Neat NOVO Technical Handbook

Handbook for Technical Adminstrators NE41 15013-02 v1.0
NOVO - Technical Handbook
neat
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
© Copyright 2017 NEAT Electronics All rights reserved. Document number: NE41 15013-02 v1.0
Dra date: 2017-09-07 Contact: NEAT Electronics AB
Varuvägen 2 SE-246 42 Löddeköpinge Sweden
Phone: +46 46 70 70 65 Fax: +46 46 70 70 87
www.neat-group.com/se/en infosweden@neat-group.com
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
3
Content
1 Introduction 7
1.1 Intended use 7
1.2 About this handbook 7
2 The main unit 8
2.1 Overview 8
2.2 Buttons 9
2.2.1 Alarm button (B1) 9
2.2.2 Reset button (B2) 9
2.2.3 Extra button (B3) 9
2.3 LEDs 10
2.4 ConneNOVO PSTN/GSMtors on NOVO IP/GSM and 11 11
2.4.1 IP connector (C1) 11
2.4.2 AC connector (C2) 11
2.5 External GSM antenna (EA) 11
2.6 Connectors on NOVO PSTN/GSM and PSTN 12
2.6.1 TELE connector (C1) 12
2.6.2 LINE connectorLINE (C2) 12
2.6.3 AC connector (C3) 12
2.6.4 External GSM antenna (EA) 12
2.6.5 External antenna 13
2.7 On/O button (PS1) 14
2.8 Accumulator lid 15
2.8.1 Replacing the accumulator 16
2.9 Mounting the SIM card 16
2.10 Mounting the NOVO 17
2.10.1 Key holes 17
3 Indications 18
3.1 Visual indications 18
3.1.1 Front LEDs 18
3.1.2 Alarm button (L4) LED indications 19
3.1.3 Reset button LED (L5) indications 19
3.1.4 Extra button LED (L6) indications 19
3.1.5 Control mode LED indications 20
3.1.6 Service mode LED indications 20
3.1.7 Unit boot/startup 20
3.2 Acoustic indications 20
3.2.1 Aer activating an alarm 20
3.2.2 Disconnection signal 20
3.2.3 Warning functions in Idle mode 20
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
4
4 Alarm functions 21
4.1 User initiated alarms 21
4.1.1 Passive alarm 21
4.1.2 Home/Away 21
4.1.3 Presence/Ready 22
4.2 Technical Alarms 22
4.2.1 Radio transmitter surveillance 22
4.3 Accumulator alarm 22
4.4 Automatic test alarm 23
4.5 Battery alarm 23
4.6 Radio interference 23
4.7 Mains failure 23
4.8 Mains return 23
4.9 External alarms 23
5 The alarm call 24
5.1 Call routing 24
5.2 Alarm events 25
5.3 Alarm types 25
5.3.1 Radio equipment alarms 25
5.3.2 Alarms from Alarm button (B1) or Extra button (B3) 25
5.3.3 Internally activated alarms 25
5.3.4 Undened alarm types 25
5.4 Alarm type groups 25
5.5 Alarm sequences 26
5.5.1 Call type 26
5.5.2 Carrier type 26
5.5.3 Call attempts 26
5.5.4 Acknowledgement of the alarm call 27
5.5.5 Repetitions of the sequence 27
5.6 Alarm code 27
5.7 Indications during an alarm call 27
5.8 Protocols 28
5.9 Conversation 29
5.10 Examples 30
5.10.1 Example 1 - a simple alarm sequence 30
5.10.2 Example 2 - SCAIP over IP/GSM 31
5.10.3 Example 3 - NEAT Talk/CPC to an analogue alarm receiver 31
5.10.4 Example 4 - Using Home Phone protocol 32
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
5
6 Programming/conguration modes 33
6.1 General 33
6.2 Control mode (CM) 34
6.2.1 Toggle Alarm button (B1) illumination 34
6.2.2 Change volume 34
6.2.3 Enter Service Mode 34
6.3 Service Mode (SM) 34
6.3.1 Add a transmitter 35
6.3.2 Radio/GSM coverage mode 36
6.3.3 Remove transmitter 36
6.3.4 Set external GSM antenna to On/O 37
6.3.5 Change Home/Away/Passive On/o 37
6.4 Programing NOVO PSTN units with LPP commands 38
7 NOVO Programmer 39
7.1 Installation 39
7.2 Menues 39
7.2.1 File menu 39
7.2.2 Communication menu 39
7.2.3 Option menu 39
7.2.4 Help menu 40
7.3 NOVO Programmer Tabs 40
7.3.1 Basic 40
8 Misc 41
8.1 Real Time Clock (RTC) 41
8.2 Alarm log 41
9 Important 42
9.1 Use and maintenance 42
9.2 Cleaning 42
9.3 Safety Notes 42
9.4 Disposal 43
Appendix A NOVO IP/GSM Mounting holes 44
Appendix B Alarm types and Alarm type groups 45
Appendix C Recommended AC adaptors and accumulators 48
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
6
Document revision history
Revision Date Version Revision details
2017-09-07 1.0 v1.0 dra
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
7
1 Introduction
1.1 Intended use
The Care Phone NOVO is a unit designed for the purpose of providing security and a sense of comfort and safety for the user. The unit is primarily designed for people living in their own apartment or in nursing homes.
1.2 About this handbook
This documentation is mainly a technical handbook but can be used as a user manual for advanced users.
The technical handbook is valid for all versions of NOVO (i.e NOVO IP/GSM, NOVO PSTN/GSM and NOVO PSTN). To determine your version, please refer to the bottom label on your product.
Throughout this technical handbook common functions etc. will be described for all NOVO versions and where applicable the special characteristics for a certain version will be specied.
Information notes and warnings intended for maintenance personnell and/or users are emphasized in these instructions by the pictogram’s dened here.
Pictograms
The Information sign and corresponding text is intended for information which might be useful but not critical for the reader and/or user.
The Warning triangle sign and corresponding text is intended for critical information to which the user and/or reader should pay special attention.
Highlighted text
In the running text certain text is highlighted to emphasize terms etc..
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
8
2 The main unit
NOVO comes in three versions: NOVO IP/GSM, NOVO PSTN/GSM and NOVO PSTN.
2.1 Overview
Care phone NOVO appears as in the picture below. The unit has been de­signed to make it as simple as possible to handle with maximum safety. The size of the plastic cover is: 117 x 161 x 65 mm.
1
2
3
C4C3EA
C
B
A
1 1
2
3
4
6
7
5
Care phone NOVO top view Care Phone NOVO bottom view
# Denomination
1 Speaker
2 Buttons
3 Front LEDs
Table 1. NOVO top view parts
# Denomination
1
Keyholes (for hanging up the unit) x 2
2
Connector well (under the connector lid)
3
Bottom cover screw
4
Power button
5
SIM card hatch*
6
Product label area
7
Microphone
Table 2. NOVO bottom view parts
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
9
2.2 Buttons
The NOVO unit has three distinct buttons located on the upper case.
