A.
MGB#1 Status LED
I.
MGB#1 Maintenance LAN Connector
B.
UID LED
J.
MGB#1 Management LAN Connector
C.
MGB#2 Status LED *1
K.
MGB#2 Maintenance LAN Connector *1
D.
PCI Slots (Low Profile)
L.
MGB#2 Management LAN Connector *1
E.
UID Button
M.
SUVCable Connector *2
F.
MGB#1 RESET Button
N.
Power Supply Unit
G.
MGB#2 RESET Button *1
O.
AC POWER LED
H.
USB Connector
P.
AC Inlet
*1 Not applicable to A1040b *2 2x USB Connectors and 1x Serial Port and 1 x VGA Connector can be connected through SUB Cable
(attached to Base Models, 2m length)
A
C
D F G H I
J
K
L
M E N
O
B
P
Page 10
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
10
Dimensions (mm)
A2040b/A2020b/A2010b
A1040b
* In case of using slide rail attachment (cable arm in use)
The above illustrations including inner rail.
*
*
Page 11
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
11
Configuration Diagram
A2040b
Legend: Standard components Minimum required components
A2020b
Legend: Standard components Minimum required components
Page 12
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
12
A2010b
Legend: Standard components Minimum required components
A1040b
Legend: Standard components Minimum required components
Page 13
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
13
Expansion Slot
Legend
Slot #1
PCI Express 3.0 (x8 lane, x8 socket)
Slot #2
PCI Express 3.0 (x8 lane, x8 socket)
Slot #3
PCI Express 3.0 (x8 lane, x8 socket)
Slot #4
PCI Express 3.0 (x8 lane, x8 socket)
Slot #5
PCI Express 3.0 (x8 lane, x8 socket)
Slot #6
PCI Express 3.0 (x8 lane, x8 socket)
Slot #7
PCI Express 3.0 (x8 lane, x8 socket)
Slot #8
PCI Express 3.0 (x4 lane, x8 socket)
Slot #9
PCI Express 3.0 (x4 lane, x8 socket)
Slot #10
PCI Express 3.0 (x8 lane, x8 socket)
Slot #11
PCI Express 3.0 (x8 lane, x8 socket)
Slot #12
PCI Express 3.0 (x8 lane, x8 socket)
Slot #13
PCI Express 3.0 (x8 lane, x8 socket)
Slot #14
PCI Express 3.0 (x8 lane, x8 socket)
Slot #15
PCI Express 3.0 (x8 lane, x8 socket)
Slot #16
PCI Express 3.0 (x8 lane, x8 socket)
NOTE:
Foa all PCI slot: Low Profile, 167.6mm in length PCI slot performance: x4 lane for Slot #8 and #9, x8 lane for the others Hot Plug supported: Slot #2 to #9 (8 slots), except for A1040b For A2040b: Slot#1 to #9 are available in case of 2CPU configuration, Slot#1 to #13 are available in case
of 3CPU configuration and Slot#1 to #16 are available in case of 4CPU configuration.
For A2020b: Slot#1 to #16 are available For A2010b: Slot#1 to #9 are available For A1040b: Slot#1 and Slot#3 to #5 are available in case of 1CPU configuration, Slot#1 to #9 are
available in case of 2CPU configuration, Slot#1 to #13 are available in case of 3CPU configuration and Slot#1 to #16 are available in case of 4CPU configuration
Slot #1
Slot #2
Slot #3
Slot #4
Slot #5
Slot #6
Slot #7
Slot #8
Slot #9
Slot #10 Slot #11
Slot #12
Slot #13
Slot #14
Slot #15 Slot #16
Page 14
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
14
Server Configuration
1 Base Models
1.1 A2040b
Product Name/Description
Part Number
NEC Express5800/A2040b
no processor, no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-040F
NEC Express5800/A2040b (COPT)
no processor, no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-041F
NOTE:
The base model must be ordered with processor kits, memory riser cards, memory kit, power supply
units and power cables.
Front Bezel and Cable Arm are not attached; need to be ordered separately if required. Number of the available PCI Slots and Memory Riser Card depends on the number of CPUs
Available PCI Slots and Maximum No. of Memory Riser Card
No. of
CPU
Max. No. of
Memory
Riser
Available PCI Slots
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
#15
#16
2 4 Y ‐ ‐ ‐ ‐ ‐ ‐
3 6 Y ‐ ‐
4 8 Y
Page 15
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
15
1.2 A2020b
Product Name/Description
Part Number
NEC Express5800/A2020b (15C/E7-4890v2)
2x Intel® Xeon® Processor E7-4890v2 (2.80 GHz, 15C/30T, 37.5 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-021F
NEC Express5800/A2020b (15C/E7-4870v2) (*CTO*)
2x Intel® Xeon® Processor E7-4870v2 (2.30 GHz, 15C/30T, 30 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-022F
NEC Express5800/A2020b (12C/E7-4860v2)
2x Intel® Xeon® Processor E7-4860v2 (2.60 GHz, 12C/24T, 30 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-023F
NEC Express5800/A2020b (10C/E7-4830v2)
2x Intel® Xeon® Processor E7-4830v2 (2.20 GHz, 10C/20T, 20 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-024F
NEC Express5800/A2020b (8C/E7-4820v2)
2x Intel® Xeon® Processor E7-4820v2 (2.00 GHz, 8C/16T, 16 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-025F
NEC Express5800/A2020b (6C/E7-4809v2) (*CTO*)
2x Intel® Xeon® Processor E7-4809v2 (1.90 GHz, 6C/12T, 12 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-026F
NEC Express5800/A2020b (10C/E7-8891v2) (*CTO*)
2x Intel® Xeon® Processor E7-8891v2 (3.20 GHz, 10C/20T, 37.5 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-027F
NEC Express5800/A2020b (6C/E7-8893v2)
2x Intel® Xeon® Processor E7-8893v2 (3.40 GHz, 6C/12T, 37.5 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-028F
NOTE:
The base model must be ordered with memory riser cards, memory kit, power supply units and power
cables.
Front Bezel and Cable Arm are not attached; need to be ordered separately if required. 2CPU (fixed) model: cannot add CPU (*CTO*) CTO categorized item; lead time for delivery is different from other item.
Available PCI Slots and Maximum No. of Memory Riser Card
No. of
CPU
Max. No. of
Memory
Riser
Available PCI Slots
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
#15
#16
2 8 Y
Page 16
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
16
1.3 A2010b
Product Name/Description
Part Number
NEC Express5800/A2010b (15C/E7-4890v2)
1x Intel® Xeon® Processor E7-4890v2 (2.80 GHz, 15C/30T, 37.5 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-031F
NEC Express5800/A2010b (15C/E7-4870v2) (*CTO*)
1x Intel® Xeon® Processor E7-4870v2 (2.30 GHz, 15C/30T, 30 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-032F
NEC Express5800/A2010b (12C/E7-4860v2)
1x Intel® Xeon® Processor E7-4860v2 (2.60 GHz, 12C/24T, 30 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-033F
NEC Express5800/A2010b (10C/E7-4830v2)
1x Intel® Xeon® Processor E7-4830v2 (2.20 GHz, 10C/20T, 20 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-034F
NEC Express5800/A2010b (8C/E7-4820v2)
1x Intel® Xeon® Processor E7-4820v2 (2.00 GHz, 8C/16T, 16 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-035F
NEC Express5800/A2010b (6C/E7-4809v2) (*CTO*)
1x Intel® Xeon® Processor E7-4809v2 (1.90 GHz, 6C/12T, 12 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-036F
NEC Express5800/A2010b (10C/E7-8891v2) (*CTO*)
1x Intel® Xeon® Processor E7-8891v2 (3.20 GHz, 10C/20T, 37.5 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-037F
NEC Express5800/A2010b (6C/E7-8893v2)
1x Intel® Xeon® Processor E7-8893v2 (3.40 GHz, 6C/12T, 37.5 MB) no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3400-038F
NOTE:
The base model must be ordered with memory riser cards, memory kit, power supply units and power
cables.
Front Bezel and Cable Arm are not attached; need to be ordered separately if required. 1CPU (fixed) model: cannot add CPU (*CTO*) CTO categorized item; lead time for delivery is different from other item.
Available PCI Slots and Maximum No. of Memory Riser Card
No. of
CPU
Max. No. of
Memory
Riser
Available PCI Slots
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
#15
#16
1 4 Y
Y
‐ ‐ ‐ ‐ ‐ ‐ ‐
Page 17
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
17
1.4 A1040b
Product Name/Description
Part Number
NEC Express5800/A1040b
no processor, no RAM, no HDD, no ODD, no Power Supply Unit, no OS
NE3300-040F
NOTE:
The base model must be ordered with processor kits, memory riser cards, memory kit, power supply
units and power cables.
Front Bezel and Cable Arm are not attached; need to be ordered separately if required. Number of the available PCI Slots and Memory Riser Card depends on the number of CPUs
Available PCI Slots and Maximum No. of Memory Riser Card
No. of
CPU
Max. No. of
Memory
Riser
Available PCI Slots
#1
#2
#3
#4
#5
#6
#7
#8
#9
#10
#11
#12
#13
#14
#15
#16
1 2 Y ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐ ‐
2 4 Y ‐ ‐ ‐ ‐ ‐ ‐
3 6 Y ‐ ‐
4 8 Y
Page 18
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
18
1.5 COPT
Capacity Optimization (COPT) is a function to optimize computing resources by enabling CPU cores as many required per workload without any impact to the number of DIMM and PCI slots which depends on CPU configuration.
When necessary, CPU core can be enabled additionally on-site. COPT is available only with A2040b COPT supported model (NEC Express5800/A2040b (COPT)). In order to enable CPU core, Core Activation Key should be ordered for the required number of cores.
Product Name/Description
Part Number
One Core Activation Key (for Embedded)
Need to order at the same time of the server. As many CPU cores as the ordered
number of the One Core Activation Key (for Embedded) are to be enabled when the ordered server is shipped.
Up to the ordered number of the One Core Activation Key (for Embedded), CPU
cores are available for use.
NE3401-H010F
One Core Activation Key (for Add-on)
The enabled CPU core can be added on-site. As many Code Words as the ordered number of the One Core Activation Key (for
Add-on) are shipped, and additional CPU core can be enabled by applying the Code Word to the server.
NE3401-H011F
NOTE:
Contact to our sales representative for software supporting COPT function. When enabling CPU core (or socket) by Core Activation Key, please purchase required software license
as appropriate
In case of using socket license based software, please enable CPU core at the CPU socket on which the
software is operating. Software license is required for the socket with at least one enabled CPU core.
Depending on the OS, the server may need to be rebooted to enable CPU cores Remarks to use COPT under VMware environment:
- Need to purchase the same number of One Core Activation Key as the number of CPU socket.
- Need to enable the same count of CPU cores among all CPUs (excluding CPUs with all cores disabled)
<Examples of OK or NG configuration in case of 4CPU configuration>
Ex.1: OK
Ex.2: OK
Ex.3: NG
Ex.4: NG
CPU1: 1 core enabled
CPU1: 4 core enabled
CPU1: 2 core enabled
CPU1: 1 core enabled
CPU2: 1 core enabled
CPU2: 0 core enabled
CPU2: 1 core enabled
CPU2: 1 core enabled
CPU3: 1 core enabled
CPU3: 0 core enabled
CPU3: 1 core enabled
CPU3: 1 core enabled
CPU4: 1 core enabled
CPU4: 0 core enabled
CPU4: 0 core enabled
CPU4: 0 core enabled
For the details, please refer to the latest version of “Express5800/A2040b Capacity Optimization (COPT)
User's Guide”
Default setting of Core Optimization Mode is Decentralize, where the enabled CPU cores are
distributed to each socket equally.
