Nebula NBL-S280 User Manual

1
HOT BEAM 280
MOVING HEAD BEAM
Net Weight19KG
POWER470W
2
ITEM
Item...........................................................................................................................02
1.Product introduce ...............................................................................................03
2.Fixture size........................................................................................................... 03
3.Parts introduce.................................................................................................... 04
4.Safety information............................................................................................... 05
5.Packing and shipping ......................................................................................... 07
6.AC power............................................................................................................. 08
7.Lamp model and replace.................................................................................... 08
8.Control Panel...................................................................................................... 11
9.Control panel operate.........................................................................................11
10.DMX Channels................................................................................................. 14
11.PCB Driving board.......................................................................................... 18
STATEMENT
The product is good packing when ship out the factory. All users should strictly abide by the warnings and instructions stated in this manual, any damage and results due to misuse and the neglect of this operating manual will be excluded from the deal responsibility this manual will not informed in additionally if have technical changes.
3
PRODUCTION INTRODUCE
Thank you for choose this HOT BEAM280 products, this model is the moving head light which is the latest development of the smart, efficient products, beautiful shape, smooth R & D, combined with the advanced technology of today's stage lighting products with international advanced electronic control technology and excellent user-friendly industrial design , fully comply with CE standard, accepted international standard DMX512 signal mode. This moving head lights, use ceramic luminescent film reflector as a condenser system, coupled with the high-quality optical lens components, broadband voltage, a clear pattern, sharp and uniform output light efficiency. Intelligent LCD display module, the English language selection mode, intuitive operating menu, shortcut. Hot Beam280, have 16/24 international standard DMX512 channels optional Horizontal scan: 540 ° vertical scanning 270 ° (16bit precision scanning) electronic correction, dot-matrix display, four touch switch LCD + single-Key flying shuttle can spin. The can be inverted 180 °, the color wheel is combined with white and 14 colors. 2 Gobo wheels: 9 patterns + white effect round by 8 prism+ 6 prism and atomization function. 0-100% mechanical dimmer, support mechanical strobe and variable strobe effect, strobe macro function. The optical system of the lens group electric focusing, the beam angle of 0 to 4 ° with overheating protection function Moving head lights are widely used in television, disco, dance halls, nightclubs, large-scale performances and other professional venues
2 FIXTURE SIZE
Size385L×365W×589Hmm
4
3. PARTS INTRODUCE
01
02
03
04
05
06 07
01 Lens 02 Body 03 Tilt Lock 04 Arm 05 Pan Lock 06 Handle 07 Light base
01 02 01 02 03 04 05 06 07
0 Control
panel
02 Control wheel
01 3 Pin dmx In 02 5 Pin dmx in 03 Power switch 04 Power in 05 3 Pin dmx out 06 5 pin dmx out 07 Fuse
5
4. SAFETY INFORMATION
Safety warning message This product is only suitable for professional use, and does not apply to security for other purposes. After you got the lights, please check the package whether have any damage caused by transportation. If there is any damage, do not use this fixture, and please contact the dealer or
manufacturer as soon as possible.
This product is only suitable for indoor, IP20 protection class. Lamps should be kept dry to avoid Moisture, overheating or dusty environment. Prevent lamps come into contact with water or any other liquid. The use of this product should pay attention to: fire, heat, electric shock, ultraviolet radiation, the lamp to explode or Shedding caused serious or fatal injury. Need to read the instructions before use energized or installing. Follow through the operation of security methods and pay attention to the warning signs on the specification and equipment. If you have any problem for how to safely operate the equipment. Please contact your dealer.
4.1 2.1 ANTI-HIGH TEMPERATURE
ta =40°C
Please dont use the equipment if the temperature above 40
4.2 BURST PREVENTION The lens should be changed if had damaged or any problems. Dont change the
non-original manufacturer lens.
Len size128*32mm
4.3 TO PREVENT FALLING WOUNDING
Please dont move the package by one person only. When Hang the fixture, please must verify that the facilities to be able to withstand the weight of the lamps at least 10 times more. Please make sure the Mounting hardware is strong enough no any damage, and insurance for the safety rope as auxiliary security fixed in other facilities will need to verify before installation. Installing or removing the equipment, to make the pulley below the work location
4.4 UA PROTECTION AND THE BULB EXPLOSION Prohibit straight viewpoint with exposed bulbs to avoid UV damage to the eyes;
6
Do not use the equipment without the lens screen and the lid;
The lens and the light head covers should be timely replaced if any damage to rupture The Fixture should be used with the protection screen together.
4.5 PREVENTION OF ELECTIC SHOCK
The electrical connection must only be carried out with corresponding qualifications; Before installing, make sure you use the power voltage lamps must comply with the identified power, voltage and have an overload or leakage protection; Each lamp must be properly grounded, installed in accordance with the relevant standards; Cut off the power when stall or replace the lamp and the fuse; Prohibit the use of a lightning storm or wet environment.
4.6 TO PREVENT BURNING OR FIRE
1. The fixture can be mounted directly on the surface of ordinary combustible
material.
2. Do not short-circuit temperature protection switch or fuse, use the specified type of fuse.
3. The equipment must be installed away from inflammable and explosive materials.
4. The equipment should be projected range of 3 meters away objects and projectiles
temperature less than 60 ° C; ---- 3.0m.
5. Fan or ventilation, at least in the range of 0.5 meters can not be an obstacle.
6. Do not place any object on the lens.
7. Handling at least allow the device to cool for 20 minutes.
8. Do not replace the non-original parts.
4.7 TRANSPORT PROTECT LOCK
In order to protect the light, there is a protect lock; During the transport , the lock will closed keeping the item in safety state.
4.8 ABOUT PACKING
1. Before packed, make sure power is off, and wait for at least 20mins for cooling down.
2. Before clean the fixture, make sure X, Y axis protect lock closed.
3. After packed by plastic bag, high-lift the fixture with two handles besides the product. put the product into the fly-case up-side-down.
4. After packed the product, put the accessory into the accessory case, then closed and lock the fly-case.
5. Fly-case only up stacked two layers. Prohibited upside down
6. When packed with carton box, equipment should be put into the foam first, then set into a carton, pay attention to the vertical position.
Loading...