B3B2
B1
Picture 1. Buttons on care phone NOVO
# Denomination Colour
B1 Alarm button Red
B2 Reset button Green
B3 Extra button Yellow
Table 3. NOVO unit buttons
2.2.1 Alarm button (B1)
A user alarm can be activated by pressing the red Alarm button (B1) on the main unit. This button is also used in Control Mode and Service Mode.
2.2.2 Reset button (B2)
Before making the alarm call NOVO is waiting a number of seconds enabling the user to reset the alarm. If the Reset button (B2) is pressed during this pe­riod, the alarm is interrupted. A number of tones (di-du-da) indicates this and the NOVO returns to idle mode.
This button is also used in Control Mode and Service Mode.
2.2.3 Extra button (B3)
The Extra button (B3) by default is to indicate Home/Away. For more information about Home/Away please refer to 4.1.2 Home/Away.
This button is also used in Control Mode, Service Mode and Daily Report.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
10
2.3 LEDs
The main unit has six (6) LEDs.
L3L2L1
L4
L5 L6
Picture 2. NOVO unit LEDs
# Colour Position (seen as above)
L1 Green Lemost LED in front
L2 Red Middle LED in front
L3 Yellow Rightmost LED in front
L4 Red Behind the Alarm button (B1)
L5 Green Behind the Reset button (B2)
L6 Yellow Behind the Extra button (B3)
Table 4. NOVO unit LEDs
The LED indications are described in chapter 3 Indications
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
11
2.4 Connectors on NOVO IP/GSM and NOVO PSTN/GSM
Picture 3. NOVO IP/GSM with connector lid removed Picture 4. NOVO IP/GSM with accumulator lid removed
The connectors are located in a well under the connector lid in the bottom of the speaker. Access the well by removing the connector lid.
Connector# Denomination Type
C1 IP RJ 45 (Ethernet)
C2 AC Micro-USB
EA External antenna SMA Connector (female)
Table 5. NOVO IP/GSM connectors denominations and physical characteristics
2.4.1 IP connector (C1)
The IP connector (C1) is a RJ45 (Ethernet) female connector and used for IP trac over cable.
2.4.2 AC connector (C2)
The AC adaptor conforms to the European directive EuP II. Connect the adaptor to the outlet marked AC in the bottom well of the NOVO, see 2.4 Connectors on NOVO IP/GSM and NOVO PSTN/GSM.
Only use the AC adaptor for your market. Please refer to Appendix C Recom­mended AC adaptors and accumulators .
2.5 External GSM antenna (EA)
See 2.6.5 External antenna.
C4C3EA
C
B
A
C2
C1
C4C3EA
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
12
2.6 Connectors on NOVO PSTN/GSM and PSTN
Picture 5. NOVO PSTN/GSM with connector lid
removed
Picture 6. NOVO PSTN/GSM with accumulator lid removed
The connectors are located in a well under the connector lid in the bottom of the speaker. Access the well by removing the connector lid.
Connector# Denomination Type
C1 TELE RJ11 (4/6) C2 LINE RJ11 (4/6) C3 AC Micro-USB
EA External antenna SMA Connector (female)
Table 6. NOVO PSTN/GSM connectors denominations and physical characteristics
2.6.1 TELE connector (C1)
The TELE connector (C1) is a RJ11 female connector and used for PSTN trac.
2.6.2 LINE connectorLINE (C2)
The TELE connector (C1) is a RJ11 female connector and used for PSTN trac.
2.6.3 AC connector (C3)
The AC adaptor conforms to the European directive EuP II. Connect the adaptor to the outlet marked AC in the bottom well of the NOVO, see 2.4 Connectors on NOVO IP/GSM and NOVO PSTN/GSM.
Only use the AC adaptor for your market. Please refer to Appendix C Recom­mended AC adaptors and accumulators .
2.6.4 External GSM antenna (EA)
See next section, 2.6.4.
C4C3EA
C
B
A
C3C2C1
C4EA
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
13
2.6.5 External antenna
Applies only to NOVO IP/GSM and NOVO PSTN/GSM.
NOVO supports the use of an external antenna and the use of the internal or external antenna is determined by a conguration parameter in the unit’s soware. The external antenna is intended to be used in case of poor GSM network signal quality.
The antenna can be placed in indoor or outdoor environment. Mount the antenna with the tape and/or the screws in the package. Place the antenna where the optimal signal strength can be achieved given the location for the installation.
Connecting the external antenna
1. If an external antenna is to be used the plastic flange (marked in red in the
illustration below) must be removed from the bottom cover.
Picture 7. Remove the plastic flange if an external antenna is to be used
2. Locate the SMA contact (EA).
C4C3EA
Picture 8. SMA connector (EA).
3. Remove the power and network cable.
4. Turn o the unit with the On/O button if it is turned onRemove the accu­mulator lid by unscrewing the screw just below the connector lid.
5. Gently screw the antenna connector clock wise onto the SMA contact(EA).
6. Place the cable between the small plastic “heels” to lead the antenna out of the cover.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
14
7. Ret the bottom cover.
8. Ret the AC and eventually IP cable and start up the unit.
9. Activate the external antenna in the Service Menu, see 6.3.4 Set external GSM antenna to On/O.
10. Test the GSM network signal, see 6.3.2 Radio/GSM coverage mode.
2.7 On/O button (PS1)
C4C3EA
C
B
A
PS1
Picture 9. On/O button location
The On/Off button (PS1) is not connected in series with the power source. This means that the processor (CPU) can control when the unit shall be powered on and o. The CPU can for instance shut o the unit to save the backup accumu­lator and can also override the switch so that the end user cannot turn o the unit.
Please note that it isn’t enough to disconnect the AC plug to shut o the unit, since the unit then uses the backup accumulator as power source.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
15
2.8 Accumulator lid
C4C3EA
C
B
A
1 1
2
3
4
6
7
5
Picture 10. Accumulator lid screw (#3)
EA
C
B
A
Picture 11. Accumulator compartment
The pictures above displays the internal accumulator compartments for the standard and large accumulator as well as the accumulator connector.
# Denomination
A Standard capacity accumulator compartment
B Large capacity accumulator compartment
C Accumulator connector
Table 7. Accumulator compartment denominations
The accumulator lid is opened by removing the cover screw (number 3 in the le picture above). Under the lid is the accumulator compartment for the backup accumulators. If an accumulator must be replaced, please note that the accumulator must to be of correct type and delivered from NEAT.
Always disconnect the AC adaptor and if connected the Ethernet cable before opening the accumulator lid.
Accumulator replacement should only be performed by trained personnel. NOVO can be equipped with either of two accumulator types:
• the standard accumulator with 400 mAh capacity.
• a large capacity accumulator with 2000 mAh capacity.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
16
Below are schematic illustrations of the accumulators.