Page 19
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
19
2 CPU
A2040b (min. 2CPU / max. 4CPU)/ A1040b (min. 1CPU / max. 4CPU)
Product Name/Description
Part Number
Xeon E7-4890 v2 Processor Kit
1x Intel® Xeon® Processor E7-4890 v2(2.80 GHz, 15C/30T, 37.5MB)
NE3301-H001F
Xeon E7-4870v2 Processor Kit (*CTO*)
1x Intel® Xeon® Processor E7-4870v2 (2.30 GHz, 15C/30T, 30 MB)
NE3301-H002F
Xeon E7-4860v2 Processor Kit
1x Intel® Xeon® Processor E7-4860v2 (2.60 GHz, 12C/24T, 30 MB)
NE3301-H003F
Xeon E7-4830v2 Processor Kit
1x Intel® Xeon® Processor E7-4830v2 (2.20 GHz, 10C/20T, 20 MB)
NE3301-H004F
Xeon E7-4820v2 Processor Kit
1x Intel® Xeon® Processor E7-4820v2 (2.00 GHz, 8C/16T, 16 MB)
NE3301-H005F
Xeon E7-4809v2 Processor Kit (*CTO*)
1x Intel® Xeon® Processor E7-4809v2 (1.90 GHz, 6C/12T, 12 MB)
NE3301-H006F
Xeon E7-8891v2 Processor Kit (*CTO*)
1x Intel® Xeon® Processor E7-8891v2 (3.20 GHz, 10C/20T, 37.5 MB)
NE3301-H007F
Xeon E7-8893v2 Processor Kit
1x Intel® Xeon® Processor E7-8893v2 (3.40 GHz, 6C/12T, 37.5 MB)
NE3301-H008F
NOTE:
(*CTO*) CTO categorized item; lead time for delivery is different from other item. Different SKU of CPU/Processors cannot be mixed in a server.
Page 20
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
20
CPU Functions
Intel® Xeon® Processors for this server supports the following CPU functions
Category
Function Name/Summary
CPU
Xeon
E7-4809v2
Xeon E7-4890v2,E7-4870v2 E7-4860v2,E7-4830v2
E7-4820v2
E7-8891v2,E7-8893v2
64 bit
Intel® 64
64 bit function
Power Saving
Enhanced Intel SpeedStep® Technology (Intel® Demand Bases Switching Technology)
Technology to decrease power consumption by adjusting voltage/clock per CPU workload
Performance
Intel® Turbo Boost Technology
Technology to boost clock frequency
Performance
Intel® Hyper-Threading Technology
Technology to use one core as two threads
Virtualization
Intel® Virtualization Technology
Technology to provide hardware (CPU) support for processor virtualization
Security
Execute Disable
Technology to avoid the execution of malware utilizing
buffer over flow error
The maximum number of logical processors supported by OS
See the table below for the maximum number of logical processors that you can actually use on your system
Maximum Number of Logical Processors Supported by Operating
Systems
Maximum Number of Logical Processors Supported by this Server
Microsoft Windows Server 2008 R2 SP1 Standard Microsoft Windows Server 2008 R2 SP1 Enterprise Microsoft Windows Server 2008 R2 SP1 Datacenter
256 1
120
Microsoft Windows Server 2012 Standard Microsoft Windows Server 2012 Datacenter Microsoft Windows Server 2012 R2 Standard Microsoft Windows Server 2012 R2 Datacenter
640 1
120
Red Hat Enterprise Linux 6 (x86_64)
160
120
Oracle Linux 6 /UEK R2 (x86_64)
160
120
VMware ESXi 5.1
160
120
VMware ESXi 5.5
320
120
1
The maximum number of logical processors when using Hyper-V are below:
Windows Server 2008 R2 SP1: 64 logical processors Windows Server 2012, Windows Server 2012 R2 : 320 logical processors
Page 21
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
21
3 Memory
3.1 Memory Riser Card
Memory Riser Card (MR) is a module for installing up to 8 DIMM Please refer to Memory of Reference section for Memory Riser Card installation priority/order.
For A2040b (including COPT model), A2020bA2010b
Product Name/Description
Part Number
Memory Riser Card 16GB/32GB/64GB Memory Kit
Module with 8x DIMM slots. Hot-plug supoprted
NE3402-H001
Memory Riser Card 16GB/32GB/64GB/128GB Memory Kit
Module with 8x DIMM slots. Hot-plug supoprted
NE3402-H002
NOTE:
A2040b: 1 to 2 MRs can be installed per CPU, thus up to 8 MRs can be installed with 4CPU configuration A2020b: Up to 8 MRs can be installed A2010b: Up to 4 MRs can be installed Not pre-installed in Base Model. At least one MR needs to be ordered. Cover for Hot-plug is attached NE3402-H001 and NE3402-H002 can be mixed in one server.
For A1040b
Product Name/Description
Part Number
Memory Riser Card 16GB/32GB/64GB Memory Kit
Module with 8x DIMM slots. Hot-plug not supported
NE3302-H001
Memory Riser Card 16GB/32GB/64GB/128GB Memory Kit
Module with 8x DIMM slots. Hot-plug not supported
NE3302-H002
NOTE:
1 to 2 MRs can be installed per CPU, thus up to 8 MRs can be installed with 4CPU configuration Not pre-installed in Base Model. At least one MR needs to be ordered. NE3302-H001 and NE3302-H002 can be mixed in one server.
Customized Configuration Service (at the Server Delivery)
Product Name/Description
Part Number
Customized Service: Distribution Mode for COPT
NE3300-SV101
NOTE:
This service can be ordered only for A2040b COPT Model and up to one item (service) can be ordered
per one server.
With this service, the location of MR can be changed from the standard BTO Configuration. When allocating enabled CPU cores to all CPU (distributed), this service is recommended to use so that
MR and Memory can be distributed, too. Please refer to Memory of Reference section for Memory Riser Card installation priority/order.
Page 22
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
22
3.2 Memory Configuration
Refer to the section in accordance with your memory configuration. Memory configuration consists of 2 modes; Independent Mode and Lockstep Mode. Under each Mode, 2 features are available; Memory Rank Sparing and Memory Mirroring. Default setting at the server delivery is Lockstep Mode.
Independent Mode (only): Refer to 3.2.1 Lockstep Mode (only): Refer to 3.2.2 Memory Rank Sparing: Refer to 3.2.3 Memory Mirroring: Refer to 3.2.4
Please refer to “Memory” of “Reference” section for Memory on the Memory Riser Card (DIMM) installation priority/order per Independent Mode, Lockstep Mode, Memory Rank Sparing and Memory Mirroring..
Memory Configuration Feature Comparison
See the table below for feature comparisons of memory configurations supported.
Independent Mode
(only)
Memory Rank Sparing
under Independent
Mode
Memory Mirroring
under Independent Mode
Summary
In case of correctable errors, switching to spare memory rank
Redundant memory
Available Memory
-
1/2(8GB RDIMM),
3/4(16GB RDIMM),
7/8(32GB LRDIMM) or
3/4(64GB LRDIMM)
of physical memory
1/2 of physical memory
Available Memory Channel 1
4 4 4
Maximum Memory
Capacity
2
512GB(8GB RDIMM)
1024GB(16GB RDIMM) 2048GB(32GB LRDIMM) 4096GB(64GB LRDIMM)
256GB(8GB RDIMM)
768GB(16GB RDIMM) 1792GB(32GB LRDIMM) 3072GB(64GB LRDIMM)
256GB(8GB RDIMM)
512GB(16GB RDIMM) 1024GB(32GB LRDIMM) 2048GB(64GB LRDIMM)
Data Correction
ECC, x4 SDDC
Notes
RDIMM and LRDIMM
cannot be mixed
RDIMM and LRDIMM
cannot be mixed
RDIMM and LRDIMM
cannot be mixed
1
4 memory channels per Memory Riser Card.
2
All DIMMs have the same capacity
Page 23
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
23
Lockstep Mode (only)
Memory Rank Sparing
under Lockstep Mode
Memory Mirroring
under Lockstep Mode
Summary
2 DRAM failure detected/corrected by memory parallel operation
In case of correctable errors, switching to spare memory rank
Redundant memory
Available Memory
-
1/2(8GB RDIMM),
3/4(16GB RDIMM),
7/8(32GB LRDIMM) or
3/4(64GB LRDIMM)
of physical memory
1/2 of physical memory
Available Memory Channel 3
4 4 4
Maximum Memory
Capacity 4
512GB(8GB RDIMM)
1024GB(16GB RDIMM) 2048GB(32GB LRDIMM) 4096GB(64GB LRDIMM)
256GB(8GB RDIMM)
768GB(16GB RDIMM) 1792GB(32GB LRDIMM) 3072GB(64GB LRDIMM)
256GB(8GB RDIMM)
512GB(16GB RDIMM) 1024GB(32GB LRDIMM) 2048GB(64GB LRDIMM)
Data Correction
ECC, DDDC
Notes
RDIMM and LRDIMM
cannot be mixed
RDIMM and LRDIMM
cannot be mixed
RDIMM and LRDIMM
cannot be mixed
3
4 memory channels per Memory Riser Card
4
All DIMMs have the same capacity
Customized Configuration Service (at the Server Delivery)
Product Name/Description
Part Number
Customized Service: Distribution Mode for COPT
NE3300-SV101
NOTE:
This service can be ordered only for A2040b COPT Model and up to one item (service) can be ordered
per one server.
With this service, according to the change of the location of MR, memory location can be changed from
the standard BTO Configuration.
When allocating enabled CPU cores to all CPU (distributed), this service is recommended to use so that
MR and Memory can be distributed, too. Please refer to Memory of Reference section for the details.
Page 24
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
24
3.2.1 Independent Mode (only)
No. of Available Slot: Max. 4 sets (8x DIMMs) per Memory Riser Card
Category
Product Name/Description
Part Number
Registered DIMM
(RDIMM)
1600 MHz
16GB MEM (2 x 8GB RDIMM)
2x 8GB Registered DIMM, DDR3L-1600(PC3L-12800), ECC
NE3302-H010F
32GB MEM (2x16GB RDIMM)
2x 16GB Registered DIMM, DDR3L-1600(PC3L-12800) , ECC
NE3302-H011F
Load Reduced DIMM (LRDIMM)
1600 MHz
64GB MEM (2x32GB LRDIMM)
2x 32GB Load Reduced DIMM, DDR3L-1600(PC3L-12800) , ECC
NE3302-H012F
1066 MHz
128GB MEM (2x64GB LRDIMM)
2x 64GB Load Reduced DIMM, DDR3L-1333(PC3L-10600) , ECC
NE3302-H013F
NOTE:
Not-preinstalled. Need to order at least 1 set (2x DIMM) For higher memory performance, same type of memory is recommended to be used by every 2 sets (4x
DIMM) in one Memory Riser Card.
RDIMM and LRDIMM cannot be mixed in a server
Page 25
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
25
3.2.2 Lockstep Mode (only)
No. of Available Slot: Max. 4 sets (8x DIMMs) per Memory Riser Card
Category
Product Name/Description
Part Number
Registered DIMM
(RDIMM)
1600 MHz
16GB MEM (2 x 8GB RDIMM)
2x 8GB Registered DIMM, DDR3L-1600(PC3L-12800), ECC
NE3302-H010F
32GB MEM (2x16GB RDIMM)
2x 16GB Registered DIMM, DDR3L-1600(PC3L-12800) , ECC
NE3302-H011F
Load Reduced DIMM (LRDIMM)
1600 MHz
64GB MEM (2x32GB LRDIMM)
2x 32GB Load Reduced DIMM, DDR3L-1600(PC3L-12800) , ECC
NE3302-H012F
1066 MHz
128GB MEM (2x64GB LRDIMM)
2x 64GB Load Reduced DIMM, DDR3L-1333(PC3L-10600) , ECC
NE3302-H013F
NOTE:
Not-preinstalled. Need to order at least 1 set (2x DIMM) For higher memory performance, same type of memory is recommended to be used by every 2 sets (4x
DIMM) in one Memory Riser Card.
