NautiCharger PM-0600H, PM-1500H, PM-1000H, PM-2000H, PM-3000H User Manual

High Frequency
Pure Sine Wave Inverter
User Manual
MODEL: PM-0600H
PM-1500H
PM-3000H
Content
Safety Instructions
A. General Safety Precautions --------------------------------------------- 1
B. Explosive Gas Precautions ----------------------------------------------1
C. Precautions When Working With Batteries ------------------------ 1
FEATURES ------------------------------------------------------------------------ 2
D. Introduction-------------------------------------------------------------------- 2
E. Name and main function--------------------------------------------------- 4
F. Rear view ----------------------------------------------------------------------- 5
G. Quick hook – up and testing -------------------------------------------- 6
H. Installation--------------------------------------------------------------------- 7
I. Operation ----------------------------------------------------------------------- 9
J. Operating limits ------------------------------------------------------------ 11
K. Trouble shooting ---------------------------------------------------------- 12
L. Maintenance -----------------------------------------------------------------13
Appendix A --------------------------------------------------------------------14
-1-
Safety Instructions
A. General Safety Precautions
A-1. Do not expose the Inverter to rain, snow, spray, bilge or dust. To Reduce risk of hazard, do not cover or obstruct the ventilation openings. Do not install the Inverter in a zero-clearance compartment. Overheating may result. A-2.To avoids a risk of fire and electronic shock. Make sure that
WARNING!
Before install and use Your Inverter, read the safety instructions.
existing wiring is in good electrical condition; and that wire size is not undersized. Do not operate the Inverter with damaged or substandard wiring.
B. Explosive Gas Precautions
This equipment contains components, which can produce arcs or Sparks. To Prevent fire or explosion do not install in compartments containing batteries or Flammable materials or in locations which require ignition protected equipment. This includes any space containing gasoline-powered machinery, fuel tanks, or joints, fittings, or other connection between components of the fuel system.
C. Precautions When Working With Batteries
If battery acid contacts skin or clothing, wash immediately with soap and water. If acid enters eye, immediately flood eye with running cold water for at least 20 minutes and get medical attention immediately.
-2-
C-1. NEVER smokes or allow a spark or flame in vicinity of battery
or engine. C-2. Do not drop a metal tool on the battery. The resulting spark or short-circuit on the battery or other electrical part may cause an explosion. C-3. Remove personal metal items such as rings, bracelets, necklaces, and watches when working with a lead-acid battery. A lead-acid battery produces a short-circuit current high enough to weld a ring or the like to metal, Causing a severe burn.
FEATURES
z Microprocessor based design with absolutely accurate and stable frequency z Switch selectable 50 or 60 Hz output, all models z Very low harmonic distortion, THD<3% z Standard inputs 12V,24V & 48V z Standard outputs 110V / 220V, 50~60Hz z Remote control unit (optional extra) z Power Saving z Panel indicators for battery voltage & load level (%) z Compact and light weight, yet rugged and vehicle rated, 83-90% efficient z Built-in fast acting AC synchronized transfer switch (<10msec)
D. Introduction:
The power inverter series are the member of the most advanced line of mobile AC power systems available. To get the most out of the power inverter, it must be installed and used properly. Please read the instructions in this manual before installing and using this model.
-3-
-4-
E. Name and main function:
E-1. Front view:
E-1-1. ON / OFF switch: Power ON/OFF switch, leave in the OFF position during installation.
E-1-2. GREEN POWER: Power energy saving enable.
OVER VOLT: Over Voltage Protection.
UNDER VOLT: Under Voltage Protection.
OVER TEMP: Over Temperature Protection. OVER LOAD: Over Load Protection.
INPUT VOLTS: Display Input Voltage. LOAD WATTS: Displays AC Load Watts.