Picture 12. Standard NOVO accumulator Picture 13. NOVO large capacity accumulator
2.8.1 Replacing the accumulator
1. Power o the unit and remove the power and network cable.
2. Remove the bottom plate by unscrewing the screw below the connector lid.
3. Detach the connector from the socket and remove the old accumulator.
4. Ret a new accumulator and attach the connector to the socket .
5. Ret the accumulator lid and connectors.
2.9 Mounting the SIM card
Applies only to NOVO IP/GSM and NOVO PSTN/GSM.
C4C3EA
C
B
A
H1
Picture 14. SIM Hatch (H1) location
Depending on model the SIM-hatch is made of either rubber (so) or plastic (hard). SIM cards should only be changed by the customer on NOVO products with the rubber hatch. To change SIM card on a NOVO product with the plastic hatch send the unit to service.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
17
Picture 15. Insert SIM card into SIM card slot
1. Power o the unit.
2. Open the SIM card hatch cover (H1). Note that the hatch should not be entirely removed.
3. Insert the SIM card according to the sketch in the bottom label.
4. Ret the SIM card hatch cover (H1).
5. Power on the unit. A reboot is required for the GSM-module to initialize properly aer inserting the SIM-card.
2.10 Mounting the NOVO
2.10.1 Key holes
There are two key holes for wall mounting the unit. The holes are designed to be used together with screws with a head diameter of 7-8 mm. The screw head should be approximately 4 mm out of the wall for best t.
A drawing and measures is found in Appendix A NOVO IP/GSM Mounting holes.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
18
3 Indications
3.1 Visual indications
3.1.1 Front LEDs
Normally the LEDs (L1-L3) at the front are o. When an error occurs, the corre­sponding LED will be lit up. The signication of the LEDs are described on the bottom label on the unit.
When the unit is in accumulator operation, the LEDs flashes instead of being continuously lit. See the tables below for all indications.
3.1.1.1 LED indications for NOVO IP/GSM and NOVO PSTN/GSM
L1 (Network) L2 (AC) L3 (Accumulator)
Normal mode, no failures O O O Network failure (IP/GSM/LINE) On O O AC failure O 0.5s On/4.5s O O Accumulator failure O O On Network and AC failure 0.5s On/4.5s O 0.5s On/4.5s O O Network and accumulator
failure
On O On
AC and accumulator failure O 0.5s On/4.5s O 0.5s On/4.5s O Network, AC and accumulator
failure
0.5s On/4.5s O 0.5s On/4.5s O 0.5s On/4.5s O
Radio interference 0.5s On/0.5s O 0.5s On/0.5s O 0.5s On/0.5s O SIM card failure 0.5s On/0.5s O O O AC and SIM card failure 0.5s On/4.5s O 0.5s On/4.5s O O
Table 8. Front LED (L1 - L3 ) indications
Downloading soware from the internet is indicated by blinking (1s) the Reset button LED (L5) every 20 seconds.
Firmware uppgrade indication
Aer the rmware is downloaded the unit automatically re-boots. During rm­ware upgrade, L1, L2 and L3 all flashes with the cadence 100ms on/100ms o.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
19
3.1.1.2 LED indications for NOVO PSTN
The table below applies to NOVO PSTN
L1 (LINE ) L2 (AC) L3 (Accumulator)
Normal mode, no failures O O O Line failure On O O AC failure O 0.5s On/4.5s O O Accumulator failure O O On Line and AC failure 0.5s On/4.5s O 0.5s On/4.5s O O Line and accumulator failure On O On AC and accumulator failure O 0.5s On/4.5s O 0.5s On/4.5s O Line, AC and accumulator
failure
0.5s On/4.5s O 0.5s On/4.5s O 0.5s On/4.5s O
Radio interference 0.5s On/0.5s O 0.5s On/0.5s O 0.5s On/0.5s O
AC failure 0.5s On/4.5s O 0.5s On/4.5s O O
Table 9. Front LED (L1 - L3 ) indications
3.1.2 Alarm button (L4) LED indications
The following indications will normally be in eect on the Alarm button led (L4).
AC Mode Accumulator Mode
Normal operation On* O Call in progress/Conversation 0.5s On/0.5s O 0.5s On/0.5s O Wait between calls 1.0s On/1.0s O 1.0s On/1.0s O No more call attempts** 2.5s On/2.5s O O
Table 10. Alarm button (L4) indications
* May be changed to Off by conguration, see below. ** “No more call attempts” means that the NOVO has tried to call the alarm receiver, but all call attempts
has failed. It has not been possible to transfer the alarm”.
3.1.3 Reset button LED (L5) indications
L5 is specically used for:
AC Mode Accumulator Mode
Firmware download 0.5s On/0.5s O 0.5s On/0.5s O
Passive notifcation 0.5s On/0.5s O 0.5s On/0.5s O
Table 11. Reset button LED (L5) indications
3.1.4 Extra button LED (L6) indications
L6 is specically used for:
AC Mode Accumulator Mode
Away mode On 0.5s On/4.5s O
Home mode O O
Table 12. Extra button LED (L6) indications
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
20
3.1.5 Control mode LED indications
When the unit enters Control Mode LEDs 1-3 are o and LEDs L4-L6 are lit.
3.1.6 Service mode LED indications
When the unit enters Service Mode L4 is on and L6 flashes (0.5s On/0.5s O).
3.1.7 Unit boot/startup
During boot/startup the visual indications are in two (2) steps:
6. The boot is indicated by LEDs L1-L3 as “running lights”, i.e. the LEDs are lit and closed in sequence starting with L1, then L2 and L3 and then restarts at L1. Normally this is a very quick sequence and should nish within 3 seconds.
7. The next step is startup and now all LEDs are lit and stay lit during the step. This normally takes 1-3 seconds where aer the LEDs are all o except L4 which is lit (default).
If everything is ne and no errors occurs the all LEDs should stay o. If there are any errors or alarm events the LEDs indicates this according to “3.1.1 Front LEDs”.
3.2 Acoustic indications
NOVO has the ability to play pre-recorded sounds, i.e. voice messages for improved interaction with the user.
3.2.1 Aer activating an alarm
When the NOVO is calling, by default it plays a melody as a pre-call melody. This is congurable.
3.2.2 Disconnection signal
Call disconnection is indicated by a tri-sound (di-du-da) in the loudspeaker. This signal is congurable.
3.2.3 Warning functions in Idle mode
If an AC, accumulator or line failure occurs an acoustical warning sound fol­lowed by a speech message is played in the speaker.
The indication is a short beep every 2 seconds for the rst 60 seconds and then a short beep every 30 seconds. The acoustical indication can be muted by pressing the Reset button (B2), but the visual indication continues.
If a new failure occurs, the acoustical indication is reset to start with a short beep every 2 seconds etc. regardless if the rst failure is attended or not.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
21
4 Alarm functions
4.1 User initiated alarms
These are the alarms initiated by the user, e.g. by pressing the Alarm button (B1) on the NOVO or on the portable trigger SMILE. It can also be when an accessory like WALL, PIR or a SMOKE is activated.