RDIMM and LRDIMM cannot be mixed in a server
Page 26
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
26
3.2.3 Memory Rank Sparing
No. of Available Slot: Max. 2 sets (8x DIMMs) per Memory Riser Card
Product Name/Description
Part Number
32GB MEM for Memory Rank Sparing (4 x 8GB RDIMM)
4x 8GB Registered DIMM, DDR3L-1600(PC3L-12800), ECC
NE3302-H020F
64GB MEM for Memory Rank Sparing (4 x 16GB RDIMM)
4x 16GB Registered DIMM, DDR3L-1600(PC3L-12800), ECC
NE3302-H021F
128GB MEM for Memory Rank Sparing (4 x 32GB LRDIMM)
4x 32GB Load Reduced DIMM, DDR3L-1600(PC3L-12800), ECC
NE3302-H022F
256GB MEM for Memory Rank Sparing (4 x 64GB LRDIMM)
4x 32GB Load Reduced DIMM, DDR3L-1333(PC3L-10600), ECC
NE3302-H023F
NOTE:
Not-preinstalled. Need to order at least 1 set (4x DIMM) RDIMM and LRDIMM cannot be mixed in a server
Logical Memory Capacity at Memory Rnak Sparing (ex. Using the Same Capacity DIMMs)
No. of DIMM
Physical Memory Capacity
8GB RDIMM
16GB RDIMM
32GB LRDIMM
64GB LRDIMM
4
16GB
48GB
112GB
192GB
8
32GB
96GB
224GB
384GB
12
48GB
144GB
336GB
576GB
16
64GB
192GB
448GB
768GB
20
80GB
240GB
560GB
960GB
24
96GB
288GB
672GB
1152GB
28
112GB
336GB
784GB
1344GB
32
128GB
384GB
896GB
1536GB
36
144GB
432GB
1008GB
1728GB
40
160GB
480GB
1120GB
1920GB
44
176GB
528GB
1232GB
2122GB
48
192GB
576GB
1344GB
2304GB
52
208GB
624GB
1456GB
2496GB
56
224GB
672GB
1568GB
2688GB
60
240GB
720GB
1680GB
2880GB
64
256GB
768GB
1792GB
3072GB
Page 27
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
27
3.2.4 Memory Mirroring
No. of Available Slot: Max. 2 sets (8x DIMMs) per Memory Riser Card
Product Name/Description
Part Number
32GB MEM for Memory Mirroring (4 x 8GB RDIMM)
4x 8GB Registered DIMM, DDR3L-1600(PC3L-12800), ECC
NE3302-H030F
64GB MEM for Memory Mirroring (4 x 16GB RDIMM)
4x 16GB Registered DIMM, DDR3L-1600(PC3L-12800), ECC
NE3302-H031F
128GB MEM for Memory Mirroring (4 x 32GB LRDIMM)
4x 32GB Load Reduced DIMM, DDR3L-1600(PC3L-12800), ECC
NE3302-H032F
256GB MEM for Memory Mirroring (4 x 64GB LRDIMM)
4x 32GB Load Reduced DIMM, DDR3L-1333(PC3L-10600), ECC
NE3302-H033F
NOTE:
Not-preinstalled. Need to order at least 1 set (4x DIMM) RDIMM and LRDIMM cannot be mixed in a server
Page 28
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
28
Memory Clock
DDR3 Memory clock depends on CPU, Memory Configuration, System BIOS settings. Please refer below for the maximum clock. Please refer to Memory of Reference section for the details.
CPU
Memory
Configuration/Mode
Memory Type
No. of
DIMMs (per
1CPU)
Clock
1.35V
1.5V
Xeon®
E7-4890v2 E7-4870v2 E7-4860v2 E7-8891v2 E7-8893v2
Independent Mode
RDIMM(8, 16GB)
Up to 16
1333 MHz
1333 MHz
LRDIMM (32GB)
Up to 16
1333 MHz
1333 MHz
LRDIMM (64GB)
Up to 16
-
1066 MHz
Lockstep Mode
RDIMM (8, 16GB)
Up to 16
1333 MHz
1600 MHz
LRDIMM (32GB)
Up to 16
1333 MHz
1600 MHz
LRDIMM (64GB)
Up to 16
-
1066 MHz
Xeon®
E7-4830v2 E7-4820v2
Independent Mode
RDIMM(8, 16GB)
Up to 16
1066 MHz
1066 MHz
LRDIMM (32GB)
Up to 16
1066 MHz
1066 MHz
LRDIMM (64GB)
Up to 16
-
1066 MHz
Lockstep Mode
RDIMM (8, 16GB)
Up to 16
1333 MHz
1600 MHz
LRDIMM (32GB)
Up to 16
1333 MHz
1600 MHz
LRDIMM (64GB)
Up to 16
-
1066 MHz
Xeon®
E7-4809v2
Independent Mode
RDIMM(8, 16GB)
Up to 16
1066 MHz
1066 MHz
LRDIMM (32GB)
Up to 16
1066 MHz
1066 MHz
LRDIMM (64GB)
Up to 16
-
1066 MHz
Lockstep Mode
RDIMM (8, 16GB)
Up to 16
1333 MHz
1333 MHz
LRDIMM (32GB)
Up to 16
1333 MHz
1333 MHz
LRDIMM (64GB)
Up to 16
-
1066 MHz
NOTE:
Default Memory voltage setting (at the server delivery) is 1.35V (power saving). Memory voltage can be
changed by System BIOS Set-up menu.
At Lockstep mode, strongly recommends to change memory voltage to 1.5V by BIOS set-up menu. Memory voltage is automatically 1.5V under the following configuration (cannot set 1.35V)
64GB LRDIMM installed
Page 29
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
29
Maximum Memory Capacity
Due to x86 architecture and the specifications of supported OS, the available memory capacity changes, as the following list shows:
Maximum Memory Capacity supported by each OS
Max. Memory Capacity
for this Server
Microsoft Windows Server 2008 R2 SP1 Standard 1
32 GB
32 GB
Microsoft Windows Server 2008 R2 SP1 Enterprise
1
Microsoft Windows Server 2008 R2 SP1 Datacenter 1
2 TB
2 TB
Microsoft Windows Server 2012 Standard 1 Microsoft Windows Server 2012 Datacenter
1
Microsoft Windows Server 2012 R2 Standard 1 Microsoft Windows Server 2012 R2 Datacenter 1
4 TB
4 TB
Red Hat Enterprise Linux 6 (x86_64)
3 TB
2 TB
Oracle Linux6/UEK R2 (x86_64)
4 TB
2 TB
VMware ESXi 5.1 2
2 TB
2 TB
VMware ESXi 5.5 2
4 TB
2 TB
1
The Maximum Memory Capacity when using Hyper-V:
Windows Server 2008 R2 SP1 Standard: 32GB Windows Server 2008 R2 SP1 Enterprise/Datacenter: 1TB Windows Server 2012, Windows Server 2012 R2: 4TB
2
The Maximum Memory Capacity for virtual machine: 1TB
Page 30
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
30
4 Internal Disk Drives
4.1 RAID Configuration
RAID0/1/5/6/10/50/60 is supported. 2 kinds of RAID Controller are supported; with 1GB or 512MB cache. With 1 RAID Controller configuration, max. 8 internal drives can be connected per one RAID Controller. With 2 RAID Controller configuration, max. 4 internal drives can be connected per one RAID Controller.
Controller
RAID
No. of Disk
Capacity
Hot Spare
NE3303-168 or NE3303-173
RAID 0 (striping)
1 ~ 8
Drive Capacity x No. of Drive
N
RAID 1 (mirroring)
2
Drive Capacity x No. of Drive / 2
Y
RAID 5 (parity)
3 ~ 8
Drive Capacity x (No. of Drive-1)
Y
RAID 6 (double parity)
3 ~ 8
Drive Capacity x (No. of Drive-2)
Y
RAID 10 (RAID1 + RAID0)
4/6/8
Drive Capacity x No. of Drive / 2
Y
RAID 50 (RAID5 + RAID0)
6 / 8
Drive Capacity x (No. of Drive-2)
Y
RAID 60 (RAID6 + RAID0)
6 / 8
Drive Capacity x (No. of Drive-4)
Y
NOTE:
Needs to order RAID Controller to configure internal drives For RAID Configuration, same type of internal drives need to be ordered within one RAID group (pack) Multiple RAID group can be configured by one RAID Controller. In case of RAID1, 4 groups at maximum. Different capacity/rotation speed/disk type of internal drives can be mixed in different RAID groups. When configuring hot-spare disks, need to use same type of internal disk for the RAID group.
All internal drives are same type, Global Hot Spare can be available. When mixing different capacity/rotation speed/disk type drives, need to use Dedicated Hot Spare
per RAID group.
With 2 RAID Controller configuration, max. 4 internal drives can be connected per one RAID controller.
Therefore, RAID50/60 is not available, with 2 RAID Controller configuration,
With 2 RAID Controller configurations, RAID cannot be configured among internal drives under different
RAID Controllers.
Please refer to Internal Drive of “Reference section for the details about Internal Drive: Priority/Order of
Installatioin.
Page 31
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
31
1x RAID Controller Configuration
2x RAID Controller Configuration
4.2.1
SAS HDD/SSD
1GB Cache/Flash
512MB Cache/Battery
4.2.2
4.2.4
SAS HDD/SSD
1GB Cache/Flash
SAS HDD/SSD
512MB Cache/Battery
4.2.5
5 年目
SAS HDD/SSD
Page 32
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
32
4.2 Internal Drive Configuration
For RAID Configuration, same type of internal drives need to be ordered within one RAID group (pack) With 1 RAID Controller configuration, different HDDs, SDDs or HDD and SSD cannot be configured in
the BTO. When mixing these drives, please refer to the section Internal Disk at References.
RAID 0/1/5/6/10 can be configured at BTO Configuration. For RAID 50/60, need to configure after the
delivery.
With 2 RAID Controller configuration, the 2
nd
RAID Controller and 5th and more HDDs under the 2nd RAID
Controller cannot be configured at BTO Configuration.
With 2 RAID Controller configuration, RAID cannot be configured between internal drives under different
RAID Controllers.
The delivery lead time of SSD is longer than the others. Please contact to our sales representative for the
delivery.
4.2.1 1x RAID Controller (1GB Cache/Flash) Configuration
Category
Product Name/Description
Part Number
Controller
(Need to order 1)
RAID Controller (1GB, RAID 0/1/5/6/10/50/60)
LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Internal 8 port (4x2 connector), PCIe 3.0(x8), SAS 6Gb/s, Flash Back-up Unit included
NE3303-168
Cable
SAS Cable
1 x mini-SAS to 1 x mini-SAS, x2
(included)
HDD Cage
2.5-inch HDD Cage
8x 2.5-inch, Drive Bay, Hot-Plug supported
(included)
Internal Drives
(Max. 8)
SAS HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-301
450GB HDD
1x450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-304
900GB HDD
1x 900 GB SAS HDD, 2. 5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-332
1.2TB HDD
1x1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 512B sector
NE3350-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 512B sector
NE3350-331
SAS SSD
(eMLC)
200GB SSD (*CTO*)
1x 200 GB SAS SSD, eMLC, 2.5 , 6Gb/s 512B sector
NE3350-711F
400GB SSD (*CTO*)
1x 400 GB SAS SSD, eMLC, 2.5 , 6Gb/s 512B sector
NE3350-712F
NOTE:
Need to order at least 1 internal drive. (*CTO*) CTO categorized item; lead time for delivery is different from other item.
Page 33
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
33
4.2.2 1x RAID Controller (512MB Cache) Configuration
Category
Product Name/Description
Part Number
Controller
(Need to order 1)
RAID Controller (512MB, RAID 0/1/5/6/10/50/60)
LSI MegaRAID SAS 9272-8i RAID0/1/5/6/10/50/60, 512MB Cache, Internal 8 port (4x2 connector), PCIe 3.0(x8), SAS 6Gb/s
NE3303-173
Battery
Battery Back-up Unit (for NE3303-173)
Battery for LSI MegaRAID SAS /9272-8i, 600mm Battery Cable attached
NE3303-153
Cable
SAS Cable
1 x mini-SAS to 1 x mini-SAS, x2
(included)
HDD Cage
2.5-inich HDD Cage
8x 2.5-inch, Drive Bay, Hot Plug supported
(included)
Internal Drives
(Max. 8)
SAS HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-301
450GB HDD
1x450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-304
900GB HDD
1x 900 GB SAS HDD, 2. 5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-332
1.2TB HDD
1x1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 512B sector
NE3350-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 512B sector
NE3350-331
SAS SSD (eMLC)
200GB SSD (*CTO*)
1x 200 GB SAS SSD, eMLC, 2.5 , 6Gb/s 512B sector
NE3350-711F
400GB SSD (*CTO*)
1x 400 GB SAS SSD, eMLC, 2.5 , 6Gb/s 512B sector
NE3350-712F
NOTE:
Need to order at least 1 internal drive. (*CTO*) CTO categorized item; lead time for delivery is different from other item.