E-1-3. AC outlet (Outlet sockets available):
North America (GFCI ) North America
Continental European (Schuko) Australia / New Zealand United Kingdom Universal Socket
-5-
F. Rear view
F-1. Ventilation window :
Do not obstruct, allow at least 1 inch for air flow. F-2. Battery terminals : Connect to 12V / 24V / 48V battery or other 12V / 24V / 48V power source. [ + ] is positive, [ - ] is negative. Reverse polarity connection will blow internal fuse and may damage inverter permanently. F-3. RS-485 Connect to remote control unit (option accessory) or taken remote controlled working status by computer. F-4. Chassis ground or to vehicle chassis using #
8 AWG wire.
connection may result in an electrical safety hazard.
WARNING!
Operation of the inverter without a proper ground
WARNING!
Shock Hazard. Before proceeding Further, ensure that the Inverter is NOT connected to any Batteries, and that
all wiring is Disconnected from any electrical Sources. Do not connect the output Terminals of the Inverter to an incoming AC sources.
-6-
¡
G. Quick hook – up and testing:
If you would like to quick hook-up the power inverter and check its performance before going ahead with your installation, please follow these guidelines: G-1. Unpack and inspect the power inverter, check to see that the power switch in the OFF position. G-2. Connect the DC NEGATIVE cable to the Negative (NEG-) terminal on the battery next, connect the cable to the negative terminal on the inverter. The connection to the negative terminal off the Inverter should be the last connection made. A spark when making this final connection is normal.
Make sure all the DC connections are tight (torque to
WARNING!
9-10 ft-lbs,11.7-13Nm). Loose connections will overheat and could result in a potential hazard.
G-3. Before proceeding further, carefully check that cable you have just connects from the negative terminal of inverter to the gative output terminal of power source.
Reverse polarity connection will blow a fuse in Inverter and may
Damage caused by reverse polarity connection is not
¡Ð
CAUTION!
Ï
permanently damage the inverter.
covered by our warranty.
G-4. Connect the cable from the positive terminal of inverter to the positive terminal of the power source. Make secure connection.
Do not make this connection in the presence of
WARNING !
You may observe a spark when you make this connection since
current may flow to charge capacitors in the power inverter.
flammable fumes, explosion or fire may result.
-7-
G-5. Set the power switch to the ON position. Check the meters and indicators on the front panel of the inverter. The voltage bar graph indicate depending on the voltage of the power source. If does not, check your power source and the connections to inverter. The other indicators should be off. G-6. Set power inverter switch to the OFF position, the indicator
lights may blink and the internal alarm may sound momentarily The is normal. Plug the test load into the AC receptacle on the front panel of the inverter. Leave the test load switch off.
G-7. Set power inverter switch to the ON position and turn the test
load on, the inverter should supply power to the load. If you plan to measure the true output r.m.s. Voltage of inverter, the meter such as FLUKE 45 BACKMAN
4410 or TRIPLETT 4200 must be used.
H. Installation:
H-1. Where to install
The power inverter should be installed in a location that meets
the following requirements:
H-1-1. Dry – Do not allow water to drip or splash on the inverter.
H-1-2. Col – Ambient air temperature should be between 0°C and
40°C, the cooler the better.
H-1-3. Safe – Do not install in a battery compartment or other areas where flammable fumes may exist, such as fuel storage are as or engine compartments.
H-1-4. Ventilated – Allow at least one inch of clearance around the
inverter for air flow. Ensure the ventilation openings on the rear and bottom of the unit are not obstructed.
-8-
H-1-5. Dust-free –Do not install the Inverter in a dusty environment where either dust, wood particles or other filings/shavings are present. These can pulled into the unit when the cooling fan is operating.
H-1-6. Close to battery/batteries –
Avoid excessive cable lengths but do not install
the Inverter in the same compartment as batteries. Use the recommended wire lengths and sizes (see section 7.3). Also do not mount the Inverter where it will be exposed to the gases produced by the battery. These gases are very corrosive and prolonged exposure will damage the Inverter.