Depending on the alarm type received the alarms will be handled dierently by NOVO.
4.1.1 Passive alarm
A Passive alarm will be generated if an alarm event hasn’t occurred during a certain time. E.g. if an infrared detector is connected to NOVO as a Passive alarm the unit will not send any alarm as long as the infrared detector detects movements. If there is no activity for a certain time, e.g. 8 hours, then NOVO sends an alarm.
The Passive alarm timer starts when an alarm event has occurred that is connected to the Passive alarm. This can be:
• A radio signal from e.g. PIR or INKA
• A push on the Reset button (B2)
Please note that the timer doesn’t start until the alarm event has occurred the rst time.
If the Extra button (B3) is congured to Passive alarm a warning signal will be generated 60 seconds before the Passive alarm is sent. If any button or trans­mitter is activated during this period, the passive timer will be reset and no alarm is sent. If no activation occurs a Passive alarm will be sent to the alarm central.
4.1.2 Home/Away
Home/Away is a function for the user to communicate to the alarm central that “I will leave the premises for a while”, thus temporarily disabling passive functions and also the Radio transmitter surveillance.
In Away mode the follwing is valid:
• The passive function is paused (the timer does not run)
• The radio supervision is paused for portable alarm transmitters (such as the pendant – SMILE/ATOM)
• Indication of Away mode (L6)
• A radio message with alarm type User alarm from trigger or User alarm
from button will result in both user alarm and a Home indication alarm and
change from Away mode back to Home mode.
• Pressing button Extra Buttom (B3) will result in a Home indication alarm and change from away mode back to home mode.
When returning from Away mode to Home mode
• The passive function is resumed (timers are reloaded to initial value)
• Radio supervision is resumed (timers are reloaded with initial value)
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
22
4.1.3 Presence/Ready
The Presence mode is intended to determine when personnel is present in the user’s home.
The mode can be changed either from radio messages or buttons. If the alarm type is active an indication is sent according to the congured call sequence.
In Presence mode the following is valid:
• A radio message containing alarm types User alarm from trigger or User
alarm from button instead results in an Assistance alarm if this is activated.
• When the time in Presence mode exceeds the parameter Max time in Pres-
ence mode the unit automatically resumes Ready mode.
• L1, L2 and L3 will flash 0.5 s every 4 seconds. If another indication is active the LED state is inverted during the flash, i.e. o during 0.5 s instead of on.
4.2 Technical Alarms
For digitally connected units technical alarms can be congured to auto­matically send this alarms to NEAT Carephone Management Portal (CMP) for continous connectivity and functionality supervision. The descriptions of the technical alarms in the sections below are valid for alarms sent to an alarm receiver (not the CMP).
4.2.1 Radio transmitter surveillance
The care phone can handle a number of connected transmitters with radio test alarm activated. If there hasn’t been any radio test alarm for a certain period, NOVO can be congured to send a Radio out of range alarm to the central indicating that there is some trouble with the transmitter. NOVO can also send a Radio within range indication when the transmitter is working again.
4.3 Accumulator alarm
If the backup accumulator voltage level in the care phone too low an Accu-
mulator alarm is sent to alert the maintenance personnel. The reason for the
alarm can be:
• The AC adaptor isn’t connected and/or malfunctioning and NOVO has been accumulator powered for a long time.
• There is a mains failure and the unit is powered by the backup accumulator.
• The accumulator is getting worn out.
The unit checks the accumulator status at regular intervals. When the AC adaptor is connected the default is one check every 24 hours (congurable). If the unit is powered from the accumulator the status is checked every minute.
Should the voltage level fall below the threshold value an Accumulator alarm is sent. The user is also warned by L3 on the front of the unit and by an acous­tic signal. To mute the acoustical warning, see 3.2.3 Warning functions in Idle mode
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
23
4.4 Automatic test alarm
To let the alarm receiver know that the care phone is working, NOVO can send test alarms to the alarm receiver at regular intervals. The default value is one test alarm each 24 hours. This interval can be changed and the function can also be turned o.
The rst test alarm will be sent aer a random time between 5 and 60 minutes aer installation. The second test alarm will be sent aer a random period between 1 minute and the number of hours given by the time interval.
4.5 Battery alarm
If the battery voltage level in SMILE or other connected battery powered radio equipment is getting low the unit sends an alarm by radio to NOVO which then immediately sends a Battery alarm to alert the maintenance personnell that the unit needs to be replaced.
4.6 Radio interference
If a continuous radio interference signal is detected for more than 30 seconds the unit indicates this by flashing all warning LEDs, see 3.1.1 Front LEDs and sends a Radio interference alarm to the alarm receiver.
4.7 Mains failure
When the unit detects a mains failure, the unit will be powered from the inter­nal backup-accumulator. The user will be warned by L2 on the front of the unit and by an acoustic signal, to deactivate this warning signal, see 3.2.3 Warn­ing functions in Idle mode.
At mains failure, the unit sends a Mains failure alarm aer a certain period. By default the alarm is sent one hour aer mains failure occurred.
To avoid that many units call at the same time, a random period of 5-60 minutes, will be added before the alarm is sent. If time to Mains failure alarm is set to one hour (default), the alarm will be sent aer 65 to 120 minutes aer the mains failure occurred.
4.8 Mains return
When the AC is returned and the care phone has sent a Mains failure alarm, NOVO can be congured to send a Mains OK indication. To avoid that many units call at the same time, the time from AC returns to the alarm is sent will be a random time between 5 and 30 minutes.
4.9 External alarms
External alarm can be sent from additional accessories, such as door/window sensors, motion detectors or smoke detectors.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
24
5 The alarm call
Anything that creates some kind of action in the NOVO is called an alarm event. An alarm event can be any of:
• pressing the Alarm button (B1)
• a mains failure
• radio interference
These alarm events can be user initiated or initiated by internal functions such as monitoring functions, timers or external alarm events.
The alarm event is associated with a certain alarm type and the alarm type is associated with an alarm group an the alarm group is associated with a sequence.
A sequence contains a number of steps where each step is an instruction what action to perform. It can be calling an alarm central with voice conversation or it can be a silent action, i.e. sending an alarm to the alarm central without voice conversation to inform that an alarm event has taken place, e.g. there has been a mains failure.
These steps forms a chain and when a sequence is initiated NOVO performs the action in the rst step and depending on the settings of the executed step it can either continue to the next step or stop the execution of the sequence.
5.1 Call routing
The reason for the alarm i.e. the alarm source, decides what alarm type that will be used in the alarm call. The alarm type forms a part of a group which points to a call sequence. The sequence consists of up to 10 steps with tele­phone number, protocol and number of call attempts.
Alarm type
Tele no.