Page 34
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
34
4.2.3 2x RAID Controller (1GB Cache/Flash) Configuration
Category
Product Name/Description
Part Number
Controller
(Need to order 2)
RAID Controller (1GB, RAID 0/1/5/6/10/50/60)
LSI MegaRAID SAS 9270CV-8i (with CV) RAID0/1/5/6/10/50/60, 1GB Cache, Internal 8 port (4x2 connector), PCIe 3.0(x8), SAS 6Gb/s, Flash Back-up Unit included
NE3303-168
Cable
SAS Cable
1 x mini-SAS to 1 x mini-SAS, x2
(included)
HDD Cage
2.5-inch HDD Cage
8x 2.5-inch, Drive Bay, Hot Plug supported
(included)
Internal Drives
(Max. 8)
SAS HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-301
450GB HDD
1x450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-304
900GB HDD
1x 900 GB SAS HDD, 2. 5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-332
1.2TB HDD
1x1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 512B sector
NE3350-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 512B sector
NE3350-331
SAS SSD
(eMLC)
200GB SSD (*CTO*)
1x 200 GB SAS SSD, eMLC, 2.5 , 6Gb/s 512B sector
NE3350-711F
400GB SSD (*CTO*)
1x 400 GB SAS SSD, eMLC, 2.5 , 6Gb/s 512B sector
NE3350-712F
NOTE:
Need to order at leaset 2 internal drives (*CTO*) CTO categorized item; lead time for delivery is different from other item. RAID50/60 is not available due to the limitation of the number of internal disks. RAID configuration is not available between internal drives under different RAID Controllers. RAID settings at the server delivery are done only to the internal disk drives at Slot #0 to Slot #3. Not configured into the server (not BTO) for the 2
nd
RAID Controller and 5th and beyond internal disk
drives.
Page 35
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
35
4.2.4 2x RAID Controller (512MB Cache) Configuration
Category
Product Name/Description
Part Number
Controller
(Need to order 2)
RAID Controller (512MB, RAID 0/1/5/6/10/50/60)
LSI MegaRAID SAS 9272-8i RAID0/1/5/6/10/50/60, 512MB Cache, Internal 8 port (4x2 connector), PCIe 3.0(x8), SAS 6Gb/s
NE3303-173
Battery
Battery Back-up Unit (for NE3303-173)
Battery for LSI MegaRAID SAS /9272-8i, 600mm Battery Cable attached
NE3303-153
Cable
SAS Cable
1 x mini-SAS to 1 x mini-SAS, x2
(included)
HDD Cage
2.5-inch HDD Cage
8x 2.5-inch, Drive Bay, Hot Plug supported
(included)
Internal Drives
(Max. 8)
SAS HDD
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-301
450GB HDD
1x450 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-322
600GB HDD
1x 600 GB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-304
900GB HDD
1x 900 GB SAS HDD, 2. 5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-332
1.2TB HDD
1x1.2TB SAS HDD, 2.5-inch, 6Gb/s, 10,000 rpm 512B sector
NE3350-408
146.5GB HDD
1x 146.5 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 512B sector
NE3350-303
300GB HDD
1x 300 GB SAS HDD, 2.5-inch, 6Gb/s, 15,000 rpm 512B sector
NE3350-331
SAS SSD (eMLC)
200GB SSD (*CTO*)
1x 200 GB SAS SSD, eMLC, 2.5 , 6Gb/s 512B sector
NE3350-711F
400GB SSD (*CTO*)
1x 400 GB SAS SSD, eMLC, 2.5 , 6Gb/s 512B sector
NE3350-712F
NOTE:
Need to order at least 2 internal drives (*CTO*) CTO categorized item; lead time for delivery is different from other item. RAID50/60 is not available due to the limitation of the number of internal disks. RAID configuration is not available between internal drives under different RAID Controllers. RAID settings at the server delivery are done only to the internal disk drives at Slot #0 to Slot #3. Not configured into the server (not BTO) for the 2
nd
RAID Controller and 5th and beyond internal disk
drives.
Page 36
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
36
5 Optical Drive
Up to 1 Optical Drive internal) can be connected
Category
Product Name/Description
Part Number
Internal
Internal DVD-ROM Drive
Slim DVD-ROM Drive, SATA
NE3351-100
Internal DVD Super Multi Drive
Slim DVD Super Multi drive, including writing software, SATA
NOTE:
- Supported OS: Windows Server® 2008R2 and 2012
- Included writing software supports the following OS (Japanese ver.)
Windows Server 2008 R2 SP1 Standard Windows Server 2008 R2 SP1 Enterprise Windows Server 2008 R2 SP1 Datacenter Windows Server 2012 Standard Windows Server 2012 Datacenter Windows Server 2012 R2 Standard Windows Server 2012 R2 Datacenter
NE3351-107
NOTE:
Not pre-installed. Needs to order either Internal DVD-ROM Drive or Internal DVD Super Multi Drive for
server maintenance and/or OS installation purpose:
Page 37
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
37
6 PCI Card
Please refer to Available Slots of References section regarding PCI Slots; Available Slots and Installation Limitations
PCI Card Customized Configuration Service
Product Name/Description
Part Number
Customized Service: PCI Cards
NE3300-SV401
NOTE:
When requiring different PCI cards configuration from the standard BTO Configuration at the server
delivery, needs to order this customized service.
Please refer to PCI Card: Priority/Order of Installation for installation rules at BTO configuration.
6.1 Network Interface Controller
Category
Product Name/Description
Part Number
GbE
1000BASE-T Adapter (1 port))
Broadcom BCM5718 PCIe 2.0(x4) (Performance: PCIe 2.0(x1)) Low Profile
NE3304-138
1000BASE-T Adapter (2 port)
Broadcom BCM5718 PCIe 2.0(x4) (Performance: PCIe 2.0(x1)) Low Profile
NE3304-132
1000BASE-T Adapter (4 port)
Broadcom BCM5719 PCIe 2.0(x4), Low Profile
NOTE:
- Network cables with RJ-45 plug covers cannot be used.
NE3304-133
10GbE
10GBASE Adapter (SFP+/2ch)
Broadcom NetXtreme II BCM57711 10G SFP+ Dual Port Network Interface Card
PCIe 2.0(x8), Low Profile
NOTE:
- NE3304-129 (SFP+ Module (10G-SR)) needs to be ordered per one
port (max. 2)
- Connection with Twinax cable is available. Please refer to the Users guide for the validated cable
NE3304-128
SFP+ Module (10G-SR)
1 x SFP+ Module for NE3304-128
NE3304-129
NOTE:
Network Interface Controller not pre-installed. Needs to order at least 1 card. WOL (Wake On LAN) / PXE (Preboot eXecution Environment boot is supported by 1000BASE-T
Adapter (1 port) (NE3304-138) and 1000BASE-T Adapter (2 port) (NE3304-132.
When booting OS by PXE boot, please select IPv4 for network settings.
Page 38
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
38
NIC Teaming feature – NIC Teaming and bonding features
NIC Teaming and bonding features are available with this server to provide network redundancy and load balancing for higher network reliability and optimized network loads.
Under Windows Server 2008 R2 SP1 environment, teaming feature is supported with BASP (Broadcom Advanced Server Program). Under Windows Server 2012 (and later) and Linux environement, network redundancy is supported with Taming/Bonding functions supported by OS.
See the table below for supported network interfaces, operation mode and number of teams.
Windows Teaming (1) Windows Server 2008 R2 SP1
Network Interface
Operation Mode
Configuration
Number of Teams
NE3304-138/-132/-133 (1000BASE)
Smart Load Balancing and
Failover (without Standby Member feature)
Smart Load Balancing
(Auto-Failback Disable) (with Standby Member feature)
FEC/GEC Generic
Trunking
4 ports in on card 4 ports among
multiple cards
Up to 4 ports per one team Up to 4 teams per one
system
NE3304-128 (10GBASE-SR)
Smart Load Balancing and
Failover (without Standby Member feature)
Smart Load Balancing
(Auto-Failback Disable) (with Standby Member feature)
FEC/GEC Generic
Trunking
2 ports in one
card
2 ports among
multiple cards
Up to 2 ports per one team Up to 4 teams per one
system
NOTE:
Teaming with one port shared among multiple teams: Not supported Teaming between 1000BASE-T card and 10GBASE-SR card: Not supported Teaming is NOT available when using Windows Server 2008 R2 SP1 ServerCore Can mix 1000BASE-T teaming and 10GBASE-SR teaming within one system. In this case, up to 4 teams
are supported per one system.
In case of using 10GBASE-SR:
Needs to set less than 4000byte for Jumbo frame, in case of Flow Control set other than
Disabled
Teaming of the port using iSCSI: Not supported
(2) Windows Server 2012 (and later)
Network Interface
Operation Mode
Configuration
Number of Teams
NE3304-138/-132/-133 (1000BASE-T)
Generic or static
Teaming
Dynamic teaming Switch-independent
4 ports in on card 4 ports among
multiple cards
Up to 4 ports per one team Up to 16 teams
NE3304-128 (10GBASE-SR)
2 ports in one card 2 ports among
multiple cards
Up to 2 ports per one team Up to 8 teams
NOTE:
Teaming with one port shared among multiple teams: Not supported Teaming between 1000BASE-T card and 10GBASE-SR card: Not supported Teaming of the port using iSCSI: Not supported
Page 39
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
39
Linux Bonding
Network Interface
Operation Mode
Configuration
Number of Bonding
NE3304-138/-132/-133 (1000BASE-T)
Recommend: active-backup (fault-tolerance)
2 ports in one card 2 ports among
multiple cards
Up to 2 ports per one
bonding
Up to 16 teams
NE3304-128 (10GBASE-SR)
Recommend: active-backup (fault-tolerance)
2 ports in one card 2 ports among
multiple cards
Up to 2 ports per one
bonding
Up to 8 teams
NOTE:
Teaming between 1000BASE-T card and 10GBASE-SR card: Not supported Concatct to our sales representative for other than Active-backup Can mix 1000BASE-T bonding and 10GBASE-SR bonding within one system
6.2 Using iSCSI
Please refer to iStorage web site regarding the connection to iStorage Series via iSCSI, and to EXPRESSCLUSTER web site for cluster configuration.
See the table below for supported network interface and OS combinations.
Network Interface
Operating System
10GbE
NE3304-128
Windows Server 2008 R2 SP1/ Windows Server 2012 / Windows Server 2012 R2 /RHEL / VMware
RHEL : Red Hat Enterprise Linux
NOTE:
NIC Teaming/Bonding features are not supported on iSCSI interfaces. When booting OS by iSCSI, please select IPv4 for network settings.
Page 40
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
40
6.3 External Storage Controller
6.3.1 RAID Controller
Category
Product Name/Description
Part Number
Controller
External RAID Controller (1GB, RAID 0/1/5/6/10/50/60)
LSI MegaRAID SAS 9286CV-8e
RAID0/1/5/6/10/50/60, 1GB Cache, External 8 port (4x2 connector), PCIe 3.0(x8), SAS 6Gb/s, Low Profile
NE3303-H001
Backup Unit
Flash Backup Unit
Flash Backup Unit (for NE3303-H001)
NE3303-H002
NOTE:
This External RAID Controller [NE3303-H001] can connect to NECs Disk Expansion Unit (2U
[N8192-101][N8192-102]).
SAS Cable (2m): [K410-191(02)] Disk Expansion Unit can be placed just above or just below the server.
BTO configuration at the server delivery does NOT include RAID configuration. Please do RAID
configuration by using utility setting.