H-2. AC safety Grounding
During the AC wiring installation, AC input and output ground wires are connected to the inverter. The AC input ground wire must connect to the incoming ground from your AC utility source. The AC output ground wire should go to the grounding point for your loads ( for example, a distribution panel ground bus ).
H-2-1. Neutral Grounding
H-2-1-1. 120V models: The neutral conductor of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation. This conforms to National Electrical Code requirements that separately derived AC sources (such as inverter and generators) have their neutral conductors tied to ground in the same way that the neutral conductor
-9-
from the utility is tied to ground at the AC breaker panel. For models configured with a transfer relay, when AC utility power is present and the Inverter is in bypass mode, this connection (neutral of the Inverter’s AC output to input safety ground )is not
present so that the utility neutral is only connected to
ground at your breaker panel, as required.
H-2-1-2. 230V models: There is no connection made inside the Inverter from either of the line conductors (line or neutral) to the safety ground.
Ground Fault Circuit Interrupters (GFCI’S): Installations in Recreational Vehicles (for North American approvals) will require GFCI protection of all branch circuit connected to the AC output of the hardwire terminal equipped Inverter. In addition, electrical codes require GFCI protection of certain receptacles in residential installations. While the true sine wave output of the Inverter is equivalent to the waveform provided by utilities, compliance with UL standards requires us to test and recommend specific GFCI’s. State power has tested the following GFCI-protected 15A receptacles and found that they functioned properly when connected to the output of the Inverter.
Do not operate the power inverter without
connecting it to ground.
Electrical shock hazard may result.
WARNING!
H-3. Making DC Wiring Connections :
Follow this procedure to connect the battery cables to the DC
-10-
input terminals on the Inverter. Your cables should be as short
as possible (ideally, less than 10 feet / 3 meters) and large enough to handle the required current, in accordance with the electrical codes or regulations applicable to your installation.
Cables that are not an adequate gauge (too narrow) or are too long will Cause decreased inverter performance such as poor surge capability and frequent low input voltage warnings and shutdowns.
These low input voltage warning is due to DC voltage drop across the cables from the inverter to the batteries. The linger and narrower these cables, the greater the voltage drop.
I. Operation:
To operate the power inverter, turn it on using the ON/OFF switch on the front panel. The power inverter is now ready to deliver AC power to your loads. If you are operating several loads from the power inverter, turn them on separately after the inverter has been turned on. This will ensure that the power inverter does not have to deliver the starting currents for all the loads at once.
I-1. Controls and indicators The ON/OFF switch turns the control circuit in the power inverter on and off.
It does not disconnect power from the power inverter. The Inverter operates from an input voltage ranging from: 10 to 16 VDC for 12V models
20 to 32 VDC for 24V models
42 to 62 VDC for 48V models
Peak performance for these inverter occurs when DC input voltage is in the Range of 10 volts to 16 volts for 12V models and 20 volts to 32 volts for 24V Models, and 42 volts to 62 volts for
-11-
48V models. From 600Watts up to 3000Watts.
I-2. Battery voltage indicator : The battery voltage bar graph indicates the voltage at the input terminals of the power inverter at low input current, this voltage is very close to the battery voltage. At high input current, this voltage will be lower than the battery voltage because of the voltage drop across the cable and connections. Ideally, the voltage should remain in the green Ares of the bar graph. If the voltage goes into the red area at top and bottom of the graph, inverter may shut – down.
I-3. Load watt indicator The AC load watt bar graph indicates the power drawn from the power inverter. It will indicate watt by loads. For long term operation , the watt should in the green & orange area of the bar graph. Short-term operation is possible with watt in the red area. If the watt rises to the flash all bar, the inverter will protect itself.
I-4. Over voltage indicator : The over voltage indicator indicates that the power inverter has shut itself Down because its input voltage has been over detect voltage 12 / 24V / 48VDC version.