AemptsProtocol
Group
Sequence
1 2 3
4
Alarm Event
Picture 16. General decription of the call structure
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
25
5.2 Alarm events
An alarm can be initiated by one of the following alarm events:
A radio signal from a radio transmitter, e.g. ATOM, SMILE, WALL or similar
• A push on any button
• An internally activated alarm
Depending on the alarm event, the alarm can be routed to dierent alarm receivers in sequence. The type of alarm event is called alarm type, see next section.
5.3 Alarm types
The alarm type describes the reason for the alarm. For each alarm type a num­ber of properties of the alarm call is decided in the conguration.
5.3.1 Radio equipment alarms
When an alarm arrives from a radio transmitter, the alarm type is normally decided from what alarm type that is connected to the corresponding radio position.
5.3.2 Alarms from Alarm button (B1) or Extra button (B3)
When the user presses the Alarm button (B1), the alarm type is always User alarm from button. The Extra button (B3) can be congured to send an option­al alarm type.
5.3.3 Internally activated alarms
The following alarms are activated internally:
• Reminder alarm
• Passive alarm
• Automatic ready indication
• Test alarm
• Mains failure alarm
• Mains OK indication
• Accumulator alarm
5.3.4 Undened alarm types
All alarm types are not dened in every protocol. If an alarm type isn’t dened the unit will try with the next position in the sequence to see if this position holds another protocol. This will be done immediately. The same thing hap­pens if a telephone number or alarm code is missing. In the Home Phone protocol, however, there is no requirement for any alarm code.
5.4 Alarm type groups
NOVO supports 16 alarm type groups, numbered from 1-16 and every alarm type must belong to one of these groups.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
26
5.5 Alarm sequences
NOVO supports up to eight (8) sequences where each sequence can contain up to ten (10) steps. For each step in the sequence the following parameters can be congured:
• Call type
• Carrier type
• Call attempts
• Continue eer success
5.5.1 Call type
NOVO supports up to twelve (12) call types, named A to L. Every call type con­tains the following parameters:
• Telephone number/address
• Protocol
• Port
• Username
• Password
• Optional voice number
5.5.2 Carrier type
Depending on version NOVO supports up to two carriers:
Version IP GSM PSTN
NOVO IP/GSM X X
NOVO PSTN/GSM X X
NOVO PSTN X
Table 13. Version carriers
Normally a primary and a secondary carrier is set where the second carrier can be congured as fallback in the alarm event of communication error on the primary carrier.
5.5.3 Call attempts
If a call fails, the unit waits and then re-tries the number of times specied by the call attempt parameter in the current step of the alarm sequence. When the maximum number of call attempts is reached, the sequence continues to the next step. The time to wait between calls is specied by the parameter Wait between call attempts, see below. There is also a global parameter for the maximum total number of call attempts in one call sequence.
Wait between call attempts
If no-one answers the call, NOVO re-tries and between the call attempts there is a waiting period which can be set.
For some alarm types it is possible to interrupt the call during this waiting period by pressing the Reset button (B2). If a new alarm with higher priority arrives during this waiting time this will also interrupt the sequence and start a new alarm session.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
27
Continue aer success
Normal behavior is that the unit stops the call sequence when a call has been successful. However it is possible to set this parameter so the unit instead continues to the specied step in the alarm sequence aer the successful call. If the call attempt failed, the unit continues to the next step as normal.
5.5.4 Acknowledgement of the alarm call
The care phone requires that the receiving personnell in some way acknowl­edge that they have received the alarm call. The acknowledgment is usually a DTMF tone sent from the telephoneIn connection to this NOVO can also be congured to require that the alarm call is disconnected by the receiving per­sonnel.
5.5.5 Repetitions of the sequence
The call sequence can be congured to make several repetitions if there is no answer from the receiving part.
5.6 Alarm code
Each NOVO unit has a uniqe number ID which can contain up to 32 characters and is used to identify the caller in the alarm central.
5.7 Indications during an alarm call
NOVO has several ways to the progress and status of an alarm call. Below is a list of the default indications for a user initiated alarm call.
Please note that certain alarm types, e.g. mains failure or radio inteference, by default are “silent” i.e. they do not play the pre-call signal, dial tones or the disconnection sound when done etc..
Pre-call signal
Aer a user initiated alarm e.g. aer pushing the Alarm button (B1) NOVO plays a pre-call signal in the speaker to alert the user that the alarm is be­ing initiated. During the pre-call signal it is possible to cancel the alarm call attempt by pressing the Reset button (B2). NOVO conrms the cancellation by playing a sound and the unit resumes Idle mode.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
28
Dial tones in speaker
Aer the pre-call signal the unit starts dialling and the dial tones are played in the speaker.
Alarm LED blinks during call attempt
During the alarm call attempt (and before the alarm central answers) the
Alarm button LED (L3) blinks (0.5s On/0.5s O) to indicate that an alarm call
is in progress.
Call answered
When the alarm call is answered by the alarm central receiver NOVO initiates a data transmission sequence before the alarm central operator’s voice is heard. The data transmission is silent to the caller.
Failed call
If the call attempt somehow fails, e.g. the alarm central does not answer in a timely fashion or the call is unintentionally cut before the alarm central sends a disconnection command to NOVO the unit indicates this by blinking the
Alarm button LED (L3) 1s On/1s O. Depending on the settings in the Alarm
sequence new call attempt may occur.
Disconnection sound at end of successful call
Aer a successful alarm call to the alarm central NOVO disconnects and plays a disconnection signal in the speaker to indicate that the call is now terminat­ed.
Failed alarm, sound/blink
If the alarm central answers the call but somehow fails to acknowledge the alarm the unit returns to Idle mode but indicates a failed alarm by blinking the
Alarm button LED (L3) (2.5s On/2.5s O). Depending on the settings in the
Alarm sequence new call attempts may occur.
5.8 Protocols
NOVO supports most occuring protocols in the market. The protocol determines the parameters for the communication session and
consist of a data transmission part (i.e. alarm code, alarm type etc.) and the conversation (voice) part. For an analogue alarm receiver this is sent with DTMF tones and for an IP-based alarm receiver this is sent digitally.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
29
Home Phone
When the care phone is congured to call to a normal telephone, NOVO must use the Home Phone protocol. To control the conversation in Home Phone protocol, the alarm receiving party can press the buttons on their telephone according to below.
Command Meaning
1
Increase conversation volume
2
Go into duplex mode
3
Decrase conversation volume
4
Send Phone ID
7
Go into simplex mode, activate the microphone
8
Go into simplex mode, activate the speaker
0 or 6
Disconnect the call
9
Deny call, Go to Next
Table 14. Home Phone protocol conversation control commands
5.9 Conversation
To ensure the care phone doesn’t stay in conversation mode forever there is a maximum time for the conversation, normally set to 5 minutes (congurable). If a tone command is sent from the receiving party the timer is reset and the conversation can continue another 5 minutes (default).