By using Flash Backup Unit, Write Back is available. When configuring Flash Backup Unit, the External RAID Controller is not BTO configured at the server
delivery. In order to configure Flash Backup Unit in BTO, please order NE3300-SV401 (Customized Service: PCI Cards)
To configure a large-capacity RAID array, it is recommended to configure in RAID 6 or RAID 60 sith 2x
HDDs in order to minimize the risk of becoming multiple hard drives failure during the RAID rebuilding process.
It is recommended to set RAID array configuration drives less than eight in order to minimize the risk
of becoming multiple hard drives failure.
When using VMware ESXi5.5, please download the latest SMI-S provider from our web site.
Page 41
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
41
6.3.2 Fibre Channel / SAS Controller
Category
Product Name/Description
Part Number
Fibre Channel
Fibre Channel Controller (8G/1 port)
Emulex LightPulse LPe1250-F8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0(x8), Low Profile
NE3390-153
Fibre Channel Controller(8G/2 port)
Emulex LightPulse LPe12002-M8 Host Bus Adapter 8Gb/s, Optical, PCIe 2.0(x8), Low Profile
NE3390-154
Fibre Channel Controller (16G/1 port)
Emulex LightPulse LPe16000B-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0(x8), Low Profile / Full Height
Not supported with VMware® ESXi 5.1 U2
NE3390-157
Fibre Channel Controller (16G/ 2port)
Emulex LightPulse LPe16002B2-M6 Host Bus Adapter 16Gb/s, Optical, PCIe 3.0(x8), Low Profile / Full Height
Not supported with VMware® ESXi 5.1 U2
NE3390-158
SAS
SAS Controller
LSI SAS9212-4i4e Host Bus Adapter 6Gb/s SAS, PCIe 2.0(x8), Low Profile
NE3303-142
NOTE:
Connection to iStorage M Series via SAS under Linux environment: Not supported Please refer to the iStorage website for the supported device and OS by iStorage series Please refer to the EXPRESSCLUSTER web site for cluster configuration The type and length of the cable depends on Fibre Channel (FC) link speed. Please refer to the
Technical Guide for the details.
Depending on the FibreChannel(FC) link speed, the available cable type and/or length may differ. Please
refer to the users guide for the Fibre Channel Controller.
As 2m cables are used to connect SAS Controller and Device Expansion Unit, the following remarks
should be noted when using Device Expansion Unit.
Device Expansion Unit (2U): N8141-59 Can be mounted with the space less than 3U with the server (on top or under).
When moungint Device Expansion Unit on top or just under the server, all devices (1-4)
can be connected.
When mounting Device Expansion Unit with 1 – 3U space, device 3 and 4 (left side of the
Unit in fromt view / connector 3 and 4 of right side from rear view) can be connected. Among the space between the Device Expansion Unit and the server, the item with less
than 660mm in lengh can be mounted. Device Expansion Unit (1U): N8141-48 Can be mounted only on top or just under the server.
Only the device 2 (left side of the Unit in front view / connecter 2 of right side from rear
view) can be connected
Page 42
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
42
6.4 PCIe SSD
Super high speed SSD board to be installed in PCIe slot
Product Name/Description
Part Number
1.1TB PCIe SSD (*CTO*)
HGST FlashMAX II Performance 1100GB MLC Card PCIe 2.0(x8), Low Profile
Supported OS: Windows Server® 2012, Windows Server® 2012 R2
NE3318-H001F
NOTE:
(*CTO*) CTO categorized item; lead time for delivery is different from other item. Please contact to our
sales representative for the delivery schedule.
3GB main memory is required per one 1.1TB PCIe SSD This PCIe SSD is for NECs solution set product Database Solution with Microsoft SQL Server (including
“PSAM”, NEC PCIe SSD Appliance for Microsoft® SQL Server®) with the following condition for use:
In order to optimize the system performance, please order the Service Product below, one per
each server
Supporting Storage Pool/Mirror Volume configuration only Page File not supported
Please contact to our sales representative for the use other than the above.
PSAM Customized Service
Product Name/Description
Part Number
PSAM Customized Service
NE3300-SV406
Page 43
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
43
7 Other Add-in Components
7.1 Power Supply Unit
7.1.1 Number of Power Supply Unit
See the table below for the required number of Power Supply Unit per voltage/configuration/redundancy.
Voltage
Model
Power Supply
Unit
# of
CPU
Number of Power Supply Unit
No-redundancy
N+1
2N
200V
A2040b
1000W
2/3/4 2 3
4
800W
2 2 3
4
3/4 3 4
Not available
A2020b
1000W 2 2 3 4
800W 2 3
4
Not available
A2010b
1000W 1 2 3 4
800W 1 2 3 4
A1040b
1000W
1 1 2
2
2/3/4 2 3
4
800W
1/2 2 3
4
3/4 3 4
Not available
100V
A2040b
1000W
2/3 2 3
4
4 3 4
Not available
800W
2 2 3 4 3/4 3 4
Not available
A2020b
1000W 2 3
4
Not available
800W 2 3
4
Not available
A2010b
1000W 1 2 3 4
800W 1 2 3 4
A1040b
1000W
1 1 2 2 2/3 2 3
4
4 3 4
Not available
800W
1/2 2 3 4 3/4 3 4
Not available
NOTE:
When selecting Power Supply Unit, recommend to consider potential add-on of the optional products in
the future.
Redundancy can be selectable; no-redundancy, N+1 and 2N:
N+1: When one Power Supply Unit fails, the operation can continue.
2N: Configuring 2 power supply groups, each consisting of 1 or 2 power supply unit. When one group fails, the operation can continue with another group. In this case, power supply is redundant between PSU#1 and PSU#2, or PSU#3 and #4. Please configure power supply path appropriately.
Hot-plug supported. Can replace Power Supply Unit without stopping the system (under redundant
configuration securing enough power during replacement).
Page 44
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
44
7.1.2 Power Supply Unit
AC Power Supply Unit
Product Name/Description
Part Number
Power Supply Unit (800W)
Hot-plug, 80 PLUS Platinum certified
NE3381-87
Power Supply Unit (1000W)
Hot-plug, 80 PLUS Platinum certified
NE3381-88
NOTE:
Up to 4 units can be installed. Power Supply Unit includes Cable Tie to prevent dropping AC cable. Cannot mix different Power Supply Unit Cannot mix 100V/200V in one server Please prepare AC cables compliant to the regulation in each geography.
7.2 Redundant Fan Kit
Product Name/Description
Part Number
Redundant Fan
2x fan module
(standard)
NOTE:
2 units are installed as standard (no add-on available). Hot-plug supported
7.3 Trusted Platform Module Kit
Product Name/Description
Part Number
Trusted Platform Module Kit
Module needed to use Windows BitLocker Drive Encryption feature
NE3315-19
NOTE:
This is to be shipped only at the delivery of the server (cannot be add-on later). When installed in the server, cannot be removed later.
Need to enable TMP Support in BIOS Set-up Menu to use this item. Need to save recovery password for Windows BilLocker Drive Encription, as the password is necessary
to recover the data when replacing the hardware in failure.
Page 45
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
45
7.4 Internal Flash Memory
Product Name/Description
Part Number
Internal Flash Memory
With this kit, EXPRESSBUILDER can be started from POST.
NE3315-07
NOTE:
When this flash memory is ordered and shipped with the server, the data in the EXPRESSBUILDER is
copied into this kit.
When this flash memory is ordered and shipped separately, the data must be copied from the
EXPRESSBUILDER DVD to the flash memory after installing it in the server for use.
Page 46
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
46
8 Add-on Components
8.1 17-inch LCD Console Unit
Category
Product Name/Description
Part Number
Drawer w/ KVM
Drawer
17-inch LCD Console Drawer (8port)
17-inch LCD, US 83-keys Keyboard, Optical mouse, 8 port KVM switch, 1U height
N8143-77F
Cable
Switch Unit Connection Cable Set (USB, 1.8m)
1.8 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(1A)
Switch Unit Connection Cable Set (USB, 3m)
3 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(03)
Switch Unit Connection Cable Set (USB, 5m)
5 m, 1 x 15-pin mini D-sub to 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(05)
Drawer w/o KVM
Drawer
17-inch LCD Console Unit 1U
17-inch LCD, US 83-keys Keyboard, Optical mouse, 1U height, 4-pin USB B to 4-pin USB A cable 2 m, PS/2 Y-splitter cable 2m, 15-pin mini D-sub VGA cable 2 m
N8143-76F
17inch LCD Console Drawer (1port)
17-inch LCD, US 103-keys Keyboard with 10-key, Touch pad with 3-button, 1U height, 4-pin USB B to 4-pin USB A cable 1.8 m, Two PS/2 cable 1.8 m, 15-pin mini D-sub VGA cable 1.8 m
N8140-84F
Keypad
Keyboard Unit (JP)
JP 108-keys Keyboard with 10-key for N8143-84F 17inch LCD Console Drawer (1port)
N8143-85
Keyboard Unit (UK)
UK 104-keys Keyboard with 10-key, for N8143-84F 17inch LCD Console Drawer (1port)
N8143-87
Page 47
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
47
8.2 KVM Switch
Category
Product Name/Description
Part Number
KVM Switch
Server Switch Unit (8Server)
1U USB 8 port KVM Switch
N8191-12F
Cable
Switch Unit Connection Cable Set (USB,1.8m)
1.8 m, 1 x 15-pin mini D-sub - 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(1A)
Switch Unit Connection Cable Set (USB,3m)
3 m, 1 x 15-pin mini D-sub - 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(03)
Switch Unit Connection Cable Set (USB,5m)
5 m, 1 x 15-pin mini D-sub - 1 x 15-pin mini D-sub / 1 x 4-pin USB A
K410-118(05)
Cascading
Switch Unit Connection Cable 1.8 m
1.8 m, 1 x 15-pin mini D-sub - 1x 15-pin mini D-Sub / 2x PS/2
K410-119(1A)
Page 48
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
48
8.3 Front Bezel
A2040bA2020b, A2010b
Product Name/Description
Part Number
Front Bezel (A2040b/A2020b/A2010b)
NE3446-H001
A1040b
Product Name/Description
Part Number
Front Bezel (A1040b)
NE3346-H001
Page 49
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
49
8.4 Cable Arm
With this component at rear side of the server, various cables are compactly combined.
Product Name/Description
Part Number
Cable Arm 70mm
Including slide rail attachment Able to combine around 18 cables (except AC Power Cable, such as LAN, FC and USB)
NE3343-H001
Cable Arm 110mm
Including slide rail attachment
Able to combine around 32 cables (except AC Power Cable, such as LAN, FC and USB)
NE3343-H002
NOTE:
Need to use Slide Rail Attachment to use Cable Arm. This makes server depth longer, as shown in the
Dimensions.
For calculation, considering LAN (UTP: without shield) is φ5mm in diameter at average, 1x FC cable
corresponds to 1x LAN cable, 1x SAS cable corresponds to 2x LAN cables, 1x SUV cable corresponds to 4x LAN cables and 1 x USB Cable corresponds to 1 x LAN cable.
Table for quick reference:
Model
A2040b/A2020b/A2010b
A1040b
Cable Arm
(70mm)
Cable Arm
(110mm)
Cable Arm
(70mm)
Cable Arm
(110mm)
18
32
18
32
Management LAN (mandatory required)
2 2 1
1
SUV Cable (mandatory required)
*1
(by no. of LAN cable)
4 4 4
4
Opne calbe capacity
(byno. Of LAN cable)
12
26
13
27
1
1 x SUV Cable corresponds to 4 x LAN cable.
Remarks:
With Cable Arm (110mm), the unit with more than 650mm in depth (from the front) cannot be located on
top of the server. Need to have 1U between the unit and the server.
