The information disclosed in this document, including all designs and related materials, is
the valuable property of NEC Computers Inc. and/or its licensors. NEC Computers Inc.
and/or its licensors, as appropriate, reserve all patent, copyright and other proprietary
rights to this document, including all design, manufacturing, reproduction, use, and sales
rights thereto, except to the extent said rights are expressly granted to others.
The NEC Computers Inc. product(s) discussed in this document are warranted in
accordance with the terms of the Warranty Statement accompanying each product.
However, actual performance of each such product is dependent upon factors such as
system configuration, customer data, and operator control. Since implementation by
customers of each product may vary, the suitability of specific product configurations and
applications must be determined by the customer and is not warranted by NEC Computers
Inc.
To allow for design and specification improvements, the information in this document is
subject to change at any time, without notice. Reproduction of this document or portions
thereof without prior written approval of NEC Computers Inc. is prohibited.
Trademarks
All products, brands, or trade names used in this publication are the trademarks or registered
Preparing Your Server Unit....................................................................................................................7
Removing the Front Bezel..................................................................................................................7
Removing the Side Panels..................................................................................................................8
Installing the LED Holder and Labels................................................................................................9
Removing a Foot Stand....................................................................................................................13
Installing the New Front Bezel.........................................................................................................15
Installing the Side Panels.................................................................................................................18
Preparing the Mounting Bracket Assemblies...................................................................................19
Attaching the Mounting Bracket Assembly to the Rack..................................................................19
Installing the Server into the System Rack.......................................................................................21
Making Connections.............................................................................................................................23
Connecting the Power Cord.................................................................................................................. 24
Po wering On Your System...................................................................................................................25
Introduction
This guide provides you with assembly information for preparing and mounting
your Express5800/120Ed Server small tower unit into a system rack
(see Figure 1).
Figure 1. Rack Mounted Server Small Tower Unit
Express5800/120Ed Rack Mount installation Procedures 3
Unpacking and Inspection
Although the rack mount kit is inspected and carefully packaged at the factory,
damage may occur during shipping. Follow these steps for unpacking the kit.
1. Visually inspect the shipping container; notify your carrier immediately of
any damage.
2. Place shipping container on a flat, clean, stable surface. Carefully remove
and verify the contents (see Table 1 and Figure 2). If parts are missing or the
equipment is damaged, notify your server representative.
3. Save the container and packing materials for any future reshipment.
Table 1. Rack Mount Kit Parts List (NZA-1203-00-00)
ItemNameDescriptionPart Number
ARail Kit1U Rail Kit includes:
Left Mounting Rail (246-01521-000)
Right Mounting Rail (246-01522-000)
Packet of screws (250-0151-000)
BFront BezelBezel assembly
CPlast ic BagPlastic bag containing four screws and two bezel
assembly handles
DLED HolderLED holder246-01530-000
ESleep LabelSleep sti ck- on labe l405-01580-000
FStatus LabelStatus stick-on label405-01579-000
GName PlateName plate logo stick-on label405-01545-000
HDocument
Installation Guide for the 120Ed Server Small Tower
Rack Mount Kit (This manual)
246-01523-000
890558
455-01607-000
Express5800/120Ed Rack Mount installation Procedures 4
A
C
B
D
E
F
H
G
Express5800
Figure 2. Rack Mount Kit Parts
/120Ed
Express5800/120Ed Rack Mount installation Procedures 5
Before You Begin
Before you begin, please review the following cautions, warnings, and general
guidelines.
Be sure that power to the server unit is turned off and
unplugged. All voltage is removed only when the power cord
is unplugged.
Avoid excessive vibration and shock. Dropping an electronic component can
!
cause serious damage.
Do not disconnect or remove parts other than those specified in the
!
procedure.
Do not touch I/O connector pins.
!
All screws are Phillips-head, unless otherwise specified.
!
On completion of any reassembly, perform a power-on test. If a fault occurs,
!
verify that the reassembly was performed correctly. If the problem persists,
see the Problem Solving chapter in your System User’s Guide.
!
WARNING
What You Need
In addition to the carton contents, the only tools you need are a #2 Phillips,
adjustable crescent wrench, and a utility knife to assemble the server unit.
It is strongly recommended that two people are present
when lifting and installing the server unit into a system rack.
Static Precautions
An electrostatic discharge (ESD) can damage disk drives, option boards, and
other components. You can provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground when handling system components.
Electronic devices can be easily damaged by static electricity. To prevent
damage, keep them in their protective packaging when they are not installed in
your system.
!
CAUTION
Express5800/120Ed Rack Mount installation Procedures 6
Equipment Information
Measurements for the rack are given in Us where 1U is equal to 1.75 inches.
!
Every three holes on the inside of the rack are equal to 1U.
!
The height of the Server Small Tower Unit is 5Us (8.75 inches).
!
Preparing Your Server Unit
To prepare your server small tower unit for rack mounting, you must first
remove the front bezel, the side panels, and the four foot stands on the bottom of
the unit. After the previously mentioned items are removed, then the new front
bezel for rack mounting can be installed on the front of the server unit.
Removing the Front Bezel
!
CAUTION
If you are removing the front bezel after the server unit is set
up, you must first power off the system and all external
devices. Unplug the system power cord
The plastic front bezel assembly on your server unit is a one-piece assembly and
easy to remove.
Note:
1. Power off the server unit and ensure it is disconnected from the ac wall
outlet.
2. Remove the front bezel by carefully pulling it off the front of the server unit
chassis. Use an even amount of pressure around the edges of the bezel.
(see Figure 3).
The front bezel is secured with six locking tabs.