20 seconds before end of conversation time the care phone sends a warning tone to the receiving party and the operator/personnell can then press a but­ton to extend the conversation time.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
30
5.10 Examples
5.10.1 Example 1 - a simple alarm sequence
The user presses the alarm button on the portable trigger, e.g. SMILE. This triggers an alarm event in NOVO and the logic nds that this is alarm event is associated to the alarm type User alarm from trigger. This alarm type belongs to an alarm type group associated to sequence #1. In this case sequence #1 consists of 1 step. This step consist of some parameters:
Step Call type Carrier type Call attempts
1 A GSM 2
Table 15. Example of steps in a sequence
Let’s take a look at step 1. The Call type (A) is built up by a set of parameters, see the table below.
The number of Call attempts (2) decides how many times step 1 will be re­peated in the alarm event of a failed call attempt. Each repetition is performed aer a given time and is congurable.
The Call types consist of call specic parameters and depening on the proto­col dierent information is required.
Call type
Address/phone number Protocol Port Username Password Optional voice
number
A www.alarm.com SCAIP 555 username password N/A
B www.alarm.com SCAIP 555 username password N/A
Table 16. Example of call type parameters
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
31
5.10.2 Example 2 - SCAIP over IP/GSM
Calling a digital alarm reciver requires some additional connection parame­ters since NOVO communicates with the alarm central like a computer, i.e. it is required to set an IP address (e.g. 192.168.1.10) or a DNS hostname (e.g. www.alarm.com) and a communications port and in some cases login creden­tials.
Step Call type Carrier type Call attempts
1 A IP 2
2 B GSM 2
Table 17. Example of steps in a sequence
In this example NOVO attempts to call the alarm receiver over IP and GSM.
Call type
Address/phone number Protocol Port Username Password Optional voice
number
A www.alarm.com SCAIP 555 username password N/A
B www.alarm.com SCAIP 555 username password N/A
Table 18. Example of call type parameters
5.10.3 Example 3 - NEAT Talk/CPC to an analogue alarm receiver
When calling an analogue alarm receiver the protocol used must correspond to the alarm receiver and the carrier must be either IP or GSM.
If carrier type is IP the corresponding SIP account settings must be set.
Below is an example of the sequence steps and call type parameters.
Step Call type Carrier type Call attempts
1 B IP 3
2 C GSM 2
Table 19. Example of steps in a sequence
Call type
Address/phone number Protocol Port Username Password Optional voice
number
B +4646112157 CPC 5060 username password N/A
C +4646112157
NEAT Talk
45005 username password N/A
Table 20. Example of call type parameters
In the example above there are two steps with two call types, each step is designated a carrier (IP and GSM) and step #1 makes three call attempts and if these call attempts fails NOVO continues to step #2 and make two attempts.
The call types are dened with the phone numbers and protocol.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
32
5.10.4 Example 4 - Using Home Phone protocol
When using the Home Phone protocol the carrier must be either IP or GSM and the call type must include an analogue number.
Step Call type Carrier type Call attempts
1 C GSM 3
Table 21. Example of steps in a sequence using Home Phone protocol
In the example there is one step in the sequence, the carrier is set to GSM and there will be 3 call attemps. The call type (set to C in the example) calls the phone number +4646112165 and no other parameters are required.
Call type
Address/phone number
Protocol Port Username Password Optional voice
number
C +4646112157
Homephone
N/A N/A N/A N/A
Table 22. Example of call type parameters when using the Home Phone protocol
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
33
6 Programming/conguration modes
6.1 General
Depending on version conguration can be done by the unit buttons, via the NEAT Management Portal (CMP), with a soware programmer, a HAND termi­nal or with the LPP protocol.
Version Buttons Soware CMP HAND LPP
NOVO IP/GSM X X X
NOVO PSTN/GSM X X X X X
NOVO PSTN X X X X
Table 23. Version programming options
NOVO is normally in Idle Mode, i.e. is not processing any user-ini tiated (e.g. user alarm) nor automatic alarm event/action (e.g. test alarm).
Control Mode and Service Menu are ways of easily conguring the unit. The diagram below displayes the tree structure of the menues and its commands.
Toggle Alarm button
(B1) illumination
Change volume
(conversation/signal)
Enter Service Menu
Add a transmitter
Radio coverage test
Erase a transmitter
Toggle external
antenna On/O
Toggle Home/Away/-
Passive status
Control Mode Menu Service Mode Menu
Picture 17. Control Mode and Service Mode tree structure
In NOVO PSTN the menu item Toggle external antenna is not enabled and the menu item Radio coverage Test is replaced by Walk test mode.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
34
6.2 Control mode (CM)
Enter CM (Control Mode) by shortly pressing button PS1 when unit is in Idle mode. When the unit is in CM all LEDs L4-6 are lit. The unit returns automati­cally to Idle Mode aer function execution or 5 seconds of inactivity.
# Control Mode functions
1 Toggle Alarm button (B1) illumination
2 Change volume (conversation/signal)
3 Enter Service Menu
Table 24. Control Mode functions
6.2.1 Toggle Alarm button (B1) illumination
Press and hold Alarm button (B1) for more than 3 seconds to toggle Alarm
button (B1) illumination. The new status is played in the speaker.
6.2.2 Change volume
Press and hold Reset button (B2) for more than 3 seconds to toggle conver­sation level. The level is indicated by one, two or three “blipps” and in the relevant level in the speaker. Release Reset button (B2) at desired level is and press again (and hold) within 5 seconds to toggle signal level. Aer each selection the unit “blipps” to conrm.
6.2.3 Enter Service Mode
Press Extra button (B3) for more than 3 seconds to enter Service Mode.
6.3 Service Mode (SM)
Enter Control Mode (see above) and then press button Extra button (B3) for more than 3 seconds. When the unit enters Service Mode the Alarm button
LED (L1) is lit and Extra buttion LED (L3) blinks and the voice message for
adding a transmitter (function #1) is played in the speaker. Select the func­tion by pressing Alarm button (B1) or step to next function by pressing Extra
button (B3). To indicate the current function available a corresponing voice
message is played in the speaker. Aer nishing conguration of a selected function NOVO automatically re-
turns back to the Service Menu. Step to next function by pressing Extra button
(B3) or exit by pressing Reset Button (B2).
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
35
The table below list the functions in the Service Mode menu.
Service Mode functions
# NOVO IP/GSM and NOVO PSTN/GSM NOVO PSTN
1 Add transmitter Add transmitter
2 Radio/GSM coverage mode Walk test mode
3 Remove transmitter Remove transmitter
4 Set external GSM antenna to On/O Change Home/Away/Passive status
5 Change Home/Away/Passive status N/A
Table 25. Service Mode functions
6.3.1 Add a transmitter
NOVO features Plug&Play programming of radio peripherals as well as tra­ditional position programming for older radio peripherals not suppor ting Plug&Play.
In total 48 radio peripherals can be added to NOVO. 8 as traditional position programed devices and 40 as Plug&Play peripherals.