Page 50
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
50
8.5 Management Console Specifications
Need to prepare a PC for a management console meeting the following requirements:
Specifications
CPU
More than Pentium4 1.3GHz
Memory
More than 2GB (Memory for OS and browser + memory for Java + more than 1GB)
Network
100BASE-TX equivalent and above (bandwidth more than 10Mbps)
HDD
More than 40GB free space
Resolution
More than 1152 x 864
Supported browser
Windows
- Microsoft Internet Explorer 7.0, 8.0, 9.0, 10.011 not supported * with IPv6
- Microsoft Internet Explorer 10.0
Linux
- Firefox ESR17
Java
Oracle Java JRE7 * 32bit version J2SE Runtime Environment
Client OS
Windows
- Windows Vista(SP2)
- Windows 7
- Windows 8
- Windows Server 2003 R2 (SP2)
- Windows Server 2008
- Windows Server 2008 R2 (SP1)
- Windows Server 2012 * with IPv6
- Windows 7
- Windows 8
- Windows Server 2012
Linux
- Red Hat Enterprise Linux WS(version 6.0 or later)
- Red Hat Enterprise Linux(version 6.0 or later)
NOTE:
For A2040b/A2020b/A2010b, management console needs to be connected to Management LAN of both
MGB#1 and MGB#2.
For A1040b, management console needs to be connected to Management LAN of MGB#1 LAN environment/console PC is not pre-installed. Needs to prepare separately. Needs to have a management console in addition to VGA console. Please prepare at least 1 console.
Can be shared by multiple servers.
Page 51
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
51
References
CPU
CPU: BTO Configuration Rule
CPUs are to be installed in the priority order of CPU1 => CPU2 => CPU3 => CPU4.
Memory
1. Memory Riser Card: Priority/Order of Installation 1-1.A2040b
1 or 2 Memory Riser Cards are able to be installed per CPU. In case of 4CPU configuration, up to 8 Memory Riser cards are able to be installed
The priority/order of instalaltion depends on the models:
(1) Standard Model
Depending on the number of the installed CPU and the ordered Memory Riser Card, Memory Riser Cards will be installed in the following priority/order.
(Need to install at least one Memory Riser Card.)
# of CPU
Memory Riser Card Slot
#1
#2
#3
#4
#5
#6
#7
#8
2
1 3 2
4
- - -
3
1
4
2 5 3
6
4
1
5
2 6 3 7 4
8
(2) COPT Supported Model: Standard BTO Configuration (Centralized Mode)
Depending on the number of the installed CPU and the ordered Memory Riser Card, Memory Riser Cards will be installed in the following priority/order. This priory/order corresponds to the case using Centralize for Core Optimization Mode.
(Need to install at least one Memory Riser Card.)
# of CPU
Memory Riser Card Slot
#1
#2
#3
#4
#5
#6
#7
#8
2
1
2
3
4
- - -
3
1
2
3 4 5 6 - - 4
1
2
3 4 5 6 7
8
Page 52
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
52
(3) COPT Supported Model: With Customized Service: Distribution Mode for COPT (NE3300-SV101) is ordered (Decentralized Mode)
Depending on the number of the installed CPU and the ordered Memory Riser Card, Memory Riser Cards will be installed in the following priority/order. This priory/order corresponds to the case using Decentralize for Core Optimization Mode.
(Need to install at least one Memory Riser Card.)
# of CPU
Memory Riser Card Slot
#1
#2
#3
#4
#5
#6
#7
#8
2
1
3
2
4
- - -
3
1
4
2 5 3 6 - - 4
1 5 2 6 3 7 4
8
1-2.A2020b
Up to 8 Memory Riser cards are able to be installed Depending on the number of the ordered Memory Riser Card, Memory Riser Cards will be installed in the
following priority/order. (Need to install at least one Memory Riser Card.)
# of CPU
Memory Riser Card Slot
#1
#2
#3
#4
#5
#6
#7
#8
2
1 3 2 4 5 7 6
8
1-3.A2010b
Up to 4 Memory Riser cards are able to be installed Depending on the number of the ordered Memory Riser Card, Memory Riser Card will be installed in the
following priority/order. (Need to install at least one Memory Riser Card.)
# of CPU
Memory Riser Card
Slot
#1
#2
#3
#4
1
1 2 3
4
1-4.A1040b
1 or 2 Memory Riser Cards are able to be installed per CPU. In case of 4CPU configuration, up to 8 Memory Riser cards are able to be installed
Depending on the number of the installed CPU and the ordered Memory Riser Card, Memory Riser Cards will be installed in the following priority/order.
(Need to install at least one Memory Riser Card.)
# of CPU
Memory Riser Card Slot
#1
#2
#3
#4
#5
#6
#7
#8
1
1
2
- - - - -
2
1
3
2
4
- - -
3
1
4
2 5 3 6 - - 4
1 5 2 6 3 7 4
8
Page 53
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
53
2. Memory on the Memory Riser Card (DIMM): Priority/Order of Installation
The priority/order to install DIMM on a Memory Riser Card depends on memory configuration. Memory Configuration Mode consists of 2; Independent Mode for high performance and Lockstep Mode
for high availability Under each mode, there are 2 features to improve availability further; Memory Mirroring and Memory Rank
Sparing.
2-1. Lockstep Mode
Lockstep Mode supports Error Detect/Correct toward 2x DRAM failures (DDDC) by having a pair of memory defined among 2x memory channels (CH0 and CH1 or CH2 and CH3) operating in parallel. To use this mode, need to order memory set including 2 DIMMs per set.
NOTE:
Cannot mix RDIMM and LRDIMM in a server Lockstep Mode is a standard setting at the server delivery.
For DIMM installation priority/order, (1) to install larger DIMM first, and (2) to install DIMMs to the sockets in the priority/order shown in the figure below.
2-2. Independent Mode
Independent Mode provides more performance by having 4 memory channels operate independently. This supports Error Detect/Correct toward 1x DRAM failure (SDDC). To use this mode, need to order memory set including 2 DIMMs per set.
NOTE:
Cannot mix RDIMM and LRDIMM in a server Lockstep Mode is a standard setting at the server delivery. To use Independent Mode, need to change
the mode from BIOS set-up menu.
For DIMM installation priority/order, (1) to install larger DIMM first, and (2) to install DIMMs to the sockets in the priority/order shown in the figure below. Otherwise, memory might not be able to be identified.
DIMM Installation Order for Independent Mode (only) /Lockstep Mode (only)
Page 54
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
54
2-3. Memory Mirroring
Memory Mirroring provide redundancy by writing the same data into 2x memory among different memory buffers on a Memory Riser Card. To use this feature, need to order memory set including 4 DIMMs per set
Memory Mirroring for each Memory Configuration Mode:
Independent Mode: Mirroring between CH0 and CH2, CH1 and CH3
Lockstep Mode: Mirroring between memory pair on CH0 and CH1 AND memory pair on CH2 and CH3
NOTE:
Cannot mix RDIMM and LRDIMM in a server When using Memory Mirroring, the available memory capacity becomes half of physical capacity. Lockstep Mode + Memory Mirroring is a standard setting at the server delivery. To use Independent
Mode, need to change the mode from BIOS set-up menu.
Cannot use both Memory Mirroring and Memory Rank Sparing at the same time.
For DIMM installation priority/order, (1) to install larger DIMM first, and (2) to install DIMMs to the sockets in the priority/order shown in the figure below.
DIMM Installation Order for Memory Mirroring
Page 55
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
55
2.4 Memory Rank Sparing
Memory Rank Sparing is the feature to keep operation; with having one of two memory ranks in one memory channel as a spare, when detecting errors at memory rank in operation, automatically switching to spare rank. To use this feature, need to order memory set including 4 DIMMs per set
Memory Rank Sparing for each Memory Configuration Mode:
Independent Mode: One of two memory rank in each memory channel is assigned as a spare memory rank Lockstep Mode: Either a memory pair on CH0 and CH1 OR a memory pair on CH02 and CH03 is assigned
as a spare memory rank.
NOTE:
Cannot mix RDIMM and LRDIMM in a server When using Memory Rank Sparing, the available memory capacity reduces by the capacity of spare
memory rank:
Available Memory Capacity:
1/2 of physical memory (8GB RDIMM) 3/4 of physical memory (16GB RDIMM) 7/8 of physical memory (32GB LRDIMM) 3/4 of physical memory (64GB LRDIMM)
Lockstep Mode + Memory Rank Sparing is a standard setting at the server delivery. To use Independent
Mode, need to change the mode from BIOS set-up menu.
Cannot use both Memory Mirroring and Memory Rank Sparing at the same time.
For DIMM installation priority/order, (1) to install larger DIMM first, and (2) to install DIMMs to the sockets in the priority/order shown in the figure below.
DIMM Installation Order for Memory Rank Sparing
Page 56
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
56
3. Memory in the Server: Priority/Order of Installation
Basic Rule:
When mixing different capacity of memory, will install larger capacity memory first. In a Memory Riser Card, memory installed according to the rule shown in the previous section.
3-1. A2040b
(1) Standard Model
Memory will be installed equally among each Memory Riser Card.
(2) COPT Supported Model: Standard BTO Configuration (Centralized Mode)
Memory will be installed to the first younger 2 Memory Riser Cards. Follows the same rule afterwards,
(3) COPT Supported Model: With Customized Service: Distribution Mode for COPT (NE3300-SV101) is ordered (Decentralized Mode)
Memory will be installed equally among each Memory Riser Card.
3-2. A2020b
Memory will be installed equally to Memory Riser Card #1 to #4, then move to Memory Riser Card #5 to #8.
3-3. A2010b
Memory will be installed equally to Memory Riser Card #1 to #2, then move to Memory Riser Card #3 to #4.
3-4. A1040b
Memory will be installed equally among each Memory Riser Card.
Page 57
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
57
Internal Drive
Internal Drive: Priority/Order of Installation
At the initial server delivery, internal drives are installed with the following priority/order. If the ordered configuration is not in the scope of the rule, the drive will be delivered as not configured.
1x RAID Controller
Slot 0 => Slot 1 => Slot 2 => Slot 3 => Slot 4 => Slot 5 => Slot 6 => Slot 7
2x RAID Controller
For the 1st RAID Controller
Slot 0 => Slot 1 => Slot 2 => Slot3
For the 2nd RAID Controller
Slot 4 => Slot 5 => Slot 6 => Slot 7
However, the 2nd RAID Controller and the drives under the controller are not installed (configured) at the server delivery.
Conditions to Mix Internal Drives
Mixing SSDs with different capacity or mixing HDDs with the same rotation speed is supported in the
BTO configuration.
Mixing HDDs with different rotation speed and mixing HDD and SSC is NOT supported in the BTO
configuration.
Cannot mix within the same RAID group (pack) When defining hot spare disk under mixed drive configuration, need to set Dedicated Hot Spare per
RAID group. Global Hot Spare is not available.
Please refer to the following for further details.
With different internal drives
For 1x RAID Controller, 2 kinds of HDDs or HDD/SSD can be mixed.
When SSD/HDD mixed, SSDs are installed first according to the above priority/order, then HDDs
are installed in the remaining drive bays.
When SSDs with different capacity are mixed, larger SSDs are installed first. When HDDs with different rotation speed, higher speed HDDs are installed first. If the speed is
the same, smaller capacity HDDs are installed first.
Slot 0
Slot 1
Slot 2
Slot 3
Slot 4
Slot 5
Slot 6
Slot 7
Front View (lower)
Page 58
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
58
Page 59
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
59
Standard RAID Configuration at the Initial Server Delivery
Standard RAID configuration for the same type of internal drives at the initial server delivery is as follows RAID 50 and RAID 60 are not supported for BTO configuration
Controller
(reference section)
# of Drive
Standard RAID Configuration
NE3303-168 or NE3303-173
(Q’ty 1)
4.2.1
4.2.2 (up to 8 drives)
1
RAID 0 (Qty 1)
2
RAID 1 (Qty 2)
38
RAID 1 (if the number of drive is odd, will set one spare drive.)
NE3303-168 or NE3303-173
(Q’ty 2)
4.2.4
4.2.5 (Up to 4 drives)
1
RAID 0 (Qty 1)
2
RAID 1 (Qty 2)
3~4
RAID 1 (if the number of drive is odd, will set one spare drive.)
NOTE
Up to 4 RAID group (pack) per server 2
nd
RAID Controller (and 5th and later HDDs under it): no RAID Configuration applied
Need to order same capacity/rotation speed drives in one group (disk array) for RAID configuration at
BTO configuration.
