NavCom SF-3050 User Manual

Applications Note – Logging Data to Internal Memory SurvCE - SF-3050
This guide will step you through logging GNSS receiver data to the SF-3050 internal memory port via Carlson Software’s SurvCE data collector program. The receiver data may be used for post-processing or troubleshooting.
SurvCE software version 2.30.47 (Beta release) or later is required for this interface The procedure which follows applies to version 2.0.22.0a or later of SF-3050 firmware
Procedure
Create a data logging command file. A sample
Data Logging Setup.txt: [OUTPUT]PANICA,ONCHANGE,,FH1 [OUTPUT]??,ONCHANGE,,FH1 [OUTPUT]OK,ONCHANGE,,FH1 [LOGFILE]A:,START [OUTPUT]MSGVERSION,ONTIME,600,FH1 [OUTPUT]MSGPRODUCTINFO,ONCE,,FH1 [OUTPUT]MSGPRODUCTINFO,ONTIME,600,FH1 [PROFILE]OUTPUT [OUTPUT]EPHEM1B,ONCE,,FH1 [OUTPUT]ALM1B,ONCE,,FH1 [OUTPUT]ECHODGPSB,ONCHANGE,,FH1 [OUTPUT]CHNLSTATUS1B,ONTIME,1,FH1 [OUTPUT]PVT1B,ONTIME,1,FH1 [OUTPUT]MEAS1B,ONTIME,1,FH1 [OUTPUT]EPHEM1B,ONCHANGE,,FH1 [OUTPUT]ALM1B,ONCHANGE,,FH1 [OUTPUT]SFSTATUS1B,ONTIME,1,FH1
Copy this file to the data collector Connect the data collector to the SF-3050 via either the receiver Bluetooth port or Com1 – RS-232 Turn the receiver and data collector on and start the SurvCE program Establish a connection between the dat a col lector and the SF-3050 (either Rover or Base, as appropriate) Select the Equip tab Click on GPS Utilities
Rev. A i Release - Apr 11
Applications Note – Logging Data to Internal Memory SurvCE - SF-3050
Click on Send Com man d
Enter the following command:
Prior to logging data the first time, type the command [FSFORMAT]A:,DEFAULT
Click on Send Click on Send File
Locate the Data Logging Setup.txt file
and select it
Click on the check mark [OK]
Rev. A ii Release - Apr 11
Applications Note – Logging Data to Internal Memory SurvCE - SF-3050
The file transfer begins
At the completion of the file transer, a confirmation
window is provided to allow the user to view the success or failure of the commands sent
If the response to [LOGFILE]A:,START is [OK]LOGFILE,
then the internal drive is logging data
Click on the Back arrow Perform the normal survey steps, as needed with the
various SurvCE functions
When the survey is complete stop the data logging by accessing the same Send Command window Enter the comannd [logfile]a:,stop and click on Send Observe that the response [OK]LOGFILE is received Connect to the SF-3050 with the USB cable On the Input Terminal, type [USBMODE]Dev ice, Mas s Stora ge.
The SF-3050 2GB internal memory chip will show in Windows Explorer as an additional “removable” drive.
Open the datalog folder on the removable drive and select the folders or files to store on the PC. Drag and drop these folders or files into the designated folder on the PC.
o Removing data from the internal memory is a slow process, so it is better to keep the files small
and remove them soon after data logging is complete. In the cur rent sof t ware, do wnlo adi ng 1G B of data requires approximately 1.5 hrs. File sizes are accumulated based on the number and frequency of messages scheduled to log. At 1Hz, a typical log file used for survey purposes will be about 20MB.
Rev. A iii Release - Apr 11
Applications Note – Logging Data to Internal Memory SurvCE - SF-3050
The logged file is located in the datalog directory and the file naming convention is:
datalog_yyyy_mm_dd_sequence.dat; where sequence is the number of files recorded that day on this receiver.
Rev. A iv Release - Apr 11