Installation Instructions
PR-12, PR-12BE and PR-20BE Active Antenna Power Supplies
All power supplies are strapped for either
The strapping can be changed by a qualified technician in the field, as shown on the
diagram at the bottom of this page.
The AC input block
Pin 1 AC Hot (connect one AC lead here)
Pin 2: Not used.
Pin 3: Neutral AC (connect other AC lead here).
Pin 4: Ground or Cable Shield
The DC input block
Pin 1: +12VDC
Pin 2: +24VDC
Pin 3 Negative
accepts either 110 or 220VAC (depending on strapping).
accepts either 12 VDC or 24 VDC.
110 or 220 VAC at the factory.
Naval Electronics, Inc. 7028 West Waters Ave Suite 393, Tampa, Florida USA 33634
Phone (813) 885-6091, Fax (813) 885-3601, E-mail sales@naval.com

PR-12BE Component Layout Diagram
Naval Electronics, Inc 7028 W Waters AVE, #393, Tampa, FL 33634
Phone :+ 1-813-885-6091, email : sales@naval.com
Antenna
Output1
Output2
Signal
Attenuator
PR-12BE
Red LED
Over Current
Indicator
Green LED
Power Indicator
DC Fuse 150MA
PR-20BE Component Layout Diagram
Naval Electronics, Inc 7028 W W aters AV E , #393 , Tam p a, F L 33634
Phone :+ 1-813-885-6091, email : sales@naval.com
Note: to config 220v or 110v
1. 220V Plug jumper only No.1
2. 110V: Plug jumper both No.2 and No.3
Antenna
Output1
Output2
Signal
Attenuator
Power Ind icato r
Red LED
Over Current
Indicator
Green LED
DC Fuse 150MA
Blue Transformer
AC Fuse
150MA
Transformer
AC N/C AC GND
AC Fuse 150MA
Jumper
Jumper
Jumper
24V12V GND
3
2
1
GND
12V
24V
PR-20BE
Power
For 110V
Short 2&4
For 220V
Short2&3 Short 1&3
GND
AC
N/C
AC
220v
110v
Naval Electronics, Inc. 7028 West Waters Ave Suite 393, Tampa, Florida USA 33634
Phone (813) 885-6091, Fax (813) 885-3601, E-mail sales@naval.com