NOVO supports a large number of the alarm types for traditional position pro­gramming and in the default conguration the alarm types are positioned as listed in the table below.
Position Denomination
1 User alarm from trigger
2 User alarm from trigger
3 User alarm from trigger
4 Smoke
5 Fall alarm
6 Door alarm
7 Bed alarm
8 Passive alarm
Table 26. The most common alarm types and their positions (default)
Please note that the table above is a default conguration. Other congura­tions may apply to your unit.
To add a peripheral, go to Add transmitter in the service menu and enter the function by pressing Alarm button (B1). NOVO is now open for programming a Plug&Play radio peripheral by just activating the peripheral (e.g. pressing the Alarm button on SMILE). A short beep conrms the addition of the peripheral.
If the device is not a Plug&Play device, press the Extra button (B3) to enter the rst of the eight position indicated with one short “beep”, press the Extra
button (B3) again to step to position 2, now indicated with two short “beeps”
etc. At desired position, press the Alarm button (B1) to enter the position and
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
36
add the transmitter by activating the unit. A short beep conrms the addition and the beep also communicates the transmitter battery status. The beeps means the following:
• One short beep — action OK and transmitter battery OK
• One long beep — action OK and transmitter battery low
• An error sound — the transmitter is already present at another radio posi­tion or it does not support Plug&Play if the error sound appears while trying to add the device as a Plug&Play device.
Exit function by pressing Reset Button (B2).
6.3.2 Radio/GSM coverage mode
This is only valid for NOVO IP/GSM and NOVO PSTN/GSM.
The Radio/GSM coverage mode uses the LEDs to display the radio/GSM signal strength and is updated every 2 seconds. L4 and L6 are lit alternately to L5, i.e. when L4 and L6 are lit, L5 is o.
Signal L1 L2 L3 L4 L5 L6
Very weak (1) Flash O O Flash Flash Flash
Weak (2) On O O Flash Flash Flash
Average - (3) On Flash O Flash Flash Flash
Average + (4) On On O Flash Flash Flash
Strong (5) On On Flash Flash Flash Flash
Very strong (6) On On On Flash Flash Flash
GSM not installed Flash Flash Flash Flash Flash Flash
GSM not active O O O Flash Flash Flash
Table 27. LED indications when in Radio/GSM coverage test
In Radio/GSM coverage mode (it’s also possible to test the radio connection between a connected transmitter and the NOVO-unit, i.e. Walk test mode.
If Radio/GSM coverage test is initiated directly aer startup, the test indicates “GSM not installed” until the GSM module is initiated and running.
End the Radio/GSM coverage test by pressing Reset Button (B2).
Walk test mode
When in Radio/GSM coverage, activate the connected transmitter, (e.g press­ing the Alarm button on SMILE) and NOVO responds with a “blipp” if the radio coverage is OK. On SMILE the LED blinks green to acknowledge radio coverage is OK.
6.3.3 Remove transmitter
It is possible to remove one or all radio peripherals regardless of whether it is a Plug&Play or position programed peripheral.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
37
Remove a known and working peripheral
Enter Remove transmitter from the service menu by pressing the Alarm button
(B1). Activate the peripheral and press the Alarm button (B1) until time out.
The transmitter is now removed from the NOVO conguration.
Remove a peripheral at a specic position
Enter remove transmitter from the service menu by pressing the Alarm but-
ton (B1). Press the Extra button (B3) to enter the rst of the eight position
indicated with one short “beep”. Press the Extra button (B3) again to step to position 2, now indicated with two short “beeps” etc. At the desired position, press the Alarm button (B1) to timeout in order to remove the transmitter at the position.
Remove all peripherals
Enter “Remove transmitter” from the service menu by pressing the Alarm
button (B1). Press and hold the Alarm button (B1) until the general beep is
played. Release and then press and hold the Alarm button (B1) again until the conrmation beep is played. All radio peripherals are now erased.
Exit to SM by pressing Reset Button (B2).
The only way to remove a broken Plug&Play device from the NOVO congu­ration is to erase all transmitters or perform the action via the NEAT Manage­ment Portal or with a soware programmer. When a full removal is performed, don’t forget to re-add the user peripherals in the installation.
6.3.4 Set external GSM antenna to On/O
Not applicable to NOVO PSTN.
External antenna status is played in speaker. Change status by pressing
Alarm button (B1) > 3 seconds. The new status is played in speaker and NOVO
automatically returns to SM.
6.3.5 Change Home/Away/Passive On/o
Change status by pressing Alarm button (B1) > 3 seconds.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
38
6.4 Programing NOVO PSTN units with LPP commands
NOVO units with PSTN functionality can be programmed with the Local Pro­gramming Protocol (LPP). This protocol uses DTMF dialtones, i.e. the same dial tones that are used in a regular, analogue telephone and programming can de done over the PSTN line (e.g. from a cellular phone) or with a HAND unit.
For more information about HAND please refer to HAND User Manual, NE41 07001-02.
The parameters available for programming with LPP are:
Parameter DTMF Command HAND Command
Telephone no A
00#NNN#
[Tel A] NNN [OK]
Telephone no B
01#NNN#
[Tel B] NNN [OK]
Alarm code
15#NNN#
[CODE] NN [OK]
Protocol
45#NNN#
[PROT] NN [OK]
Set time
84#HHMM#
84 [OK] HHMM [OK]
Exit programming
90##
[END]
Table 28. LPP programming parameters
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
39
7 NOVO Programmer
7.1 Installation
NOVO can be congured via our soware NOVO Programmer. This soware can be obtained from your reseller or distributor.
NOVO Programmer is tested to work with Microso Windows versions:
• Windows 7
• Windows 8
• Windows 8.1
• Windows 10
Install the NOVO Programmer as a local computer administrator.
When NOVO Programmer is started a dialog window asks for a password, Press “Enter” to bypass the password and start NOVO Programmer in “Basic” mode.
For further functionality your reseller or distributor can provide you with a password for extended functionality in NOVO Programmer.
7.2 Menues
7.2.1 File menu
“New”, “Open”, Save” “Save as...” is used for handling the conguration les.
7.2.2 Communication menu
“Read from unit (CTRL+R)” reads the current conguration from the connected NOVO into NOVO Programmer and “Write to unit (CRTL+W)” writes the current conguration in NOVO Programmer into the connected NOVO.
Aer the conguration le is written to NOVO the unit is disconnected from an re-connected to Windows. Depending on your Windows system settings the “Auto play” dialog window may open. This dialog window can safely be closed.
7.2.3 Option menu
Select languague
Select the user interface languague from the list. The languague change is implemented instantaneoulsy.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
40
Properties
This window displays the paths to the log and languague les. These paths are read only! The path to the conguration les is editable by clicking the button “Browse” and selecting the new path where saved conguration les will be stored.
Password
To enter extended functionality enter the password and click OK. Open an existing or create a new conguration le to access the extended functions.