Initial settings of RAID Controller is as follows:
NE3308-168: Write Back (as Flash Backup Unit included) NE3308-173: Wrhite Through (in case of no additional battery)
When needing higher performance, recommend Write Back with additional battery.
Page 60
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
60
Server Management
The EXPRESSSCOPE Engine SP3, integrated into the server (service processor (BMC)), provides superior remote control and system management features listed in the table below.
Standard
Hardware Monitoring
Temperature/HDD/fan/voltage/power/ Degradation (memory/HDD etc.)
Hardware configuration information collection
Hardware event log collection
Boot Monitoring
POST/BIOS stall, Booting, OS panic, Shutdown
1
Alerting
HW error, Boot error and OS panic (by SNMP, E-mail)
Remote KVM (via LAN)
POST/BIOS setup, ROM utility
Boot screen, Panic screen
CUI-based screen (OS console)
GUI-based screen (OS console
Remote Control (via LAN)
Remote reset/Power on-off/dump
Remote power capping
BIOS/BMC FW update
Remote BIOS setup (partial configuration only)
OS shutdown
1
Remote media (CD/DVD/FD/USB)
CLP (Command Line Protocol) (DMTF compliant)
Remote control via Web browser (multi user login at the same time)
Scheduling (without UPS, ESMPRO/SM required)
1
Maintenance
EXPRESSSCOPE® Profile Key (Backup/restore BIOS/BMC setup information)
Others
Set automatic IP address via DNS/DHCP
LDAP/Active Directory verification/user control
Clock synchronization of main unit and the RTC
Access log collection
IPv6 supported
2
BMC Failover
When master BMC fails, switch to stand-by BMC
3
Industry standard
IPMI
2.0
1
Not supported under VMware environment
2
IPv6 is available only for Web console, SMASH-CLP and E-Mail alerting
3
Features to recovery EXPRESSSCOPE Engine SP3 itself. Supoprted only for A2040b/A2020b/A2010b.
Reboot required to failover to stand-by BMC. Need to connect master and stand-by BMC to 2 Management LAN interface from 2 Management LAN ports.
Page 61
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
61
PCI Slot: Available Slots and Installation Limitations
A2040b (including COPT model)/A2020b/A2010b
Available Slots
Installation Limitations
Some PCI cards using I/O space has limitation regarding the number of cards to be installed. Please see the tables below.
NOTE:
Please refer to the Users Guide for the details about each card. “Card Perf.” Means the maximum operating performance of the card. If the PCI slot specification is lower than the operation performance of the cards, the card operates according to the specification of
the slot.
PCI Slot #2 to #9 are hot plug supported.
PCI Slot Specifications #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16
Part Number 4 9 13
16
NE3303-168 Y Y
- - - - - - - - - - - - - -
Flash Backup Unit included
NE3303-173 Y Y - - - - - - - - - - - - - -
Battery Backup Unit [NE3303-153] can be added
NE3303-H001 Y Y Y Y Y Y Y Y*3 Y*3 Y Y Y Y Y Y Y 4 9 11 13
To connect to Disk Expansion Unit
Flash Backup Unit [NE3303-H002] can be added *2
NE3303-142 Y Y Y Y Y Y Y Y*3 Y*3 Y Y Y Y Y Y Y 4 9 11 13
NE3390-153
Y Y Y Y Y Y Y Y*3 Y*3 Y Y Y Y Y Y Y 4 9 11 13
NE3390-154 Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y 4 7 11 13
NE3390-157
Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y 4 7 11 13
NE3390-158 Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y 4 7 11 13
NE3304-138 Y Y Y Y Y*1 Y Y Y Y*1 Y Y Y Y Y Y Y
4 9 13 14
NE3304-132 Y Y Y Y Y*1 Y Y Y Y*1 Y Y Y Y Y Y Y 4 9 13 14
NE3304-133 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y 4 9 13 14
NE3304-128 Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y 4 7 11 14
NE3318-H001F Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y
4 7 11 12
1.1TB PCIe SSD (Card Perf.: PCI Express 2.0(x8))
1 WOL (Wake On LAN) / PXE (Preboot eXecution Environment) boot supported
2 With Flash Backup Unit installed, External RAID Controller can be installed to PCI Slot#5,#8,#12 and #16 only
3 Used when no more x8 lane PCIe slot available
10GBASE Adapter (SFP+/2ch) (Card Perf.: PCI Express 2.0(x8))
For LAN connection Need to separately order SFP+ Module [NE3304­129], when necessary
Fiber Channel Controller (2 port) (16Gbps/Optical) (Card Perf: PCI Express 3.0(x8))
1000BASE-T Adapter (1 port) (Card Perf.: PCI Express 2.0(x1))
For LAN connection Physical Card: PCI Express 2.0(x4)
1000BASE-T Adapter(2 port) (Card Perf.: PCI Express 2.0(x1))
For LAN connection Physical Card: PCI Express 2.0(x4)
1000BASE-T Adapter (4 port) (Card Perf.: PCI Express 2.0(x4))
For LAN connection LAN cables with RJ-45 plug covers cannot be used
16
To connect to internal disks Up to 2 Controllers can be installed.
RAID Controller (512 MB, RAID 0/1/5/6/10/50/60) (Card Perf.: PCI Express 3.0(x8))
External RAID Controller (1GB, RAID 0/1/5/6/10/50/60) (Card Perf.: PCI Express 3.0(x8))
SAS Controller (Card Perf.: PCI Express 2.0(x8))
To connect external device units
Fiber Channel Controller (1 port) (8Gbps/Optical) (Card Perf.: PCI Express 2.0(x8))
For external Fiber Channel connection
Fiber Channel Controller (2port) (8Gbps/Optical) (Card Perf.: PCI Express 2.0(x8))
Fiber Channel Controller (1port) (16Gbps/Optical) (Card Perf.: PCI Express 3.0(x8))
220mm >
Available Slot
(per CPU configuration)
Total
Part Name/Description
RAID Controller (1GB, RAID 0/1/5/6/10/50/60) (Card Perf.: PCI Express 3.0(x8))
122
2
PCIe Slot
Max. Number of Cards
for Installation
Note
PCIe 3.0
x8 lane
x4 lane
x8 lane
x8 socket
8Gb/s
Low Profile
Part Number
NE3303-168
NE3303-173
NE3303-H001
NE3303-142
NE3390-153
NE3390-154
NE3390-157
NE3390-158
Fibre Channel Controller (2port) (8Gbps/Optical)
Fibre Channel Controller (1port) (16Gbps/Optical)
Fibre Channel Controller (2 port) (16Gbps/Optical)
Part Name/Description
RAID Controller (1GB, RAID 0/1/5/6/10/50/60)
RAID Controller (512 MB, RAID 0/1/5/6/10/50/60)
External RAID Controller (1GB, RAID 0/1/5/6/10/50/60)
SAS Controller
Fibre Channel Controller (1 port) (8Gbps/Optical)
#1 For configuring 4 cards, please contact to our sales rep. for the details.
# of Available
Slot
#1 #3 #4 #5 #2 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16
4
9 13 16
PCIe Slot
No limitation---No limitation
No limitation
--No limitation
Max. 3 (Max. 4 *1)
No limitation
-
Max. 3
Max. 3 (Max. 4 *1)
No limitation
No limitation
Page 62
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
62
A1040b
Available Slots
Installation Limitations
Some PCI cards using I/O space has limitation regarding the number of cards to be installed. Please see the tables below.
NOTE:
Please refer to the Users Guide for the details about each card. “Card Perf.” Means the maximum operating performance of the card. If the PCI slot specification is lower than the operation performance of the cards, the card operates according to the specification of
the slot.
PCI Slot Specifications #1 #2 #3 #4 #5 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16
Part Number 4 9 13
16
NE3303-168
Y Y - - - - - - - - - - - - - -
Flash Backup Unit included
NE3303-173 Y Y - - - - - - - - - - - - - -
Battery Backup Unit [NE3303-153] can be added
NE3303-H001
Y Y Y Y Y Y Y Y*3 Y*3 Y Y Y Y Y Y Y
4 9 12 14
To connect to Disk Expansion Unit
Flash Backup Unit [NE3303-H002] can be added *2
NE3303-142
Y Y Y Y Y Y Y Y*3 Y*3 Y Y Y Y Y Y Y
4 9 12 13
NE3390-153
Y Y Y Y Y Y Y Y*3 Y*3 Y Y Y Y Y Y Y
4 9 12 13
NE3390-154
Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y
4 7 11 13
NE3390-157
Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y
4 7 11 13
NE3390-158
Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y
4 7 11 13
NE3304-138 Y Y Y Y Y *1 Y Y Y Y*1 Y Y Y Y Y Y Y
4 9 13 14
NE3304-132 Y Y Y Y Y *1 Y Y Y Y*1 Y Y Y Y Y Y Y 4 9 13 14
NE3304-133 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y 4 9 13 14
NE3304-128 Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y 4 7 11 14
NE3318-H001F
Y Y Y Y Y Y Y - - Y Y Y Y Y Y Y
4 7 11 12
1.1TB PCIe SSD (Card Perf.: PCI Express 2.0(x8))
1 WOL (Wake On LAN) / PXE (Preboot eXecution Environment) boot supported
2 With Flash Backup Unit installed, External RAID Controller can be installed to PCI Slot#5,#8,#12 and #16 only
3 Used when no more x8 lane PCIe slot available
10GBASE Adapter (SFP+/2ch) (Card Perf.: PCI Express 2.0(x8))
For LAN connection Need to separately order SFP+ Module [NE3304­129], when necessary
Fibre Channel Controller (2 port) (16Gbps/Optical) (Card Perf.: PCI Express 3.0(x8))
1000BASE-T Adapter (1 port) (Card Perf.: PCI Express 2.0(x1))
For LAN connection Physical Card: PCI Express 2.0(x4)
1000BASE-T Adapter(2 port) (Card Perf.: PCI Express 2.0(x1))
For LAN connection Physical Card: PCI Express 2.0(x4)
1000BASE-T Adapter (4 port) (Card Perf.: PCI Express 2.0(x4))
For LAN connection LAN cables with RJ-45 plug covers cannot be used
16
To connect to internal disks Up to 2 Controllers can be installed.
RAID Controller (512 MB, RAID 0/1/5/6/10/50/60) (Card Perf.: PCI Express 3.0(x8))
External RAID Controller (1GB, RAID 0/1/5/6/10/50/60) (Card Perf.: PCI Express 3.0(x8))
SAS Controller (Card Perf.: PCI Express 2.0(x8))
To connect external device units
Fibre Channel Controller (1 port) (8Gbps/Optical) (Card Perf.: PCI Express 2.0(x8))
For external Fibre Channel connection
Fibre Channel Controller (2port) (8Gbps/Optical) (Card Perf.: PCI Express 2.0(x8))
Fibre Channel Controller (1port) (16Gbps/Optical) (Card Perf.: PCI Express 3.0(x8))
220mm >
Available Slot
(per CPU configuration)
Total
Part Name/Description
RAID Controller (1GB, RAID 0/1/5/6/10/50/60) (Card Perf.: PCI Express 3.0(x8))
122
2
PCIe Slot
Max. Number of Cards
for Installation
Note
PCIe 3.0
x8 lane
x4 lane
x8 lane
x8 socket
8Gb/s
Low Profile
# of Available
Slot
#1 #3 #4 #5 #2 #6 #7 #8 #9 #10 #11 #12 #13 #14 #15 #16
4
9
13 16
No limitation
Max. 4
No limitation
-
Max. 3
Max. 4
No limitation
No limitation
PCIe Slot
No limitation---No limitation
No limitation
-
-
Part Number
NE3303-168
NE3303-173
NE3303-H001
NE3303-142
NE3390-153
NE3390-154
NE3390-157
NE3390-158
Fibre Channel Controller (2port) (8Gbps/Optical)
Fibre Channel Controller (1port) (16Gbps/Optical)
Fibre Channel Controller (2 port) (16Gbps/Optical)
Part Name/Description
RAID Controller (1GB, RAID 0/1/5/6/10/50/60)
RAID Controller (512 MB, RAID 0/1/5/6/10/50/60)
External RAID Controller (1GB, RAID 0/1/5/6/10/50/60)
SAS Controller
Fibre Channel Controller (1 port) (8Gbps/Optical)
Page 63
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
63
PCI Card: Priority/Order of Installation
Standard BTO Configuration:
Starting from the PCI cards with higher priority (see the table below), PCI cards are installed to the PCI slots with higher priority among the available slots per CPU configuration (see the table below). The following basic rules are applied to BTO configuration. If any other specific installation requirements, BTO configuration will not be applied.
