4 Alarm functions
4.1 User initiated alarms
These are the alarms initiated by the user, e.g. by pressing the Alarm button
(B1) on the NOVO or on the portable trigger SMILE. It can also be when an
accessory like WALL, PIR or a SMOKE is activated.
Depending on the alarm type received the alarms will be handled dierently
by NOVO.
4.1.1 Passive alarm
A Passive alarm will be generated if an alarm event hasn’t occurred during a
certain time. E.g. if an infrared detector is connected to NOVO as a Passive
alarm the unit will not send any alarm as long as the infrared detector detects
movements. If there is no activity for a certain time, e.g. 8 hours, then NOVO
sends an alarm.
The Passive alarm timer starts when an alarm event has occurred that is
connected to the Passive alarm. This can be:
• A radio signal from e.g. PIR or INKA
• A push on the Reset button (B2)
Please note that the timer doesn’t start until the alarm event has occurred the
rst time.
If the Extra button (B3) is congured to Passive alarm a warning signal will be
generated 60 seconds before the Passive alarm is sent. If any button or transmitter is activated during this period, the passive timer will be reset and no
alarm is sent. If no activation occurs a Passive alarm will be sent to the alarm
central.
4.1.2 Home/Away
Home/Away is a function for the user to communicate to the alarm central
that “I will leave the premises for a while”, thus temporarily disabling passive
functions and also the Radio transmitter surveillance.
In Away mode the follwing is valid:
• The passive function is paused (the timer does not run)
• The radio supervision is paused for portable alarm transmitters (such as the
pendant – SMILE/ATOM)
• Indication of Away mode (L6)
• A radio message with alarm type User alarm from trigger or User alarm
from button will result in both user alarm and a Home indication alarm and
change from Away mode back to Home mode.
• Pressing button Extra Buttom (B3) will result in a Home indication alarm
and change from away mode back to home mode.
When returning from Away mode to Home mode
• The passive function is resumed (timers are reloaded to initial value)
• Radio supervision is resumed (timers are reloaded with initial value)