I-5. Under voltage indicator : The under voltage indicator indicates that the power inverter has shut itself Down because its input voltage has been low than detect voltage 12 / 24V / 48VDC.
-12-
I-6. Over temp indicator : The over temp indicator indicates that the power inverter has shut itself down because it has become overheated. The power inverter may overheat because it has been operated at power levels above its rating, or because it has been installed in a location which does not allow it to dissipate heat properly. The power inverter will restart automatically once it has cooled off.
I-7. Overload indicator : The overload indicator indicates that the power inverter has shut itself down Because its output circuit has been short circuited or drastically overloaded.
Switch the ON/OFF switch to OFF, correct the fault condition, and then switch the ON/OFF switch back to ON.
J. Operating limits:
J-1. Power output:
The inverter will operate most AC loads within its power rating. When deeming whether a microwave over can be operated by the inverter, remember that the power commonly advertised for microwave ovens is the cooking power (the power delivered to the food) not the power actually consumed by the microwave oven. The microwave over will consume 40% to 100% more than its advertised cooking power. Check the rating sticker on the back of the over to determine its actual power draw.
The Power inverter may not be able to start some of this motor
even though their rated current draw is within the power inverter.
If motor refuse to start, observe the battery voltage indicator while
trying to Start the motor. If the battery voltage indicator drops
below 11 volts while inverter is attempting to start the motor, this
may be why the motor won’t start. Make sure that the battery
connections are good and that the battery is fully charged. If the
-13-
connections are good and the battery is charged, but the
voltage still drops below 11 volts, you may need to use a larger
battery.
K. Trouble shooting:
K-1. Common problems Television interference :
Operation of the power inverter can interfere with television
reception on Some channels. If this situation occurs, the
following steps may help to alleviate the problem.
Make sure that the chassis ground lug on the back of the
power inverter is solidly connected to the ground system of your vehicle, boat or home.
Do not operate high power loads with the power inverter
while watching television.
Make sure that the antenna feeding your television provides
an adequate (“Snow free”) signal and that you are using
good quality cable between the antenna and the television. Move the television as far away from the power inverter as
possible.
Keep the cables between the battery and the power inverter
as short as possible and twist them together with about 2 to 3 twists per foot.
This minimizes radiated interference from the cables.
K-2. Troubleshooting guide:
Do not open or disassemble Inverter, attempting to service
WARNING!
the unit yourself may result in a risk of electrical shock or fire.
-14-
Problem and Symptoms Possible Cause
Low output voltage Using average reading Use true RMS
110V : 95-105VAC,220V Voltmeter and cable.
Solution
220V : 190-210VAC See page 7
Point 6-7. of manual
Load LED bar flash. Overload Reduce load.
No output voltage.
Low input voltage.
Recharge battery,
And voltage indicator. check connections
In lower red zone and cable.
No output voltage.
Thermal shutdown
Improve ventilation
Over Temp indicator make sure ventilation
On, load less than: openings in inverter
1500W is not obstructed,
reduce ambient
temperature.
No output voltage, Short circuit or Wiring Check AC wiring
Over Load indicator Error. For short circuit or
On. Improper polarity (hot
and neutral reversed)
Very high power load Remove load
-15-
L. Maintenance
Very little maintenance is required to keep your inverter operating
properly.
You should clean the exterior of the unit periodically with a damp cloth
to regent accumulation of dust and dirt. At the same time, tighten the
screws on the DC input terminals.
-16-
Appendix A
A-1. Dip Switch (110V)
Output
S1 S2 Function S3 S4
S5
voltage
OFF OFF DC/AC OUT MODE. OFF OFF 120V OFF 60Hz
OFF ON
ON OFF UPS MODE. OFF ON 110V
ON ON
DC/AC +GREEN POWER MODE.
UPS MODE +DELAY MODE +GREEN POWER.