7.2.4 Help menu
The “About” dialog window displays some general info about the NOVO pro­grammer, contact information and the possibility to send a mail to NEAT.
7.3 NOVO Programmer Tabs
7.3.1 Basic
Alarm code
Enter the user’s alarm code.
PIN code for SIM card
If the SIM card requires a PIN code, enter the four digits here otherwise leave empty.
If the SIM cards is blocked by too many erroneous attempts it must be removed from NOVO and inserted into a regular mobile phone to unlock it with a PUK code.
Own number
If the conguration parameters require the subscription phone number enter it here.
Own number from SIM card
Depending on the GSM network operator the phone number can be stored and read from the SIM card. If this is the case, the phone number will be dis­played here.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
41
8 Misc
8.1 Real Time Clock (RTC)
NOVO is equipped with a real time clock (RTC) which is running continously, even when power is turned o and/or running on accumulator.
The RTC can be set by NTP servers (if connected to internet via GSM/GPRS). NOVO supports Daylight Savings Time and this is congurable.
8.2 Alarm log
The last alarms are logged and synhcronized to CMP. To view the alarm log, access CMP or contact your distributor. The data stored in this log is:
• Time when the alarm was added to the alarm queue
• Alarm type
• Result (whether the alarm was succesful or not)
• Last call duration
• Last call result, see the table below
Result Meaning
Success OK
Failed No contact aer all call attempts performed
Not nalized Call sequence not completed due to unknown error
Queue full Alarm queue was full
Not active Alarm type was not active
Cancelled The user cancelled the alarm
Table 29. Alarm log results
Aer a manual restart (done with the I/O button) all alarms in the alarm log with result “Not nalized” are automatically changed to “Cancelled”.
All other restarts (e.g. aer a rmware upgrade or aer a power failure) re­sults in all alarms with status “Not nalized” are sent again.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
42
9 Important
9.1 Use and maintenance
• Do not damage the unit or its parts. If damaged, immidiately contact authorized personnel.
• Do not expose to direct sunlight.
• Keep away from dust, moist and dirt.
• Do not drop, knock, twist or shake the device.
• Do not warm up the device or use it near re.
9.2 Cleaning
• All parts in the NOVO kit can be cleaned with a mild soap solution and a damp cloth. Dry with a dry cloth.
• Strong chemicals, grease and other harsh substances must not be used when cleaning or handling the parts in the NOVO kit.
• NOVO must be disconnected from the power socket before cleaning.
• Aer cleaning, control that the home care phone works properly by sending a test alarm to the alarm receiver/central.
9.3 Safety Notes
• Read instructions prior to use.
• Always test the system per instructions prior to use.
• Always check the function of the product aer making adjustments.
• This product may not be suitable for all persons and should not be a substitute for the routine visual monitoring protocol by caregiver.
• Must not be used in situations where a delay in the arrival of appropriate medical care, could lead to a potentially life-threatening situation.
• Our units are NOT intended for any life support device, thus intending a device whose malfunction may result in damage to a life.
• Check the device regularly and replace when necessary.
• Do not integrate with other systems other than those specied in this docu­ment.
• Always keep the device dry. Exposure to excessive moist can cause malfunc­tion.
• The product will not cause electromagnetic disturbances under normal working conditions.
• The product can be placed near other products or devices as long as mechanical vibration is not present.
• Remove batteries if the unit is to be out of use or stored for an extended period of time.
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
43
9.4 Disposal
At the end of the product’s use life, please dispose of it at appropriate col­lection points provided in your country. For disposal or recycling information, please contact your local authorities or the Electronic Industries Alliance (EIA, www.eiae.org). In the European Union, the bin label indicates that this prod­uct should not be disposed of with household waste. It should be deposited at an appropriate facility to enable recovery and recycling or returned to your distributor.
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
44
Appendix A NOVO IP/GSM Mounng holes
Picture 18. NOVO unit key hole measures
68 mm
117 mm
161 mm
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
45
Appendix B Alarm types and Alarm type groups
Assistance alarms
Assistance alarm Enuresis
Assult alarms
Assault alarm Burglar alarm
Emergency alarms
Emergency alarm
External sensor alarms
Bed alarm
Carpet alarm Door alarm
Other alarms
Double press Long press Manoeuvre Measurement data Medical dispenser Position info Radio test alarm Reset alarm Tamper alarm Technical failure User call 1 User call 2 User dened
Presence alarms
Action indication Automatic ready
indication Log call Presence indication Ready indication Reminder alarm
Smoke detector alarms
Co Gas
Gas alarm Smoke detector
alarm Temperature alarm Water alarm
Technical alarms
Accumulator alarm Accumulator fully
charged Battery alarm Daily report / Event Heartbeat Mains failure alarm Mains OK indication
NE41 15013-02 v1.0
NOVO Technical Handbook
neat
46
Network return No network Radio interference Radio out of range Radio within range Service call
Test alarm
Test alarm
User alarms
Away indication Bogus call Epilepsy alarm Fall alarm (man
down) Home indication Inactivity Passive alarm Pull cord alarm User alarm from
button User alarm from trigger User alarm from trigger, battery low
NE41 15013-02 v1.0 NOVO Technical Handbook
neat
47
NOVO Unit
Measures, W x H x D 175 x 130 x 68 mm Temperature range +5 - +55 °C Weight (incl. backup
accumulator)
300 g (standard capacity accumulator) or 355 g (large capacity accumulator)
Communication IP/GSM (GPRS), PSTN/GSM (GPRS) or PSTN Power supply
230 VAC/5 V
DC
Max power consumption <5 W
Accumulator
Type NiMH Voltage
3.6 V
DC
Capacity 400 mAh or 2000mAH Stand-by backup time up to 450h
Speaker
Max power 2 W Impedance 8 ohm
Radio
Max transmission power 10mW Radio frequency 869.2125 MHz (Social alarms, transmission)
869.2375 MHz (Acknowledge) Security level Category 1 (Highest) Radio range Up to 300 meters, free air Approvals EN69050-1:2006+A1+A2+A11+A12:2011
EN 301489-1 v1.9.1 EN 301489-3 v1.6.1 EN 301489-7 v1.3.1 EN 300220-1 v2.4.1 EN 300220-2 v2.4.1 EN 301511 v9.0.2 CGF-CC v3.4.0 EN 50134-2 - Social alarms
SMILE
Measures, W x H x D 34 x 42 x 15 mm Weight (incl. backup
accumulator)
14 g
Radio frequency 869.2125 MHz (Social alarms, transmission)
869.2375 MHz (Acknowledge) IP Code IP67 Temperature range +5 - +55 °C
www.neat-group.com
Appendix C Recommended AC adaptors and accumulators
Recommended AC adaptors for user markets
EU NE31 07006-14
UK NE31 07006-16
US NE31 07006-21
Recommended accumulators
400 mAh NE31 14002-02
2000 mAh NE31 14004-03
Loading...