[Basic Rules for PCI Card Installation]
The 1st RAID Controller needs to be installed to Slot#1.  The 2nd RAID Controller (if any) will not be installed (out of BTO configuration)  When External RAID Controller has Flash Backup Unit (FBU), the External RAID Controller will not be
installed (out of BTO configuration).
When the number of available PCI slot is 9, up to 8x 1000BASE-T Adapter (4 port) can be installed. When the number of available PCI slot is 13, up to 12x 1000BASE-T Adapter (4 port) can be installed, AND
PCI card requiring IO space should be 8 or less except RAID Controller.
When the number of available PCI slot is 16, up to 15x 1000BASE-T Adapter (4 port) can be installed, AND
PCI card requiring IO space should be 8 or less except RAID Controller.
Priority of PCI Cards:
Priority
Product Number
Product Name/Description
Slot for Installation
1
NE3303-168
RAID Controller (1GB)
Can install to Slot #1 only NE3303-173
RAID Controller (512MB)
2
NE3304-132
1000BASE-T Adapter (2 port)
NE3304-138
1000BASE-T Adapter (1 port)
3
NE3390-153
Fibre Channel Controller (8G/1 port)
NE3303-142
SAS Controller
NE3303-H001
External RAID Controller (1GB, w/o FBU
4
NE3390-158
Fibre Channel Controller (16G/ 2port)
Can install to any slot other than Slot #8 and #9
NE3390-157
Fibre Channel Controller (16G/1 port)
NE3390-154
Fibre Channel Controller (8G/2 port)
5
NE3304-128
10GBASE Adapter (SFP+/2ch)
Can install to any slot other than Slot #8 and #9
NE3318-H001F
1.1TB PCIe SSD
6
NE3304-133
1000BASE-T Adapter (4 port)
Page 64
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
64
Priority of PCI Slots:
PCI Slot
Number of Available Slots (per CPU configuration)
4 9 13
16
# 1 Y Y Y Y
# 9
N Y Y
Y
#10 N N Y Y
#14 N N N Y
# 3 Y Y Y Y
# 2 N Y Y Y
#11 N N Y Y
#15 N N N Y
# 4 Y Y Y Y
# 6 N Y Y Y
#12 N N Y Y
#16 N N N Y
# 5 Y Y Y Y
# 7
N Y Y
Y
#13 N N Y Y
# 8 N Y Y Y
NOTE:
The 2nd RAID Controller will not be installed (out of BTO Configuration)
High
Low
Page 65
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
65
With PCI Card Customized Configuration Service (NE3300-SV401)
Starting from the PCI cards with higher priority (see the table below), PCI cards are installed to the PCI slots with higher priority among the available slots per CPU configuration (see the table below). The following basic rules are applied to BTO configuration. If any other specific installation requirements, BTO configuration will not be applied.
[Basic Rules for PCI Card Installation]
When the number of available PCI slot is 13, PCI cards requiring IO space should be 10 at maximum. When the number of available PCI slot is 16, PCI cards requiring IO space should be 13 at maximum. The 1st RAID Controller needs to be installed to Slot#1. The 2nd RAID Controller (if any) will not be
installed (out of BTO configuration)
1000BASE-T Adapter, 1 port and 2 port, needs to be installed to Slot#9 (or, in case of 1CPU
configuration, Slot#5)
External RAID Controller should be installed to Slot#5, #8, #12 or #16.
Priority of PCI Cards:
Priority
Product Number
Product Name/Description
Slot for Installation
1
NE3303-168
RAID Controller (1GB)
Can install to Slot #1 only NE3303-173
RAID Controller (512MB)
2
NE3304-132 (1st)
1000BASE-T Adapter (2 port)
1st card can install to Slot #9 only (or in case of 1CPU configuration, #5)
NE3304-138 (1st)
1000BASE-T Adapter (1 port)
3
NE3303-H001 (+ NE3303-H002)
External RAID Controller (1GB) (+ FBU)
Can install to Slot #5#8#12 and #16 only
4
NE3390-158
Fibre Channel Controller (16G/ 2port)
Can install to any slot other than Slot #8 and #9
NE3390-157
Fibre Channel Controller (16G/1 port)
NE3390-154
Fibre Channel Controller (8G/2 port)
5
NE3390-153
Fibre Channel Controller (8G/1 port)
NE3303-142
SAS Controller
NE3303-H001
External RAID Controller (1GB, w/o FBU
6
NE3304-128
10GBASE Adapter (SFP+/2ch)
Can install to any slot other than Slot #8 and #9
NE3318-H001F
1.1 TB PCIe SSD
7
NE3304-133
1000BASE-T Adapter (4 port)
NE3304-132 (2nd and more)
1000BASE-T Adapter (2 port)
NE3304-138 (2nd and more)
1000BASE-T Adapter (1 port)
Page 66
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
66
Priority of PCI Slots:
PCI Slot
Number of Available Slots (per CPU configuration)
4 9 13
16
# 1 Y Y Y Y
# 9 N Y Y Y
# 8 N Y Y Y
#16 N N N Y
#12 N N Y Y
# 5 Y Y Y Y
# 2 N Y Y Y
#14 N N N Y
#10 N N Y Y
# 3 Y Y Y Y
#11 N N Y Y
#15 N N N Y
#13 N N Y Y
# 6 N Y Y Y
# 7 N Y Y Y
# 4 Y Y Y Y
NOTE:
The 2nd RAID Controller will not be installed (out of BTO Configuration)
High
Low
Page 67
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
67
RAS Feature Matrix (per OS)
(2/1)
RAS Features
OS
A2040b
A2020b
A2010b
A1040b
Note
CPU Core Predictive Failure Analysis (PFA)
EL6.4 x64 or later
Y Y Y Y *1
OL6.4x64
Y Y Y Y *1
2012/R2 Y Y Y Y
*2
2008R2 Y Y Y Y
*2
ESXi5.1u2
N N N N
ESXi5.5 N N N N
Dynamic CPU Core
De-allocation
EL6.4 x64 or later
Y Y Y N *1
OL6.4x64
Y Y Y N *1
2012/R2 N N N N
2008R2 N N N N
ESXi5.1u2
N N N N
ESXi5.5 N N N N
Dynamic Memory Page
De-allocation
EL6.4 x64 or later
Y Y Y N *1
OL6.4x64
Y Y Y N *1
2012/R2 Y Y Y Y
*2
2008R2 Y Y Y Y
*2
ESXi5.1u2
Y Y Y Y
ESXi5.5 Y Y Y Y
MCA Recovery
EL6.4 x64 or later
Y Y Y Y
OL6.4x64
Y Y Y Y *5
2012/R2 Y Y Y Y
2008R2 Y Y Y Y
*5
ESXi5.1u2
N N N N
ESXi5.5 Y Y Y Y
*5
PCIe Error Recovery /
PCIe Error Handling
EL6.4 x64 or later
N N N N
OL6.4x64
N N N N
2012/R2 N N N N
2008R2 N N N N
ESXi5.1u2
N N N N
ESXi5.5 N N N N
Page 68
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
68
(2/2)
RAS Features
OS
A2040b
A2020b
A2010b
A1040b
Note
Static COPT; re-boot required
(COPT Model)
EL6.4 x64 or later
Y N N N *7
OL6.4x64
Y N N N *7
2012/R2 Y N N N
*8
2008R2 Y N N N
*8
ESXi5.1u2
Y N N N
ESXi5.5 Y N N N
Dynamic COPT: Core Enabling
(COPT Model)
EL6.5x64
Y N N N *1
EL6.4x64
N N N N
OL6.4x64
N N N N
2012/R2
TBD N N N
2008R2
N=>Y
N N N
*3*9
ESXi5.1u2
N N N N
ESXi5.5 N N N N
Dynamic COPT: Core Sparing
(COPT Model)
EL6.5x64
Y N N N *1
EL6.4x64
N N N
N
OL6.4x64
N N N N
2012/R2
N N N N
2008R2 N N N N
ESXi5.1u2
N N N N
ESXi5.5 N N N N
Memory Hot-ADD
EL6.5 x64
N=>Y
N=>Y
N=>Y
N
*1*9
EL6.4 x64
N N N N
OL6.4x64
N N N
N
2012/R2
TBD
TBD
TBD N
2008R2
N=>Y
N=>Y
N=>Y
N
*6*9
ESXi5.1u2
N N N N
ESXi5.5 N N N N
PCIe Hot-Add PCIe Hot-Remove
EL6.4 x64 or later
Y Y Y N
OL6.4x64
Y Y Y N
2012/R2 Y Y Y N
2008R2 Y Y Y N
ESXi5.1u2
N N N N
ESXi5.5 N N N N
Page 69
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
69
Legend for OS
EL6.5x64
Red Hat Enterprise Linux 6.5(x86_64)
EL6.4x64
Red Hat Enterprise Linux 6.4(x86_64)
OL6.4x64
Oracle Linux6.4/UEK R2(x86_64)
2012/R2
Windows Server 2012 and 2012R2
2008R2
Windows Server 2008 R2 SP1
ESXi5.1u2
VMware ESXi 5.1 update2
ESXi5.5
VMware ESXi 5.5
NOTE:
*1 Please install the necessary module according to the documents; “Machine Check Monitoring Service
User's Guide” “Capacity Optimization (COPT) User's Guide for Linux” They are additional modules for a specific kernel version.
*2 Please install spport kit (UPDATE module) in the EXPRESSBUILDER. With Windows Seamless Install, the
necessary modules are automatically installed.
*3 Please install the necessary module according to the documents; “Machine Check Monitoring Service
User's Guide” “Capacity Optimization (COPT) User's Guide for Windows” *4 (intentionally blank) *5 Uncorrectable error detected by memory patrol can be recovered, but error recovery for L1 cache is not
supported. *6 Please install the necessary module according to the document “MR HotA-add User's Guide for Windows”. *7 As an option, if you install the necessary module acccording to the documents; “Machine Check Monitoring
Service User's Guide” “Capacity Optimization (COPT) User's Guide for Linux”, then, core allocation among
CPUs can be adjusted. They are additional module for a specific kernel version. *8 As an option, if you install the necessary module according to the documents “Capacity Optimization (COPT)
User's Guide for Windows”, core allocation among CPUs can be adjusted. *9 Planned to be supported in CQ1/2015
Page 70
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
70
Copyright Notice and Liability Disclaimer
The information contained herein is subject to change without notice. Microsoft and Windows Server are either registered trademarks or trademarks of Microsoft Corporation in the
United States and/or other countries Intel and Xeon are registered trademarks or trademarks of Intel Corporation or its subsidiaries in the United
States and other countries. Linux is a trademark of Linus Torvalds. Red Hat is a registered trademark of Red Hat, Inc. in the U.S. All other products, brands, or trade names used in this document are trademarks or registered trademarks of
their respective holders. NEC shall not be liable for technical or editorial errors or omissions contained herein. For hard drive capacity measurements, 1 GB = 1 billion bytes. Actual formatted capacity is less.
Page 71
CONFIGURATION GUIDE – NEC Express5800/A2040b, A2020b, A2010b, A1040b
NEC Corporation Revision 7.0 – December 2014
71
Revision History
Revision
Date
Description
1.0
February 2014
Initial Release
2.0
April 2014
Updates
3.0
June 2014
Updates (RAS Feature Matrix)
4.0
July 2014
Updates (Windows Server 2012 R2 supported)
5.0
September 2014
Updates (4TB support)
6.0
October 2014
Updates (RAS Feature Matrix)
7.0
December 2014
Updates
Loading...