ON OFF 115V ON 50Hz
ON ON 100V
Out
Frequency
Dip Switch (220V)
S1 S2 Function S3 S4
S5
voltage
OFF OFF DC/AC OUT MODE. OFF OFF 240V OFF 60Hz
Output
OFF ON
ON OFF UPS MODE. OFF ON 220V
ON ON
DC/AC +GREEN POWER MODE.
UPS MODE +DELAY MODE +GREEN POWER.
ON OFF 230V ON 50Hz
ON ON 200V
Out
Frequency
-17-
A-2
NDC-AC Structure schema :
AC INPUT
NC
NO
COM
AC OUTPUT
NC
COM
NO
AC Transfer Switch
1. Code explanation:
(a) DC/AC OUT MODE :
No matter shore power has/ hasn’t the power the AC output is supply by DC/AC (so the AC Transfer Switch is ON) ( No Green Power Function).
(b) DC/AC OUT MODE + GREEN POWER MODE :
AC output power supply by DC/AC ( AC Transfer Switch ON ) When AC output load off DC/AC will turning to green power mode to reduce the consummation of the Battery.
(c) UPS MODE :
When AC input has power the AC output power supply is by AC input ( so the AC Transfer is in Switch OFF condition)
DC/AC Stand by. When AC input cut off the power the AC Transfer Switch will be in 10msec from OFFON at this time the AC output is supply by DC/AC. When AC input back to normal the AC Transfer Switch from
ONOFF at this time the AC output power is again supply via AC input. About AC input power at stander voltage ±15%, above change will
-18-
also treat as power unusually so it will automatically Transfer to DC/AC output this 15% Range can be setting from the Remote controller
(d) UPS MODE + DELAY MODE + GREEN POWER :
UPS MODE + DELAY MODE : Same as UPS mode the only different is when AC Transfer Switch working it won’t complete in 10 m sec it will delay 5 second and than complete. UPS MODE + DELAY MODE + GREEN POWER : When AC input cut of the power the AC output is via DC/AC output and when the AC output load off the DC/AC will turning into green power mode to reduce the consummation of the Battery.
High Frequency
Model No.
Continuous Output power 600W 1000W 1500W 2000W 3000W Output power surge 800W 1400W 2000W 2800W 4200W
AC Output voltage 100/110/120V ± 2% 220/230/240V ± 2% DIP switch select Output voltage Regulation -8% / ± 3% All models Output frequency 50 / 60 Hz selectable ±0.05% Accuracy Output Wave form Pure Sine Wave < 3% THD Efficiency (Full Load) 83%~85% No Load power consumption <1.5W (In power saving mode.) Input voltage range 10V – 16VDC,20V-32VDC Power saving recovery time 1 second AC Transfer time (UPS-mode) < 10msec max
LED status indicators
Protection Feature * Remote controller option. RS485 Remote controller Power output ON/OFF, green power mode, reset, error message, …etc.
Operation temperature range Storage temperature range Dimensions L x W x Hmm 370x270x120 420x270x120 470x270x120 470x270x190 530x270x190
Weight
PM-600H-12xx PM-600H-24xx
High/Low battery shutdown, over temperature shutdown, overload shutdown /
input DC voltage scale meter & output watts percent scale metter.
Over load, short circuit, over/under input voltage, over temperature, reverse
9.92 (Lbs.)
4.5 (Kgs)
PM-1000H-12xx PM-1000H-24xx
input polarity (by fuse).
-30~70 (-22°~158°F)
12.13 (Lbs.)
5.5 (Kgs)
PM-1500H-12xx PM-1500H-24xx
0~50 (32°~122°F)
15.43 (Lbs.) 7 (Kgs)
Remote controller is optional
PM-2000H-12xx PM-2000H-24xx
22.05 (Lbs.) 10 (Kgs)
PM-3000H-12xx PM-3000H-24xx
26.46 (Lbs.) 12 (Kgs)
-19-